Thanks bhai yr m modinagar ke paas bhatjan me rahta hu to yaha kya hota h jaise hi light aati h sb log Samersevil on kr dete h wo pip se pani west hota rahta h halaki hmne to 500 liter ka tank rakha h to hm to use bhar lete h din bhar use karte h lekin kise ek aadmi ko chhat pr khada hona pdta h dekhne ke lye ki tank bhar gya ki nhi apne meri bhut badi problem solve kr di m ese bnaunga thanx bro
Hi, Motor will be switched off once wires short circuit. But once water goes below the wire again motor starts. How does it practically possible. I don't want to switch on motor automatically until tank is empty. I just want a circuit to switch off motor once tank is full. Later once tank is empty I will manually switch on the motor. Any help??
Tink u sir Sir hamny is system ko banai but ye tho tora sa pani kam hokar motar start ho jata hi is kuyi isa system batha k tink half honi k bad motar start hojai tink u sir
Nice and......go ahead 1.motor pump mobile se kaise on off hota hai iske uper ek video jarur banaiyega 2.3phase ko single phase mai convert kaise hota hai.?.. 3.Power low fass hota hai unko sthir kaise kiya ja sakta hai ek video is ke uper bhi bana na good and nice your reply
I have a waterfall, solar. I use this with a smaller pump to refill waterfall tank. You can put a timer on relay to shut off the filling pump after so many seconds.
ashok mukka in the circuit diagram the upper red wire is 12v + wire and lower black wire is negetive input. See the diagram carefully ground sign is given in the emitter of the transistor. Thanks for watching
Sir can you try out with two tanks? Example: one tank in ground floor and another tank in the 2nd floor working: when switching on the pump, the pump will auto turn off when 1. Tank in the 2nd floor is full 2. Tank in the ground floor reaches the bottom line is this possible with single relay? please give me a circuit drawing for this.
+Pravesh krishnan What will be the best option for you 1) Circuit with two relay and two transistor with same schematic. Or 2) circuit with one relay and three transistor and some resistors to fine tune for better result. Finding your next reply.
So base on your first option, first relay in tank 1 will be N/O & tank 2 will be N/C which is connected in series using the same schematic. Am I, right? second option I don't understand :( Could you please hand sketch a simple diagram and send me
imgur.com/ouwSplV Sir, please find the link to the diagram that I have made. please check and let me know if I need any corrections. My PCB board is in progress. Thank you for the kind help.
Diode ki polarity wrong bataye 0.46 sec pr video m dekho signs se aap jb clip m lgaa hua tha relay pr solder krne hi wale the jb jha diode negative likha tha wo diode ka positive hai data sheet se dek lo koi bnayega dek k to uska relay jl jayega smoke nikl jayega
+Syed Hussain As it is DC relay, so you have to manage a dc power source. Otherwise it will burn. You can use a 6V Relay and old cellphone charger to power it. Thank you.
Mayank Agrawal nei aap ise direct use kar nei sakte kiuki e utna load utha nei payaga, aap ka jo starter hai usse use kar sakte ho. Description me jo video link hai usko jara dekhlo.
+Kristofer Valencio Here IN4007 to absorb the voltage produced by back emf of the relay's coil when the transistor is being off BC547 to act like a "SWITCH" 100ohm resistor to limit the current going to the base of the transistor. Thank You.
NC mae connect karenge then pani bharte he off to ho jayega. But jaise he water level thoda kum hoga then again ON ho jayega. Means water level, minimum jane sae pahele he ON ho jayega. So bar bar ON-OFF hota rahega. So its not at all correct circuit.
i can you try out with two tanks? Example: one tank in ground floor and another tank in the 2nd floor working: when switching on the pump, the pump will auto turn off when 1. Tank in the 2nd floor is full 2. Tank in the ground floor reaches the bottom line is this possible with single relay? please give me a circuit drawing for this.
+KBN World Details of relay Input rating. 12v dc Output rating. 250v 7a Or 120v 7a Details of diod 1n4007 Or any 1n4000 series 90v 1a. Thank you for your query.
+Piyush kumar That is why the relay does not take the load of the motor, It just push the { off } switch, the circuit is made in this purpose. And thank you for watching.
+pradeep j Here diode acts like a protector. It absorbs the reverse voltage produced by the relay coil when it switched off and magnetic field collapses.
1.is relay ka nam kya hai 2.motor me currunt pasar karnese jal nahi jayegi? 3.240v pe sidhi chalti hai kya relay? 4.is mai coil likha hua ata hai wo kya hai 5.ye relay kitne watt aur ampier se chalti hai? 6.motor bhi on/ off ho jayegi k bandh karna padta hai? Jarur jawab bheje 7.aapka nam watsapp kya hai? 8.sach mai aise projet banate ho? to reply jarur bheje 9.is relay ki price kitni tak rahegi? mera Watsapp 9824466216 i am waiting
+B Kumar 1.It called relay 2. It only push the ( OFF ) SWITCH. so motor current is not passing through it. 3. No you have to power it from another dc power source. 4. ignore it because the coil is inside the relay. 5. To activate the relay you have to get a dc power source depends on relay's specification and it can handle 220v 10 amps. 6.you just have to on the pump, when the water tank full the pump will automatically be OFF. 9. It will cost around 20 Rs (inr). Thank you for watching
+Tinu Tom Then just put your motor in place of relay. And the diode attached don't place the motor with out the diode, it can kill the transistor. Thank you
+Pradeep Bhaskar This circuit automatically OFF the pump when water tank is full only. And it does not restart the pump, you have to ON the pump when needed. Thanks for watching this video.
Tech Ideas Lekin aapne jo video me bataya, uske mutabik to jaise hi wire paani ke baahar nikala bulb ON ho gaya. Switch off kaise hoga bulb ka main switch
For God's sake take this video down. What you are doing here is very dangerous and it can cause people their life. I am very sure you are aware of the danger if anyone accidentally touch those AC wires (I noticed you acknowledge in the comments). Or at least leave a clear warning that this is not safe in the video and the description.
Vou fazer, se prestar te dou LIKE.
Can i use this for 220 volt AC water pump?
When Tank of water is full to turn of automatically .
Thanks bhai yr m modinagar ke paas bhatjan me rahta hu to yaha kya hota h jaise hi light aati h sb log Samersevil on kr dete h wo pip se pani west hota rahta h halaki hmne to 500 liter ka tank rakha h to hm to use bhar lete h din bhar use karte h lekin kise ek aadmi ko chhat pr khada hona pdta h dekhne ke lye ki tank bhar gya ki nhi apne meri bhut badi problem solve kr di m ese bnaunga thanx bro
oh..thank you so much sir.sir I have one more doubt that which terminal(negative or positive)of the diode I have to connect to the motor
bhai Bhalo Kore prasident
Thanks a lot sir you help me i am your subscriber
+Mayank Agrawal Happy to help you
For 1 hp moter which relay supposed to be use and I no have electricity knowledge so can I go to make this please reply
Hi,
Motor will be switched off once wires short circuit. But once water goes below the wire again motor starts. How does it practically possible. I don't want to switch on motor automatically until tank is empty. I just want a circuit to switch off motor once tank is full. Later once tank is empty I will manually switch on the motor. Any help??
Sir please tell me bc548 use kar sakte hai
Tink u sir
Sir hamny is system ko banai but ye tho tora sa pani kam hokar motar start ho jata hi is kuyi isa system batha k tink half honi k bad motar start hojai tink u sir
The best way to avoid that motor suffered a damage is controlling with a micro pic and a cheap water sensor
Nice
and......go ahead
1.motor pump mobile se kaise
on off hota hai iske uper ek video jarur banaiyega
2.3phase ko single phase mai convert kaise hota hai.?..
3.Power low fass hota hai unko sthir kaise kiya ja sakta hai
ek video is ke uper bhi bana na
good and nice
your reply
+B Kumar
Ok, i will absolutely make this type of video later.
Thank you again.
Is there any method which on off motor after some specific level because it will on off motor with each use
I have a waterfall, solar. I use this with a smaller pump to refill waterfall tank. You can put a timer on relay to shut off the filling pump after so many seconds.
भाई वीडियो तो अच्छा है लेकिन यह फिर से चालू हो रही है मुझे अपने हिसाब से मोटर चालू करना है क्या ऐसा कर सकते हैं
Sir my ac supply is not cutting off
Its is use single phase motor sir say yes or no.
Yes friend
Fine simple
Where should i give 12 v as you shown in circuit diagram in video thesre is no 12 v dc.can u explain it
ashok mukka in the circuit diagram the upper red wire is 12v + wire and lower black wire is negetive input. See the diagram carefully ground sign is given in the emitter of the transistor.
Thanks for watching
Sir can you try out with two tanks?
Example:
one tank in ground floor and another tank in the 2nd floor
working: when switching on the pump, the pump will auto turn off when
1. Tank in the 2nd floor is full
2. Tank in the ground floor reaches the bottom line
is this possible with single relay?
please give me a circuit drawing for this.
I will make the diagram and send you today.
Thank you
hello Sir, I haven't received any email from you for my inquiry. please send me the circuit. thankyou.
+Pravesh krishnan
What will be the best option for you
1) Circuit with two relay and two transistor with same schematic.
Or
2) circuit with one relay and three transistor and some resistors to fine tune for better result.
Finding your next reply.
So base on your first option, first relay in tank 1 will be N/O & tank 2 will be N/C which is connected in series using the same schematic. Am I, right?
second option I don't understand :( Could you please hand sketch a simple diagram and send me
imgur.com/ouwSplV
Sir, please find the link to the diagram that I have made. please check and let me know if I need any corrections. My PCB board is in progress. Thank you for the kind help.
Sir, here which rating relay u used 6v or 9v?
You can use any, it depends on which voltage you are feeding
Can we use bc548
+techniques at home
Yes, it will work fine.
Sir i want to work in reverse order...automatic motor start when tank is full.. to empty it...and when tank is empty then motor stops
Thanku yr are great
Diode ki polarity wrong bataye 0.46 sec pr video m dekho signs se aap jb clip m lgaa hua tha relay pr solder krne hi wale the jb jha diode negative likha tha wo diode ka positive hai data sheet se dek lo koi bnayega dek k to uska relay jl jayega smoke nikl jayega
ভাইয়া আপনি রিলের ভোল্টা ভালভাবে দেখাপবেন, এমনকি সব জিনিসের নাম উল্লেখ করে দিলে ভাল হয়।
is it dangerous to touch the water when the wires touch the water? please can you tell me?
+David Sailo
No, it is not dangerous. Just solder the AC wire to the relay safely.
Tech Ideas thanks... i will subscribe ur channel
+David Sailo
Thank you very much
This product were which can buy tell about the project
which diode u used.is it in14007
+Tinu Tom
Yes 1n4007
Samar sivar pump ke leye Kitne voltage ka relay use hoga
good video I like it the best video auppper
+chathuranga sampath
Thank you very much
12 volts dc I used for relay burnt the transistor what shall I do??
Bhai ismey battery se supply h ya electrical supply h
+Shameem Rajpoot
Any power source will work.
Nic idea its warking 220E resistor
+Mansing Sawant Thank you
Tink u sir we need for 2HP motor
+Syed Hussain
Welcome
tank u sir agar ham in put mie power k lay DC k jaga AC 220 dingy to kiakarna hoga plz reply sir
+Syed Hussain
As it is DC relay, so you have to manage a dc power source. Otherwise it will burn.
You can use a 6V Relay and old cellphone charger to power it.
Thank you.
Sir pls show the detail plug wire&bulb wire
It's not appear clearly
Sir isko direct sumbersiver pump me ise kar sakte h kya
Mayank Agrawal nei aap ise direct use kar nei sakte kiuki e utna load utha nei payaga, aap ka jo starter hai usse use kar sakte ho. Description me jo video link hai usko jara dekhlo.
ELECTROD PALL sir matlab starter pe ye relay lagana h jaise apka next video me h
ELECTROD PALL sir circuit yahi h na uss video m
Mayank Agrawal ha yehi circuit use kiya hai.
sir,can you explain to me why you use IN4007 diode,bc547 transistor,and 100ohm resistor?
+Kristofer Valencio Here IN4007
to absorb the voltage produced by back emf of the relay's coil when the transistor is being off
BC547
to act like a "SWITCH"
100ohm resistor
to limit the current going to the base of the transistor.
Thank You.
thank you very much for your explanation
and can i use 1N4002 diode?
+Kristofer Valencio yes,you can use IN4002 .
Sir were we want to connect two rose wire
in sab ka price kaya hoga
Sir Ye circuit katne AC voltage manage kar sakta h
Prabhu Kumar it depends on your relay's specification.
Sir i want to work with 24v bc pump it will work
+prashanth sr
Yes it will work
half hp motor ke sath connect kar ne par kya ye load uthaega. Jal to nahi jayega
+Rajnish Prakash nei e jal nahi jayega,
ELECTROD PALL . Par aap to 12v relay use kar rahe ho
Rajnish Prakash motor directly to relay se joora nei hoga. Relay se jo two wire nikal raha hei wohi wire starter ke OFF switch ke series lagana hoga.
ELECTROD PALL . Thankyou
Contractor use karo or 12 volt ka
Bhai me aapse trika poochna chahta hoo ki jissy ki pani ka pump automatic off ho jaay (automatically on na hoo)
+Naved Ali
Eh circuit to wohi kaam karta hai
Bhai es se pani me carunt to nhi aayega na?
Nei es se pani me current nhi ayega.
12 volt adapter whtat ampere will be suitable to make like this
1A or even 500mA will work
thanks
Black aur Red wire kahaan lagaya hai??
if we dont have bc547 then?
+Zahid Hussain you can use any NPN transistor whatever you have. Just connect the pins correctly, I mean ECB of the transistor.
Kitna volt suplay Dena he 12 volt or 220
+Anuj Kumar it depends on your relay voltage ,if using 12v relay then supply voltage also be 12v and if 6v then 6v.
Where are other 2 wires go
12v supply
Vai pani me correct nahi hoga na..
NC mae connect karenge then pani bharte he off to ho jayega. But jaise he water level thoda kum hoga then again ON ho jayega. Means water level, minimum jane sae pahele he ON ho jayega. So bar bar ON-OFF hota rahega. So its not at all correct circuit.
No, you have to manually ON the pump switch to restart
sir your resistor 220 is what ampere
1/4 watt
Tink u sir but this rely will be work for 2hp motor
+Syed Hussain
It does not matter what HP motor you are using. Because the relay is connected to the starter.
Sir next video jaise fit kar du circuit ko
+Mayank Agrawal yes
i can you try out with two tanks?
Example:
one tank in ground floor and another tank in the 2nd floor
working: when switching on the pump, the pump will auto turn off when
1. Tank in the 2nd floor is full
2. Tank in the ground floor reaches the bottom line
is this possible with single relay?
please give me a circuit drawing for this.
Please tell me the rating of relay and diode
+KBN World Details of relay
Input rating. 12v dc
Output rating. 250v 7a
Or 120v 7a
Details of diod
1n4007
Or any 1n4000 series
90v 1a.
Thank you for your query.
Can we use it in direct water line when ever water reach motor gets starts and no water no dry run
water tank overflow moter is automatic off only circuit diagram
Ye submarcibal pump me kese work karega
Relay kitnee watt ka he
5 amp's per to ye relay jal jayegi...
+Piyush kumar
That is why the relay does not take the load of the motor, It just push the { off } switch, the circuit is made in this purpose.
And thank you for watching.
Men bord me to line aa gya
Pr jo red and black wire Kahan gaye hain.
+Deepak Rajbhar
To water tank
How to make more strong signal for long distances
You have to increase input voltage
And decrease the base resistor
But careful with relay's max voltage
bhai mene 12 v relay use kiya or 12 v ki supply di pure tank me current h jor ka
Anyone tell me why we are using a diode here ...
And diode polarity also gets reversed...
+pradeep j
Here diode acts like a protector. It absorbs the reverse voltage produced by the relay coil when it switched off and magnetic field collapses.
Tank mai इससे बिजली ka जोर ka झटका लगेगा
aapne Jo Banaya wo to sleep on of Karta Hai aap ye Bataye Sharif Moto off Hoga on nahi hoga aap Aisa kuch Bana kar dikhaye
How To get bc547 transistor
+Vanshdeep Manerao
You can use any low power transistor whatever you have.
Yeh waqti totka hy proper long time nh chalti
+Electric guidance
In my home it's working since 3 years without any problem.
Thank you for watching the video.
Tech Ideas chalo bhai tajerba kr k dikh lite hn
ما فائدة الدايود
To protect the relay from voltage surge
1.is relay ka nam kya hai
2.motor me currunt pasar karnese jal nahi jayegi?
3.240v pe sidhi chalti hai kya relay?
4.is mai coil likha hua ata hai wo kya hai
5.ye relay kitne watt aur ampier se chalti hai?
6.motor bhi on/ off ho jayegi k bandh karna padta hai?
Jarur jawab bheje
7.aapka nam watsapp kya hai?
8.sach mai aise projet banate ho?
to reply jarur bheje
9.is relay ki price kitni tak rahegi?
mera Watsapp 9824466216
i am waiting
+B Kumar
1.It called relay
2. It only push the ( OFF ) SWITCH. so motor current is not passing through it.
3. No you have to power it from another dc power source.
4. ignore it because the coil is inside the relay.
5. To activate the relay you have to get a dc power source depends on relay's specification and it can handle 220v 10 amps.
6.you just have to on the pump, when the water tank full the pump will automatically be OFF.
9. It will cost around 20 Rs (inr).
Thank you for watching
sir can you please make the circuit diagram without relay.Because I want to rotate only a dc motor
+Tinu Tom
Then just put your motor in place of relay.
And the diode attached don't place the motor with out the diode, it can kill the transistor.
Thank you
Very dangerous mode
Koi faida ni yy. Agar motar 1 war band hoke dwara na chlee too manuu ap koo
ok..
Its not fully automatic
it's not working
When water level goes down the pump will start. So its not usefull.
+Pradeep Bhaskar
This circuit automatically OFF the pump when water tank is full only.
And it does not restart the pump, you have to ON the pump when needed.
Thanks for watching this video.
Tech Ideas Lekin aapne jo video me bataya, uske mutabik to jaise hi wire paani ke baahar nikala bulb ON ho gaya. Switch off kaise hoga bulb ka main switch
विजय जैन same
hello bhai mere paas aap call kar sakte hain kya aap apna number de sakte please
Kyo logoko chutiya banate ho yarr..
Black aur Red wire tumne use nahi kiye ....tumne direct connection liya
For God's sake take this video down. What you are doing here is very dangerous and it can cause people their life. I am very sure you are aware of the danger if anyone accidentally touch those AC wires (I noticed you acknowledge in the comments). Or at least leave a clear warning that this is not safe in the video and the description.
It is waste of time
Bekaaar