Dangerous Electric Work Earthing Connection With the Busbar।Electric Work with Expert Electric Men
HTML-код
- Опубликовано: 11 фев 2020
- how earthing works animation,
how does earthing work,
what is earthing,
importance of earthing,
tncs earthing system,
types of earthing ppt,
what is earthing and types of earthing,
pipe earthing,
what is earthing in electricity,
what is earthing and types of earthing,
importance of earthing,
earthing definition,
types of earthing pdf,
types of earthing ppt,
earthing systems diagrams,
advantages of earthing,
earthing systems diagrams,
earthing system pdf,
importance of earthing,
earthing definition,
what is earthing and types of earthing,
types of earthing ppt,
earthing system design,
advantages of earthing,
#Earthing_System_Installation
#Earthing_Desing
#Electric_Earthing_System
For people who ask or want to know why this is ULTRA dangerous,here is your answer:
Besides from Connections etc
1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance..
2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black..
My mind and intuition whispers that this type of work requires a technically equipped professional who does the job. Reading, watching and educating yourself about earthing regulations in an hour will tell you so.
its perfect to us the electricians.........
Thank you
ধন্যবাদ
4:12 mistake !: don't cut and use longer copper wire to increase the touching surface between wire anr the copper rod.
Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.
@@learnpassearnprofessional7467 i call every people in Turkiye right now to watch this video buddy. Hold tight
You should put this covered cable inside the anti-humid tube ( Foroplast tube.
These guys do not know the basic theory of earthing in Electrical work.
Hi, can I make the pipe earthing near my plastic water tank ?
Will it be safe?
Please reply
Rods are wrong diameter 5/8 or 3/4 needed. cable too small 6awg-2awg
how is this wrong, drive the rod in the ground connect the wire to main panel. seems simple
Electric room to earth menhole how many meter fixed?
Thank you
Please add english subtitle
Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.
This guy is not a Electrician.
you need more tools...
Thank you so much for your comments. Please share our videos to your friends and country. Like us, comment us and subscribe to our channel.
Very bad connection , chance to loose anytime between rode and wire
May I please know why these earthing is wrong and dangerous.
This
@@BarryBollox. For people who ask or want to know why this is ULTRA dangerous,here is your answer:
Besides from Connections etc
1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance..
2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black...
@@samuelkatherinediozarago7692 thank you
Copper rod earth
Thank you for your comments. Please share our videos to your friends and country. Like us, support us and subscribe to my channel.
how much deep in the earth muss the electrode conductor?
thanks mate
Thanks dear for your comments. Please share our video to your friends and country. Like us comment us and subscribe us
the green tape makes all that crap work much better ,how about using an electrician with experience
🤭🙄🙄🙄cap and jacket are in proper way but not earthing
Ye konse engineer he electric to nai lag rahe
Shuhada,, maskara,, siokol,,, Mafi mukh.
Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.
Misleading video, one rod is definitely not meeting the standards, minimum 2. When i started watching this video, i would expect them to measure the earth resistance using the earth resistance meter, if it meets 10 ohms and below, it is acceptable, of course the best is 5 ohms and below, the lower the better. If it doesn't meet, what is the next course of actions? This video doesn't show all these steps and recommendations such as how to improve the resistance by using GEM, copper mat and etc. One more thing, the ground wire clamping looks so flimsy, if someone dig the soil and accidentally pull the wire, the ground wire is slip through the grip. It is waste of time watching this.
Thank you
This is terrible ! Extremely poor work with no understanding of electrical engineering standards.
Please explain.
Totally wrong
Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.
This is not a right method.
Please Explain
it is not good job.
Thank you
@@learnpassearnprofessional7467 Look at my video, connect the earth electrode underground with a flat bar, not a cable.ruclips.net/video/2tqXiqoiQz8/видео.htmlsi=Nw_muE2qu6W8lOVB
Unprofessional
Please explain
This is very professional . You just missed the point where he says it's a barbeque .