- In this video, we dive into the topic of chilled water flow rate calculation. Specifically, we focus on the GPM (Gallons Per Minute) per ton of refrigeration measurement. Understanding the flow rate is crucial for proper cooling system design and optimization. Join us as we explain the concept, provide step-by-step calculations, and offer practical tips for achieving optimal flow rates in your chilled water systems. Whether you're an HVAC professional or simply interested in learning more about cooling systems, this video will provide valuable insights. Don't miss out on this informative and educational content!
Don't forget to subscribe to the channel for more insightful videos on improvement and design.
You can watch more of the following Tanweer Ahmed's videos:
1. How to measure HVAC duct sheets?
Video's Link: • How to measurement HVA...
2. How to Prepare Measurement Sheet for Chilled Water Pipes
Video's Link: • How to Prepare Measure...
3. What is BOQ | How to Prepare BOQ | Rate Analysis of Bill of Quantity
Video's Link: • What is BOQ | How to P...
4. How to take off duct quantities from drawings? MEP quantity surveying
Video's Link: • How to take off duct q...
5. Project Construction Drawings types
Video's Link: • Project Construction D...
6. Project Closeout Requirements | Part-1
Video's Link: • Project Closeout Requi...
7. Project Closeout Requirements | Part-2
Video's Link: • Project Closeout Requi...
8. Construction Sequence of Projects | Section-1
Video's Link: • Construction Sequence ...
9. Construction Sequence of Projects | Section-2
Video's Link: • Construction Sequence ...
10. Construction Sequence of Projects | Section-3
Video's Link: • Construction Sequence ...
11. How to Prepare Interim Payment Certificate (IPC)
Video's Link: • How to Prepare Interim...
12. How to Prepare BOQ for HVAC Works in Urdu | Rate Analysis of Bill of Quantity
Video's Link: • How to Prepare BOQ for...
13. HVAC Basics: Air Changes per Hour and Calculating CFM of a Room
Video's Link: • HVAC Basics: Air Chang...
14. ASHRAE 62.1 Fresh Air Calculation Explained | HVAC Ventilation
Video's Link: • Fresh Air Calculation ...
15. Toilet Ventilation Design | Toilet Exhaust CFM Calculation
Video's Link: • Toilet Ventilation Des...
16. Kitchen Ventilation Design | ASHRAE 62.2 | Residential Kitchen Exhaust Air Calculation
Video's Link: • Kitchen Ventilation De...
17. Kitchen Ventilation Design | ASHRAE 62.1 | Kitchen Air Calculation
Video's Link: • Kitchen Ventilation De...
#TanweerAhmed #chilled #water #flow #rate #calculation #gpm #ton #hvac #mep #design #TR
= YOU CAN FOLLOW ME ON SOCIAL MEDIA =
LINKEDIN: / tanweer-ahmed-00142631
TELEGRAM GROUP: t.me/hvacmepenggg
INSTAGRAM: / tanweersethar
RUclips: / tanweerahmed
Thank you Brother for sharing valuable information.
JazakaAllah
Great explanation.
Thanks
V nicely and simply explanation. Way of speaking is absolutely amazing. Mashallah Keep it up Sir👏.
JazakaAllah
Amazing video thank you for sharing this information
Thank you
Superb
Thanks
Very impactful video
Thank you
Nice Work ✅
Thank you
شكرا
Welcome
Plumbing mein manhole se pipe slope kaise calculate krte ?
Watch my plumbing playlist for this topic
Nhi hai sir usmein calculation
Sir for pvc supply water pipe coming from soil i have a leakage so how much time should leave after change fittings and how much time should wait for observation after arresting leakage to put soil after excavation
🤔
@@TanweerAhmed i have water supply for irrigation ( water supply to plants in my project) so i found a leakage in this irrigation pvc line wch is underground.. i change pvc fittings and now how much time should i wait for that fittings to dry and after dry how much time i should keep that leakage part in observation by opening water supply ?
Dry time is mostly written on solution tin. Follow accordingly because each solution have different time for dryness.
@@TanweerAhmed ok sir and next after drying the solution how much time should we need to keep the leakage part in observation after water supply and i can't do leak test here because line length is v big and under ground.. so i think we can on the pump and see directly before back filling ?
@@adnanbinsaleemjabri7620 yes, before back filling, you must observe the leakage for half hour after running water in pipeline. Afterward back filling start, if satisfied.
بھائی جان میں آپ رابطےسے کرنا چاہتے ہو
Join my Telegram group
@@TanweerAhmed hi
10:00
⁉️
Very Informative Video
Thank you sir
JazakaAllah