Push fit fitting pressure test

Поделиться
HTML-код
  • Опубликовано: 5 янв 2025

Комментарии • 354

  • @gerrybhoy7124
    @gerrybhoy7124 9 лет назад +6

    Spot on mate
    Push fit connections are good enough for anyone's house.
    Having used them for many projects I can highly recommend them.
    One of my biggest worries was will it leak!
    Every time I have used push fit connections they have never failed unless you don't push it home properly.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +gerry bhoy Thanks, I'm a lot more comfortable using them now after doing this test!Thanks for the comment ;-)

  • @zedman442
    @zedman442 9 лет назад +47

    The problem us plumbers have with push fitting is the longevity of them. There is never really an issue with these and how much pressure it can hold its more to do with when its left in place and over many years the fitting degrading due to the rubber seal. Unlike a fixed soldered joint where you can have piece of mind, then again saying that I still use these on occasions. Great test as usual! Thanks. 😀

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад +10

      +Zed Man I must admit that I recently had a problem with a toilet fill valve, where the plastic threads went soft on the end. This caused the washer to fail and the nut to leak, which was very annoying after just three years. Every time I fit a water fill valve from now on I'm getting one with brass threads!Thanks for the comment ;-)

    • @Billyg215
      @Billyg215 4 года назад +2

      Got to say you are right there Plastic degrades a LOT faster than copper.

    • @malloot9224
      @malloot9224 4 года назад +1

      @@Billyg215 Well that really depends on the system, without proper precautions regarding galvanic corrosion metal fittings can be gone in months were you never have to deal with that with plastic.

    • @andybanov4319
      @andybanov4319 4 года назад +1

      @@malloot9224 Had loads of hep fittings failing (grey older version) on an estate near me recently on 22mm heating pipes the metal rings seem to be failing

    • @chrisma1976
      @chrisma1976 4 года назад

      These are great. The problem with copper tubing isn’t the joints, it’s the flux destroying the pipe slowly creating pin holes. No flux means the tubing is preserved longer right?

  • @daved4547
    @daved4547 7 лет назад

    I found out how good they are when I went to cold pressure test a boiler and forgot the filling loop was open. One of the lads told me the boiler was leaking and after 'dissing him', I remembered about the test! The boiler had reached it's maximum pressure and the relief valve had opened (correction needed if a 'correct' term is known!). We went and checked every joint on the heating system and it was fine, hence, I swear by them now as I know what they can take (and more so now) Some great tips you keep showing, so thanks for them as you are never to old to learn new tricks.. :)

    • @ultimatehandyman
      @ultimatehandyman  6 лет назад

      "relief valve opened" sounds fine to me, or relief valve discharged.
      That reminds me of one particular relief valve at work, it is only a small one weighing a couple of kilos. It was sent to be calibrated one year and I refitted it and after de-isolating the steam line there was a drip from the end of it, so I thought some crap was stuck under the seat so I pulled the manual relief lever and the whole room was full of gushing steam within a fraction of a second. When I told a couple of the other engineers on site, they laughed because all of them had done exactly the same as me at some point!
      Thanks for the comment

  • @Blaggsta
    @Blaggsta 9 лет назад +2

    very glad you did this test because I used these fitting to re-plumb my friends header tank and also my bathroom... I knew they must be good because they have been around a while but it's always reassuring to know the ultimate breaking strain

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Adam B Absolutely. They perform much better than I expected them to do for a bit of plastic!Thanks for the comment ;-)

  • @edwardking6841
    @edwardking6841 5 лет назад +6

    Great videos. And well done for not adding background music. It's unusual these days to find a video without drumming in the background.

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Thanks for the comment 👍

    • @graymondgreaves8
      @graymondgreaves8 Год назад

      here here, 'groovy' music ruins many tutorials, also science lectures and discovery channel documentaries...some are unbearable. Good information is all we want, not some idiot adding a sound track...

  • @rdbanks2823
    @rdbanks2823 5 лет назад +9

    I’d have never guessed that high! awesome!
    Thanks to Big Clive for linking this!

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +2

      Yes, I did not expect it to hold that much pressure!
      Thanks to Big Clive also ;-)

  • @Flashdan100
    @Flashdan100 8 лет назад +1

    Very impressive , I am about to use two of these in a place only accessible with push fittings so the test gives me the confidence to carry on.

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад +2

      Sometimes they are the only fitting you can get on the pipe in difficult locations.
      Best of luck with it ;-)

  • @TheViking2008
    @TheViking2008 2 года назад +2

    Just put my mind at rest re plumbing my narrow boat,excellent video thanks so much.

  • @s13ca18s13
    @s13ca18s13 6 лет назад

    Cheers I was worried about my house as it's about 20bar pressure here being near the dam. I still am putting a reducer on to protect my appliances. But glad to see these live up the their name. Good video

  • @charlesxix
    @charlesxix 7 лет назад +18

    I was sat waiting and cringing for the screen to go on my tablet, a good test.

  • @simonpidgeon949
    @simonpidgeon949 2 года назад

    Thank you you have restored my faith in these fittings 💯👍👍

  • @Qwcgvv
    @Qwcgvv 4 года назад

    My house is 20 years old and never had a leak and it's mostly the older grey push fit pipe with the brass collars and I'm only now replacing a kitchen tap with the JG push fit collars.

    • @ultimatehandyman
      @ultimatehandyman  4 года назад

      John Guest make great products ;-)
      Thanks for the comment

  • @jsof2
    @jsof2 7 лет назад

    As someone who's never used push fit I found this video fascinating. I'm a convert! Thanks.

  • @gazs7237
    @gazs7237 7 лет назад

    as a plumber who uses push fit on installations im always wary of them. this has eased my mind. thanks. im shocked it took so much. military submarines cant take that much!!

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад +1

      I was surprised at how much pressure it held.
      Thanks for the comment

  • @amorphuc
    @amorphuc 5 лет назад +18

    Wow. That's amazing. I was beginning to wonder if the copper pipe would fail.
    Big Clive sent me.

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +2

      Yes, it took a fair bit of pressure!
      I'm off to thanks Clive ;-)
      Thanks for the comment 👍

    • @jeremey2072
      @jeremey2072 2 года назад

      @@ultimatehandyman he sent me too (2 years later)

  • @mikezeke7041
    @mikezeke7041 9 лет назад +1

    as a plumber I've been loving these videos

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад +1

      +Mike Zeke Thanks Mike, I will be making a few more of these when I get chance ;-)

    • @feolender2938
      @feolender2938 5 лет назад

      Obvs in between polishing your bentley

  • @WissenSie
    @WissenSie 8 лет назад +10

    The simple pressure resist the fitting, but how it looks, as assayed with contstantly variable temperature. How it works in the heating tubes over the years, how does the rubber seal?

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад +2

      These fittings are normally reliable, although the sealing O ring may perish over time. We use similar joints on site for pneumatic systems and many of the joints are 25 years + in age and are still sealing fine, although you do get the odd one that leaks.

    • @WissenSie
      @WissenSie 8 лет назад +1

      Thank you

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад +1

      You are welcome.

    • @KEW1945
      @KEW1945 7 лет назад +2

      It took 17 years for my main push connect compression coupling to fail, the sealing O ring went bad and that's all.. The plastic compression couplings was big bulky things back then, I took it in to get it replaced and the hardware store helper didn't know what it was lol..

  • @heavydiesel
    @heavydiesel 9 лет назад +11

    I was surprised how much pressure it took before failing!
    Recently had to replace a heater i installed 12 or so years ago, a lot of the internal parts in the Hep20 fittings had become soft and could be crushed between your fingers, i'm just not convinced plastic has the life span we expect from pipework, especially if its under floors or in walls where it could do a lot of damage if it leaked, the repair costs would be well above what was saved on original install over a copper system.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад +2

      +heavydiesel That's interesting to know. I have seen some plastics go brittle over time but I always thought it was because the UV light attacking it. In the last house I renovated I used just two lengths of plastic John Guest pipe as it was in an area where the copper pipe used to get condensation on it a lot. Hopefully it will outlast me!Thanks for the comment ;-)

  • @lawrenceogden8682
    @lawrenceogden8682 4 года назад

    i was in at Lucas CAV Sudbury in 1982 they had a bosch thermal machine the mains gas was pumped by a compressor to the thermal machine they did the pipework themselves and pressure tested 15 mm copper soldered pipe to 900 PSI

  • @SwimBikeRunFastest
    @SwimBikeRunFastest 9 лет назад +3

    Great test but I think people's concern with push fit is the lifespan of the rubber seal rather than the pressure they can take. As always great videos, thank you for uploading.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад +3

      +Chris Campos Yes, A big problem with them is that they are often used incorrectly. I have seen them used on Chrome pipe before and also used on plastic pipe without the pipe insert, which would surely lead to a flood eventually! I'm not sure how long the sealing ring would last in these fittings, but you would imagine that it would wear due the expansion and contraction of the pipe.Thanks for the comment ;-)

  • @MisterAngry1965
    @MisterAngry1965 9 лет назад

    I was really impressed, I'm currently installing new pipe run for our washing machine and an additional sink and was debating with the lads at work whether to use these new fangled plastic push fit joints and decided not to and buy the copper compression ones.
    Should have watched this 1st.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Chris L
      I was surprised how well they performed!
      Thanks for the comment ;-)

  • @TheHairyHound
    @TheHairyHound 7 лет назад

    Have to agree with you Roy Wrenn and many others. Twas a fair and honest test BUT.... It's clear that "Taking care" is something missing from this otherwise great video.
    I would never recommend holding anything in your hand while pressure testing nor would I have anything tested to "POP" leaving to chance that it will not cause injury or death (If you think that sounds extreme; you'd never dream of pointed the end towards your head while testing! Would you?)
    I don't mean any of my comments to be critical other than to say that health and safety should ALWAYS be priority No.1. Maybe then many of the cowboy builders who do all quality tradesmen or even handymen a discredit.
    The product test was better than brilliant and would serve to give anyone a great confidence towards using these push fittings.
    Thank you for sharing.

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад +1

      I do pressure testing regularly and pressure test to much higher pressures than in this video.
      I don't think most people are aware that if something fails the pressure is immediately lost and so the likelihood of any harm is miniscule. Obviously the push fit fitting on the end of this pipe is going to pop off at some point at speed, but it's hardly going to damage anything unless you point it at someone's eye without safety glasses on.
      Pressure testing rigs do not have the volume of water behind them to do any real damage. When we pressure test piping on site or vessels if something does go wrong you normally just get a slight leak of water until the pressure goes to zero. The largest vessel I have pressure tested held 200 tonnes of water, so pressure testing a push fit fitting on some 15mm pipe is really not a risky test for me.
      Thanks for the concern though ;-)

  • @edwarddevon5499
    @edwarddevon5499 7 лет назад +1

    I have to cap two pipes off tomorrow. I'm glad I saw this video. Thanks!

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      You are welcome.
      Thanks for the comment

    • @edwarddevon5499
      @edwarddevon5499 7 лет назад

      Bit of a first time disaster for me, but all good now. I had to remove a sink, and cap off the pipes that were left. I cut the pipes to make them parallel with the wall, but with it being a "T" section, there wasn't enough pipe left to put the cap on for a full fit. When I turned the water back on, it gushed everywhere. To make matters worse I had to turn the water off on the whole wing, so all the showers, toilets, sinks and baths had no water including the kitchen, AND I had a care assistant stood behind me putting pressure on me and another carer doing the funny "I need a pee" dance! I shut the water back off, and cut a small section out of the wall, revealing a longer length of pipe. I quickly cut it and put the end cap on that. It worked a treat thank my lucky stars! You'd think that would have put me off, but I had another sink to do and the capping off worked perfect. So thank you again for this video *Note to self - Watch the whole video properly!* lol!

  • @Simbostyle
    @Simbostyle 9 лет назад

    One problem with push fit is oxygen ingress through the fittings which can lead to central heating systems sludging up if there is not enough inhibitors added. I prefer end feed capillary and copper pipe, but plastic plumbing systems have a place in the industry. Another great video!

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Simon Naylor
      Thanks Simon, I was not aware of that!
      Thanks for the comment ;-)

  • @marhar2
    @marhar2 5 лет назад +1

    Came here from Big Clive. Impressive demonstration!

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Give my regards to Big Clive ;-)
      Thanks for the comment

  • @alanbyrne8767
    @alanbyrne8767 3 года назад

    After 12 years in my domestic house, I had to replace a plastic fitting. After conducting my research with 3 plumber supply stores. 2 stores had stopped stocking the plastic fitting and only supplied the old school brass and copper types because of negative feedback
    1 store owner advised me to lift the attic floor boards (bungalow house with pipe running over head for the radiators) I was lucky to find 3 more plastic fitting out of 16 ready to slip off!! These plastic fittings expand a little tiny bit over time when the hot water passes through, they are supposed to tighten up again as they cool down. After 12years they no longer tighten up by themself and caused a ceiling leak
    I have now replaced the plastic fittings to brass fittings and I expect get around 30+ years of piece of mind out of them.

  • @tellylgeorge
    @tellylgeorge 7 лет назад +1

    Great video. Definitely instilling more confidence in the plastic push fit fittings.

  • @jasonlaverty76
    @jasonlaverty76 8 лет назад

    Cheers for that, always been a doubter of plastic push fits, but this video has al-aid my fears. I will be using them in future when plumbing hard to reach installations ie between walls and baths etc.

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад

      +jason laverty You are welcome. Sometimes push fit is just so easy, especially like you point out in difficult to reach situations.Thanks for the comment

  • @pb2067
    @pb2067 7 лет назад +2

    Thanks for this video i am impressed what pressure they can handle .... copper piping and joints your days are numbered

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      You are welcome.
      I think copper pipe and fittings will be around for a long time as they are still the pipe materials of choice for most plumbers.
      Thanks for the comment

  • @Ivan.Atanasov.
    @Ivan.Atanasov. 4 года назад

    I wonder if you would have access to copper press fittings and tool to preasure test it. Couldn't find a good video in the tube

    • @ultimatehandyman
      @ultimatehandyman  4 года назад +1

      I only know one person that uses press fit. I might see if we can test them one day ;-)
      Thanks for the comment

  • @danemma3610
    @danemma3610 7 лет назад +7

    Such a tense video.

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      Thanks for the comment

    • @tomas7655
      @tomas7655 6 лет назад

      Yes it was. lf it was a pneumatic test, l would have been out of the room at 10 bar...

  • @andrewbremner7150
    @andrewbremner7150 9 лет назад

    got to say a always find your video very interesting and educational.i personal only ever use push fittings on area were a can gain easy access to it .personal a think its cause am one of the people that don't trust them .but a personal a well a loads of skill has went of of plumbing jew to the fact of push fit fittings and plastic pipe .a remember spending many hours at college making pass over and offset and other types. was very surprised how much pressure that fitting mange to take . a defo agree with your previous comment copper and solder fittings are better

  • @drcl7429
    @drcl7429 11 месяцев назад

    was a plastic part that failed, not the seal and not the teeth. If the same test was done with a straight connector in situ it would take even more pressure. I am one of those people who look at push fittings and think how could that possibly work? For me there are no questions that need answering anymore. It's no wonder you see them everywhere in hidden locations.

  • @thpxs0554
    @thpxs0554 9 месяцев назад

    Excellent video and now gives me some numbers to use in a rebuttal to a copper only man

    • @ultimatehandyman
      @ultimatehandyman  9 месяцев назад

      I’m glad you found the video useful
      Thanks for the comment 👍

  • @vidushigupta2114
    @vidushigupta2114 3 года назад

    sir , where can i buy this product , can you please share the link incase this is sold online

  • @stevenking2980
    @stevenking2980 9 лет назад

    It's all up to the durability of the stainless steel compression ring and the o ring. I never use these. I do use the shark bite brass ones, but never in a ceiling or wall.

    • @stevenking2980
      @stevenking2980 9 лет назад

      THANKS FOR PUTTING "psi" on there as well! I didn't have to look it up! Good video.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Steven King
      You are welcome
      Thanks for the comment ;-)

  • @petersaville2265
    @petersaville2265 3 года назад

    Pressure testing is a dangerous activity. You are correct about water being less dangerous than air. You never use air unless totally unavoidable. In the video you would have had air in the end of the compression fitting, this should have been vented out. You also need to provide more safety restrictions when doing the pressure test with water you was holding a lethal weapon in your hand whilst pumping up the pressure. Just a few tips from Pressure Vessel Engineering.

  • @Safc0191
    @Safc0191 6 месяцев назад

    When do you need 10 bar in a system

  • @ermingtonplumbing442
    @ermingtonplumbing442 6 лет назад

    New, push fits are fine.
    But the rubber O rings hat seal them will always fail over time.
    Slight movement from expansion and contraction, pressure fluctuations, water hammer, etc etc cause the O rings to fail given enough time.
    Any side deflection in particular, compressed the o ring on one side.
    I never use them in walls.
    But do use the push to MI thread adaptors with a cistern cock under sinks and basins, when replacing old soldered in tapware, with copper pipe coming in through the wall.

  • @kristiaand
    @kristiaand 9 лет назад

    i've always been curious about the pressure these fitting could handle and this is a good clear test, i have to say i would trust these over metal compression fits any time. the amount of times i've had metal fittings leak is no-bodys business. never had a plastic pushfit leak tho.!

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +kristiaand Do you normally use copper or brass olives with the compression fittings?Thanks for the comment

  • @cvarsani2190
    @cvarsani2190 Год назад

    Can you do a solder vs press fit video using a water pressure pump please?

  • @colabottlethief
    @colabottlethief Год назад

    Could you do a pressure test on a push fit fitting using the push fit plastic pipe? Just to see which gives up first, the pipe or the fitting. Great videos 👍

    • @ultimatehandyman
      @ultimatehandyman  Год назад +1

      I tried that once; I did the exact same test using plastic pipes with no pipe inserts. The reasoning behind the video, was to show how important pipe inserts are in plastic pipe. I went right up to 50 Bar and the stop end would not blow off from the pipe. I wanted to make that video, as the plumbers at my sister’s house have done all the plumbing in plastic pipe and have not used a single pipe insert!
      Obviously when I do any plumbing jobs there, I always put pipe inserts in 👍

  • @kissingfrogs
    @kissingfrogs 5 лет назад +3

    Great Vid. Out of curiosity what is typical domestic water supply pressure?

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +4

      There is no "typical water pressure" in the UK, It can vary greatly depending on where you live. At my house the pressure is considered to be high, at about 8 BAR (116PSI)
      Thanks for the comment

    • @toysareforboys1
      @toysareforboys1 5 лет назад

      My city water pressure (Whitby, Ontario, Canada) is also considered very high (8 BAR, 115PSI), the city considers 72PSI (5 BAR) to 102PSI (7 bar) to be "high". I was denied a warranty claim on a faucet set because of the high pressure. The city gave me a free device to put on our water meter to limit the pressure to 58PSI (4 BAR) but I didn't like it. With the device installed the pressure from our shower heads went way down and took much longer to shower (but probably used much less water in the long run), so we removed it to go back to 115PSI. Standing under the shower head feels like you're standing in front of a fire hydrant fully open :)

    • @Klokopf52
      @Klokopf52 5 лет назад

      According to my local (Germany) Water Company the expected water pressure is between 3 and 6 bar depending on your height relative to the water level inside the tanks. In my case i only get 3 bars during nighttime if the levels start to rise, during the day im at around 2,8-2,5, which is pretty low compared to the rest of Germany.

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +1

      I'm thinking of installing a pressure reducing valve here, as the main stop tap to the house is only open about 1/8 of a turn. If I open it more than that, we get really bad water hammer. In the past couple of years we have also had a few sealing washers fail- meaning damaged ceilings etc. A pressure reducing valve is supposed to reduce the pressure, but not the flow! I'm not sure how effective they are yet!
      Thanks for the comment 👍

    • @toysareforboys1
      @toysareforboys1 5 лет назад

      @@ultimatehandyman Let us know how it goes!! We also used to get really bad water hammer and when I posted about it on a forum there were lots of suggestions that said to install a small expansion tank upside down with a check valve on the incoming side on any cold line in our house! So we found a good spot under our tankless water heater and it worked FLAWLESS! ZERO water hammer even if you SLAM the taps closed from full flow!! oi64.tinypic.com/1zpk7l5.jpg

  • @momochouiheb6918
    @momochouiheb6918 9 лет назад

    Great test ....don't forget to wear your safety glasses . ...thanks for sharing .

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Momo Chouiheb
      Absolutely!
      Thanks for the comment ;-)

  • @DaveTaste
    @DaveTaste 6 лет назад

    FYI a Hosereel jet on a fire engine runs at between 30 and 35 bar. So this is easily good enough for any house.

  • @keithg1xfl
    @keithg1xfl 2 года назад

    I dont know how you would do it, but the thing that needs testing isn't the Pressure (We all Agree they are more than Capable of standing Normal Water Pressure +) but the Longevity of the Internal Seals, How Do They stand up to The Progress of Time ?

    • @ultimatehandyman
      @ultimatehandyman  2 года назад

      I've never known one to leak- yet!
      Thanks for the comment 👍

  • @sc4rf4ce1983
    @sc4rf4ce1983 4 года назад

    How does it fare against sustained and variable high pressures?

    • @ultimatehandyman
      @ultimatehandyman  4 года назад +1

      Not sure, I only made this video to prove that they actually do work, as some people did not trust them.
      Thanks for the comment 👍

    • @sc4rf4ce1983
      @sc4rf4ce1983 4 года назад

      @@ultimatehandyman thanks for the reply. I'll be replacing my ground floor copper piping with pex in the summer. Was originally going to use compression fittings, but I'll possibly switch to push fit now instead given the ease of use.
      I'm just concerned about longevity.

  • @Wonkabar007
    @Wonkabar007 4 года назад +11

    So a submarine would have to dive to 1633ft to reach that failure point, thats impressive 👍

  • @blackmore56
    @blackmore56 9 лет назад +1

    Great work my friend. Must say though, I nearly sh_t myself when that top blew off. Keep up the great work.
    Spud.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +blackmore56 When I was pressurising the pipe I knew it was going to blow off as the fitting slid further up the pipe, which relieved some of the pressure. It didn't half go with a pop though ;-)Thanks for the comment

  • @mrbaza8793
    @mrbaza8793 3 года назад

    Ur videos 📹 r always brilliant... but I STILL don't trust them 🤣 gotta be compression 🔧
    Great video top man 🧰👍🏾
    Thanks 😊

    • @ultimatehandyman
      @ultimatehandyman  3 года назад

      Push-fit fittings have saved my life, so many times, especially when the bath connector started leaking-
      ruclips.net/video/eqECFK42PKQ/видео.html
      Thanks for the comment 👍

    • @mrbaza8793
      @mrbaza8793 3 года назад

      @@ultimatehandyman yeah I’ve watched that video that’s why I got our stores 🏬 manager to order loads of 1/2 & 3/4 tap connectors 😄 ~ being honest they r well handy in those situations 😁 please keep up the fantastic work mate 👍🏾 your work is highly respected.
      Thank you 😃

  • @byrocph4834
    @byrocph4834 4 года назад

    Thank you for this experience
    Please I have a question, in the factory what is the usual test for this piece
    Thanks.

    • @ultimatehandyman
      @ultimatehandyman  4 года назад +1

      I'm not sure how they test them in the factory.
      Thanks for the comment 👍

  • @BrianOlmsted
    @BrianOlmsted 6 лет назад

    Would like to see you do the test with the brass push fit fittings from Sharkbite and the like rather than brass with copper and PEX and see how they perform as i imagine they would get higher than 40-50 bar. Interesting video none the less that to me debunks the people in forums saying they leak or will come off. I would say people are not following the manufacturer instructions to prevent the O-Rings from getting damaged from not deburring and/or not putting the pipe in the full depth.

    • @ultimatehandyman
      @ultimatehandyman  6 лет назад

      I'm afraid my pressure test rig only goes up to 50 BAR.
      Thanks for the comment

    • @BrianOlmsted
      @BrianOlmsted 6 лет назад

      Well it be interesting to see if the brass fittings would get up to the full 50 bar or not since the plastic one failed just before 50 bar but I guess it is really irrelevant in a domestic application. I wonder how a copper cap would compare and if it could go much higher if you had a machine that could push it further.
      Considering that 50 bar is equivalent to being down 500 meters (1631 feet) below sea level this is pretty impressive as a recreational scuba diver can only go down about 40 meters (130 feet) and professional scuba diver can go about 60 meters (200 feet) before they feel their insides crush LOL.
      I definitely feel more confident putting these into my house if they are installed correctly (making sure you debur the ends to prevent o-ring damage and slipping it onto the joint to the manufacturer specs using marking lines if necessary). I'm sure the brass fitting would outperform the plastic ones that you demo'd at nearly 50 bar. Also considering the insurance companies and build code doesn't have an issue with them being installed in walls, etc ... but I guess nothing beats a clamp on or solder joint.

    • @ultimatehandyman
      @ultimatehandyman  6 лет назад

      I'm sure brass fittings would be far superior to plastic ones.
      For underground water in the UK we use MDPE pipe and you can use compression fittings or push fit fittings on it providing you use a pipe insert, but there is a firm that makes brass push fit fittings (Melimatic) and they can be pushed straight onto the pipe without a pipe insert.
      Good luck with the Scuba diving (rather you than me)
      Thanks for the comments

  • @nasir_glasgow5274
    @nasir_glasgow5274 8 лет назад +1

    hi, great video ,whats make of that push fit haven't seen them before
    thanks

  • @mrmtellstherealtruth5304
    @mrmtellstherealtruth5304 6 лет назад

    I like your videos - clear and helpful. Good job mate.

  • @jameslocke3406
    @jameslocke3406 5 лет назад

    What is the brand name of the end cap you used please? I can’t find any on the internet with a screw top! Thanks in advance! Great Demo!

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      I'm not sure, sorry. I think I picked it up from B&Q, if that helps!
      Thanks for the comment 👍

    • @thebaldconvict
      @thebaldconvict 3 года назад

      @@ultimatehandyman Flomaster?

    • @ultimatehandyman
      @ultimatehandyman  3 года назад

      @@thebaldconvict It could be

  • @nissimtrabelsy1944
    @nissimtrabelsy1944 9 лет назад

    Can you please make a video explaining how to expand a faucet hole [granitt/porcelain]?

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Nissim Trabelsy It's not something I intend doing in future, sorry.If you get the correct diamond core bit you should be able to enlarge it using a similar technique to this-ruclips.net/video/jurSZR1Se6A/видео.html

  • @ramraja7796
    @ramraja7796 5 лет назад

    50 bars is great but that was push fitting on a copper tubing would it be same on poly pipe??

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      I think it would pop off the end of the pipe, as the stainless steel grip rings in the fitting will only be gripping the plastic.
      Thanks for the comment 👍

    • @jordanholt7149
      @jordanholt7149 5 лет назад +1

      More likely the PEX/PB wall would rupture before the fitting blew off, around 20-25bar depending on temp in my experience.

  • @chippywarren9706
    @chippywarren9706 6 лет назад

    I may need to change things where I live. My bathroom is tilting owing to heavy rains in the moutains. Question: what kind of temps can these fittings take please? I'm using a wood fire with what's called a water jacket. Basically the fuel heats the water surrounding the fire, water is the pumped to tanks and radiators. I'm concerned the pressure on pipes bending through shifting masonary will split them. Any help please? Thank you.

    • @ultimatehandyman
      @ultimatehandyman  6 лет назад

      It depends what make you get, the John Guest Speedfit fittings can be used on hot water up to 114 degrees C intermittently for short periods of time- www.johnguest.com/speedfit/common-plumbing-and-heating-questions-answered/
      Thanks for the comment ;-)

    • @chippywarren9706
      @chippywarren9706 6 лет назад

      @@ultimatehandyman Thank you. I'm not certain this will work for me then given the fuel I'm using, fluctuating heat levels. Many thanks again.

  • @hawkercnc8261
    @hawkercnc8261 8 лет назад

    The early versions of these fittings had the stainless fingers inside the 'o' ring and hence in water. The dissimilar metals set up electrolytic corrosion and the hot water failed first after 18 months and the cold after 2 years in a system where plastic fittings had been joined to copper. The metal was rotted away where the two metals touched. These new ones have overcome this problem by moving the 'O' ring inboard. However if they were to be used in a wet external environment such as a farm yard this could happen with the use of copper pipe at one side. It should not be a problem with plastic to plastic. 'O' rings will rot in a few days if left in WD40 so careful with lubricants and oils. I would expect ''O' ring failures after 20 years. Pressure testing would be interesting in a simulated air pressure ring as is used in many workshops. 15mm copper is often used. The fittings are clearly up to it. Many thanks for the work.

  • @HonestTechReviews
    @HonestTechReviews 3 года назад

    Great video. Would you be able to do a comparison test with Hep20, speed fit etc? It would be very interesting so see how each stands out

    • @ultimatehandyman
      @ultimatehandyman  3 года назад +1

      I don't think there would be a lot of difference to be honest, as I would imagine they would all be able to cope with the pressure from my test rig. A lot of people have personal preferences with push fit, I prefer Speedfit, but some people only use Hep2O. I'm not sure if that is due to the cost though.
      Thanks for the comment 👍

    • @HonestTechReviews
      @HonestTechReviews 3 года назад

      @@ultimatehandyman Amazing, thanks for the quick reply! That’s true i personally use Hep20. But they all work the same as you said. 👍 good videos by the way !

  • @lightwavelibrary
    @lightwavelibrary 5 лет назад +2

    that is wholly impressive. 725 PSI? amazing!

  • @josht8288
    @josht8288 6 лет назад

    If it's easily accessible I use plastics and if it's buried under floors or in Walls always copper with end feed fittings.

  • @Saint_Nicolo
    @Saint_Nicolo 9 лет назад +2

    Wanna impress me, show me how to stop the fitting from leaking after its 5 years old and you accidentally bump the darn thing.

    • @Meneerjen
      @Meneerjen 8 лет назад

      +audimaximus Usually leaking is a result of a damaged O-ring. Remove the cap from the fitting, replace O-ring, put the cap back and you should be fine =)

    • @Saint_Nicolo
      @Saint_Nicolo 8 лет назад +1

      Yeah, I figured out how to pop that sleeve and replace the o ring. Good thing to learn since I have a high school full of these dried up brittle push fittings that start leaking by merely looking at them.

  • @pakpukik
    @pakpukik 9 лет назад

    Question please...
    how do you adjust the pressure fitting to the actual pipe? Do they come in various diameters? Do you have to do something on the copper pipe in order for the pressure fitting to fit well?
    Thank-you.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +pakpukik They come in various sizes. In the UK the two commonest sizes are 15mm and 22mm, so you just buy the correct push fit fitting for the pipe you are using. When you cut the pipe it is critical that there are no burrs on the pipe as they could damage the sealing O rings in the fitting. I normally use a de-burring tool before using a push fit fitting.Thanks for the comment ;-)

    • @pakpukik
      @pakpukik 9 лет назад

      +Ultimate Handyman Very well thanks.
      What tool would you uae for deburring the metal? Something like Noga tools?

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +pakpukik I use a specific pipe deburring tool, like in this video- ruclips.net/video/bajPbO9AwfE/видео.html

  • @MrPantss
    @MrPantss Год назад

    What is the average uk domestic plumbing pressure? Interesting vid.

    • @ultimatehandyman
      @ultimatehandyman  Год назад

      Not sure, but in this house it’s about 8 Bar. I need to fit a reducer at some point to get it down to about 3 Bar 👍

  • @Crazyoldman84
    @Crazyoldman84 6 лет назад

    I'm goings to DIY my wet room and I'm planning on using plastic pipes because I'm not a plumber. I'm going to be hiding the pipes behind the walls and will have no access to them when finished. I'd appreciate any tips or thoughts before I go ahead with this?

    • @ultimatehandyman
      @ultimatehandyman  6 лет назад +1

      I've never done a wet room, plastic pipe is great and has many advantages over copper pipe, especially as you can bend it without any specialist equipment. I made a video a few weeks back on how to use it- ruclips.net/video/Z83vlwUyZIw/видео.html
      As long as you cut it correctly and use the correct inserts it will be fine.

    • @Crazyoldman84
      @Crazyoldman84 6 лет назад +1

      Ultimate Handyman Thanks I guess I'll just have to give it a go👍🏼

  • @trouinmassonri630
    @trouinmassonri630 4 года назад

    Hello.On which site should I order these?Please tell me.

    • @ultimatehandyman
      @ultimatehandyman  4 года назад

      In the UK, you can get them from Screwfix or Toolstation or JTM plumbing etc.
      Thanks for the comment 👍

  • @68000Mark
    @68000Mark 9 лет назад

    Great video, I am old school and prefer soldered copper fitting, I will use compression if soldering is not possible. Can you do a test on a John Guest fitting as they are very common. Lastly it looked like the blank end thread let go rather than the grip ring.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Mark Davies Thanks Mark, I'll try out some popular brands soon such as Speedfit and Hep20.I'm not sure of the brand of this fitting as it was one I picked up from the plumbers merchants, but it seemed to go back together again after the end had blown off!Thanks for the comment ;-)

    • @Blaggsta
      @Blaggsta 9 лет назад

      +Ultimate Handyman I used the speedfit... I thought that was in the clip... would love to see that tested

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +Adam B I'll try some out in the next few weeks ;-)

  • @brandywell44
    @brandywell44 9 лет назад

    Impressive, but what is the service life of these? All plastics absorb water over time and become brittle with age from water and heat.

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад

      +brandywell44 I'm not sure how long these fittings will last, although plenty of people use these on new installs!I have had problems in the past with plastic water inlet valves- where the threaded plastic has softened and then caused a leak. Once this happens you have to replace the whole unit, which is very annoying!Thanks for the comment ;-)

  • @zuluula
    @zuluula 5 лет назад

    Would you recommend JG speedfit to do a bathroom and the kitchen ? Or would you rather use pre soldier copper pipes and fittings ? First time DIY er
    Thank you

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Yes, it will be fine.
      I made a video about push fit here- ruclips.net/video/Z83vlwUyZIw/видео.html
      Thanks for the comment

  • @youngjock1985
    @youngjock1985 7 лет назад

    How long should it take to test a system after a complete repiping of a property? I have a 3 bedroom property. Is it something that should be tested over a number of days?

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      Normally it would be pressurised and then watched for a couple of hours, if the pressure does not drop over that period it's likely to be watertight.

  • @TheWhisky81
    @TheWhisky81 Год назад

    Great video mate, am surprised the pipe didn't give way either, is that just standard 1mm thick plumbing pipe your using there? Thanks john.

  • @steves1460
    @steves1460 4 года назад

    Reminded me of my days as a waiter, delivering a bottle of champagne to newly-weds in their room. Suffice to say, the bloody thing exploded and the cork went around the small room like something out of a pinball machine; we all ducked for cover! The champagne then decided to follow the cork and so i rushed to get it into the glass...too fast. This then bubbled-over and was druipping off all four corners of the table. The couple thought it was hilarious, but then again they hadn’t yet seen how much that bottle had cost!
    Thinking back, i reckon one of my colleagues had shaken that accursed bottle! To be topical, reckon it was 20-bar and being s man’s man, i wasn’t a wuss wearing safety glasses! ;-)

  • @MagicInternetMonkey
    @MagicInternetMonkey 7 лет назад

    Hey do you have a video like this made with the shark bite brand.

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      No, sorry.
      I have not seen that brand for sale much in the UK but will get some if I see any ;-)

  • @a.r1761
    @a.r1761 2 года назад

    What is the pressure in domestic water pipe?

    • @ultimatehandyman
      @ultimatehandyman  2 года назад

      It varies depending on where you live. I tested the property here once and it was 8 Bar, which is considered very high water pressure!

  • @geoffreycasey875
    @geoffreycasey875 5 лет назад

    Great video as always. Thanks. 🍀🇮🇪👍

  • @kedarpawar9758
    @kedarpawar9758 4 года назад

    Great work
    I request to provide sizes of push fit pdf

  • @TechWithYouVee
    @TechWithYouVee 4 года назад

    Can you leave it at a constant 40 over a few weeks and see what happens?

    • @ultimatehandyman
      @ultimatehandyman  4 года назад

      No, normally when you pressure test a pipe/fitting you only do it for a specified amount of time. For steam pipes on site it is only about 30 minutes. If you leave the pressure in the system for longer than that, it will probably cause damage to the testing rig etc.
      Thanks for the comment 👍

  • @yensabi
    @yensabi 9 лет назад +1

    Nice demo chez , there are a few comments on how long this plastic pipe / fittings will last , most manufacturers give a 25 year guarantee , whether it will last longer nobody knows yet as its not been around for that amount of time , i use it quite a lot and have no worry s about it as long as it's a good brand like Hep or PP...... Cheers : )

    • @ultimatehandyman
      @ultimatehandyman  9 лет назад +1

      +yensabi Thanks, I'm of the opinion that if I was working on a house which I was going to sell on I would use plastic, but if I intended to keep it I would use copper and solder ring or compression fittings.Thanks for the comment ;-)

  • @rizzorat1987
    @rizzorat1987 8 лет назад

    Hi mate, great video! A plumber has installed this on the outbound copper pipe of a mixer shower that was running when turned off. (he removed the shower head and capped it off) this will be like this for about a week whilst he is on other jobs and will then return and fit the shower, is there any danger of the pipe bursting or pressure building up elsewhere? cold water tank and hot water thing in airing cupboard.

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад +1

      It should be fine. I also use these as a temporary cap when doing such jobs ;-)

  • @neiljones2264
    @neiljones2264 5 лет назад

    Blimey that was tense. Very reassuring though, has given me the confidence to use on a future project. Great video as always. Thanks.

  • @tigingrasta953
    @tigingrasta953 5 лет назад

    Hi can you use push fitting on central heating?👍

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Yes, no problem at all.
      Thanks for the comment 👍

  • @geoffreycasey875
    @geoffreycasey875 5 лет назад

    Which fitting would you trust in your house? 🤔🍀👍

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +1

      I'd probably use solder ring fittings, but if the pipe was plastic I would use John Guest speedfit.
      Thanks for the comment 👍

  • @GeeTheBuilder
    @GeeTheBuilder 5 лет назад +4

    Maybe you’ve already done this in another video but I’d bet a JG Speedfit 15mm end stop would easily take 50 bar
    The one you tested it looks to me like the plastic interval thread failed. As you will know, with JG end caps it’s one moulded bit of plastic (apart from the release bit of plastic)
    Interesting vid 👍

  • @JayKay-ht8rg
    @JayKay-ht8rg 5 лет назад

    Great video! Again. Thanks! 👍🏼👌🏼

  • @liljasere
    @liljasere 8 лет назад +1

    What people praising pushfit/plastic always look past is 15years down the line when its time to make changes and work on the stuff its purely a short term gain that's why so many people in the renovation game love it and also anyone an use it

  • @maxlogun1052
    @maxlogun1052 7 лет назад

    As other folks have mentioned how will these plastic fittings with a rubber seal age ????
    I know a lot of boilers all now have very similar variants on the same thing buried away inside them but most new boilers are not likely to last 20 or 30 years so there life span is not going to be an issue. I don't personally think these fittings are going to last 50 plus years as correctly fitting compression and end feed joints we do, will be interesting to see, guess time will tell. Nice video though thanks for putting it out there mate.

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      I think you are correct, if I was installing pipe in my own house I would use copper pipe and solder fittings or compression.
      Thanks for the comment

    • @andygozzo72
      @andygozzo72 5 лет назад

      @@ultimatehandyman our house has a cold water feed from a plastic 'alcathene' pipe thats over 45 years since it was fitted and so far (fingers and other bits crossed) still intact.... stopcock really needs changing, so things might get interesting...

    • @andygozzo72
      @andygozzo72 5 лет назад

      most main pipework is copper, but a few bits of speedfit fittings and pipe in the porch extension, they're about 15 years old now... still good, although some fittings are earlier type than others, without the 'twist lock', and have discoloured....

  • @basilkearsley2657
    @basilkearsley2657 5 лет назад

    Great video. Do you have one for poly pipe too?

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Thanks, No I have not tested poly pipe, but it should easily stand high pressure.
      Thanks for the comment 👍

  • @izaaksmifsud3755
    @izaaksmifsud3755 3 года назад

    What brand is that push fit fitting ?

    • @ultimatehandyman
      @ultimatehandyman  3 года назад +1

      It was just a cheap unbranded one that I bought from B&Q (not sure which make it is)
      Thanks for the comment 👍

  • @marcs5960
    @marcs5960 6 лет назад

    fitted push fit once, never again used in outside toilet and snapped in the winter. for me would rather use compression or solder, but there's a new design on the market Xpress :)

  • @BazColne
    @BazColne 7 лет назад

    Thank you for a valuable contribution.

  • @paulperrin2152
    @paulperrin2152 2 года назад

    What bar is household pressure??

    • @ultimatehandyman
      @ultimatehandyman  2 года назад +1

      It can vary, depending on where you live.
      At this house, the pressure is over 7 BAR (nearly 100Psi)

  • @davidyoung9561
    @davidyoung9561 5 лет назад

    I have done loads of plumbing in my home and never used 'push-fit'. I always insist on using solder joints.

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      Solder fittings are my favourite, but many people like push fit.
      Thanks for the comment 👍

  • @caileanmoore2835
    @caileanmoore2835 7 лет назад +3

    As a plumber, I found this test very interesting. I have absolutely no hesitation in using good quality push fit sytems and I've been in the industry for 40 years. What gives pushfit it's bad name/failures are unskilled users who don't follow the manufacturer's instructions. However, I much prefer using copper pipe with push fit fittings than plastic pipe and it would be really great to see you doing the same pressure test on plastic pipe instead of copper. I doubt very much if the fittings would still grip plastic pipe at 50 bar.

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад +1

      You are right, but some of the failures are due to the lack of proper instructions with the push fit fittings. Years ago I picked some up from a large D.I.Y outlet and the instructions on the packet were minimal, there was no mention of not using them on chrome pipe for example!
      I'll try pressure testing a push fit fitting on plastic pipe when I get time ;-)
      Thanks for the comment

    • @caileanmoore2835
      @caileanmoore2835 7 лет назад +1

      The other big no no is using modern metric push fits on imperial copper pipe. Speedfit and Hep20 make metric to imperial adaptors, but anyone attempting a bit of diy is going to be oblivious to this. Same goes with not using inserts or even just the correct inserts for each individual brand of pipe. They are not interchangeable as there are different tolerances in the diameter of each brand of pipe. Again, no one will explain that in a diy store. Keep up the good work. Videos are top dollar.

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад +1

      @@tomhedger7013 A few weeks back I replaced a kitchen tap for my sister. To my horror I discovered that her house has been piped up in plastic pipes- with no pipe inserts!
      So I tested one of the fittings with some plastic pipe with no inserts, and it took 50 BAR (maximum pressure of my test bucket) and I left it for a good hour or so, before I had to put the stuff away and do something else ;-)
      Of course hot water/ heating cooling might be a completely different outcome.
      Thanks for the comment

    • @ultimatehandyman
      @ultimatehandyman  5 лет назад

      @@tomhedger7013 I'm sure there are instances where they will blow off! It's always best to use the correct inserts and fitting for the pipe that you are using- just in case ;-)
      Thanks for the comments

  • @pkumar5411
    @pkumar5411 4 года назад

    Great video, but few legacy folks still use copper systems which requires a plumber call out just for simple things, the modern technology allows plumbers to spend less time onsite and get the job done without heat (soldering) etc, and still ensure the same charge to the customer, it really helps save time (which is money) to keep customers happy and I am sure they are happy to pay same fees to plumbers. Copper should be almost eradicated from household plumbing and replaced with modern flexi plastic systems.

    • @ultimatehandyman
      @ultimatehandyman  4 года назад

      There are advantages and disadvantages to both systems.
      Thanks for the comment 👍

  • @dyannedabest2073
    @dyannedabest2073 7 лет назад

    How much of the push fitting is off the end of the pipe

    • @ultimatehandyman
      @ultimatehandyman  7 лет назад

      It has to be inserted as far as it will go, but slowly moved to the end of the pipe with the pressure.

  • @eddyjawed4871
    @eddyjawed4871 4 года назад

    Awesome video thanks so much. really helps total amateurs like me

  • @keithg1xfl
    @keithg1xfl 2 года назад

    I've just Confirmed with JG Speedfit and the O Rings are made from EPDM, which I googled the Lifespan Of and It came back as Unlimited, which I thought was interesting

  • @cdn5535
    @cdn5535 3 месяца назад

    This video is 8 years old and so are the comments. Even now in 2024 push fit fittings aren’t old enough for anyone to tangibly say that they don’t hold the test of time. But JG Speedfit and Hep2O are both rated for 50 years - instead people have formed opinions on them because they don’t trust anything other than traditional methods. If they are fitted correctly they won’t fail, the same as copper if it’s prepared and soldered correctly. I swear by them - I’m not a plumber, but let’s say an ‘advanced DIY’er’ who knows what he’s doing and has a lot of renovation experience who does things within regulations - anything new installed that is hidden is done in plastic and push fit, anything visible is done in end feed copper - I’ve had zero issues with either. Let’s be honest CH is 1.5-2 bar, a good mains water is 2-4 bar - this just went to 50 bar, and these fittings have advanced since this video. Accept the change and trust these lol

  • @martkt10
    @martkt10 8 лет назад

    What is the normal water pressure in the uk

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад +1

      +martkt10 I don't think there is a regular water pressure.Where I live we have 7 Bar (approx. 100Psi ) which is considered high- ruclips.net/video/LD_xm6zUkkU/видео.html

    • @martkt10
      @martkt10 8 лет назад

      +Ultimate Handyman Thank you

    • @ultimatehandyman
      @ultimatehandyman  8 лет назад

      +martkt10
      You are welcome.
      Thanks for the comments ;-)