CFD Analysis Centrifugal Pump use Solidworks

Поделиться
HTML-код
  • Опубликовано: 23 дек 2021
  • In this video i show you how to CFD Analysis Centrifugal Pump in Solidworks.
    I hope this video will help you to design use solidworks
    Just enjoy it, and like it.
    Thanks For Watching
    Click this link below to see playlist Solidworks Tutorial For Beginner
    • Solidworks Exercise 1 ...
    And click link below to see Solidworks Lesson
    • Solidworks Tutorial Le...
    Follow my Instagram @thirdkoniago if you want to get more information
    / thirdkoniago
    #ThirdKoniago #SolidworksTutorial #AnalysisCFD

Комментарии • 86

  • @rydinorwin
    @rydinorwin 11 месяцев назад +2

    Love this, very well done!

  • @marcoalberti1957
    @marcoalberti1957 2 года назад +5

    Fantastic video! Really useful for understend how to do flow smulation, thank u!

    • @EngineerKoniago
      @EngineerKoniago  2 года назад

      Youre welcome, I hope you enjoy my video tutorial

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      Hi marco i make a new tutorial about this.
      i hope you like it.
      ruclips.net/video/_qubBlxAiH0/видео.html

  • @MahdiShraim
    @MahdiShraim 21 день назад

    Many thanks pal, you did a great job.

  • @thegojira444
    @thegojira444 11 месяцев назад +1

    thanks for video. why did u select rotation sliding instead of averaging local region?

  • @isurudushan5566
    @isurudushan5566 6 месяцев назад +1

    Thank You

  • @MohammadMohammadiBirgani-ls8bi
    @MohammadMohammadiBirgani-ls8bi Год назад +2

    Hi dear
    It seems that the direction of the impeller blades is designed in reverse!

  • @brunobassottibbstech
    @brunobassottibbstech 9 месяцев назад +1

    Greetings, my dear. Just an observation I would like to make to you, which would be about the directional direction of the rotor vanes there that is unlike the direction of flow the discharge output of the volute.

  • @cengizce5442
    @cengizce5442 7 месяцев назад +1

    Hello, thank you for your support. It was really very useful. Does the propeller need to be concentric during the assembly process? Or do we need to fix it with a plane? I need your support on this matter.

    • @EngineerKoniago
      @EngineerKoniago  7 месяцев назад

      Your welcome.
      just make sure you make a right assembly procees

  • @learningpower9437
    @learningpower9437 6 дней назад

    Question....why the torque was calculated in the x direction?? ...it will make more sense to calculate the impeller torque around the z direction. Let me know. Thanks!!!

  • @rohitkhamkar904
    @rohitkhamkar904 Год назад +1

    Dear Sir,
    Kindly specify the answer to why for every selection. This answer will be very helpful for conceptual understanding. Remaining its easy to understand without knowing answer to why...
    Thank you

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      Thanks You For Advice.
      I hope you can enjoy my tutorial..
      First of all, we have to know the concept of analysis.
      i'am Still learn, Thanks You

  • @b-girlrawiya3906
    @b-girlrawiya3906 Месяц назад +1

    Thankx for tutoriel, really it was a fantastic and can you send me a geometrie ?

    • @EngineerKoniago
      @EngineerKoniago  Месяц назад

      You can find the geometri design in my previous tutorial bro.

  • @sujeeshvellaramthodi6822
    @sujeeshvellaramthodi6822 2 года назад +2

    the curvature of vane in impeller is in opposite direction.

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      I hope this new Tutorial Can help you..
      Thanks for comment and support in my channel.
      ruclips.net/video/_qubBlxAiH0/видео.html

  • @vasilemiruna-ioana5402
    @vasilemiruna-ioana5402 27 дней назад +1

    Hello. Why did you create the fluid region part?

    • @EngineerKoniago
      @EngineerKoniago  27 дней назад

      Hi. Fluid region fungtion is for make sure fluid area.

  • @indiegate
    @indiegate 8 месяцев назад +4

    Bad impeller rotation direction

  • @alvaropeiron4218
    @alvaropeiron4218 Месяц назад +1

    HI
    Where do you find and check the efficiency equation?
    Thanks

    • @EngineerKoniago
      @EngineerKoniago  Месяц назад

      Hi bro.
      Efficiency formula is output power / input power x 100%

  • @sealtielabulencia2662
    @sealtielabulencia2662 Год назад +4

    @ 21:50 during run, in the info section it gives me a warning that says "Warning Comment
    Negative pressure Minimum pressure=-1.03487e+08 Pa; dV/V=90.8481"
    How to fix this? I followed all your steps correctly until the first part of the video which is the making of the centrifugal pump. Please help :((

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      maybe you get wrong input in inlet parameter.

    • @sealtielabulencia2662
      @sealtielabulencia2662 Год назад

      @@EngineerKoniago what timestamp is that on the video? is it the inlet in boundary condition?

    • @patrickverdesoto467
      @patrickverdesoto467 Год назад

      in my case is the same it appears like a negative pressure, What I have to do now?

    • @mechegarmez
      @mechegarmez Год назад +1

      the same thing for me, i'm in solidworks 2022 and the part of analysis is different, there is an option with potencial pressure rotation when I do with that it goes negative when i do without it, it goes positive but it doesn't charge in the goal

    • @nanmaisho5197
      @nanmaisho5197 3 месяца назад

      same for me@@mechegarmez have you found the solution ?

  • @iso1556
    @iso1556 2 года назад +2

    Hi sir
    I want to simulate this.
    Can i get modeling part?
    now my task is to design pumps for api610. thank you

  • @RECEPKARA.
    @RECEPKARA. 2 года назад +4

    You should have taken the torque in the Z direction

    • @EngineerKoniago
      @EngineerKoniago  2 года назад

      thank you for the advice, and I will learn more in the next video

    • @mahdielsaid6103
      @mahdielsaid6103 6 месяцев назад

      Hey, can you explain why is it in Z direction?

    • @RECEPKARA.
      @RECEPKARA. 6 месяцев назад

      Since the rotation axis of the propeller is the Z axis in the model, this torque needs to be checked. I recommend you check the axis in the design from the video.@@mahdielsaid6103

    • @nanmaisho5197
      @nanmaisho5197 3 месяца назад

      The torque is always express as a perpendiculare vector to the circular movement@@mahdielsaid6103

  • @munachix
    @munachix Год назад +1

    I want ask about the parameters. What's the head, rotational speed and flow rate? I need it to complete the CFD simulation.

  • @onurkarakurt5284
    @onurkarakurt5284 2 года назад +2

    surface goal of torque must be in Z direction?

  • @javieragama4316
    @javieragama4316 Год назад +6

    Dear friend, efficiency never can be equal or -- even worst -- more than 100%, you made a mistake defining torque in X axis instead of Z. It's the first time I see a forward curved blade impeller for water. Thanks a lot for your video......!!

  • @MihirPrajapati_-sq5ef
    @MihirPrajapati_-sq5ef 2 года назад +5

    Your impeller direction is wrong in design

    • @EngineerKoniago
      @EngineerKoniago  2 года назад +1

      thanks for your advice, it's will better in future

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      Hi mihir i make new tutorial about this.
      i hope you like it
      ruclips.net/video/_qubBlxAiH0/видео.html

  • @yaswanthsai369
    @yaswanthsai369 Месяц назад +1

    How many iterations does it take for 1 hr calculation time

  • @neelrana3078
    @neelrana3078 2 года назад +1

    I'm not able to do flow simulation
    Fluid is flowing from outlet instead of inlet
    Please help me sir

    • @EngineerKoniago
      @EngineerKoniago  2 года назад

      do it from inlet to outlet sir.

    • @devikam9668
      @devikam9668 Год назад

      @neelrana3078 Did u get it right ....cuz even I faced the same issue
      How to make it from inlet to outlet

  • @parthjadhav4501
    @parthjadhav4501 2 года назад +1

    We want DWG file for above pump and impeller.please provide it

    • @EngineerKoniago
      @EngineerKoniago  2 года назад

      need more time

    • @parthjadhav4501
      @parthjadhav4501 2 года назад

      Not DWG file but the model itself even if it is in solidworks if possible provide model asap

  • @marshlicha
    @marshlicha 2 года назад +1

    the calculation is finished without any result. can u help me

  • @patrickverdesoto467
    @patrickverdesoto467 Год назад +3

    Warning Comment
    Negative pressure Minimum pressure=-1.03487e+08 Pa;
    How can I fix it? please help me

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      it means that the applied pressure is too small for the required range, maybe you can improve the parameters

    • @alessandroscardi2210
      @alessandroscardi2210 Год назад

      Hello, thanks for the video: I have the same problem. Which parameters do you suggest to improve? I tried to change the boundary conditions but I couldn't fix it

  • @TigerTiger-cx3ln
    @TigerTiger-cx3ln Год назад +1

    The orientation of the blades is wrong.

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      ruclips.net/video/_qubBlxAiH0/видео.html
      look this.

  • @johncarloongtengco5974
    @johncarloongtengco5974 Год назад

    Cant run mesh,
    Status SOLVER ABNORMALLY TERMINATED! Please contact the support service.
    Geometry is ok when I run Check Geometry.
    What seems to be the problem? Thank you

    • @EngineerKoniago
      @EngineerKoniago  Год назад

      sorry I don't know what the problem is, but try again checking the mesh parameters

    • @johncarloongtengco5974
      @johncarloongtengco5974 Год назад

      @@EngineerKoniago found the problem thanks

    • @chungzhilin1353
      @chungzhilin1353 Год назад

      @@johncarloongtengco5974 hi may I know what is the problem, I can’t solve the problem

    • @johncarloongtengco5974
      @johncarloongtengco5974 Год назад

      @@chungzhilin1353 Found the solution for this from my professor. The Fluid Region must must be bigger than the impeller. Worked For me

  • @rhonaldfuentes2584
    @rhonaldfuentes2584 Год назад +1

    Efficien = 1.7???

  • @Artem-nx3ge
    @Artem-nx3ge 14 дней назад +1

    wrong impeller bro

  • @eurekamemes951
    @eurekamemes951 10 месяцев назад +1

    Warning Comment
    Negative pressure Minimum pressure=-3.65668e+07 Pa; dV/V=84.7305 what shouls i do can you give me step by step process

    • @saurabhninganiya
      @saurabhninganiya 2 месяца назад

      How did you fix it

    • @Kepchunes7
      @Kepchunes7 Месяц назад +1

      I have this warning too. How did u solve it?

    • @Kepchunes7
      @Kepchunes7 Месяц назад

      @@saurabhninganiya Have you found the solution?

  • @ashok305
    @ashok305 Год назад +1

    could you please share the 3D files for us to practice, thank you

    • @EngineerKoniago
      @EngineerKoniago  Год назад +1

      You can Follow my tutorial about Design Centrifugal pump in my channel, just follow it

    • @ashok305
      @ashok305 Год назад

      @@EngineerKoniago , Thank you so much....