  • Starting current is around 1600 Amps but this meter cannot show you more than 450A because limitations of CTs

Комментарии • 192

  • @flaplaya
    @flaplaya 2 года назад +300

    Got to love a soft starter that thing would have growled so bad without that type of starter bringing it into mains. 420 amps still! Awesome and smooth system

    • @Willeexd1337
      @Willeexd1337 2 года назад +15

      Starting current is around 1600 Amps but this meter cannot show you more than 450A because limitations of CTs

    • @KutWrite
      @KutWrite 2 года назад

      Yeah, I thought that meter was showing amps, not volts as in the title.

    • @alouisschafer7212
      @alouisschafer7212 2 года назад +2

      It must have a start to delta starter

    • @JohnnyJr396
      @JohnnyJr396 2 года назад +1

      Came across a 100 hp with ramp speed setting way too fast on vfd. Belts sounded like a car doing a burnout on start up .

    • @akio2589
      @akio2589 2 года назад

      Wouldn't be pulling 1600 amps inrush with a soft start. It's a wye-delta start.

  • @adamk203
    @adamk203 2 года назад +309

    Crazy to see a motor that size drawing more power than an entire city block...

    • @sus7382
      @sus7382 2 года назад +22

      Just wait till you see FPV quads, some X class rigs with motors just the size of your hand can pull 400+ amps total at full throttle

    • @solaroid4442
      @solaroid4442 2 года назад +34

      @@sus7382 Not at 400v 3phase

    • @sus7382
      @sus7382 2 года назад +22

      @@solaroid4442 50v 3 phase brushless pulling that much is still VERY impressive

    • @jannsen5177
      @jannsen5177 2 года назад +2

      @@sus7382 50v? Where? 😂

    • @williamwalters3796
      @williamwalters3796 2 года назад +1

      @@sus7382 on tiny little drone motor wires? Idk
      Edit: for anyone curious, I don’t know the specs of this drone setup but it’s impressive. ruclips.net/video/87JJ7WkRpLc/видео.html

  • @jonasklemm32
    @jonasklemm32 2 года назад +621

    we have a 600kw motor for a compressor. When the engine is started, the light in the entire system briefly dims.

    • @rthony7780
      @rthony7780 2 года назад +26

      you should see our bowthruster motor get into 1200A when we maneuvered and almsot crashed to berthed fishing vessels

    • @ligmayeye186
      @ligmayeye186 2 года назад +18

      inrush current can be crazy

    • @debug8377
      @debug8377 2 года назад +8

      what's the compressor for?

    • @jonasklemm32
      @jonasklemm32 2 года назад +17

      @@debug8377 thermal wastewater treatment

    • @debug8377
      @debug8377 2 года назад

      @@jonasklemm32 ah okay

  • @94sn95gt
    @94sn95gt 2 года назад +192

    Our hammer mill used one of these motors. The high light of my day was starting it up at 5 am. You could hear that thing wind up a half mile down the street.

    • @wildfirephoenix2262
      @wildfirephoenix2262 2 года назад +7

      That's one hell of an alarm clock for neighbors within half a mile lol XD 🙊🤭😆😂😂🤣

    • @johnpekkala6941
      @johnpekkala6941 2 года назад

      The motor noise is the least concern if they can hear the motor starting up by itself. When a hammer mill is crushing scrap it makes a noise like if there was a waterfall of metal scrap thundering down from at least 100 meters. Its insanley loud so I say poor neighbours living close to that. They have to be deaf by now or at least really mad at the constant deafening clattering noise going on for hours a day all over their neighbourhood from morning to evning! ruclips.net/video/evXay0YZwFE/видео.html Hammermill startup vs crushing. The difference in noise. You dont want this anywhere near your neighbourhood!

  • @blendpinexus1416
    @blendpinexus1416 2 года назад +51

    woah, seeing the amps dip down to running very sharply as the motor syncs to the power input. very neat

  • @qua7771
    @qua7771 2 года назад +5

    I used to rewind motors like this. It takes me back.

  • @nidoshardwar3465
    @nidoshardwar3465 2 года назад +39

    1600 Amp @ 400V. thats nutty

    • @Txepetxcc
      @Txepetxcc 2 года назад +1

      Where do you get 1600A from?

    • @Txepetxcc
      @Txepetxcc 2 года назад +10

      It’s 231Amp line current in Y configuration. In Delta configuration is 400Amp . So no idea where you got the 1600Amp from. Meter even reads only up to 800A .

    • @oiytd5wugho
      @oiytd5wugho 2 года назад +4

      @@Txepetxcc it's the inrush current

    • @Txepetxcc
      @Txepetxcc 2 года назад +3

      @@tbuitendyk oh wow. Well, that should be it 😝. Poor CTs

    • @jace_Henderson
      @jace_Henderson 7 месяцев назад

      @@Txepetxcc 1600 amps came from the description

  • @iceman7975
    @iceman7975 2 года назад +63

    star delta start quite smooth actually, high inertia load.

  • @2loco
    @2loco 2 года назад +4

    I've got a 2 horse power air compressor. I'm pretty happy with it. Lights dim when it starts direct on line 🤣🤣

    • @2loco
      @2loco Год назад

      @@liam3284 single phase

  • @squidwardfromua
    @squidwardfromua 2 года назад +61

    160 kW is 217 hp
    that really demonstrates how powerful hypercars with lots of hundreds of hps are

    • @not0evn
      @not0evn 2 года назад +8

      I agree. When I was younger I used to think "wow, a Corvette can make enough power to run a Wal-Mart"
      Not sure if that's actually true, but it seems plausible. 😃

    • @ronaldwoofer5024
      @ronaldwoofer5024 2 года назад +2

      @@not0evn its like big semi trucks, they are like 300hp but they move tons of stuff. no way a corvette can do that.
      gatta look at torque as well when determining stuff like this

    • @not0evn
      @not0evn 2 года назад +4

      @@ronaldwoofer5024 how much torque does your average Wal-Mart consume?

    • @ronaldwoofer5024
      @ronaldwoofer5024 2 года назад +4

      @@not0evn 2 torque a second

    • @beanapprentice1687
      @beanapprentice1687 2 года назад +3

      @@ronaldwoofer5024 it’s horsepower that matters. You can make any amount of torque with gear ratios. The reason why the corvette can’t pull as much as a semi is because it’s first gear doesn’t amplify its torque nearly as much as a semi’s first gear does. But if you swapped a 500hp corvette engine into a 300hp semi, the semi would accelerate faster and have a higher top speed.

  • @ultimateearrapechannel31
    @ultimateearrapechannel31 2 года назад +6

    ohhh my go-cart motor. just bought it on amazon. should go a solid 1000mph

    • @bakkywlu326
      @bakkywlu326 2 года назад +1

      Don't tell the feds about the mini nuclear fusion reactor you bought to power it :)

  • @georgieippolito9924
    @georgieippolito9924 2 года назад +26

    don't you just love the sounds of engines starting up?

  • @nightmareinaction629
    @nightmareinaction629 2 года назад +8

    We have a 263kw motor but sure as he'll doesn't start like this. It has a vfd which stops that over current draw. Not sure why one hasn't been installed here yet cause it sure helps with the life of the motor

  • @redsquirrelftw
    @redsquirrelftw 2 года назад +9

    Beautiful sound.

  • @manikandarajan7928
    @manikandarajan7928 2 года назад +5

    Wow... our household submersible pump start and run on 14 amps. But this industrial boy start at 400+ amps..

  • @kampokez4583
    @kampokez4583 2 года назад +1

    Old school technology! Just use a soft start technology!

  • @rolandsebestyen7774
    @rolandsebestyen7774 2 года назад +1

    This sound is like, I'm sitting in an M62 Loco!😀

  • @cosmicinsane516
    @cosmicinsane516 2 года назад +8

    Electric company demand charges ringing like a slot machine jackpot. Lol imagine without the soft start.

  • @DielectricVideos
    @DielectricVideos 2 года назад +21

    What causes the brief transient at 0:54? Was there a momentary insulation failure, or was some auxiliary winding switched in/out?

    • @austroval4941
      @austroval4941 2 года назад +33

      I think that was the Moment the Motor was switched from Star to Delta configuration

    • @DielectricVideos
      @DielectricVideos 2 года назад +1

      @@austroval4941 Ahh, that makes sense!

    • @TechOne7671
      @TechOne7671 2 года назад +3

      Star delta starter changing over.

  • @mayurchudasma8300
    @mayurchudasma8300 2 года назад +8

    Start with damper close and open it after acceleration

  • @cbrunnem6102
    @cbrunnem6102 2 года назад +5

    big motors need to be on 4160 if at all possible. they ramp up so much quicker. we have 3x 900hp motors at work that ramp to full speed in under 5s on their starters. they pull about 400amps at 4160 on startup. it's wild

    • @thelastdirewolf3587
      @thelastdirewolf3587 2 года назад

      What's 4160

    • @cbrunnem6102
      @cbrunnem6102 Год назад

      @liam3284 4160 in the us is line to line which is what I meant. it's a difference to how Europe and other places measure it which as you mention is line to neutral.

  • @mikatomik5532
    @mikatomik5532 2 года назад +2

    Y’all should see when they fire up the mixer motors for the banbury’s at BF Goodrich. I don’t know the wattage but they run on 4160v and have two of them connected shaft to shaft to spin a gearbox

    • @paulmorrow8372
      @paulmorrow8372 2 года назад

      4160 is considered “medium voltage”. I toured a few manufacturers over the years with these. I didn’t even want to look at them!

    • @mikatomik5532
      @mikatomik5532 2 года назад

      @@paulmorrow8372 Oh yeah. I’m an industrial mechanic at the BF Goodrich Fort Wayne plant. I’ve walked through the high voltage room (they call it high voltage there) to verify lockouts with the electricians for some work and man… that whole room hums and vibrates. Scary stuff

  • @MenzelMotors
    @MenzelMotors 2 года назад +8

    interesting insight, thank you

  • @ecaparts
    @ecaparts 2 года назад +28

    I assume the Amp meter is only reading 1 of the 3 phases? Wow, what a grid killer!!

  • @xXstrattXx
    @xXstrattXx 2 года назад +2

    I've got 1120 kilowatt 4160v 1500 hp blower motors at work that are terrifying to be around especially since I've seen what they do when the fan comes apart

  • @gabrielv.4358
    @gabrielv.4358 2 года назад +3

    This sounds like some space ship engine or something like that. Amazing

  • @segabi1
    @segabi1 2 года назад

    Sounds like a space ship startup

  • @zaclejeune
    @zaclejeune 2 года назад

    Would make a good ceiling fan

  • @tuyon
    @tuyon 2 года назад +3

    Хороший мотор. Его бы на медяху разобрать.

  • @SnowJoe1
    @SnowJoe1 2 года назад

    I'd like to see this size motor used on a carter style siren.

  • @whaBaaAAAM
    @whaBaaAAAM Год назад

    I don't know what's wrong with the title and what is shown in the vid. Current meter shows 120 amps (0:50) at terminal rotation speed and the title says 400v, so the power rating comes to 400x120=48000watts, so 48000/1000 gives 48kW. How 160 kW?

  • @el-shesma3733
    @el-shesma3733 2 года назад +1

    The title is all wrong, if it really operates at 400 volts, this means when the motor settled on approx 150 amps in the video it consumes about 60 kw, and started up at 350 amps or 140 kw, so it is completely far from 160 kw because the power of motors is originally measured when settling, not during starting up

    • @Kokosnuss_HD
      @Kokosnuss_HD 2 года назад

      why would you use 3 ampere Meter when you can use one and just multply it with 3 because 3 phases?

    • @el-shesma3733
      @el-shesma3733 2 года назад +1

      @@Kokosnuss_HD ah, I forgot that

  • @steffen1182
    @steffen1182 2 года назад

    nice one 🙂

  • @YodiePS21
    @YodiePS21 2 года назад

    It's said on description "1600 A"

  • @vernacular1483
    @vernacular1483 2 года назад +2

    Good sound

  • @zaxarispetixos8728
    @zaxarispetixos8728 2 года назад +2

    It works fir a long time at 400 you don't trip any safety?

    • @Smokes-1000
      @Smokes-1000 2 года назад

      I would say it is drawing more than 400 amps for a little while if you read the description is says about it drawing 1600 amps but that can’t be displayed easily

    • @zaxarispetixos8728
      @zaxarispetixos8728 2 года назад +1

      @@Smokes-1000 lol

  • @XPLOD2556
    @XPLOD2556 2 года назад

    I want a fan like that for my house

  • @andersdoesthings9309
    @andersdoesthings9309 2 года назад +2

    What is this used for?

  • @SH00T_TH3PUMP
    @SH00T_TH3PUMP 2 года назад +2

    Do it without the soft start. Throw everything you have at it at a dead stop.

    • @akio2589
      @akio2589 2 года назад +1

      It doesn't have a soft start. It's a big-ass blower with a lot of inertia, and a wye-delta starter.

    • @SH00T_TH3PUMP
      @SH00T_TH3PUMP 2 года назад

      @@akio2589 Throw absolute full power at it at a dead stop!! 😍

  • @najeebullah1155
    @najeebullah1155 2 года назад

    Why at startup it takes more current the slowly gets down?

  • @nostopengine103
    @nostopengine103 2 года назад

    Что он приводит в движение , для чего этот двигатель ?

  • @gabriellenhart1
    @gabriellenhart1 2 года назад +1

    Ele apanhou um pouco no começo, mas depois foi embora.

  • @Zlobusz
    @Zlobusz 2 года назад

    Любая индуктивная нагрузка при старте в разы превышает свой номинальный ток. Мотор то по итогу не более 48 кВт потребляет.

    • @Relict777
      @Relict777 2 года назад

      До 7 раз пусковой ток выше номинального

  • @thanhthanh-vh5hu
    @thanhthanh-vh5hu 2 года назад +4

    can you do some video about circuit start with induction motor to 150kw and higher???

    • @StakrCZ
      @StakrCZ 2 года назад +1

      Looks like direct start. I see 2 cables but don´t hear any sound change like with star-delta configuration.

    • @inductoservice9866
      @inductoservice9866  2 года назад +10

      @@StakrCZ Y -> D happens at 0:55. That is why amp meter jumps.

    • @StakrCZ
      @StakrCZ 2 года назад

      @@inductoservice9866 yeah true :D

    • @typgamer
      @typgamer 2 года назад +1

      Its a regular timer controlled star delta circuit. Its a lot bigger in size of cause because of the giant amperage beeing drawn.

  • @SOU6900
    @SOU6900 2 года назад

    So what's this motor powering?

  • @ZLDSmogless
    @ZLDSmogless 2 года назад

    What is the motor powering?

  • @markusfpv1349
    @markusfpv1349 2 года назад +4

    I would slap that motor cover just for the sake of it

    • @user2C47
      @user2C47 2 года назад +7

      @T o b i L o s GaMiNg Then you immediately take the equipment out of service and start a major investigation. The body of a motor should NOT be live. If the company won't fix it, call OSHA.

  • @sparkythebuilder
    @sparkythebuilder 2 года назад +1

    Pretty sure the A on the gauge is amps not volts.

  • @cocio1231
    @cocio1231 2 года назад

    the sound its like horror movie

  • @Tadesan
    @Tadesan 2 года назад

    Can somebody confirm-
    It draws 400 Amps for a minute. Is that 7 Amp hours of energy? That's like 3 18650 batteries. Not too bad. 120 Amps of that is load however...

  • @burningdust
    @burningdust 2 года назад +1

    1600 amps starting current at 400VAC?? What a beast!

  • @albertlopez6620
    @albertlopez6620 2 года назад +4

    Estos motores eléctricos para grandes winches arada necesitan arrancador y mucha más potencia eléctrica
    Los pequeños no incluso si le dejas el cables destensado unos metros no subiré al arrancar pero estos el arranque es bestial !!
    Necesitas más potencia eléctrica pero dan producciones para ciudades

  • @littlepastelkitten
    @littlepastelkitten 2 года назад

    What's it for?

  • @gavendb
    @gavendb 2 года назад

    wye start delta run?

  • @ericmoeller3634
    @ericmoeller3634 2 года назад

    whats that blower for

  • @EIRK2046Y
    @EIRK2046Y 2 года назад

    ABB frequency inverter plus motor.

  • @newbieberkarya6442
    @newbieberkarya6442 2 года назад

    Kabel apa dah yg bisa buat 1600 Ampere ?

  • @albertlopez6620
    @albertlopez6620 2 года назад

    Ese motor podría con las aradas de un tractor de los más grandes
    Para aprovechar una arada de un tractor de los mas grandes y no reducirla puedes reducir la velocidad de enrrollado de cable asta que con esa potencia pueda

  • @heartofthetraitorAMINE
    @heartofthetraitorAMINE 2 года назад +2

    Démarrage progressif

  • @ryanmamase5476
    @ryanmamase5476 2 года назад

    How to account for setting time start delta system...?

    • @akio2589
      @akio2589 2 года назад

      Probably current-based switch setup.

  • @poluprimatpoluprimat2517
    @poluprimatpoluprimat2517 2 года назад

    Пусковой ток - ОК.

  • @scifactorial5802
    @scifactorial5802 2 года назад +1

    Then consider you have two more even more powerful motors in a high end Tesla. And that starting them up is just a matter of extending your foot slightly.

  • @UmbreWolf
    @UmbreWolf 2 года назад

    that aint nothing, try a half megawatt Induced draft fan. You can FEEL one of them starting

  • @siukeung0714
    @siukeung0714 2 года назад +4

    This motor for what? Fan ?

  • @magnetron6
    @magnetron6 Год назад

    electric bill go brrr

  • @chriauc2976
    @chriauc2976 2 года назад

    Cute.
    Moving on

  • @harry2928
    @harry2928 2 года назад

    = what braking horsepower

    • @K2teknik.
      @K2teknik. 2 года назад +5

      about 215 BHP, or 218 HP

    • @harry2928
      @harry2928 2 года назад +1

      @@K2teknik. tank you

    • @e-berry
      @e-berry 2 года назад

      @@K2teknik. "Tank you". Be aware, he wants to kill you with a tank I guess

  • @quadowejanusze
    @quadowejanusze 2 года назад +3

    Tesla goes brrr

  • @jirkajavurek1094
    @jirkajavurek1094 2 года назад

    i dont want to pay electricity bills :D

  • @ВадимААА-х9я
    @ВадимААА-х9я 2 года назад

    75 квт ...

  • @vencavales391
    @vencavales391 2 года назад +1

    Ahoj, zřejmě nechápeš vztahy mezi U, I, P, atp. Výkon motoru je cca. 83,1kVA !!! Pokud je U opravdu rovno 400V

    • @inductoservice9866
      @inductoservice9866  2 года назад +5

      Yes. Nominal power is 160 kW but because there is no work load, motor takes only 120 amps at the beginning (after motor is started). sqrt(3) x 400 V x120 A = 83,1 kVA.

    • @StakrCZ
      @StakrCZ 2 года назад +1

      startovací proud je vždy několikanásobně vyšší než provozní hlavně záleží na zátěži a zde evidentně roztáčí něco hodně těžkého. V práci máme například 1050kW motory na 6kV a ty mají jmenovitý proud 145A ale při rozběhu berou 400A (roztáčí těžkou vrtuli ventilátoru, viz. můj kanál)

    • @vencavales391
      @vencavales391 2 года назад

      @@StakrCZ Hmm, jaká je spojitost s tímhle ? Nikdo se tady nemluvil o startovacím proudu.

    • @StakrCZ
      @StakrCZ 2 года назад

      @@vencavales391 pardon VA/W nějak mi to ulítlo to se po pivkách stává 🤣

  • @Relict777
    @Relict777 2 года назад

    This motor 16kw not 160kw

    • @akio2589
      @akio2589 2 года назад

      It was pulling 100 amps @ 400V once it got running... That's 40kW there.

  • @Qsams7159
    @Qsams7159 2 года назад

    Motor control is to confusing

  • @АлександрБаштовой-ш7ш

    Чё-то он маловат для 160кВт

  • @jamestegarden2584
    @jamestegarden2584 2 года назад +3

    Use a vfd

  • @alexmax8844
    @alexmax8844 2 года назад +1

    Да он максимум от 6 кВт до 15, какие 160? Сказочник.

    • @dmitriykolesnik4462
      @dmitriykolesnik4462 2 года назад +2

      Ну, если верить амперметру, потребляемая примерно столько и есть.

    • @alexmax8844
      @alexmax8844 2 года назад +1

      @@dmitriykolesnik4462 Вольтметр ещё должен быть чтобы я верил. Тогда и мощность реальная. А сетевое напряжение это не показатель.

    • @Игорь-у8р1ю
      @Игорь-у8р1ю 2 года назад

      400 ампер пусковой ток , потом 120 на амперметре после разгона , киловатт на 60 максимум этот двигатель .

  • @kussifury
    @kussifury 2 года назад

    160kw = 140Amps hahahaha

  • @oOBassKillOo
    @oOBassKillOo 2 года назад +5

    400a*400v=160kw 😳

    • @oOBassKillOo
      @oOBassKillOo 2 года назад

      @@inarinukka7729 3 Phases with 230 Volt each Are 400 Volt.

    • @garsto
      @garsto 2 года назад

      @@oOBassKillOo A*U*cosф*√3=S(P)

    • @StakrCZ
      @StakrCZ 2 года назад +2

      @@oOBassKillOo 3 phase 400v between phases. 230V it´s between phase and earth (neutral)
      Normal voltage here it Europe.

    • @Rolhenw
      @Rolhenw 2 года назад

      If you read the description, you will see that it draws 533A per phase at start, 1600A in total, so it draws 640kW!

  • @stevendegreef93
    @stevendegreef93 2 года назад +2

    Nothing to do with “400V” It draws 400Amp at start, voltage will be way lower

    • @DanielLamando
      @DanielLamando 2 года назад +3

      How do you know? 400V AC three phase is common in various countries, even in home kitchens

    • @Rolhenw
      @Rolhenw 2 года назад +1

      It draws 400A, 133A per Phase when its running (400V), thats 160kW, like the Video says. If you would read the description, it draws about 533 Amps per Phase at start (400V, too)! Thats 1600A and 640 kW. I dont know how you get the idea that a 400V motor would run at a lower voltage, you always run a motor at a constant voltage and change its power by regulating the amps.

    • @Rolhenw
      @Rolhenw 2 года назад +1

      Three Phase AC always runs at 400V, thats constant and standart here in europe.

    • @gabrielv.4358
      @gabrielv.4358 2 года назад

      @@DanielLamando not in Brazil. And for real, if 400v were mains, ah.. that would be a mess!

    • @mrfrenzy.
      @mrfrenzy. 2 года назад

      @@gabrielv.4358 sure you have 110/220V at home just like the USA, but if you visit a factory in Brazil you will see that they have 400V power for all their big motors.
      In Europe we just run the same voltage both at home and in factories: 240/400V. 240V is for all regular wall sockets, 400V for our water heaters, well pumps etc.