With the lamp method, I think when you connect a phase with earth ,you are creating an earth fault , and I think that lamp will just blow. Explain more!
Thanks so grateful for sharing this. Pls voltage of P-N and P-E are almost the same, at what point does neutral is connected to earth. Pls I need clarification. Thanks
Thank you for the quick explanation. I saw your other video on using Capacitor for power factor correction. Which Capacitor is to be used and what is the MFD etc to check and buy for the installation? can you guide 🙏
hi, i have tested using the methods which you have shown and its all ok like you said but the voltage between neutral and earthing is 3 volts, i am getting shock from touching appliances like phone charger and the body of my computer can you explain why is that and how can i fix it?
If we are not getting almost the same volt with neutral and line when checking the earth. Does it mean that the salt we have used for our earth rod is not ok or working well? What should we do about it?
Between my earth and neutral are showing Zero volts in multimeter is that ok? cos i saw in some video that 0 volt is also not ok is that true ?? The rest Earth and phase , phase and neutral are all fine.
Our panel light chokes keep blowing up after a few minutes of switching on the light meanwhile other appliances are not affected what can we do to resolve this fault?
Voice with valuable information ❤❤❤
Very beautiful knowledge sir
So clear and easy to understand. Have subscribed since last month when you talk about MCB, ECCB, MCBO etc which is so easy to understand.
Useful info video.
Good explained.
Great information!!!
Very informative. Thanks for sharing this
What a great simple way to test your earth circuit. 😊😊😊
Very useful. Thanks
bro, you explained it in very good way. thanks
Is this method applicable for industries and factories
Easy understanding
Tks very much.
Good ❤
thank you man
Thanks 👍👍
With the lamp method, I think when you connect a phase with earth ,you are creating an earth fault , and I think that lamp will just blow. Explain more!
It can't blow bcz earth and neutral are related
Thanks very much
Thanks so grateful for sharing this. Pls voltage of P-N and P-E are almost the same, at what point does neutral is connected to earth. Pls I need clarification. Thanks
Thank you for the quick explanation. I saw your other video on using Capacitor for power factor correction. Which Capacitor is to be used and what is the MFD etc to check and buy for the installation? can you guide 🙏
it's for a home with a single phase connection. I observe frequent fluctuations. Below 200 V is what sometimes it happens.
hi, i have tested using the methods which you have shown and its all ok like you said but the voltage between neutral and earthing is 3 volts, i am getting shock from touching appliances like phone charger and the body of my computer
can you explain why is that and how can i fix it?
you have to do earthing in your home call a certified electrician and do the process they will install a aluminium rod
pl tell me how to find out which wire is neutral and which one is earth in the absence of color code excluding test lamp method
While checking neutral and earth if not getting any reading means? what's the reason?
Good
super
If I have battery bank which voltage is 117Vdc, what will voltage be measured between positive and building earthing terminal?
How can we determine Earth wire and The Neutral wires?
How do you bury a proper or effective
How to correct it sir
If we are not getting almost the same volt with neutral and line when checking the earth. Does it mean that the salt we have used for our earth rod is not ok or working well? What should we do about it?
what if i use my device with line and earthing point, as line- neutral and line-earthing have the same voltage?
What textbook (s) by an indian authors would you recommend for an electrician?
Ok thanks
Between my earth and neutral are showing Zero volts in multimeter is that ok? cos i saw in some video that 0 volt is also not ok is that true ?? The rest Earth and phase , phase and neutral are all fine.
🎉
Is it normal to have 40 ac voltage between earth and my monitor dc jack + or - ?
Please brother small question
Bhai switch off me bhi thoda thoda glow kar raha hai to kya kare?
Our panel light chokes keep blowing up after a few minutes of switching on the light meanwhile other appliances are not affected what can we do to resolve this fault?
This bring about my next question. How do you bury effect earth
Hello there. I tested the voltage between the live wire and the earth wire and it was give me above 400Volts.
is your house a power station?!😂😂
just kidding
hiw to check it in a mechanical meter
So in case there a fault or the earthing in our homes is not proper, how to we go about it thanks
Call an electrician.....
CURRENT KILLS
Neural to phase and phase to earth is same,(230v)
But neutral to earth getting Zero
What is the reason sir?
red needle to neutral + black needle to earth
my readings is 001 to 004.. what does that mean?
What if the voltage gives 200v and the earth gives 298v
neutral must have zero volts when other test prod is connected to earth cause earth & neutral is connected on same terminal.
I do not understand how do you know that neutral is not ok in ma room
So many stupid questions....if you don't understand then don't attempt to do it...
CALL AN ELECTRICIAN...
SAFETY IS PARAMOUNT
Good explained.