  • @TestTest-v4h
    @TestTest-v4h Год назад +2

    What is the difference between the level 0, 1 and 2 setting in Europe (in terms of actual voltage levels)?

  • @rdp9110
    @rdp9110 Год назад

    Hello bro what sies it mean by
    Ac grid outrange... The inverter still red leaf although the output of inverter is within the ac grid

  • @chriskeirak7729
    @chriskeirak7729 8 месяцев назад

    Can I choose the output as 230v according to the datasheet?

  • @krish_machinology
    @krish_machinology Год назад +1

    How to set date & time correctly on it 🙏

  •  Год назад

    Hi, do you know if a three phase inverter (MOD 3000 TL3-XH) is capable to push all it's capacity to one phase only if there is a high load on one phase, but no load on the other two phases?

  • @jameswebb5133
    @jameswebb5133 2 года назад +2

    Hello, what does enabling Nline does? There is no explanation about it anywhere.

    • @suninhouse6988
      @suninhouse6988  2 года назад

      What exatly do you mean? What Signal? What Connector? What Pin? Or other?

    • @jameswebb5133
      @jameswebb5133 2 года назад +1

      @@suninhouse6988 at 5:30 timestamp of your video you talk about the Nline setting which you can enable or disable. What does this function do? Thanks for your help.

    • @suninhouse6988
      @suninhouse6988  2 года назад

      This is enabling relays by enabling GND signails of its coils

    • @jameswebb5133
      @jameswebb5133 2 года назад

      @@suninhouse6988 do you have an example? I didn't understand what you mean well. Thanks again

    • @suninhouse6988
      @suninhouse6988  2 года назад

      There are digital outputc potential free contacts No&Nc driven by coils

  • @vironmanning7490
    @vironmanning7490 3 года назад

    1.What is the correct voltage for the inverter to operate . Should it be above or below 230?
    2. Which range should the inverter be set ? Should it be 0, 1, or 2 ?

    • @suninhouse6988
      @suninhouse6988  3 года назад

      Range should be increased if over or under voltage occurs. Different countries have different low and up limits.

  • @AlejhoCuellar
    @AlejhoCuellar 3 года назад +1

    Hi, My inverter is on standby, help, please

    • @suninhouse6988
      @suninhouse6988  3 года назад

      What do you mean in standbay? If you bought from SunInHouse contact by phone or Messenger in working day.

  • @ZdravkaSlezak
    @ZdravkaSlezak 2 года назад

    Hellp, thank you for the video but can I ask aditional questions? I have to set parameters such as
    U > 1,1 pu; 30s (253 V, 30s)
    U >> 1,14 pu; 0,2s (262 V, 0,2s)
    U < 0,9 pu; 1,5s (207 V, 1,5s)
    U 51,5 Hz; 0,1s
    f < 47,5 Hz; 0,1s
    Any idea where I could do something like that? I installed growatt dongle (ShineWiFi-X module) but i cannot find such settings.
    Thank you in advance!

    • @suninhouse6988
      @suninhouse6988  2 года назад +1

      These parameters are an integral part of the standard on the basis of which power generators are connected to the grid. These parameters are changed when the standard is changed. From the prosumer's point of view, higher limits give better independence of the system with fluctuations in network parameters (fewer shutdowns due to exceeding the parameters). In Europe, each country has its standards, which are very similar, the main difference is the voltage limits. In this respect, the largest permissible ranges apply in Germany and Italy, and choosing the standards of these countries gives the greatest independence of the system from fluctuations in network parameters. Other parameters of the standards, such as frequency, phase shift, harmonic content coefficient, etc., are not subject to separate branches of the inverter firmware algorithms.

  • @Solcellers
    @Solcellers Год назад

    IsGrowatt MIN 3000 TL-XH compatiple with APX-battery

  • @ahmadrashed9134
    @ahmadrashed9134 2 года назад

    Hello again I need for unitit Emirates

    • @suninhouse6988
      @suninhouse6988  2 года назад

      it is outside of the European Union so shipping costs are custom and you would probably pay some export duty fees.