I just wanted to say THANKS!! I have watched so many of your instructional videos and literally play and pause to do the same tasks you are doing. So far you helped me with the remote DS injector, the DIY propotioner and now this K1 unloader setup - you are awesome, thanks! I owe you a ginger ale if we ever meet :)
Mike, thanks for the kind comment. Comments like yours makes everything worth while! Helping people out to be more efficient and giving back. I would love a ginger ale if we ever meet up. Thanks Brother!
Great video question I want to change my unloader to a Gp K7 to take away the kick when the trigger is engaged, I am running a Honda GX 690 3000psi pressure washer. At idle what I should see on my gauge? and what should I see when the trigger is in gauged thanks
Great video! I have a question for you. I noticed you have a drip coming from unloader. When I installed my k1, I bought specialty bsp to npt adapters just to make me feel better about threading everything together. My unloader works great and I love it but from day one it has leaked where the unloader goes into the block and I can’t get any answers whether this is ok or whether it needs to be addressed and how. I used blue monster tape and a little bit of tru blue over threads which has never leaked on me before. Any feedback would be greatly appreciated!
Our unloader on the big machine leaks as well. I have not noticed any difference in performance from the machine. We used tru blue sealant, but it still leaks. Since it is just water, we have not tried to stop the leak since it so small. I hope this helps. Thanks
Great video, I’m wanting to put these k1’s on my 4 and 8 gallon machines. Did you have to mount the unloaded that way? Could you have attached it to the machine the way the original unloaded was mounted? I didn’t catch as to way to bolted it to the frame. Thanks
I installed the K7.1 unloader and adjusted accordingly and everything is working properly. When I idol down the machine I am getting a hard surge on the bypass line, when I idol back up it goes away. What can be done to fix this issue? Thanks
Question: On the unloader bypass hose line. You mentioned that you changed it to 1/2" hose. Is that the size of the inside diameter (I.D.) or the outside diameter (O.D.) of the hose? Does it make a big difference?
It has been working great. I thought the same thing about my 4 GPM when I first got it. It will not be long before you want to upgrade to more flow. Thanks
I'm about to put the zk1 on my 8.5gpm 3500psi pump. The guy at the local pressure washer store says sometimes they have issues with running long lengths of hose (300' on my reel), extension pole, and downstreaming. I was wondering if you ever run into it acting weird at any time. Can you use your ball valve for rinsing ok. Just wondering if there is anything i need to watch for or behavior i might need to change. I hate the thought of getting on a job and finding out the hard way. Thanks.
@@bananacakes8939 Agreed! I have not any problems forcing the threads. Not saying it is the correct way, but that what I learned when installing mine. Thanks
I perfer the soft touch unloader instead of the pressure unloaders. The benefit for me is not having a blast of pressure when you pull the trigger. Thanks
@@MikeWho_MikeJones I understand what a bypass and chemical bypass is. At 12:15 is what I’m talking about. Why are you checking for a trickle of water from the bypass line?
@@allproexteriorservicesllc5338 what is the correct orifice for adjusting that unloaded, I’m thinking of doing the switch out myself? Also can that zk1 go on a 5.5 ?
@@joeplume8048 Yes, the ZK1 can be used on a 5.5 GPM unit. Just make sure you get the one that meets the GPM. You should used any color spray tip for a 5.5 unit. Thanks
I just wanted to say THANKS!! I have watched so many of your instructional videos and literally play and pause to do the same tasks you are doing. So far you helped me with the remote DS injector, the DIY propotioner and now this K1 unloader setup - you are awesome, thanks! I owe you a ginger ale if we ever meet :)
Mike, thanks for the kind comment. Comments like yours makes everything worth while! Helping people out to be more efficient and giving back. I would love a ginger ale if we ever meet up. Thanks Brother!
@@allproexteriorservicesllc5338
Got it.
Thank you 😊 👍
The way it gently releases is so satisfying!
Agreed!! Thanks
@@allproexteriorservicesllc5338 Are you upgrading your GPM?
thank you! the best video i've found on setting up by far!
Thanks!
Just used this video today to swap out my Unloader ! Thank you !!
Glad it helped. Thanks
Great video question I want to change my unloader to a Gp K7 to take away the kick when the trigger is engaged, I am running a Honda GX 690 3000psi pressure washer. At idle what I should see on my gauge? and what should I see when the trigger is in gauged thanks
Thanks! On the trigger, you should see close to what the pump is rated for. I do not remember the pressure when off the trigger.
Great video! I have a question for you. I noticed you have a drip coming from unloader. When I installed my k1, I bought specialty bsp to npt adapters just to make me feel better about threading everything together. My unloader works great and I love it but from day one it has leaked where the unloader goes into the block and I can’t get any answers whether this is ok or whether it needs to be addressed and how. I used blue monster tape and a little bit of tru blue over threads which has never leaked on me before. Any feedback would be greatly appreciated!
Our unloader on the big machine leaks as well. I have not noticed any difference in performance from the machine. We used tru blue sealant, but it still leaks. Since it is just water, we have not tried to stop the leak since it so small. I hope this helps. Thanks
Good to know it hasn’t caused you problems. You probably run your machines harder than I do so that makes me feel better. Thanks for the feed back!
Great video, I’m wanting to put these k1’s on my 4 and 8 gallon machines. Did you have to mount the unloaded that way? Could you have attached it to the machine the way the original unloaded was mounted? I didn’t catch as to way to bolted it to the frame. Thanks
I wanted to mount the unloader off the pump to keep the additional weight off the pump. You could mount it to the pump if you have to. Thanks
Great video brother, at a great time. I’m about to install my K7. Question: When your machine is off, what does the gauge read? It should be at zero.
Thanks!! The gauge reads zero when off.
@@allproexteriorservicesllc5338
Why zero when you're not pulling trigger?
Just trying to understand.
Thank you
@@brushbristlepressurewashin4258 Because it is not under pressure off the trigger. It sense flow and then builds pressure. Thanks
The Fresh Rinse has got to be the coolest name I've come across..
@@jamescarter-ze5hm Thank you. All credit goes to Joe Deery
Great video! Thanks for posting!
Thanks for the videos
Are you using this as a softwash as well if so are you batch mixing
Not anymore. When we did use it, we had it connected to the SH tank and down streamed. Thanks
Did you make the mount that the machine is sitting on? If not where'd you get it?
I made the mounting stands for the pressure washers. Thanks
What fitting did you use for the bypass? I can't find anything to fit mine
1/2" NPT to 1/2" barb. Thanks
Question brother why did u change ur unloaded?
And was this unloaded bigger (more flow) ?
I changed from. Pressure trap unloader to a flow sensitive unloader. Thanks
I installed the K7.1 unloader and adjusted accordingly and everything is working properly. When I idol down the machine I am getting a hard surge on the bypass line, when I idol back up it goes away. What can be done to fix this issue? Thanks
It may be due to the low RPM not providing the power to send the water through. I have not had this happen. Thanks
I appreciate the response and all of the content you share with the Wash community.
What pressure was you trying to get to in the video? Do you max the pressure out of the unloader or set it to a certain pressure?
You want about a 5% of bypass when on the trigger. Thanks
Question: On the unloader bypass hose line.
You mentioned that you changed it to 1/2" hose. Is that the size of the inside diameter (I.D.) or the outside diameter (O.D.) of the hose?
Does it make a big difference?
1/2" ID. The reason I use 1/2" is because the unloader has the 1/2" bypass instead of 3/8". Thanks
Has this setup worked good for you? I just got a 4gpm and want it to last as for as long as it can.
It has been working great. I thought the same thing about my 4 GPM when I first got it. It will not be long before you want to upgrade to more flow. Thanks
I'm about to put the zk1 on my 8.5gpm 3500psi pump.
The guy at the local pressure washer store says sometimes they have issues with running long lengths of hose (300' on my reel), extension pole, and downstreaming.
I was wondering if you ever run into it acting weird at any time. Can you use your ball valve for rinsing ok.
Just wondering if there is anything i need to watch for or behavior i might need to change.
I hate the thought of getting on a job and finding out the hard way.
Thanks.
I have not ran into any problems to date. i also use my ball valve for rinsing all the time. But, I also only run 200' of hose. Thanks
how did you solve the British thread problem Where did you get the reducers
I just forced it and applied True Blue and have not had any problems. Thanks
@@allproexteriorservicesllc5338
what is paid 180 bucks for this unloader . British threads are British threads I live in South Carolina I **** hate this ****
last resort tell me more I wanna hear it?
@@bananacakes8939 Agreed! I have not any problems forcing the threads. Not saying it is the correct way, but that what I learned when installing mine. Thanks
Why did you picked the ZK1 instead of the K7 unloaded for this pressure washer? Thanks in advance!!
I heard the K7 was finicky and a few people recommended the ZK1. Thanks
@@allproexteriorservicesllc5338 thanks a lot !!
Where you put your chemical injectior
We put the injector close the reel. Thanks
@@allproexteriorservicesllc5338 why won't mine pull from the hose reel
Unloaded valve. Dont have kick back on the gun. When you hit the trigger . What's it call .where and the cost. And your feed back on it. Thanks
It is a flow unloader and available at Southside Eq. I have the GP ZK1. Thanks
Hey where did you have your shirts made? They look great. Thanks
I had a local shirt company make them for me. It has been an experiment and they may offer them soon. Thanks
It SAAAAAYS 3600 psi... can it handle 4k???
Not sure about 4K, but that is a lot of pressure. Thanks
I have the same machine what is the reason for this. Are there any benefits from this
I perfer the soft touch unloader instead of the pressure unloaders. The benefit for me is not having a blast of pressure when you pull the trigger. Thanks
@@allproexteriorservicesllc5338 couldn’t a soft touch unloaded come right off the pump? I don’t understand why the block was needed.
@@joeplume8048 Yes you can put it directly on the pump. The purpose of the block is to remove the weight & vibration from the pump. Thanks
Would you go from a 4gpm to a 8gpm or keep the 4gpm with a unloader upgrade or go 5.5 gpm with a limited budget. All with a gx390
I would go with the 5.5 gpm. A little more flow and still pulls a good percentage of SH. Thanks
Question…do I need to have water coming out of the bypass when I’m on the gun? What happens if I don’t have water coming out while I’m on the gun?
@@MikeWho_MikeJones I understand what a bypass and chemical bypass is. At 12:15 is what I’m talking about. Why are you checking for a trickle of water from the bypass line?
GP recommends a 3-5% trickle out of the bypass. I use this method instead of worrying about pressure. Plus what Mike Jones mentioned Thanks
Is it true these float unloaders have problems with down streaming?
I have not had any trouble with DS'ing. Thanks
🌴 very cool and safer. Now you can film with one hand without smacking your teeth out! 🌴
LOL!!! It will help! Thanks
Does the unloader bypass water as long as the engine is running or only when you get off the trigger?
Mainly when you are off the trigger. The bypass will direct the water back to the buffer tank. Thanks
@@allproexteriorservicesllc5338 Thanks!
where do you get that high pressure lines
Southside Equipment. Russ is great to deal with and is very helpful. Thanks
Can you run the wash down gun with this ?
I have seen people successfully running this gun with the ZK1 unloader. Not recommended for a pressure trap unloaded. Thanks
BIG question for you my man. That mounting block. I know you got it from Russ. Any idea what the part is called?
Just ask for the brass mounting block. They’ll know what you need
YOU GOT TO USE THE GREEN TIP TO AJUST THAT RIGHT!
It doesn't matter the color of the tip as long as the orifice is correct. The color only represents the spray pattern. Thanks
@@allproexteriorservicesllc5338 what is the correct orifice for adjusting that unloaded, I’m thinking of doing the switch out myself? Also can that zk1 go on a 5.5 ?
@@joeplume8048 Yes, the ZK1 can be used on a 5.5 GPM unit. Just make sure you get the one that meets the GPM. You should used any color spray tip for a 5.5 unit. Thanks