HVAC148 Vacuum p15 example 3 The 4 port manifold gauge

Поделиться
HTML-код
  • Опубликовано: 30 сен 2024
  • You will see some people prefer the 4 port manifold.
    In this video we go step by strep using the 4 port manifold for a vacuum and also see some of the short falls.

Комментарии • 22

  • @YTsux24-7
    @YTsux24-7 Месяц назад

    2.5 hrs to pull that vac?
    How long is that line set?
    What cfm is the pump rated to?
    Was the pump oil contaminated?

  • @erikizquierdo7130
    @erikizquierdo7130 Месяц назад

    My job usually does a 10 min decay test if it doesn’t go above a 1000

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 года назад +4

    I'd be a liar to say i never used my gauges to pull a vacuum. Thats just how everyone back in the days did it. No micron gauge, no core tools, no large hoses....no cares in the world....we used to use a 2 smoke vacuum....after 2 cigarettes....vacuum was done. Hahahaha. Thankfully it was R22 equipment and is very forgiving of careless install mistakes....410 is not as forgiving. I have since obviously changed my methods of vacuum. Things were simpler back in the days. Started this trade back in 99

    • @love2hvac
      @love2hvac  2 года назад

      I was lucky to get to work with some commercial guys back in the day that where big on Deep vacuum. thus by analog micron gauge.
      But yes I too would be lying if I said I never cut corners or was in hurry.

  • @joeoehm4341
    @joeoehm4341 8 месяцев назад

    Can I connect the bottle for charging to the "red port" on the manifold, instead to the "yellow port"? Because I`ve a mini-split and the "red port" is free. I would like to use the "yellow port" only for recovering refrigerant. I have 2 knobs on my bottle, for liquid and gas. This means I wouldt have to change any hoses. Or is there something against doing it this way? Could the SMAN be damaged as a result?

  • @ducharmehvactraining925
    @ducharmehvactraining925 2 года назад +1

    thanks, always good Ty

  • @scoobtoober2975
    @scoobtoober2975 4 месяца назад

    would you clean an oil gauge set and hoses with isopropyl. field piece says you can clean all but the vacuum port with it.

  • @tecniman356
    @tecniman356 5 месяцев назад

    How many pounds of freon we should put while the system is off?

  • @mikev.1034
    @mikev.1034 2 года назад +1

    👍👍

  • @lesliedaisley7846
    @lesliedaisley7846 2 года назад +1

    What is hvav

    • @love2hvac
      @love2hvac  2 года назад

      😂 one of my endless spelling and keystroke errors! Thank you for the heads up!

  • @samersarah957
    @samersarah957 2 года назад +2

    Thank you so much Mr.Ty keep going you’re in the head of teaching.🌹

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 года назад +2

    A little different than hanging the gauges for 30 minutes to see if the needle moved.
    Thanks again for the videos.
    🥃🥃🍺🍺🍺🏌🏻‍♀️🎯
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

    • @love2hvac
      @love2hvac  2 года назад +1

      I haven't used the 4 port for vacuum in years. I was surprised at how long it took!

  • @butlerstouchHVAC
    @butlerstouchHVAC Год назад

    why not charge through the suction after deep vacum?

    • @love2hvac
      @love2hvac  Год назад +1

      Liquid will collect in the suction line, when the compressor starts, it will flood it and cause damage.

    • @butlerstouchHVAC
      @butlerstouchHVAC Год назад

      @@love2hvac so after every vacum you charge it back up through the liquid when its off?

    • @butlerstouchHVAC
      @butlerstouchHVAC Год назад +1

      @@love2hvac when should you charge through the suction

    • @love2hvac
      @love2hvac  Год назад +1

      Yes especially after vacuum.

  • @ethanslifka3904
    @ethanslifka3904 2 года назад +1

    Why are ball valves generally preferred when using a 4 port manifold?

    • @love2hvac
      @love2hvac  2 года назад +1

      Ball valves are preferred for all manifolds.
      They provide full flow
      They are not restrictive
      They rarely fail
      They provide more control
      They are not as affected by contaminants first and debrise.

    • @ethanslifka3904
      @ethanslifka3904 2 года назад

      @@love2hvac Thats good to know. Thanks for the speedy reply!