AO Smith Electric Water Heater Upper Thermostat

Поделиться
HTML-код
  • Опубликовано: 21 авг 2024
  • This video provides step-by-step instructions for replacing the upper thermostat on AO Smith electric water heaters. The two most common reasons for replacing the upper thermostat are when the water heater is too hot or does not heat.
    Click here to purchase part #9001954045: www.repairclini...
    Additional water heater repair, troubleshooting tips, help with finding your model number, and part replacement videos: www.repairclini...
    All the information in this thermostat replacement video is applicable to the following brands: AO Smith
    Tools used: Phillips head screwdriver, tape, flat head screwdriver
    Connect With Us!
    plus.google.co...
    / repairclinic
    / repairclinic
    / repairclinic
    Join our free VIP email list for discounts and money-saving tips: tinyurl.com/pnn...
    Check out our blog: www.DIY.RepairC...
    Don't forget to like and comment on this video, and subscribe to our channel!

Комментарии • 31

  • @bgregg55
    @bgregg55 9 лет назад +11

    it's very important to make sure the new stat is held tightly against the tank wall by the securing clips.

    • @repairclinic
      @repairclinic  9 лет назад +1

      bgregg55 We would agree with that.

  • @red380zzz
    @red380zzz 6 лет назад +3

    I just bout a 38 gallon AO Smith low boy water heater from LOWE'S and dry fired the top element. I am now replacing the thermostat and element to make sure I covered all my areas of DIY amature mistakes. I noticed ON YOUR VIDEO AT :55 ON THE TOP ELEMENT ON THE RIGHT SIDE IF YOU ARE FACING THE ELEMENT YOU HAVE TOP WIRE= RED MIDDLE WIRE = BLUE AND BOTTOM WIRE= RED. BUT AT 1:58 OF YOUR VIDEO YOU HAVE TOP WIRE = RED, MIDDLE WIRE = RED, BOTTOM WIRE = BLUE.
    CAN YOU PLEASE TELL ME WHICH IS CORRECT? IS THIS A SAFETY HAZARD???

  • @BadWayneBroadway
    @BadWayneBroadway 7 лет назад +2

    Is this a common problem with A.O. Smith water heaters or just this 80 gallon model? My warranty expired one month ago and go- figure it starts leaking at the upper element. Can't tell for sure yet if it is the element or the tank but the upper thermostat is severely corroded.

  • @PacoOtis
    @PacoOtis 8 лет назад +4

    Do you have a video that explains how and why the thermostat does what it does? Thanks!

  • @chnglna8342
    @chnglna8342 9 лет назад +1

    my water isn't as hot as it use to be. I had done a load full of laundry past few days with hot water selection, Could this have caused the problem? What do you think could be wrong with the heater at this point?

    • @repairclinic
      @repairclinic  9 лет назад +1

      Connie A The hot water tank should be able to handle the amount of water the washer called for. Do you replace a heating element or thermostat? Either one of these parts can fail and cause poor heating.

    • @chnglna8342
      @chnglna8342 9 лет назад

      i also noticed the switch in electric panel tripped for the water heater and when i tried to turn it back, the whole house lost power. But then i turned the main switch back and everything started working except the water heater

    • @repairclinic
      @repairclinic  9 лет назад

      Connie A We would suspect a heating element has shorted to ground (through the water) causing the breaker to trip.

    • @chnglna8342
      @chnglna8342 9 лет назад

      do i need a new water heater or can this repaired instead of replaced?

    • @repairclinic
      @repairclinic  9 лет назад

      Connie A Get the model number of your hot water heater to look up a new element. Here is a video we produced for an element. ruclips.net/video/vtMv-MkIaQI/видео.html

  • @suri9989
    @suri9989 8 лет назад

    We r using AO Smith ewsh15 water heater,from past week the heater is not working , when I start the heater it showing orange light instead red light(on heater).What could be the problem.Please xplain.

  • @daoyang8919
    @daoyang8919 9 лет назад

    My water heater doesn't seem to know when the water is cold. Even when it does, it has a hard time staying lit. I'm even turn it off and on. It'll try to light and burn 3 times before it just stops and 3 lights stays on. I have to do this process multiple times before it finally stays lit. What can be the issue and what should I replace first?

    • @repairclinic
      @repairclinic  9 лет назад

      +Dao Yang It sounds like a problem with burner assembly. Without model information we can't say what parts your hot water heater has.

  • @hmpz36911
    @hmpz36911 9 лет назад

    Water is leaking from behind my thermostat cover plates. Any idea why that is and/or how to fix it?

    • @repairclinic
      @repairclinic  9 лет назад +1

      +hmpz36911 The seal on a heating element may be going bad. The the tank itself is leaking then the heater will need replacement.

  • @alfakilla1
    @alfakilla1 8 лет назад

    Good video....thank you

  • @Dustytri
    @Dustytri 8 лет назад

    Thanks for the help! Problem solved! :-)

  • @bklionfan
    @bklionfan 10 лет назад

    Hi I have this same heater and the water in the house has gone completely ice cold. I know there's power to it I tripped the beakers and still no hot water. What do you suggest?

    • @repairclinic
      @repairclinic  10 лет назад

      bklionfan You most likely have a bad lower heating element. I would turn off the power to the water heater and check the element with a meter. If it’s bad replace the element and that should fix the problem. If the element checks ok, test the thermostats and make sure the limit isn’t tripped on the top thermostat. If the limit is tripped (red button popped out) you have a bad thermostat or a shorted element.

    • @jackattack4047
      @jackattack4047 8 лет назад

      +RepairClinic.com can you push the button back in to make it work?

  • @TroyShaw
    @TroyShaw 9 лет назад

    My water is getting way too hot, then the red button breaker pops out. Does that mean the thermostat has gone bad?

    • @repairclinic
      @repairclinic  9 лет назад

      Troy Shaw Most likely one of the heating elements is shorted to ground (through the water) and it is staying on all the time. Enter you model number into our website to find replacement heating elements. www.repairclinic.com?TSLID=1773

    • @TroyShaw
      @TroyShaw 9 лет назад +1

      I replaced both thermostats and so far so good. It seems to have fixed the problem.

    • @repairclinic
      @repairclinic  9 лет назад +1

      Troy Shaw If you start running into trouble again we would replace the heating elements. Thanks for sharing.

  • @benralph3603
    @benralph3603 9 лет назад

    I have a double element hot water tank my water starts of hot then after a few minutes it goes ice cold ? Could it be the thermostat or the heating elements ? An how do you check the thermostat ?

    • @repairclinic
      @repairclinic  9 лет назад

      Ben Ralph You most likely have a bad heating element. The thermostats can be checked with an Ohm meter. The top one is a little more difficult to check than the lower. When the upper thermostat is closed, there should be continuity between #1 and #2 and also between #3 and #4 terminals. This is the upper safety limit part of the thermostat. The lower part should show continuity between #1 and #2 terminals. When the upper thermostat reaches the set temperature it switches power from the #2 terminal to the #4 terminal and sends power to the lower element . The lower thermostat has only two terminals that should be closed until the thermostat reaches the set temperature. Both elements should show continuity. You should remove one of the wires from the thermostat or element that you are testing to prevent a false reading. Our How It Works: Water Heater will be helpful to you: ruclips.net/video/ZwapTUBP6jw/видео.html

    • @benralph3603
      @benralph3603 9 лет назад

      Thank you ! I found out I had a bad heating element on top ! All is good now !

    • @repairclinic
      @repairclinic  9 лет назад

      Ben Ralph Great!

    • @benralph3603
      @benralph3603 9 лет назад

      New problem ! Changed both elements now water starts hot then goes cold after 2-3 mn ! Both elements test good ! Could it be the thermostats?

    • @johnlopez6764
      @johnlopez6764 7 лет назад

      RepairClinic.com. ?? why does my thermostat keep tripping