Upgrading My Dust Collection Ducting | Airflow Analysis of 6" Ducting

Поделиться
HTML-код
  • Опубликовано: 5 июл 2024
  • This is part two to my dust collection upgrade video series. In the first video I upgraded to a 3 HP two-stage dust collector and had some incredible results, but I knew my ducting was undersized for my system. I finally took the plunge and upgraded my ducting system to 6" and took some measurements to quantify the differnce made. In this video I go through the installation of the system and I analyze the results to develop my concluding thoughts.
    Website: www.eigendesigns.com
    Instagram: eigen_desig...
    TikTok: www.tiktok.com/@eigendesigns?...
    -------------------------------------------------------------------------------------------
    Time Stamps:
    0:00 Introduction
    1:08 Removing the Old Ducting
    1:50 Designing and Installing the New Ducting
    5:50 Airflow Measurements and Analysis
    9:37 Final Thoughts and Conclusions
    -------------------------------------------------------------------------------------------
    Equipment & Tools:
    10” Combination Saw Blade: amzn.to/3o0c3i0
    10” Rip Blade: amzn.to/2Zw55sF
    Woodpeckers Router Table Fence: amzn.to/3AOMW9J
    JessEm Router Table Lift: amzn.to/3ALk2at
    Bosch 2.25 HP Router: amzn.to/3Rwre0g
    Bosch Offset Wrenches: amzn.to/3z28E8M
    Fulton 110V on/off switch: amzn.to/3PorrR4
    Craftsman Air Compressor Set: amzn.to/3kz3zhv
    DeWalt 20v Cordless Drill Set: amzn.to/36Oe9ck
    Microjig Push Block: amzn.to/3uPK2fT
    Festool Equipment:
    Festool Rotex 150 Sander: amzn.to/3DZHdwD
    Festool ETS EC 125 Sander: amzn.to/3payIcl
    Festool Sandpaper: amzn.to/3nUzev7
    Festool Dust Extractor: amzn.to/2Zvi9yB
    Festool Domino DF 500: amzn.to/3Gu9DA4
    Festool Domino Assorted Tennon Set: amzn.to/3FjPHhP
    WoodPecker Equipment:
    12” T-Square: amzn.to/3KcEZxY
    32” T-Square: amzn.to/3T3aOgw
    12” Stainless Steel Square: amzn.to/3SXqGB8
    6” Stainless Steel Square: amzn.to/3K6OTB8
    6” Stainless Steel Delve Square: amzn.to/3QGlznl
    Stainless Steel Delve Square Set: amzn.to/3K6F9H2
    -------------------------------------------------------------------------------------------
    Music Credits:
    Cosimo Fogg - Jazzaddicts
    Damtaro - Nothing
    Lukrembo - Daily
    Lukrembo - Highball
    Lukrembo - Imagine
    Sappheiros - Willow
    Lukrembo - Butter
  • ХоббиХобби

Комментарии • 40

  • @roofermarc1
    @roofermarc1 Месяц назад

    I've recommended Bill Pentz reading on small shop DC. 6'' pipe runs are mandatory in his view! You've done a great job explaining. Thanks.

  • @customgrains
    @customgrains Год назад +2

    Finally Super in-depth analytical video!! Thank you!!

  • @sail4201
    @sail4201 8 месяцев назад

    Very helpful, thanks. I’m going thru the process now and was deciding between 6” and 4”

  • @adamduerr1203
    @adamduerr1203 Год назад

    What a great presentation on your dust collection system. This is very good and really helps to understand how similar situations might influence my own dust collection system. Thanks!

    • @EigenDesigns
      @EigenDesigns  Год назад

      Thanks Adam - I'm glad you found this helpful!

  • @ronjenkins5663
    @ronjenkins5663 9 месяцев назад

    A well thought out design and presentation.

  • @DudeSawdust
    @DudeSawdust Год назад +3

    You are a man of science indeed! Great info and I'll definitely be taking into consideration your final thoughts of advice when I upgrade my dust collection system from my right and left lungs to something more like yours

    • @EigenDesigns
      @EigenDesigns  Год назад +2

      Thanks Logan! I hope there are a few people out there that appreciate the analysis. As a co-worker once told me “In God we trust. All others must bring data.”

    • @DudeSawdust
      @DudeSawdust Год назад

      @@EigenDesigns I read this while at work in my office alone and actually laughed out loud.

  • @juliek1676
    @juliek1676 Год назад

    So many slides and numbers! Wow!!! Great analytics

    • @EigenDesigns
      @EigenDesigns  Год назад

      Thanks Julie, I hope you found this helpful.

  • @SeamlessFab
    @SeamlessFab Месяц назад +1

    I run six inch ducting but I can hear myself whisper with my dust collection on full power. I built a soundproof closet for the DC but I pull air(which is more efficient) instead of a giant blower housed on top of the cyclone blowing air downward, which is an archaic system imo.
    An obscenely loud DC simply isn’t an option for me personally. Especially with the CNC router where it’s sometimes running all day..

  • @KathyAndrew
    @KathyAndrew 5 месяцев назад +1

    Just figure the difference in the area of a circle 4" diameter versus 6". My 3hp cyclone with 6"" pipe does fairly well even with my wide belt sander and edge sander. The 15" planer works well even with 2 gates open. Did have to modify the edge sander port to 6". My wide belt sander had a small opening, and had to cut the opening a little bigger to get 6" connected, and it is the hardest machine I have to collect from. Problem now is a 50 gallon barrel fills very quickly.

  • @thebobloblawshow8832
    @thebobloblawshow8832 Год назад +1

    Great upload. I’m doing mine soon and this has been very helpful. Thanks. 👍👍

  • @AlexK07010
    @AlexK07010 Год назад

    Very informative video. Great job

  • @mark2talk2u
    @mark2talk2u 3 месяца назад

    Nice video. We understand your shop is cramped. Imagine if you could have a straight 10’ run going into the dust collector. No bends; no flex hose. I wonder how much of a CFM increase an ideal layout would add.

  • @elkskiutah8204
    @elkskiutah8204 5 месяцев назад

    wow pretty much the best made video I have watched in 24' sketch up looked so good... your voice and not a wasted word. THat flex to saw stop must be a tripping hazard? I hope you included links so we can get a quick look at 6" spiral pipe costs.

    • @EigenDesigns
      @EigenDesigns  5 месяцев назад

      I am glad you enjoyed it. Yes, the flex hose is a bit of a hazard, but it's only connected when I am using the sawstop. I use some MagPort quick-connect couplings to easily attach and remove the hose when not in use.
      The spiral pipe can be found at Rockler.com at search for spiralpipe. It's expensive stuff, be warned. It's not uncommon to have your ducting cost more than your dust collector. I have been operating this for about a year now and think very highly of the ducting, the blast gates, and the elbows. It's a significant step up from PVC, but you pay for it.
      Have a good day.

  • @PapaFlammy69
    @PapaFlammy69 Год назад +3

    We should most definitely collab at some point! :D

    • @EigenDesigns
      @EigenDesigns  Год назад +1

      Yes we should! Let’s keep in touch:)

  • @wjcraftineer
    @wjcraftineer Год назад +1

    Thanks for the excellent videos and thorough analysis. I really appreciate your precise measurements and the detailed graphs and tables comparing the results.
    However, you forgot one very important tool in your analysis… the “CNC”.
    I have been planning to purchase a OneFinity CNC, but do not yet have any dust collection. I was looking at the smaller Grizzly G0860 (1 ½ HP) dust collector to reduce cost (about $1000 vs about $2200 for G0862).
    What do you think is the minimum HP and CFM needed for the CNC? Did you measure the flow at your CNC?
    What factors compelled you to choose the 3HP G0862?
    Thanks! (I'm subscribing!)

    • @EigenDesigns
      @EigenDesigns  Год назад

      Hey WJ - thanks for your support... it means a lot.
      Regarding the flowrate at the CNC, I didn't measure it for two reason: (i) the ducting run from the dust collector to the CNC is very short and (ii) my CNC already had way more flowrate than it needed.
      Looking at the two dust collectors you mentioned, I think either of those would be plenty for a CNC, provided that you have a good dust boot. Beacuse of how close the dust collection hose gets to the CNC router, the CFMs needed for good dust extraction is much lower than something like a table saw. One thing I would highly recommend is a 4" dust collection hose. I used to have a 2-1/2" hose and it just wasnt big enough.

  • @johnt3461
    @johnt3461 Год назад

    Thank you, this was well done and very well presented. May I ask one question: I want to upgrade to a new 3HP dust collector and I am torn between one like you have, the grizzly 3HP, which is considered a short cyclone design and a longer cyclone like the V-3000 Oneida.
    I hear comments on the lack of separation capabilities on the more compact units. Are you experiencing any poor separation to where your filter is clogging rapidly with the finer dust particles ? Do the longer cyclones actually work better?? I guess thats two questions, sorry.

    • @EigenDesigns
      @EigenDesigns  Год назад

      I personally have never had any issues with poor separation with my shorter cyclone unit. The only time the secondary bag starts to fill up is when the primary bag is full and its time to empty it out. I can see how a taller unit might improve the separation, but it just hasn't been an issue for me.
      I hope this helps you make your decision.

  • @michaelroth5234
    @michaelroth5234 Год назад

    Hi Mr Eigen: I seem to have the same anemometer you have. I have had some challenges using it. In the CFM mode it is 4567 at the end duct the furtherst from the dust collector, and it should be around 440CFM`. And when I put it near the dust collector port it appear to be too strong for a reading. mine is a BT846A.

    • @EigenDesigns
      @EigenDesigns  Год назад

      Hey Micheal, I didn't trust the CFM measurements from the device. In order to calcuate a volumetric flow rate, you need to know the diameter of the pipe, which the anemometer does not. Instead, I took air velocity measurements and then used a spreadsheet to calculate the flow rate using the diameter of my ducting. You should give that a shot and see if that fixes your issue.

  • @stevesiefken2696
    @stevesiefken2696 День назад +1

    Any issue with grounding? I thought metal ducts were prone to static issues.

    • @EigenDesigns
      @EigenDesigns  День назад +1

      I haven’t had a single issue with the grounding. You can certainly add a grounding wire if that’s a concern

  • @tbunton2928
    @tbunton2928 Год назад +1

    I have a single stage d/c with 6" to every machine (including at the machine, no 4") and agree that the larger pipe size is the way to go but only if you're a one man shop. You'd need the 4" at each machine if more than one machine runs at a time though

    • @EigenDesigns
      @EigenDesigns  Год назад

      That’s a good point. The sum of the areas of the open ports shouldn’t exceed the area of the opening going into the dust collector. Thanks for sharing T Bunton.

  • @srhagood
    @srhagood 11 месяцев назад +1

    Any recommendations on who to purchase the ducting from?

    • @EigenDesigns
      @EigenDesigns  11 месяцев назад

      I bought mine from Rockler. They're epensive, but they're high quality.

  • @autoraiders9520
    @autoraiders9520 Год назад

    For some 2” makes all the difference! 😳

    • @EigenDesigns
      @EigenDesigns  Год назад +1

      Especially when 2” doubles your existing system’s capacity. I hope you found this helpful.

  • @DotaBillfuc
    @DotaBillfuc 6 месяцев назад

    Increased cfm means decreased pressure…