Normaly open means ther is no electricity going through and normaly closed that electricity is going through, you have than mixed up your video and its exactly the opposite. 🤔 If the switch reaches 93°c than the electricity runs through, that's normaly open switch. If you have a normally closed switch it would be by 93°C open the circuit and wouldn't let any electricity through. For a water heater you would need than a normaly closed switch with 105°c that than switches of when the water boils to about 105°C ± the error % Procentage. But I could be wrong with my migraine right now. 😔
Thanks for the video. I want to replace a thermal fuse 250v 169c with this but the one that I found has a spec of 250v 40-180c (175c), what does this spec mean?
Please advise Thermostat model for switching on kitchen exhaust fan at higher temperatures in room and cut off when temperature reaches below set temperature.
Bro for This project I think it's not Suitable . May bro you know about thermistor shape like resistor is good for this project and Transitors and relay needed or maybe triac also work Bro Thanks for great comment Bro
is there any way to add it to a buzzer? so if the temperature gets to the set amount on the switch, the buzzer starts to ring? this is the only video that I found that shows something useful, thank you.
So if a thermostat is set to 60 degrees and the temperature drops, the contacts close and the heat comes on. But what if you want to go from 60 to 70 degrees, how do the contact close when the heat is rising rather than falling? Thanks
You need the thermostat that works in that Rang you need, otherwise you need a temperature controller unit if you want to change the temperatures manually.
A crude demonstration, but works great. Thanks for taking the time to post a video!
Thank you so much Bro ❣️
Normaly open means ther is no electricity going through and normaly closed that electricity is going through, you have than mixed up your video and its exactly the opposite. 🤔
If the switch reaches 93°c than the electricity runs through, that's normaly open switch.
If you have a normally closed switch it would be by 93°C open the circuit and wouldn't let any electricity through.
For a water heater you would need than a normaly closed switch with 105°c that than switches of when the water boils to about 105°C ± the error % Procentage. But I could be wrong with my migraine right now. 😔
Yes that's the same thing I learned. This video got me confused.
You're correct. This video made me confused also.
Thanks for confirming what i suspected
Thanks for the simple and easy to understand video without unnecessary stuff!
Simple and clear demo, no bullshit like many others... Thank you
Thanks for the video. I want to replace a thermal fuse 250v 169c with this but the one that I found has a spec of 250v 40-180c (175c), what does this spec mean?
What is the difference between ksd201 and ksd301? I need 201 for water heater but I am able to find only 301 around me, can I use it?
can I use ksd 301/302 for dc 12v/10amh?
Yes Can
how do i wire this corrctly ?
its just the + wire connecting to either one of the plugs right ? so when it closes, my fans should start ?
Brother normally open (NO) means not short and normally close means short (NC) Right?
Yes dear
@@creativechannelpro371 Then you have it wrong in the video. Right?
Does it mean I can use the 250v ac version on 12v dc and lower? 🤔
Yes ofcourse dear
So Sorry for late reply
Soo, 250v is the max voltage you can use this thermostat, then i can use it on 120v right??
The only useful video on the topic! Bless up
Thanks bro ♥️☺️🤗 please keep Support Bro
Please advise Thermostat model for switching on kitchen exhaust fan at higher temperatures in room and cut off when temperature reaches below set temperature.
Bro for This project I think it's not Suitable . May bro you know about thermistor shape like resistor is good for this project and Transitors and relay needed or maybe triac also work Bro Thanks for great comment Bro
Bro See project in video ntc thermistor may help you
ruclips.net/video/JIq5YdayIeI/видео.html
Thank you.
Welcome bro
I bought KSD302 and test it with the heater. The two terminals become extremely hot and I'm afraid it could burn the cable.
Can u show how to put temperature display too with this set. But say when hot about 50 Celsius then it will turn it on.
Bro You need display temperature meter and 50Celsius Thermostat
@@creativechannelpro371 can u make a video how to do this
Hi, I was wondering if it clicked when it got to the temperature
Yes you right friend click sound mean open or close
شكرا جزيلا الله يرضى عليك الشرح بسيط ووافي
Great video ☢️
About Thermostat ❤️
🥰thanks
is there any way to add it to a buzzer? so if the temperature gets to the set amount on the switch, the buzzer starts to ring?
this is the only video that I found that shows something useful, thank you.
Yes bro too easy it's work like normal switch connect buzzer to battery and attach sensor like we attach Switch Thank You Bro
@@creativechannelpro371 your really helpful thanks
Welcome my friend 😊
Thanks for making this video💓💓
Thanks my bro
The boyband really brought the thermostat video to another level and nobody thanks you
So if a thermostat is set to 60 degrees and the temperature drops, the contacts close and the heat comes on. But what if you want to go from 60 to 70 degrees, how do the contact close when the heat is rising rather than falling? Thanks
You need the thermostat that works in that Rang you need, otherwise you need a temperature controller unit if you want to change the temperatures manually.
Yes dear Name SSR temp controller
THX Bro
Welcome bro
I want to have the fan come on at 80 degrees but stop at 70 degrees . To put in a solar heater , with a solar panel as power
Nice
😊 Thanks
Which one is N which one is L
thank
Hi i am blue from among us
Thanks bro welcome
LOL
Thanks for comment bro