Every Gas Engineer Has Done This Repair ✅ (Full Guide)

Поделиться
HTML-код
  • Опубликовано: 4 окт 2024
  • Complete boiler repair walkthrough that applies to every combi boiler and also the mistake which got me wet 💦🫣
    #boilerrepair #combiboiler #vaillant #howto

Комментарии • 22

  • @shivavishnu8
    @shivavishnu8 2 месяца назад

    This guy is thorough & experienced. Been doing the same job for 20 years & he knows the correct way, no messing.

  • @mohammedbabu6959
    @mohammedbabu6959 3 месяца назад

    Explains all his work so well and precisely, it’s a joy to watch. Keep up the good honest work and probably the best plumber on RUclips..!

  • @chester6343
    @chester6343 4 месяца назад +3

    The fresh water will have been rotting the hell out of the system, hence why it's orange, the sensor is probably full of gunk.

  • @anthonygreenwood4486
    @anthonygreenwood4486 3 месяца назад

    After a year or two decided to get it fixed
    Wow

  • @macpatel7810
    @macpatel7810 4 месяца назад +1

    Good work. I was screaming take the pressure out of the pipes 1st 😂

  • @yasreh5845
    @yasreh5845 4 месяца назад

    Aslaamoalaikum.brother im sorry but i couldnt stop🤣🤣 this has happen to me countless time.jzk for sharing your knowledge it helps alot.

    • @PlumbingDoctors
      @PlumbingDoctors  4 месяца назад +1

      Wa alaikum as-salam wa rahmatullah - 😂😂

  • @maxnavsa4470
    @maxnavsa4470 4 месяца назад

    From looking at the brown water I'd say The system could do with flush.

  • @johnward5006
    @johnward5006 4 месяца назад +1

    My tip is never to leave the aav open after venting the pump, it's only there for commissioning!

    • @PlumbingDoctors
      @PlumbingDoctors  4 месяца назад

      👍🏽 good tip but on the flip side if customer drains heating system to carry out repairs the boiler may not vent all the air out

    • @johnward5006
      @johnward5006 4 месяца назад

      @@PlumbingDoctors As in anything, a little knowledge is a dangerous thing!
      I have no sympathy for ignorance in this day and age!!!!

    • @PlumbingDoctors
      @PlumbingDoctors  4 месяца назад +1

      @@johnward5006 you have lost me

    • @johnward5006
      @johnward5006 4 месяца назад

      @@PlumbingDoctors My point is, if the customer doesn't know how to properly refill a heating system, they deserve all they get!
      Not disconnecting the filling loop is another issue.

    • @mrserviceman8795
      @mrserviceman8795 4 месяца назад

      You also missed that the non return part of filling loop was on heating side when you replaced you fitted it correctly

  • @tahirmahmood6316
    @tahirmahmood6316 2 месяца назад

    Salaam, brother,, I am doing my gas Portfolio, I am 27 years old and looking for a gas engineer, I live in Birmingham, Rock,, can you help please, jzk

    • @PlumbingDoctors
      @PlumbingDoctors  2 месяца назад

      Wa alaikum as-salam, i get this message daily bro