Hey tads i’ve had me a lot during service work. You’ve helped me a lot doing service were very intelligent very smart and we will get service. I hope you’re having a great day man my name is RICHARD by the way up in Asheboro North Carolina.
Tad, what dual fuel thermostat do you recommend? My contractor installed a Sensi Smart (model 1F87U-42WF). That thermostat has no lockout based on outside temperature, so the heat pump always runs when heat is called for. I am thinking of a Sensi Touch 2 or Ecobee smart. These two thermostats use the outside temperature from the WIFI rather than a temperature sensor.
I don’t have the option of 40 for my balance . It starts at 45 any lower and it’s off ? For number 356 Your videos are superior with knowledge. Merry Christmas 🎄
Trying to hook up two themo, up and down, Now I have both hooked up to W2 and Y but , it keeps going out when I cut heat on. Didnt take picture of upstairs when I changed it out and thinking they need to be hooked up a little different any suggestions.
I have the Goodman dual fuel unit. Heat pump and two stage gas burner. Selecting 255 heat pump will only let me select one auxiliary home 221 and not 2 stage heating? Two stage heating is only allowed for conventional systems. This is TH6320WF2003 thermostat. Thanks for your videos and help, they’re great.
Trane due fuel furnace with American Standard Heatpump. T6. Wired like I always do. Heatpump stayed in circuit when I asked for higher demand. ODT was mid 40s. All should be good?
@@harrygilbert4593 I just put an ICP heat pump on an existing Trane Propane furnace with a Trane thermostat. Found out on the first cold day it won’t cycle to aux mode. Connected the white wire on the stat and now it won’t shut down the OD unit while in aux mode. Which brings me to this vid. Looking at a T6 to replace the Trane stat. But will it shut down the OD unit by removing power from the Y terminal in AUX mode?
If you drive the temp up on the Tstat with Dual Fuel . Is it supposed to lock out the heat pump and go straight to gas? Working with a T-9 TH6220WF2006. I appreciate your content.
355 compressor lockout / balance point is the temperature set point at which if outdoor air is below that set point the compressor is locked out and only backup gas heat can be used. 356 outdoor lockout backup heat is the temperature set point at which if outdoor air is above that set point the backup heat is locked out and only HP heat can be used.
that's a very loose use of the term "Heat Pump balance point" Heat Pump Balance point is when the heat pump capacity equals the heat loss of the structure. Calculated using AHRI performance data and Manual J form.
Hey tads i’ve had me a lot during service work. You’ve helped me a lot doing service were very intelligent very smart and we will get service. I hope you’re having a great day man my name is RICHARD by the way up in Asheboro North Carolina.
I'm about to sign a contract for 3 dual fuel systems. This was really helpful.
Congratulations bro
Please share the video when you can
Nice explanation from texas
So what keeps the heat pump and fuel from running together? If you turn that stat up more than 4 degrees it brings on the Aux heat also?
Good content on setting up thermostat for heat pump application. I’m going to recommend a new apprentice to your channel.
Thank you
So glad to hear
Thank you for sharing My content
Tad, what dual fuel thermostat do you recommend? My contractor installed a Sensi Smart (model 1F87U-42WF). That thermostat has no lockout based on outside temperature, so the heat pump always runs when heat is called for. I am thinking of a Sensi Touch 2 or Ecobee smart. These two thermostats use the outside temperature from the WIFI rather than a temperature sensor.
Great Job - Upper Marlboro MD
What should be the heat pump lock out for best efficiency if your from Canada.
I don’t have the option of 40 for my balance . It starts at 45 any lower and it’s off ? For number 356
Your videos are superior with knowledge. Merry Christmas 🎄
Trying to hook up two themo, up and down, Now I have both hooked up to W2 and Y but , it keeps going out when I cut heat on. Didnt take picture of upstairs when I changed it out and thinking they need to be hooked up a little different any suggestions.
control board or thermostat can both control backup heat.
This helped clarify most questions. So if I were to use an 8000 could I use the honeywell wireless outdoor sensor via wifi?
WHAT IS THE BEST EFFECTIVE TEMPERATURE TO RUN MY HEAT PUMP FOR HEAT? i HAVE ALWAYS HEARD 32 IS THAT SO?
I have the Goodman dual fuel unit. Heat pump and two stage gas burner. Selecting 255 heat pump will only let me select one auxiliary home 221 and not 2 stage heating? Two stage heating is only allowed for conventional systems. This is TH6320WF2003 thermostat. Thanks for your videos and help, they’re great.
Glad you like the video
What is difference between outdoor lockout/backup heat and the compressor lockout/balance point setting?
Same thing
My man Tad 🙌🫡
Is there a way to set the thermostat so if the customer wants to use heat pump or gas furnace without the 40° of setpoint?
yes don't use a wireless outdoor thermostat
Trane due fuel furnace with American Standard Heatpump. T6. Wired like I always do. Heatpump stayed in circuit when I asked for higher demand. ODT was mid 40s. All should be good?
@@harrygilbert4593 I just put an ICP heat pump on an existing Trane Propane furnace with a Trane thermostat. Found out on the first cold day it won’t cycle to aux mode. Connected the white wire on the stat and now it won’t shut down the OD unit while in aux mode. Which brings me to this vid. Looking at a T6 to replace the Trane stat. But will it shut down the OD unit by removing power from the Y terminal in AUX mode?
Can't find that dual fuel thermostat with that model # TH6320U2008
Why is the balance point lower than the lock out.
Hello, I need your help in setting up honeywell thermostat thx9421r for dual fuel setup, if you could upload any video that will be awesome.
What happens when the outdoor unit goes into defrost. And how to wire that.
W2 engages like it would for heat strips and bring furnace on
Will outdoor temp be shown on the thermostat when the sensor is installed, regardless of duel fuel or conventional setup? Thank you
Yes it will be shown.
If you drive the temp up on the Tstat with Dual Fuel . Is it supposed to lock out the heat pump and go straight to gas? Working with a T-9 TH6220WF2006. I appreciate your content.
No answer ??hello ?
Great video like always thanks you for sharing great information 🙏🏻
My pleasure!
355 compressor lockout / balance point is the temperature set point at which if outdoor air is below that set point the compressor is locked out and only backup gas heat can be used. 356 outdoor lockout backup heat is the temperature set point at which if outdoor air is above that set point the backup heat is locked out and only HP heat can be used.
that's a very loose use of the term "Heat Pump balance point" Heat Pump Balance point is when the heat pump capacity equals the heat loss of the structure. Calculated using AHRI performance data and Manual J form.
I never understood the 355 and 356 function fully lol
Awesome
Call me old-fashioned but I'm Just a Bill Porter kind of guy
Not a fan of those t stats
me neither