Lemon Air Conditioners are a REAL Thing... Here's Why!

Поделиться
HTML-код
  • Опубликовано: 29 окт 2024

Комментарии • 40

  • @dgapp76
    @dgapp76 2 месяца назад +4

    Have a guy in my neighborhood with a 2 year old Carrier system that I ended up replacing the compressor, contactor, capacitor, txv in air handler and blower motor in the air handler all in a matter of 3 months. Our neighborhood doesn't have brown outs or any power supply issues. All warranty work. Definitely qualifies for a lemon award.

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад

      Interesting. Definitely sounds like a power issue of some kind. Possible a surge?

  • @Trinity-rc6ch
    @Trinity-rc6ch 2 месяца назад +5

    I had a situation with my HVAC and the evaporator coil was replaced. The technician while pulling the line to connect caused a kink in the line. Then my wall had to be opened up and then the unit would not run, short story is it was technician failure along with their own equipment failure too! I get they are working in crazy heat and might not be as focus as they should be, but that is part of the job. Come prepare to deal with the heat. Just fix my AC!

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад +2

      Ouch. Sounds like they were at least willing to make it right after making the mistake. Sorry that happened!

    • @Trinity-rc6ch
      @Trinity-rc6ch 2 месяца назад +1

      @@NewHVACGuide they did, only because I gave them a notice of liability.

  • @elgringoec
    @elgringoec 2 месяца назад +2

    I've heard of manufacturing defects but mistakes in installation like that - brazing residue, moisture induced oil acidity, faulty connections, rough handling, bad locations, ductwork and or lineset too small, lineset in compromised routing, etc etc... That's going to be the dominant cause of problems.

  • @mattnear9114
    @mattnear9114 2 месяца назад +1

    As an hvac technician myself i have used dye many time but i know alot of people who really don't like it. For me dye is another way to find leaks and sometimes i wish it would just be put in on install so the leak search process would be faster. Dye isnt a silver bullet though, i still find leaks with my leak detector that did not show up with dye. Dye travels with oil, so if only refrigerant leaks out and no oil, dye won't work just like a leak detector won't work every time. For me leaks can be difficult to find and I recommend using multiple methods. Good luck out there, some leaks are very tricky.

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад +1

      Good points. I think we all have some doozies to tell when it comes to refrigerant leaks

  • @Allen-c3x
    @Allen-c3x 2 месяца назад

    I had a problem with the coil dripping water onto the air filter constantly. Their solution was to buy a kit which was simply a piece of metal that diverted the water to the tray. This was after the coil was replaced once. Ten years of putting up with this was enough for me. Replaced the system.

  • @miltonsaucedo2223
    @miltonsaucedo2223 2 месяца назад +1

    thank you for all your videos. can i bother you with a question? Would a 4-way cassette (properly sized, maybe 16,000btu) placed in a hall (right in the middle where 3 bedroom doors meet) be able to cool down 3 adjacent 110sqft bed rooms? or do you always have to put an air handler in every bedroom??

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад +1

      I’ve seen that before. You’ll have to keep doors open though

  • @jackl9922
    @jackl9922 2 месяца назад

    I had a York system (gas/AC) with continuous failures on the heating system. Had all replaced including the AC. After 5 yrs, only maintenance (I do) and no repairs. I go with modulating systems that are more risky for repair needs, but like the balanced comfort. I think the York gas furnace was a true lemon. Pressure switches, inducer motor, two blower motors. Gave up when suspected secondary heat exchanger.

  • @FrostHVAC
    @FrostHVAC 2 месяца назад

    Only time I had a real lemon of a unit was a TXV. First one came from the factory stuck shut. The replacement one was stuck shut, the third one was stuck shut with a new lineset. Swapped the unit and it ran fine…. It was crazy, ive also had bad boards from carrier. Two boards were given to me shorted out, third one went in fine. Crazy tbh

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад +1

      They have an issue every now and then. Some have more though 🙂

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад

      Join us on Tuesday for our live show!
      www.youtube.com/@hvacguideliveshow

  • @shivram21
    @shivram21 2 месяца назад

    What about lennox leaky coils?

  • @lynncomstock1255
    @lynncomstock1255 2 месяца назад +2

    Lemons are created in the field. You missed the biggest errors that plague even packaged units.
    #1 is oversized equipment.
    # 2 is lousy ductwork. which is incorrectly designed and installed
    # 3 is undersized ductwork. # 4 is dirty indoor coils (installers and homeowners share the blame.)

  • @antoinettebolduc997
    @antoinettebolduc997 2 месяца назад +2

    Currently having g this issue. New system in September and they have been out countless times. Now saying they will charge me even if under warranty. First ac and then heat and now back to ac. So tired of it.

    • @Trinity-rc6ch
      @Trinity-rc6ch 2 месяца назад +2

      @@antoinettebolduc997 have them honor the warranty. Make sure you know what parts are under warranty and the time frame for each. For example, the condenser has longer warranty than other parts. This way, they can’t bamboozle you on it. And these AC companies have liability when they break something. Keep good records in case you need to send them a notice of liability.

    • @lynncomstock1255
      @lynncomstock1255 2 месяца назад

      #1 Was it a replacement system on old ductwork and why was the old system replaced?
      # 3 Or was it whole new system (Ductwork and equipment?

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад

      Wow. What’s have they been repairing?

    • @antoinettebolduc997
      @antoinettebolduc997 2 месяца назад

      @@lynncomstock1255 I had a system for 13 years. I asked for the same. It isn’t the same.

    • @antoinettebolduc997
      @antoinettebolduc997 2 месяца назад

      @@NewHVACGuide I have had issues with the dehumidification and then it leaked several times. The it would t stop running wouldn’t cycle out. Then the thermostat was going crazy. There’s a musty smells d I believe that it’s from when I called about it leaking g, the tech came out with no wet vac and it sat in water all night till he came the next day. Then I had to dry out where the filter goes and replace it myself. Then it leaked again. Recently it is barely flowing g out of the vents.

  • @michaelhayden5023
    @michaelhayden5023 2 месяца назад

    Can WE get a definitive answer on DYE in the System? DOES it Clog or damage in any way?

  • @mylesprior4985
    @mylesprior4985 2 месяца назад

    Seems like since Covid a large amount of these? Had 2 different units fail months later!

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад

      Ouch! Maybe get a different installer?

    • @NewHVACGuide
      @NewHVACGuide  2 месяца назад

      Join us on Tuesday for our live show!
      www.youtube.com/@hvacguideliveshow

  • @PHamster
    @PHamster 2 месяца назад

    My lemon: Carrier 25HHA.

  • @johnlangley6449
    @johnlangley6449 2 месяца назад

    I agree the install is key to many problems I see guys hurry up untrained don’t give a damn 😢