Can you explain please why first you have to unmount the main tube (leading to the E61 brewgroup)? Second question: can the valve be cleaned or repaired instead of being replaced?
I have a question about the Elizabeth. I just noticed when running a shot my pump pressure moves slighty up and down throughout the shot. I can't tell if this is normal or not i just noticed it doing it last week.
Hi, I have a Lelit Bianca. I was trying to replace the safety valve (to solve my constant steam/water leak issue), and it absolutely refused to unscrew and I ended up ripping it off the T junction. I have ordered a replacement T junction, but do you have any tips for replacing it? The stiff wire attached to the top moves if I try and unscrew it and I think will just damage/pull apart if I keep unscrewing. Best wishes, Finn
@@lelitinsider2977 Thank you so much for the reply. I have actually managed to find the part and order it, and also remove the broken T junction. So crossing my fingers that putting in the new one all goes well!
@@wytstripedhow did you know it’s the safety valve? I have constant steam leak but 3 pipes are going to this outlet. Can be also the other valves, right? How did you distinguish? Greetings Matt
Can you explain please why first you have to unmount the main tube (leading to the E61 brewgroup)?
Second question: can the valve be cleaned or repaired instead of being replaced?
I have a question about the Elizabeth. I just noticed when running a shot my pump pressure moves slighty up and down throughout the shot. I can't tell if this is normal or not i just noticed it doing it last week.
is this can install on marax?
or marax use 9700043
still marax uses the 9700050!
Do you have a video on how to change the pump.
in bianca or elizabeth?
Hi,
I have a Lelit Bianca. I was trying to replace the safety valve (to solve my constant steam/water leak issue), and it absolutely refused to unscrew and I ended up ripping it off the T junction.
I have ordered a replacement T junction, but do you have any tips for replacing it? The stiff wire attached to the top moves if I try and unscrew it and I think will just damage/pull apart if I keep unscrewing.
Best wishes,
Finn
please send an email at care@lelit.com , send us a photo of the problem
@@lelitinsider2977 Thank you so much for the reply. I have actually managed to find the part and order it, and also remove the broken T junction. So crossing my fingers that putting in the new one all goes well!
@@wytstripedhow did you know it’s the safety valve?
I have constant steam leak but 3 pipes are going to this outlet. Can be also the other valves, right?
How did you distinguish?
Greetings Matt
9700052 is that the correct part number?
for bianca yes
@@lelitinsider2977 I thought the 9700052 is the vacuum breaker valve whilst the safety valve is 9700050?
@@arnold.pangilinan yes, it is true
sorry is 9700050
wich maschine is it ?
Lelit Bianca V3