Cutting Length of Column | Footing to Plinth | Staggered bar in column | Non Typical

Поделиться
HTML-код
  • Опубликовано: 20 янв 2025

Комментарии • 89

  • @EverythingCivil
    @EverythingCivil  4 года назад +4

    Hello friends this a reupload as I missed some parts. I believe showing correct and legit content is most important therefore I :have corrected and uploaded again for you guys. It is from 4:53 to 7:32. Thanks for watching. Love u all.

    • @kaakib8841
      @kaakib8841 3 года назад

      Sir
      Floor to floor height... Inner to inner distance lenge na?

    • @kaakib8841
      @kaakib8841 3 года назад

      Aapne plinth k top se slab ka top liya huwa hai

    • @azharnalbandh4029
      @azharnalbandh4029 3 года назад

      @@kaakib8841 in to in floor to ceiling ho jayga, think about it

    • @anuragkhati4547
      @anuragkhati4547 2 года назад

      Sir if bars are of different dia then how do we adjust the cutting length

    • @vitthalpatil1974
      @vitthalpatil1974 2 года назад

      column size is 350mm*2750mm. 34 bars of 20mm dia are vertical bars . cover is 75mm. Stirups bars are of 8mm dia. Master ring is easy to calculate but i m having problems with link bars. So plz tell me how to calculate Cutting length of link bars in column. There are 3 rings in which 4 bars are set i.e 12 vertical bars are in 3 rings and 3 vertical bars are in one ring. Total 15 and Master ring includes 2 vertical bars . Total 17 and similarly 17 bars on others sides.

  • @hz8200
    @hz8200 4 года назад +1

    Thanks sir..ap sab Kuch practically samjhate hoo. Jo koi aur RUclipsrs Nahi batatae

  • @RajUp-l1c
    @RajUp-l1c 11 месяцев назад

    Thank you thank you you just cleared my doubt since 4 years

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 года назад +2

    Excellent video sir. All of ur videos r different from the rest of the RUclips videos done by other people. Although there r tons of videos on finding out CL of column, but ur videos r always on the edge.
    Thnx

    • @EverythingCivil
      @EverythingCivil  4 года назад +1

      Thank u so much Sarthak.
      This really means a lot.
      Keep supporting ❤️

  • @yasirzhari2523
    @yasirzhari2523 4 года назад

    Best channel for civil engineers

  • @pradeepkumaryadav3859
    @pradeepkumaryadav3859 4 года назад +1

    Great sir Crystal clear explanation sir.
    Learning can be there in 4 to 5 minutes video as others do , but urs is excellent sir , complete details u hv given sir
    Thanks u so much .
    Abhi aap shuttering pe video laye sir making se lekr checking takkk

  • @HammadSherwani-q5n
    @HammadSherwani-q5n Год назад

    Perfectly explained❤

  • @rayansawant8288
    @rayansawant8288 4 года назад

    Very usefull video for Civil Engineers!!!!

  • @pavush326
    @pavush326 4 года назад +1

    One of the top quality ...video with superb detailing ...🙏

  • @NileshKumar-rv3bk
    @NileshKumar-rv3bk 2 года назад +4

    51d = 51*16= 816 mm hoga . Par apne 306 liya h. In case Mera development length Ld middle portion se jayad ho jayega to kya karenge . Jaise Floor height 3 m h Mera dia of bar 20 mm h aur Ld = 51*20 = 1020 mm then Mera overlapping support side me chala jayega . Is case me kya karenge

  • @avdheshbhatt2290
    @avdheshbhatt2290 2 года назад

    very very helpfull video sir

  • @dulhapur
    @dulhapur 3 года назад +1

    For finding A zone and B zone in coloumn only two floor beams are considered,is not lintel tie beam required to be considered?

  • @khushalharne5232
    @khushalharne5232 4 года назад

    First view Bhai 👌👌
    Nice Information

    • @EverythingCivil
      @EverythingCivil  4 года назад +2

      Thanks brother..keep supporting ❤️
      U people are everything for me.

  • @TOP10-z5k8s
    @TOP10-z5k8s Год назад

    Bro slab to slab distance ya beam k depth minus Krna hai ??

  • @raviraj96k74
    @raviraj96k74 2 года назад +3

    51 d for 16mm bar =816

  • @homeplan3532
    @homeplan3532 2 года назад

    Sir mere column ke sariye plinth beem se 3.6 & 4feet height hai to mujhe ab lapping ke liye ab sariye ke cutting height rakhni chahiye

  • @anuragkhati4547
    @anuragkhati4547 4 года назад

    Sir 12mt steel ko provide kr saktey hai ek hi length m pura ??

    • @EverythingCivil
      @EverythingCivil  4 года назад

      Haan agar apki puri cutting length lap wagera mila ke 12m ke andar arahi hai to kar sakte ho aap.

    • @anuragkhati4547
      @anuragkhati4547 4 года назад

      Thnx

  • @AjitSk21
    @AjitSk21 Год назад

    We have taken Tue beam at bout 5ft from footing and pn above of tie beam we have taken plinth bem of 5ft ...
    But due to improper planing at start we are getting lap joint between Tie bem and plinth beam .. is that allowed??

  • @nileshsonawane324
    @nileshsonawane324 4 года назад

    Shayad aap ki hi talash thi...bhai pls ek layout par details main ek video banao pls...

  • @deepakraja42
    @deepakraja42 Год назад

    Sir I had took 6 ft below ground for footing and 4,5,6 ft steel above the ground . Now I overlapped the steel on ground floor and also given joggle.
    Sir mujhe g+4 banana hain kyonki maine ground floor pe lapping diya hain toh isse farak toh nai padega na. My all pillar size is 9*18 . Baaki main aur strong karne ke liye lapping ko welding Kara du kya. Pls answer sir

  • @modassariqbal306
    @modassariqbal306 4 года назад

    Sir agr hamra Design mix me OPC 53 cement use kiya gya but kya me PPC cement used kr sakta hu column concrete k liye OPC 53 ki jagej p....kya strength p column k kuch farak parta hai kya

    • @EverythingCivil
      @EverythingCivil  4 года назад +1

      Nahi bilkul nahi. PPC cement me pozzolona material mix hota hai to uski strength OPC 53 se kam ayegi aur agar cement ki strength kam ayi to concrete ki bhi kam ayegi..agar ap chaho to design mix me flyash add kar sakte ho usse cement ka consumption kam ho jayega.
      PPC use karne se pehle uski strength check karo kitni aarahi hai agar opc53 jitni hai to it's ok..lekin yaad rakhna initial strength 70% bohot late ati hai PPC ki.

  • @nadeemsaiyed2186
    @nadeemsaiyed2186 2 года назад

    Is 7 mt bar cutting length is allowable. As per rule it should be 4 mt only?

  • @anuragkhati4547
    @anuragkhati4547 4 года назад

    Sir BBS site par hi calculate krna pdta hai kya ??

    • @EverythingCivil
      @EverythingCivil  4 года назад

      Haa VFC drawing ane ke bad banta hai kaam shuru karne se pehle. Fitter ko cutting length dena padta hai cutting bending ke liye.

    • @anuragkhati4547
      @anuragkhati4547 4 года назад

      Bada project ho to usme kaise site p ho paeyga itni calculation ??

    • @EverythingCivil
      @EverythingCivil  4 года назад

      Badi site hogi to unka ek alag dept hoga billing ya QS with special staff who are experienced in this. Usually contractor is responsible for making the BBbs and client certifies it.

    • @anuragkhati4547
      @anuragkhati4547 4 года назад

      Ohk thanx a lot sir

  • @vivekborse2790
    @vivekborse2790 3 года назад +3

    51 x 16=816 mm

  • @aryaman4068
    @aryaman4068 Год назад +1

    Bend deduction????
    One 90⁰ bend
    -2d?????

  • @deoraobankar8259
    @deoraobankar8259 8 месяцев назад

    Thanks i understand.

  • @modassariqbal306
    @modassariqbal306 4 года назад

    Thnku so much sir!!

  • @amitkumarsah9435
    @amitkumarsah9435 3 года назад

    isnt that bent up portion is called staggered portion or staggered and lapped portion mean the same?

    • @EverythingCivil
      @EverythingCivil  3 года назад

      Yes but staggered lapping means not all the lap should come at same levels.

  • @hanumanthubellam6691
    @hanumanthubellam6691 Год назад

    How to take lap points

  • @armyofficermanishsharma5039
    @armyofficermanishsharma5039 4 года назад

    Happy Engineers day brother

  • @souravbhandari7348
    @souravbhandari7348 3 года назад

    please make a video on multiple beams bbs

  • @AshishKumar-mv8dm
    @AshishKumar-mv8dm 9 месяцев назад

    51d= 51x16= 816mm how did you consider 306mm

  • @ron4928
    @ron4928 4 года назад

    So there are 5 staggered and 5 non staggered bar in column

  • @sarojchhotray8287
    @sarojchhotray8287 Год назад +1

    51*16=306???

  • @themimic-chetanubale1603
    @themimic-chetanubale1603 Год назад

    Slab thickness kyo nahi pakada

  • @MrRana1995
    @MrRana1995 Год назад

    o.306 kaise agya jab stageered apka 806 hai to

  • @Kumar-kf3cg
    @Kumar-kf3cg 3 года назад

    Pleased provide bridge pile bbs

  • @ankursinghsingh729
    @ankursinghsingh729 6 месяцев назад

    Bhai aapne Ldt ka calculation galat kiya hai 51x16= 816mm aayega na ki 306

  • @faizmalik3187
    @faizmalik3187 2 года назад

    Gokani consultant I m also working on gokani r. C. C. Drawing

  • @pranayalte4193
    @pranayalte4193 3 года назад

    51d= 16×51=816 then how you got 306?

    • @EverythingCivil
      @EverythingCivil  3 года назад +2

      It was calculation error. Hope u understand. 😁

  • @soumenghosh6743
    @soumenghosh6743 4 года назад +3

    306 nehi 816 hoga

    • @EverythingCivil
      @EverythingCivil  4 года назад

      At what time stamp?

    • @soumenghosh6743
      @soumenghosh6743 4 года назад

      51*16=816 mm

    • @soumenghosh6743
      @soumenghosh6743 4 года назад

      @@EverythingCivil 51*16=816 mm

    • @EverythingCivil
      @EverythingCivil  4 года назад

      Yes error hogaya waha..but imp ye hai ke waha lap length lena hai...jo har kisi project me alag hota hai thoda thoda.

  • @shabeebali9742
    @shabeebali9742 3 года назад

    Can you send the PDF file

  • @ROXY-zm6dd
    @ROXY-zm6dd Год назад

    L bar ka length consider karna bhool gaye aap😊

  • @shabeebali9742
    @shabeebali9742 3 года назад +1

    Ld is incorrect , 51d , 51*16 =816mm= 81 cm

  • @mdfaiyazmiyan7959
    @mdfaiyazmiyan7959 2 года назад

    Overlapping 51×d, 51×16=816 hota hai.
    App ne bola 306 kaise hota hai

    • @EverythingCivil
      @EverythingCivil  2 года назад

      I was calculating live. It was a calculation error. Please understand the concept.

  • @dulhapur
    @dulhapur 3 года назад

    Clear Height between plinth beam top and roof beam bottom-11 feets
    Zone-A-11/4=33 inches
    Zone-B-11*12-66=132 -66=66 inches
    There are 6 bars 16mm@4,12mm@2
    At zone B top- 2 no of lappings
    At zone B middle(30 inch below top lapping points)-3 no of lapping
    At Zone B bottom (30 inch below middle lap point)-1 lapping
    Whether the above arrangement is allowble?
    Whether lintel tie beam can be provided any zone?
    What if lintel tie beam falls on zone-A top area?

  • @onlymemes7842
    @onlymemes7842 2 года назад

    lap legth galat li he

  • @jitendraalshi6075
    @jitendraalshi6075 Год назад

    U made calculation wrong I.e. 51 x d(16)= 816mm but you consider it as 316mm .

  • @ashwins1485
    @ashwins1485 2 года назад

    51*16=816

  • @dilipdebnath4929
    @dilipdebnath4929 2 года назад

    51d=51x16=816m=0.816 mt .I think this is the correct calculation .you have shown this as 306 mm=0.306 mt. This totaly wrong.

  • @Kingcobra-t1s
    @Kingcobra-t1s Год назад

    51d is not 306

  • @pranavnaxane2252
    @pranavnaxane2252 Год назад

    Wrong:-Check development length. 51*16=816mm.

  • @cricketreview9037
    @cricketreview9037 Год назад

    Only 2 zone

  • @balkrushnapatil2242
    @balkrushnapatil2242 Год назад

    51×16=816 hota hai 306 nahi

  • @naushadalam7201
    @naushadalam7201 2 года назад

    Explain is not properly,

  • @raviyadav7223
    @raviyadav7223 2 года назад

    Sir isme jo 51d bola hai uska calculation 306 kaise hai 51×16= 816

  • @snehasispatra8443
    @snehasispatra8443 6 месяцев назад

    51x16 = 306 mm ???😂

  • @indian2881
    @indian2881 Год назад

    Bakwass apne ko hi smja ra

  • @vishalmhaske604
    @vishalmhaske604 2 года назад

    Kya bakwas padate ho bhai 😐