Aam aadmi ke 3 bhk ke ghar me jaha 1 ac ya ek geyser, Iron, mixer grinder, room heater or Pani ka ek moter chalta hai waha Maine board se room ke boards me maximum 4 mm wire sufficient hota hai....AC or geyser dono ek saath to chalna nahi hai ....room heater bhi winter me hi chalega...1 mm for fan, tv, bulbs ke liye sahi hai jo room ke boards switch se point ko jayega.... Service wire ke liye 10mm ka aluminium wire use kare wo copper se sasta parega....
Hello paji ma punjab sa electrision jasa koi valding sat wali machine ha vo chalti ha double phase jab ham uski single wire par amp batati ha 25 amp ab ma es bat ka pata nahi chal raha ki 25 amp ki ha ya 50 amp ki jas koi ac hota vo late 7 sa 8 amp par vo chlta single phase par us pr lagate ha 2.50 mm ki wire ab ya janna chahata hi jo double pase wai machine ha jo 25 amp ki us par kitne mm ki wire lagau
Ha sir mare gharpe vayaring to nhi hay abhi par muje taatkal main vayar karna ahy to garpe to main apse pucha na cahta tha ke 1.00mm ka anchor ka varar us kar sakata ho muje 9 volteg ke balaf aur aur fen 3 hay to aur ek pani ki motar hay adhe ki to sir uas kar sakte hay batana to sahi rehmga sir kiya thenkue
Sir thank you very much,,, sir thank you very much,,, please put about more about electrical thank you very much I am from bangalore city,,, I will give you 5 stars
Sir ye 5 se multiply aapne kese Kiya ye samajh mai ni aaya, digit 5 hi kyu li aapne multiply ke liye, aur digit kyu ni li,koi formula hai kya iska sir,ye please bata dijiye
Ye sab +2 second year physics me formula hota hai jab hamne Ohms law padhate Hain tab conductance hi wire ki conductivity aur length aur CSA se kaise relate hote hain ham batate hain.jab wiring karogi copper se to conductivity to same aur length bhi same rahega to CSA se kitna current flow hoga ye sab value put karne ki baad me ata hai.yahan ye 5 constant nehin hai.jsise ki 4 sq mm copper wire me 24 se 27A tak aur 6 sq mm copper se 31 se 37 A tak current hi flow hoga
Multiply by 5 ka formula Kahan se laye? Mere paas geyser hai 3000 w ka uske sath Bajaj company ne 1.5 sqmm ka wire dhiya hai aur woh 6 saal se chal Raha hai . Voltas ka 1.2 ton 1200 w ka ac hai uske saath bhi 1.5 sqmm ka hi wire hai woh bhi 5 saal se chal Raha hai. 4 sqmm par poora Ghar ka load aasani se chalta hai. Tube, fan ex. Fan k liye toh 0.5 sqmm hi kafi hota hai ya zayada se zayada 0.75 sqmm. Mota Mota hisab yeh hai k agar best quality ka copper wire hai toh 1 sqmm 10 A tak load le sakta hai.
3 hp=3×746=2238 watt=(2238/0.8)=2790 va hi hai. To current=(2790/200)=279/20=14 A hi hota hai to aap ko 3 sq mm copper wire hi lagana hai.Lekin input voltage 200v se kum nehin ana chahiye
Wo 4 se lekar 6 tak vary karta hai. Simplest way ke liye 5 hi Lena hota hai. Ye sab engg hai koi yaise nehin batata hai. Ye company kyun 3 sq mm ya 5 sq mm ki copper ki wire manufacture nehin karte hain. Jaise ki distribution transformer bhi 11/22/33/66/132 kva ka hota hai kyun ye sab 10/20/30/60/130 kva ka nehin hota ye sabke pichhe engg hi hota hai isliye
What will be current carrying capacity of two 4 sqmm wire. It will be equalant to 8sqmm wire. Which one will burn first due to over current. Single wire of 8sqmm Or 2 x 4sqmm wire = 8sqmm.
Ye vary karta hai. Aap ne bhi sahi kaha.Lekin kya ham ek wire ko full capacity me load current dena sahi hoga ji nehin . Wire ki longevity ke liye hamko 5 se multiply Karna padta hai
Very useful video dear brother. Very nice description. Keep it up .Thank you .
Thanks for watching 🙏🏻
😊😊@@CEFandBrandEdgeReviews
Thank you Sir for the valuable information
🙏🏻
Aam aadmi ke 3 bhk ke ghar me jaha 1 ac ya ek geyser, Iron, mixer grinder, room heater or Pani ka ek moter chalta hai waha Maine board se room ke boards me maximum 4 mm wire sufficient hota hai....AC or geyser dono ek saath to chalna nahi hai ....room heater bhi winter me hi chalega...1 mm for fan, tv, bulbs ke liye sahi hai jo room ke boards switch se point ko jayega.... Service wire ke liye 10mm ka aluminium wire use kare wo copper se sasta parega....
Hello paji ma punjab sa electrision jasa koi valding sat wali machine ha vo chalti ha double phase jab ham uski single wire par amp batati ha 25 amp ab ma es bat ka pata nahi chal raha ki 25 amp ki ha ya 50 amp ki jas koi ac hota vo late 7 sa 8 amp par vo chlta single phase par us pr lagate ha 2.50 mm ki wire ab ya janna chahata hi jo double pase wai machine ha jo 25 amp ki us par kitne mm ki wire lagau
Ha sir mare gharpe vayaring to nhi hay abhi par muje taatkal main vayar karna ahy to garpe to main apse pucha na cahta tha ke 1.00mm ka anchor ka varar us kar sakata ho muje 9 volteg ke balaf aur aur fen 3 hay to aur ek pani ki motar hay adhe ki to sir uas kar sakte hay batana to sahi rehmga sir kiya thenkue
Sir thank you very much,,, sir thank you very much,,, please put about more about electrical thank you very much I am from bangalore city,,, I will give you 5 stars
🙏🏻 Welcome and than you for watching
Good infourmatison.sir
Sir Induction me 10 Ampere current lgta h to fir hme konsa cable use Krna chahiye because me kbhi kbhi use krti hu
Very very useful. Skg
Very nice video
Dc. Grinder me kitna mm ka wire chayiye copper ka
Nice, thank you
Electric pole se meter tak ka kitne ka wire use krna chahiye
.75mm lap/fan. 1mm iron 1hp pump motor. 2.5 ac. 4mm Main swtich .
Sir mera meter load 3.5kw hai and 6mm service wire hai kya mein 2 split ac 1.5 ton wala ek saath use karu??
It will trip, load 5 kw karo, and limit other appliances.
Aaj kaal 2.5 mm mein AC, Geyser ka kaam ho jaata hai, iron, fridge & heater k liye 1.5 mm, baaki 1mm
bhai mere circuit me 24v 1amp rating hai konsa wire lu ? 1mmsq ki 1.5mmsq
Sir ye 5 se multiply aapne kese Kiya ye samajh mai ni aaya, digit 5 hi kyu li aapne multiply ke liye, aur digit kyu ni li,koi formula hai kya iska sir,ye please bata dijiye
its thumbrule
Ye sab +2 second year physics me formula hota hai jab hamne Ohms law padhate Hain tab conductance hi wire ki conductivity aur length aur CSA se kaise relate hote hain ham batate hain.jab wiring karogi copper se to conductivity to same aur length bhi same rahega to CSA se kitna current flow hoga ye sab value put karne ki baad me ata hai.yahan ye 5 constant nehin hai.jsise ki 4 sq mm copper wire me 24 se 27A tak aur 6 sq mm copper se 31 se 37 A tak current hi flow hoga
Sir, water pump ke liye kaunsa wire use karte hai
Nice and knowledgeable🎉
Nice
Sir 5 se multiply matlap nhi samja?
Be careful, some companies put misleading labels, when they mark 4 mm square, it may be far less.
Always use 10mm both wire from main meter to distribution box, after that you can use different guage wires
1 SQ MM WIRE 10 AMP LOAD LETA HAI
Kya hm pure Ghar me 2.5mm ke wire se waring kr sakte hai
Sir 6mmwire 5meter kitne ka hai
Thanks
Inverter ke liye kitne mm ka wire use kren......
1.5
22 amprer 3 ac ka load hai 4 mm wire pr chalega kya ??
Yes
Multiply by 5 ka formula Kahan se laye? Mere paas geyser hai 3000 w ka uske sath Bajaj company ne 1.5 sqmm ka wire dhiya hai aur woh 6 saal se chal Raha hai . Voltas ka 1.2 ton 1200 w ka ac hai uske saath bhi 1.5 sqmm ka hi wire hai woh bhi 5 saal se chal Raha hai. 4 sqmm par poora Ghar ka load aasani se chalta hai.
Tube, fan ex. Fan k liye toh 0.5 sqmm hi kafi hota hai ya zayada se zayada 0.75 sqmm.
Mota Mota hisab yeh hai k agar best quality ka copper wire hai toh 1 sqmm 10 A tak load le sakta hai.
Mere ko to 6 se batya hai, 5 se nhi
Sir 10 mm wire hm direct ghar ka connection pole se kar sakte hai???
Ha bhai
Pole se ghar ka connection 6mm wire se kr skte h kya
@@Rock-xw1ty bhai ispe 6kv load 24hr chal sakta hai kya
3hp single phase water pump k liye kitne mm ka wire achha hoga?
agar jyada dur nhi to 2.5 mm otherwise 4.mm
3 hp=3×746=2238 watt=(2238/0.8)=2790 va hi hai. To current=(2790/200)=279/20=14 A hi hota hai to aap ko 3 sq mm copper wire hi lagana hai.Lekin input voltage 200v se kum nehin ana chahiye
Kyunki ac me Power=voltage ×current× power factor hi hota hai.yahan avg power factor 0.8 hi liya hsi
Is this applicable for copper wire or aluminium wire
Service wire aluminium ka use hota hai.
Copper ka conductivity jyada hota hai aluminium se.
Why multiple 5 ?
Wo 4 se lekar 6 tak vary karta hai. Simplest way ke liye 5 hi Lena hota hai. Ye sab engg hai koi yaise nehin batata hai. Ye company kyun 3 sq mm ya 5 sq mm ki copper ki wire manufacture nehin karte hain. Jaise ki distribution transformer bhi 11/22/33/66/132 kva ka hota hai kyun ye sab 10/20/30/60/130 kva ka nehin hota ye sabke pichhe engg hi hota hai isliye
Ac ke liye 2.5 sq mm enough hai
What will be current carrying capacity of two 4 sqmm wire. It will be equalant to 8sqmm wire. Which one will burn first due to over current.
Single wire of 8sqmm
Or
2 x 4sqmm wire = 8sqmm.
Which wire is sufficient for OVEN ?
2.5 mm wire
Ok sir
0.5mm square can handle upto 5amp
Mubishar siraj khan electriction
It's not multiplying by 5 but by 6 like 1x6= 6Amp for 1 sqmm wire as per IS codes
yes absolutely correct, but it too depends on company, some offers upto 8-9 amps, but to be on safe side we take 6 amp
Ye vary karta hai. Aap ne bhi sahi kaha.Lekin kya ham ek wire ko full capacity me load current dena sahi hoga ji nehin . Wire ki longevity ke liye hamko 5 se multiply Karna padta hai
❤❤❤❤❤❤❤❤
झोल हे भाई
.1 गिजेर और 1 हिटर, इन दोनों को अलग अलग तार या एक ही तार मैं दोनों को जोड़ दूंगा बताओ ना
Mai 3 saal se 1 mm wire 16 amp pe use kar raha hu 😂😂😂😂
😂😂
Mera 1 qmm wire to 12 ampere pe hi heat ho raha hai😂😂😂
Or Mai 1 sal sa 1 ac ka liya 10mm wire use kar raha par fir bhi afsoos hai mujhe 16mm ya 25mm use karna cahiye the
4 mm wair har saman use kar sakte h. Bewakoof
Thanks
🙏🏻
❤❤❤❤❤❤❤❤❤