Fuseboard Upgrade Plus Testing - Electricial Installation

Поделиться
HTML-код
  • Опубликовано: 21 сен 2024
  • Thanks for watching, if your enjoying our content as much as were enjoying making it then please consider subscribing to the channel and smash the bell icon so you dont miss future uploads.
    Check Out Rs Electrical Supplies:
    Http://Www.rselectrica...
    Join this channel to get access to perks:
    / @jrcelectrical

Комментарии • 59

  • @gary.corcoran
    @gary.corcoran 4 месяца назад +1

    Nice One Jack. I explained 'the ring circuit' to my Australian apprentices several years ago. They looked at me in disbelief . . .

    • @JRCElectrical
      @JRCElectrical  4 месяца назад

      I think we’re he only country doing it now 😂

  • @user-vp7oj2rv2l
    @user-vp7oj2rv2l 4 месяца назад +4

    R1r2 readings should always be done with the earth cable taken out of earth bar because of parallel paths will give you false readings 👍

    • @JRCElectrical
      @JRCElectrical  4 месяца назад

      I don’t think it does, as your just testing to the live of that circuit, I could be wrong tho I no if you take ze you have to have earth disconnected to reduce parallel paths

    • @user-vp7oj2rv2l
      @user-vp7oj2rv2l 4 месяца назад +2

      @@JRCElectrical you definitely should take the earth out the earth bar and connect to the live to prove continuity, you will get false readings from all the other circuits and bonding conductors
      Top video by the way 👍

    • @JRCElectrical
      @JRCElectrical  4 месяца назад

      @@user-vp7oj2rv2l fair I shall look into this, cheers dude

    • @garylatto4191
      @garylatto4191 4 месяца назад +2

      Main electrical did a vid about it last week ish , and showed a circuit which gave a perfectly good r1 r2 with connected then disconnected and found to be a broken cpc, was picking up the r2 from boiler due to bonding

    • @aryanelectrical
      @aryanelectrical 4 месяца назад

      Yes but your only removing a parallel path before the final circuit. The removal of cpc at final will minimise risk of detecting a suitable parallel path at end of final giving a false security you have r1 + r2 Jack ​@@JRCElectrical

  • @deeharris1908
    @deeharris1908 4 месяца назад +1

    Nice easy 1 for ya m8 ,noice job c ya nxt time young lad

  • @GaryB1980
    @GaryB1980 4 месяца назад +1

    Love a good board change video.

  • @garylatto4191
    @garylatto4191 4 месяца назад +1

    Big up ya jack, yeah some more testing vids with explanations to not getting the results ud expect 👌

  • @andycriddle7316
    @andycriddle7316 4 месяца назад +1

    Top work Jack, big up yourself!! 🔥🔥👏🏼👏🏼👏🏼🤙🏻🤙🏻🤙🏻

  • @Palmit_
    @Palmit_ 4 месяца назад +3

    a quick eyh up.. this is shed building season.. i know you've covered the work and what not. feel free to do another resfresher on outside electits, especially the law aspect. what the consumer/tenant can legally do, but also what they shouldn't do if they are stupid enought to try// advise them on safety and rumours.. i.e: "if i wear rubber shoes, i'm safe from holding mains live as volts isn't reaching ground" - "ok.. but dont trip over, or touch anything, at all. not even the thing you're connecting to." i mean, dispel the myths/crud and and kinda stuff. please. :)

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      This is a good shout, I defo won’t be testing the rubber shoes tho 😂😂 cheers

  • @alandobson5532
    @alandobson5532 3 месяца назад +1

    Hi just a quick question can you run a new TV off the lighting cct if so does it need a fixed fuse spur at 3 amps 👍love your videos

    • @JRCElectrical
      @JRCElectrical  3 месяца назад +1

      I would say so if marked up properly so that nothing else will be plugged in

    • @alandobson5532
      @alandobson5532 3 месяца назад

      Does it need a fixed fuse spur or just direct from the lighting feed it's for a flat screen TV with bad access.. Sorry to pester you.. 🙄

  • @martinburgess2322
    @martinburgess2322 4 месяца назад +1

    Nice little board 👌👊⚡

  • @Phil_AKA_ThundyUK
    @Phil_AKA_ThundyUK 4 месяца назад +1

    The On/Off on those old meters freak me out every time. You turn it off, take the cover off, and then it looks like it's on again. Did it with my old Wylex when I was swapping it out.

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      Hahaha yeah it’s just the red on off and it moves around
      I also think the same every time 😂😂😂

  • @AaronMall33
    @AaronMall33 4 месяца назад +1

    Big up

  • @three-phase562
    @three-phase562 4 месяца назад +2

    Interesting, does the BG SPD not need an MCB then? Makes it a bit easier for retrofitting if it doesn't.

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +2

      Yeah makes it a lot easier, doesn’t need mcb anymore I did up until recently but they changed it to single mod from the mains

    • @rayc1503
      @rayc1503 4 месяца назад

      ​@JRCElectrical I haven't fit a bg board for ages. Still good to know they've got rid of the mcb aspect of it. How did you find out? Have the mi's been amended?
      Great stuff Jk 👊.

  • @declanbuck6536
    @declanbuck6536 4 месяца назад +1

    Big up yourself jack ❤

  • @pikricky
    @pikricky 4 месяца назад +1

    Noice one Jack,good easy to follow tutorial there,have you ever fitted the Drayton Wiser thermostat for heating only,I want to replace my Siemens RDJ10RF system with it so I can control it with my phone from anywhere, if you ever fit one video it for me please ,big up big pal

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      I’ve done a video on the tado rickiano you could check them out, got it on my house and it’s ace

    • @pikricky
      @pikricky 4 месяца назад +1

      @@JRCElectrical Cheers,I will have a look,thank you Jack

    • @JRCElectrical
      @JRCElectrical  4 месяца назад

      @@pikricky any time sir

  • @Cablesmith
    @Cablesmith 4 месяца назад +1

    Good video big dawg

  • @Phil_AKA_ThundyUK
    @Phil_AKA_ThundyUK 4 месяца назад +1

    Red and black radials - that['s unusual isn't it? :)

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      Not if just one socket was added at the time, never really thought about that tho to be fair and I suppose your right, boiler circuits are nearly always a radial but not really sockets on red and black thinking about it

  • @mikeevans1355
    @mikeevans1355 4 месяца назад +1

    Notice 👌🏻

  • @Waynesworldofgaming
    @Waynesworldofgaming 4 месяца назад +1

    Big jack 🙌🏻

  • @cranefamily
    @cranefamily 4 месяца назад +1

    Hi Jack did I miss the tail change ?

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      👀

    • @cranefamily
      @cranefamily 4 месяца назад +1

      😂just wanting someone to train me

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      @@cranefamily 😂😂😂 u won’t see that part on RUclips, dno have to change them and fit an isolator if there’s not one 👀

    • @cranefamily
      @cranefamily 4 месяца назад +1

      @@JRCElectrical O I See😜

  • @mark_just_mark
    @mark_just_mark 4 месяца назад +1

    Something I want to know...what was the beep!!! 🤣🤣🤣

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      Unsure but it was coming from the camera gimbal 🤷‍♂️ 😂😂😂

  • @stokiesparky2790
    @stokiesparky2790 4 месяца назад +1

    Minta

    • @JRCElectrical
      @JRCElectrical  4 месяца назад +1

      ❤️ my bro

    • @stokiesparky2790
      @stokiesparky2790 4 месяца назад +1

      @@JRCElectrical having a little run on the treadmill so I’ll thought I’ll pass the time with a bit of JRC 🤙

    • @JRCElectrical
      @JRCElectrical  4 месяца назад

      @@stokiesparky2790 the best time for it untill u get an awkward boner 😂

    • @stokiesparky2790
      @stokiesparky2790 4 месяца назад

      @@JRCElectrical 😂😂😂😂
      I was very sweaty and Topless too 😂

    • @rayc1503
      @rayc1503 4 месяца назад +1

      ​@stokiesparky2790 Tmi, right on that note I'm off to puke over some old granny 😂.