Vaillant Ecotec failed turret seal

Поделиться
HTML-код
  • Опубликовано: 16 сен 2024
  • DISCLAIMER:
    This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
    ~
    This is a common fault on Vaillants with the turret seal perishing. Its noticeable when you see the crusting around the top of the main heat exchanger and means there's products of combustion spilling into the boiler.
    I always keep a few of these seals along with the flue seals as it's a case of either shutting the boiler down or fixing it on the spot to keep your customer going with heating and hot water.

Комментарии • 17

  • @experienceb4bob
    @experienceb4bob 2 года назад +4

    The best thing about this guy is that he tell you the part number....so u can save the video and also can right the number in your dairy .
    ⭐⭐⭐⭐⭐guy

  • @charmiri1
    @charmiri1 2 года назад +2

    Many thanks for that. Just to note though that I think Vaillant only advocate the use of water or saliva as lubricants for flue seals and not grease.

  • @Cezartravel24
    @Cezartravel24 2 года назад

    Thanks for your video I am only new qualified about 6 months your video helping me everyday

  • @Smokeblow
    @Smokeblow 2 года назад

    Refreshing to see a good engineer with safety awareness 👊💯

  • @bluedwarf8858
    @bluedwarf8858 3 года назад +1

    At first I thought why are you wearing a hair net then saw the rest of your head and realised it was a cap. Another good video

  • @Ed-fp9rx
    @Ed-fp9rx 9 месяцев назад +1

    really good video

  • @chrisbw591
    @chrisbw591 2 года назад

    Short and to the point, good video

  • @sheriefgerges7789
    @sheriefgerges7789 Год назад +1

    Amazing you are , love your videos , great knowledge

  • @yensabi
    @yensabi 3 года назад +1

    Nice one.....👍

  • @hamzaparvais3948
    @hamzaparvais3948 2 года назад

    Thanks for knowledge nice one

  • @Connor-ts8mk
    @Connor-ts8mk Год назад +1

    Mate are these seals universal across all vaillants? As in size and part number

    • @cputilitysolutions
      @cputilitysolutions  Год назад +1

      As far as I know, yes. However might be different with the old turbomax boilers, but all the condensing range so far I've come across are the same

    • @Connor-ts8mk
      @Connor-ts8mk Год назад +1

      @@cputilitysolutions cheers mate. So common on these I've noticed

  • @markbest2836
    @markbest2836 Год назад

    if you carry out the test and you only get co reading around 10, and no ratio and co2. what would you do ?

    • @cputilitysolutions
      @cputilitysolutions  Год назад

      Any CO reading on the air intake side requires investigation