HVAC Chilled Water Pipe Sizing | McQuay Pipe Sizer in Urdu/Hindi
HTML-код
- Опубликовано: 6 авг 2024
- This HVAC tutorial video is about HVAC chilled water pipe sizing, or chilled water pipe designing using McQuay Pipe Sizer or manual Carrier pipe size calculation through Carrier Chart Graph, presented in Urdu/Hindi. This information is also important for HVAC/MEP technical staff. In this video, I am sharing my experience and knowledge that I hope will be helpful for engineers and technical personnel who want to learn and grow in this field.
00:00 Introduction
00:39 How to calculate chilled water flow rate
02:19 converting ac tonnage to chilled water flow rate
03:35 How to calculate chilled water pipe sizing
04:02 ASHRAE recommendation of chilled water pipe sizes
04:45 Chilled water pipe sizing by ASHRAE chart
05:50 Chilled water pipe sizing by McQuay software
You can watch more of the followingTanweer Ahmed's videos:
1. Project Closeout Requirements | Part-1
Video's Link: • Project Closeout Requi...
2. Project Closeout Requirements | Part-2
Video's Link: • Project Closeout Requi...
3. Construction Sequence of Projects | Section-1
Video's Link: • Construction Sequence ...
4. Construction Sequence of Projects | Section-2
Video's Link: • Construction Sequence ...
5. Construction Sequence of Projects | Section-3
Video's Link: • Construction Sequence ...
6. Visit of Mechanical Workshop | Pipe Fabrication
Video's Link: • Visit of Mechanical Wo...
7. Visit of SASA Metal Industries for fans
Video's Link: • Visit of SASA Metal In...
8. What is BIM ? | Building Information Modeling
Video's Link: • What is BIM ? | Buildi...
9. Project Construction Drawings types
Video's Link: • Project Construction D...
10. How to measure HVAC duct sheets?
Video's Link: • How to measurement HVA...
11. How to Prepare Measurement Sheet for Chilled Water Pipes
Video's Link: • How to Prepare Measure...
12. HVAC Duct Design by Constant Velocity Method | McQuay Duct Sizer
Video's Link: • HVAC Duct Design by Co...
13. HVAC Duct Design by Equal Friction Method | McQuay Duct Sizer
Video's Link: • HVAC Duct Design by Eq...
14. HVAC Duct Design by Static Regain Method | McQuay Duct Sizer
Video's Link: • HVAC Duct Design by St...
#TanweerAhmed #hvac #mep #McQuay #software #hvacsoftware #pipe #design #pipesizer #chilledwater #pipesizing #pipedesign
= YOU CAN FOLLOW ME ON SOCIAL MEDIA =
WEBSITE: engineertanweerahmed.com/
FACEBOOK: web. EngrTanweerA...
INSTAGRAM: / tanweersethar
LINKEDIN: / tanweer-ahmed-00142631
RUclips: / tanweerahmed
TIKTOK: vm.tiktok.com/ZSJReMqYx/
TELEGRAM GROUP: t.me/hvacmepenggg Наука
Walekum asalaam wa rahmatullahi wa barkataa hoo
Mr tanveer sir bhut acha explaination hai apka sir
its great,i appreciated to you.
Allaha hafiz
JazakaAllah
Thanky sir for share your expert knowldegs with audience.
Alhamdullah
Thanks you so much sir .
May Allah bless you..
JazakaAllah
Hi, Thanks Tanweer Ahmed, was very good Basic example for the calculating the same.
JazakaAllah
I am watching your all vdos very easy understandable ❤️
JazakaAllah
Excellent information sir ji
Thank you
You doing good sir,. I appreciate your work...
Thanks
very nice than you
Thanks
Very help full video sir
Thanks
Sir, your videos are fantastic, but I don't know that from where I should start....ap jo video mention karte he tu uska link uper de dya kare please..so that we watch that video first and then come to this one
Thanks a lot and noted
Best explanation
Thanks
Very well explained Tanweer Bhai. M S Verma Delhi
Thanks a lot
Insightful sir. Please make a video on Pump head calculation for cooling tower pump and CHW primary & secondary pump.
I have uploaded cooling tower and chilled water pump head calculation. Visit my HVAC playlist
Thank you sir
Welcome
super sir
Thank you
Tanveer sahib...why cant v use pprc or hdpe pipe instead of MS pipe for closed or open circuit piping?
Google it or study ashrae standard
Thanks
Welcome
Video good
Thanks
Sir agar delta T in degree Celsius me h to , kaise lenge gpm calculate karne ke liye
Delta T in celsius should convert in degree F
How the chilled water gpm are calculated in design.
In heat load calculation, we calculated cfm or TR.
Using this how to calculate the chilled water requirement for each units.
In this video's starting, I informed formual that Flow (GPM) = TRx24/Delta T. From this equation you will find out gpm
Sir how to dwnld and purchase mcquay software for calculate duct sizing and child water pipe line size?
Share email, I will send free softwares
Sir ek question hai.
Wall corner se diffuser ke end tak Kitna gap lete hai minimum or maximum...?
The area served by the diffuser should be divided into equal squares of rooms
sir return ka pipe dia same hoga? jw supply chilled water ka hai wohi return ka bhe hoga?
Supply and return pipe dia remain same at AHU connection and main pipeline dia increased according to AHU quantities and their flow
@@TanweerAhmed thank u sir
If pipe dia is above the 2 inch dia then what should be the velocity ??
Then you will consider velocity, further explained in video
Hi Sir, kisi ek real project ki pipe sizing karke bata sakte hai kya video me please. Ya fir ek drawing send kar sakte hai kya jo project apne execute kiya hoga practice karne ke liye please. Thank you.
Follow this procedure on drawing
@@TanweerAhmed I don't have drawings Sir.
@@GaneshKamble-gd9cg In my playlist of HVAC "how to read HVAC drawings" in each video's description link is attached for drawing free download
@@TanweerAhmed Thank you so very much Sir.
Sir, how do we guess Pipe dia less than 2 inch or not for certain GPM flow water?
You will use values in McQuay software then you'll understand
@@TanweerAhmed ok sir
@@sumanjana3862 Welcome
sir ya kis tara decide karain gy pipe diameter 2" hai ya us sy kaam zyada kahin par apny friction loss ko consider kia hai aur kahin par velocity ko ya kis tara decide krain gy
It will be experience you when calculate repeatedly according to flow and friction loss
@@TanweerAhmed samhj gaya sir, bht shukriya
Welcome
Hello sir pls share graph and pipe sizer application
?
I mean friction chart and maccque pipe sizer
Visit MEP Work website and download
sir ye formula me 24 kaha se aaya
Tonnage of chiller = (500 x gpm x Delta T (F))/12000
Tonnage of chiller = gpm X Delta T(F) / 24
GPM= Tr X 24/Delta T (F)
@@TanweerAhmed bhai in the formula what is 500
The 500 in the formula is a constant representing the heat capacity of water, which is approximately 500 British Thermal Units (BTU) per pound per degree Fahrenheit (BTU/lb°F).
@@TanweerAhmed bhai can you make video for hvac material(pipe,ducting,fitting etc) estimation manually or through software which is used nowadays.
@@iftikharbangash5760 My videos are available: How to prepare HVAC BOQ and like firefighting BOQ. Kindly review. If any special working want then let me know. I will try
Very good brother 😊
جزاک اللہ خیر
@@TanweerAhmed Tanveer bahi mein installer raha hun Projects py qatar aur saudia mein 10 saal bs dill mein yei tha k designing seekhni hai wo kaam bi ap nay shuru kara diya thank u soo much
I am also learning
@@TanweerAhmed Tanveer bahi kya mujhay Sb softwares ki list mill sakti hai jo ap use kar rahay hai .taky mein same spec's k software download kar sakon .