  • This lecture discusses the procedures involved in sampling and analysis of SO2 and NO2 in ambient air.

Комментарии • 15

  • @rajkumarshukla6417
    @rajkumarshukla6417 2 года назад

    Very much thank you, Sir.

  • @prahalad7826
    @prahalad7826 2 месяца назад

    Request to provide the make and model details of impinger box to control temperature of absorbing solutions

  • @tamilsciencedigestchannel8456
    @tamilsciencedigestchannel8456 Год назад

    very nice class sir it would be helpful for me to know more about so2 anf no2 pollution.

  • @pavankumar-yv7ev
    @pavankumar-yv7ev 6 месяцев назад

    Very good video sir on this testing methods but kindly tell how to make calibration curve and calibration standards because without this all procedure is incomplete.

  • @brightenvirotech6584
    @brightenvirotech6584 10 месяцев назад

    Good effort & Very informative. At 21th minute, please throw some more light on the volume of air sampled.

  • @Filipe.Mobilitex
    @Filipe.Mobilitex 8 месяцев назад

    Very good class. Could you help me with a question, please? How is the CEMS system calibration process carried out?

  • @yagnadipsinhvala5171
    @yagnadipsinhvala5171 9 месяцев назад

    Thank you

  • @pavankumar-yv7ev
    @pavankumar-yv7ev 5 месяцев назад

    Kindly tell the how to prepare calibration factor without this all analysis procedure is incomplete

  • @gabrielpetricec2163
    @gabrielpetricec2163 Год назад

    Hello
    Sorry for disturbance
    I Have read your standard 1090 în which are presented Methode for the determination of diferent gases
    I am interesed about áll gases formula determination
    For Example
    346200 for the Hydrogen
    3098 for the carbon monoxide
    1039 for the carbon dioxide
    2784 for the mercury
    How these values where determinated ?
    Thank You in advance for your answers

  • @subratranjantripathy3738
    @subratranjantripathy3738 Год назад

    What should be the flow rate for the ambient air quality (24hr ) monitoring,
    Weatger it is 1 or 0.2 lpm?

    • @ayabass
      @ayabass Год назад

      1L/min

    • @prahalad7826
      @prahalad7826 2 месяца назад

      0.2lpm is preferred for 24 hr sampling

  • @AnisurRahman-gp1bu
    @AnisurRahman-gp1bu Год назад

    How to determination of calibration factor

    • @brightenvirotech6584
      @brightenvirotech6584 10 месяцев назад

      plot the graph of Ab vs Conc. Draw a best fit straight line. Determine the slope. CF=1/Slope

  • @monikakubavat4391
    @monikakubavat4391 Год назад +1

    Demonstration video need more understanding and clarity