What is Zero Export and DGPV Synchronisation and it’s working ? || How solar Run on DG without Grid?

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024
  • Working of Zero Export and DGPV synchronization ? || What is DGPV Synchronization ? || How you will get faster returns from solar ? || How we can Run Solar with DG without Grid ?
    #dgpv #zeroexport #RPP
    Solar
    Safest
    Smarter
    Saur urja
    Biljli Kaise bachaye
    Solar se Bijli Kaise Bachaye
    Benefits of Installing solar
    Profitable solar
    Solar k Fayede
    Solar Lagane k Fayade
    MCB
    MCCB
    ACB
    AJB
    ACDB
    DCDB
    Lighting Arrester
    walkway
    cable Tray
    Solar Panel
    Solar Inverter
    Solar Cable
    AC Cable
    Follow me on -
    Telegram- t.me/+uVOzUWjD...
    LinkedIn- / raman-kumar-666436141
    Facebook - / solarfacts-37057195372...
    solar structures
    Solar panel mounting structure
    Solar mounting structure
    acdb and dcdb for solar system
    acdb box price
    dcdb box for solar system
    dcdb box price
    long rail solar structure
    mini rail for solar panels
    mini rail solar structure
    solar mounting structures
    solar panel structure
    solar structure
    solar structure types
    types of mounting structures for solar panels
    types of solar mounting structure
    types of solar structure
    mounting structure for solar panels
    mono rail solar structure
    solar acdb box
    solar acdb dcdb box
    solar dcdb box
    solar mini rail
    standing seam solar structure
    tilted solar structure
    acdb box for solar
    dcdb box for solar
    Video link -
    1. How solar zero export works.- lnkd.in/evPgfuj2
    2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
    3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
    4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
    5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
    6. How to check Current Transformers? - lnkd.in/eT5gc99e
    7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
    8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
    9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
    10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
    11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
    12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
    13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
    14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
    15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
    16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
    17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
    • Solar Power Plant Shad...
    18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
    19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
    20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
    21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
    22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
    23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
    24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
    25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
    26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
    27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
    28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
    29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
    30.What is Skin Effect ? // Why Skin effect happens in AC not in DC ? // Why current flow through surface of conductor ? -- lnkd.in/eHTtuFtK
    For more information contact us 😊.
    Name - Raman Kumar
    Contact No- 9871073342

Комментарии • 110

  • @rajeshmohan7881
    @rajeshmohan7881 3 месяца назад +1

    Very very informative and rare topic. I was needing this information as am going to make DPR for 250 KWp on grid plant.
    Thank you very much.

  • @shubhamgodbole9836
    @shubhamgodbole9836 5 месяцев назад +2

    Plese make vidio of actual connection Thank You

  • @KaleemKhan-i4y
    @KaleemKhan-i4y 10 месяцев назад +1

    thankyou so much sir for explaining in wonder full ways it is vary help full for me

  • @maneeshkumarvishwakarma1193
    @maneeshkumarvishwakarma1193 Год назад +2

    Beautiful guide line sir👌🏽👌🏽

  • @marbombam4281
    @marbombam4281 2 года назад +1

    Very informative indeed, keep doing 👍👍

  • @SunilPatel-xg2rx
    @SunilPatel-xg2rx 2 года назад +1

    Knowledgeable content 👍

  • @jyothiprakash599
    @jyothiprakash599 Год назад

    Excellent presentation, very well explained in detail 😊

  • @RajeevChauhanworld
    @RajeevChauhanworld 22 дня назад

    Make a video on mathematical models of control of inverter

  • @udaymondal1525
    @udaymondal1525 Месяц назад

    ❤❤

  • @usamaghauri8618
    @usamaghauri8618 2 месяца назад

    Can we use ups instead of dg for reference in case of load shedding?

  • @shubhamdahiwale8657
    @shubhamdahiwale8657 Год назад

    Inverter ke components and circuit diagram ke uper video chahiye sir

    • @solarfacts4242
      @solarfacts4242  Год назад

      ok give me some time i will make one video on it

  • @siligurisolarstation2310
    @siligurisolarstation2310 Год назад +1

    Sir very good information give me zero xport divice installation please share with me

  • @johnruben1444
    @johnruben1444 Год назад +1

    I am installing 3kw on-grid system in my apartment with zero export CT. In the basement we have a big DG which powers all flats (total 30) including common area and Lift. Mine is a single phase, do you propose DG PV system or should I disconnect the DG ? My electrician was telling he would pull a separate line for a kitchen point from DG (post DG disconnection in the basement to my flat) will it be feasible as I am not sure how on-grid inverter would react since it will be connected to my Mains. Please help.

    • @solarfacts4242
      @solarfacts4242  Год назад +1

      If you are not doing DG synchronisation please keep solar separate

  • @kismatconnection2008
    @kismatconnection2008 Месяц назад

    what is the use of grid in this case

  • @Govindsingh-xo7ov
    @Govindsingh-xo7ov Год назад +1

    DG PV plant ka Synchronisation connections ka video banaye sir, please

    • @solarfacts4242
      @solarfacts4242  Год назад

      Sure sir
      Bahut jaldi i will make video on it

  • @shibu2935
    @shibu2935 2 года назад +3

    Hello Raman...I am seeing your work for the first time...I didn't know you have a youtube channel ....it is so impressive that you've reached such professional levels in your carrier....your parents must be really proud of you .....a round of applause from my side 👏👏

    • @solarfacts4242
      @solarfacts4242  2 года назад

      Thanks you 🙏🏻
      May I know from where you are ?

    • @shibu2935
      @shibu2935 2 года назад +1

      @@solarfacts4242 We are from Kanpur....we are neighbours in Tirwa ...Seema and family

    • @solarfacts4242
      @solarfacts4242  2 года назад

      Thank you Mousi 🙏🏻

  • @MuhammadUmer-dp5eq
    @MuhammadUmer-dp5eq Год назад +1

    Thank you so much, Brother. You have explained it very well. But I have a question in mind can we install a zero export device in place of the PV-GEN set when we turn ON the on-grid inverter with DG.
    As we install Zero export device then no Power will go towards DG.Can we do this thing?

    • @solarfacts4242
      @solarfacts4242  Год назад

      Zero export only insure that the power flow should not be to the grid

    • @MuhammadUmer-dp5eq
      @MuhammadUmer-dp5eq Год назад

      @@solarfacts4242 not for DG?? because when our Generator turns on the Inverter Considers its reference and Starts its production as the inverter does not know the difference between Grid and DG??
      Kindly give me a clear answer about this thing??
      It's a humble request from my side

  • @siligurisolarstation2310
    @siligurisolarstation2310 2 дня назад

    Very nice 👍 excellent explained pv Dg video need.....ok.sir

  • @RealMe-w9l9n
    @RealMe-w9l9n 8 месяцев назад

    Bahi 2 inverter ko parallel Kyu karty hai?

  • @nirdeshsaini
    @nirdeshsaini 6 месяцев назад

    Thank you. It's a beautiful video. Any ball park cost for a DG Synchronization for 100 KW system.

  • @makarandvaidya-q2w
    @makarandvaidya-q2w 4 месяца назад

    I don’t know dgpv synchroniser, but there is 1 more technique. Called zero export feature, that’s it, that’s sufficient, let dg run at 30% come what may & after that let solar start producing, since it is sync w this new ref (dg) it will pump power to load & letting dg to not to raise its delivery, as solar start under performing, means it will not be able to cater the load abv 30%, so in that naturally dg will start pumping power to load till it’s 100%, & as solar starts gaining its capacity, it will start pumping in to the load & thence dg will start derating its capacity. Just remember after start of dg, on grid fail, we r simply maintaining the lower limit of its operation to 30%, and sw on zero export feature of solar. Rest is taken care, adaptively.

  • @pallabdas2972
    @pallabdas2972 9 месяцев назад

    Could you please make a programme on installation procedure of dgpv synchornisation

  • @rizwanjanu4204
    @rizwanjanu4204 Год назад +1

    Bahi ager solar panels ke cable ke sath main power 440 ke cable chalay to koi problem Hoti hai

    • @solarfacts4242
      @solarfacts4242  Год назад

      no
      but there should be a gap required as per current

  • @FarhanEngg
    @FarhanEngg 2 года назад +2

    I have been longing to understand DG sync in detail in hindi. Thanks a lot Raman bhai. Masha Allah nice work. Keep us technically energised.

  • @fahadmukhtar1124
    @fahadmukhtar1124 2 года назад +1

    if the load is 20 kw suppose for whole day then will it effect diesel generator life ?

  • @reliablesolarenergy
    @reliablesolarenergy 9 месяцев назад

    How can DGPV system work in cold storage solar system? Is it advisable or not?

  • @bhuvneshkumar912
    @bhuvneshkumar912 2 года назад +1

    Sir meri site 1mw par MFM, DG par lga h or usse hi sync ho jata h . DGPV kyo

  • @RahoulSubberwal
    @RahoulSubberwal 4 месяца назад

    Very interesting, and appropriate for a problem we are attempting to solve at present. The one point that was not discussed is if the load is less than half the installed Solar panel capacity, and this load is also variable in that it can be reduced to suit the output of the solar panels, then a low kw generator solution would work. Even if the generator occasionally trips, not having to run a large generator at 30% will result in significant saving on fuel. This scenario would work less well during the monsoon months! Thank you for making this video!

  • @MaheshPatel-sh9tq
    @MaheshPatel-sh9tq Год назад +1

    Home Invertor se refrance volt de ke solar Invertor ko kaise chla sakte hai

    • @solarfacts4242
      @solarfacts4242  Год назад

      Already there is a video please check my channel

  • @lalitpuri6071
    @lalitpuri6071 Год назад +1

    Thanks for the vedio, I have installed Solar in my Flat which is on Top Floor of the society, I have 3-Phase supply which is coming via Grid and society DG set via a Dual meter. Please let us know how can I use the Net meter in this case and shall I need to install DGPV

    • @solarfacts4242
      @solarfacts4242  Год назад

      You can do net metering if you are getting supply from the grid and in this case your solar connection should be separate from the DG

  • @dapakarswapnil3264
    @dapakarswapnil3264 10 месяцев назад

    Reverse current found in inverters due to DG , what is the reason

  • @muhammadrashid-up9no
    @muhammadrashid-up9no 3 месяца назад

    Agar DG line pr zero device lga le tu kya phir be DGPV ki zrort ho ge ?must replay

  • @makarandvaidya-q2w
    @makarandvaidya-q2w 4 месяца назад

    Icelanding nahi ilanding spell as islanding

  • @laxmikantpatel5764
    @laxmikantpatel5764 Месяц назад

    Minimum dg 30% load rakhna necessary hai kya, ya kam bhi rakh sakte hai

  • @FarhanEngg
    @FarhanEngg 2 года назад +1

    I have one doubt. What if DG is higher and Solar plant is lower in size? Eg. 200kv DG and 20KW solar

    • @solarfacts4242
      @solarfacts4242  2 года назад

      In this my solar will start when after 60 Kw load

  • @aabidbhat3816
    @aabidbhat3816 2 месяца назад

    Helo Raman, thanks for the video. I have one question, in this case we have to install Zero export meter also to avoid the export when grid is not available. Please correct me

    • @solarfacts4242
      @solarfacts4242  2 месяца назад

      No sir we will only generate the power which is required to run the load
      So extra power will not be generated, and export will not happen

  • @shashanksharma8443
    @shashanksharma8443 Год назад +1

    Hello sir, you are talking about refrence voltage so how reference voltage require for particular on grid inverter?

    • @solarfacts4242
      @solarfacts4242  Год назад

      because if grid is not available we can not export the power
      that's why reference voltage is required

  • @siladityabhowmik8623
    @siladityabhowmik8623 Год назад

    Thank you for your educational video. Request you to make a video on SOLAR - DG- BATTERY BANK (LIFEPO4) Hybrid system. It will be better if you integrate windmill system also . Thank you .

  • @PardeepKumar-gg6em
    @PardeepKumar-gg6em 2 года назад +1

    Good work Raman as always. Pardeep from Apex Solar Jaitu Punjab

  • @asadiqbalengineeringservic7680
    @asadiqbalengineeringservic7680 8 месяцев назад

    Hi how are you my dear friend I am Asad iqbal from Pakistan I have solar installer. Nice information for me

  • @riteshsingh5039
    @riteshsingh5039 2 года назад +1

    Thanks Raman ji, your video content is excellent and informative. Nicely explained too 👍

  • @shahzadkhan9307
    @shahzadkhan9307 Год назад

    A SIR, Kindly make a vedio on DG PV sychronius Box we are waiting

  • @sauravmodak507
    @sauravmodak507 2 года назад +1

    Why make it complicated? Why can't the inverter cut grid during power out and run by itself.. Generation on shinewave is not so hard If it still needs reference..

    • @solarfacts4242
      @solarfacts4242  2 года назад

      Because these inverters having anti-islanding feature

  • @talhazubair8306
    @talhazubair8306 7 месяцев назад +1

    Great knowledge sir❤

  • @YadaYadaYadaYada
    @YadaYadaYadaYada 10 месяцев назад

    Excellent! Yes please do make a video on the DGPV Synchronisation box. Thanks

  • @niteshgiri4650
    @niteshgiri4650 2 года назад +1

    Pla send dc voltage drop calculation excel file ..

  • @naeem.akram111
    @naeem.akram111 Год назад

    please make a video dgpv synchronization

  • @prasadjoshianwikar2634
    @prasadjoshianwikar2634 2 года назад +1

    What about PF correction at DG & PV load sharing at high/varying power demands?

    • @solarfacts4242
      @solarfacts4242  2 года назад

      I will make one video on it

    • @barunkumar1984
      @barunkumar1984 Год назад

      ​@@solarfacts4242if video is uploaded, please share link

  • @ajeet.singh800
    @ajeet.singh800 2 года назад +1

    प्रिय मैं आपका बहुत बहुत धन्यवाद दिल से करना चाहता हू ,खूबसूरत कॉन्सेप्ट

  • @Bhardwaj5
    @Bhardwaj5 Год назад

    Nice explanation sir,
    Ek or video Synchronisation device pe agar bataye jiski help se design kr Pau.

  • @badarabbas1035
    @badarabbas1035 2 года назад +1

    Bai instrument capping ke bary or instrument scanl ke bare vedio bnao

  • @zeeshanalikhan5167
    @zeeshanalikhan5167 2 года назад +1

    Good concept explanation in very easy way...👍

  • @fahadmukhtar1124
    @fahadmukhtar1124 2 года назад +1

    If the load is itself very low that is nearly 15% of Diesel generator then what? DG set will start to deteriorate or get itself damage?

    • @its_amir
      @its_amir 2 года назад

      Then there is no point to connect DGPV sync.

    • @fahadmukhtar1124
      @fahadmukhtar1124 2 года назад

      @@its_amir There is no grid so DGPV always working in parallel .

    • @solarfacts4242
      @solarfacts4242  Год назад

      That will affect in long term

  • @raginisingh5762
    @raginisingh5762 2 года назад +1

    Please make video on DGPV synchronisation box also .

  • @influx_engineering
    @influx_engineering Год назад +1

    very well explained

  • @PratinChaudhari
    @PratinChaudhari 2 года назад +1

    Bhai.....banado dg-pv connection pe video🙏

  • @pagladasu9305
    @pagladasu9305 Год назад

    Excellent explanation. Keep it up

  • @irshadmahmood1827
    @irshadmahmood1827 11 месяцев назад

    Good explanation ❤

  • @sameermfaroor9856
    @sameermfaroor9856 Год назад +1

    Great lecturer

  • @meharsingh4539
    @meharsingh4539 10 месяцев назад

    Good information

  • @YadaYadaYadaYada
    @YadaYadaYadaYada 10 месяцев назад

    Great Job!!

  • @ramsingpadol3309
    @ramsingpadol3309 Год назад

    Tnx u sir

  • @karuneshkvaiswar612
    @karuneshkvaiswar612 21 день назад

    Please give your contact number,
    I want to install 150kw system for my cold storage in barabanki uttar pradesh

  • @karuneshkvaiswar612
    @karuneshkvaiswar612 21 день назад

    Please give your contact number,
    I want to install 150kw system for my cold storage in barabanki uttar pradesh