- Видео 230
- Просмотров 1 477 515
Plumbing Doctors
Великобритания
Добавлен 21 сен 2007
💎 Who Are The Plumbing Doctors 💎
Waseem is the Owner/ Lead Engineer and Curtis is the Apprentice. Plumbing Doctors specialise in Domestic Plumbing, Heating & Gas Work. Waseem decided to focus on creating RUclips Videos during the first lockdown in 2020 as he wanted to share his knowledge in this industry to help anyone who wanted to learn during the hard times.
Domestic Plumbing And Heating Specialists
Located In Coventry, CV6, UK
www.plumbingdoctors.co.uk
Every Gas Engineer Has Done This Repair ✅ (Full Guide)
Complete boiler repair walkthrough that applies to every combi boiler and also the mistake which got me wet 💦🫣
#boilerrepair #combiboiler #vaillant #howto
#boilerrepair #combiboiler #vaillant #howto
Просмотров: 1 052
Видео
Flue Gas Analyser Comparison 2024 - Testo, Anton, Kane, TPI
Просмотров 40114 дней назад
In this video, we compare flue gas analysers to help you find the best flue gas analyser. We review popular brands including Testo, Kane, Anton, and TPI, and provide detailed information on various models. You'll learn about the costs of each analyser, features such as app compatibility, tightness tests, pressure tests, calibration costs, warranty lengths, purge durations, and other model-speci...
Let's talk about FGA’s 🧐
Просмотров 493Месяц назад
Time to say goodbye to expensive FGA calibrations! It's time for a change and I'm ready to save some money 💰 Let's talk about better options for flue gas analysers!
Plumbing & Heating Life 10 💥Worcester PCB, F75 & Cast Iron Soil Pipe
Просмотров 664Месяц назад
Plumbing & Heating Life 10 💥Worcester PCB, F75 & Cast Iron Soil Pipe
How to use Vaillant EcoTec boiler ✅🐰
Просмотров 3092 месяца назад
How to use Vaillant EcoTec boiler ✅🐰
Main Combi HE two lights flashing - Repaired ✅🪛
Просмотров 7624 месяца назад
Main Combi HE two lights flashing - Repaired ✅🪛
Vaillant turbo max - no hot water repair ✅
Просмотров 5005 месяцев назад
Vaillant turbo max - no hot water repair ✅
Plumbing & Heating Life 9 ♨️ Start of the full central heating installation
Просмотров 2,4 тыс.Год назад
Plumbing & Heating Life 9 ♨️ Start of the full central heating installation
Plumbing & Heating Life 8 - 🤯Have you seen an external prv on a worcester?!
Просмотров 1,1 тыс.Год назад
Plumbing & Heating Life 8 - 🤯Have you seen an external prv on a worcester?!
Plumbing & Heating Life 7 - 🟡 Gas Cert, Boiler Repairs & Custom Van Racking
Просмотров 1,6 тыс.Год назад
Plumbing & Heating Life 7 - 🟡 Gas Cert, Boiler Repairs & Custom Van Racking
IM BACK! 💥My New 2018 Ford Transit Custom Review - MORE TO COME
Просмотров 2,5 тыс.Год назад
IM BACK! 💥My New 2018 Ford Transit Custom Review - MORE TO COME
Plumbing & Heating Life #6 |🟢 Vaillant Ecotec Repair & Ariston 100L Cylinder
Просмотров 4,4 тыс.2 года назад
Plumbing & Heating Life #6 |🟢 Vaillant Ecotec Repair & Ariston 100L Cylinder
Plumbing & Heating Life #5 | Tap Strip Service & Combi Swap
Просмотров 2,6 тыс.2 года назад
Plumbing & Heating Life #5 | Tap Strip Service & Combi Swap
Combi Boiler Installation & System Flush | Full Tutorial 🔥
Просмотров 21 тыс.2 года назад
Combi Boiler Installation & System Flush | Full Tutorial 🔥
Plumbing & Heating Life #4 | Advanced Copper Bending (I F**kd Up) & Garden Tap Tricks
Просмотров 6 тыс.2 года назад
Plumbing & Heating Life #4 | Advanced Copper Bending (I F kd Up) & Garden Tap Tricks
Vaillant EcoFIT Pure Installation | Full Tutorial & Review 🟢
Просмотров 87 тыс.2 года назад
Vaillant EcoFIT Pure Installation | Full Tutorial & Review 🟢
Plumbing & Heating Life #3 | Greenstar Full Service & Monument Bender Review
Просмотров 5 тыс.2 года назад
Plumbing & Heating Life #3 | Greenstar Full Service & Monument Bender Review
Combi Boiler Install 🔥 | Cam On Head | Start 2 Finish
Просмотров 4,7 тыс.2 года назад
Combi Boiler Install 🔥 | Cam On Head | Start 2 Finish
Plumbing & Heating Life #2 | Eid Vlog & Italian Boiler Repair
Просмотров 2,9 тыс.2 года назад
Plumbing & Heating Life #2 | Eid Vlog & Italian Boiler Repair
Worcester 8000 Boiler | Complete Review | No Bullshit
Просмотров 27 тыс.3 года назад
Worcester 8000 Boiler | Complete Review | No Bullshit
Plumbing & Heating Life #1 | LIVE Water & BRAVE Boiler Repair
Просмотров 3,7 тыс.3 года назад
Plumbing & Heating Life #1 | LIVE Water & BRAVE Boiler Repair
Wire Y Plan System & 3 Port Valve Replacement
Просмотров 11 тыс.3 года назад
Wire Y Plan System & 3 Port Valve Replacement
Mira Shower Installation | Vs Triton T80Z | WHOS WINS?
Просмотров 32 тыс.3 года назад
Mira Shower Installation | Vs Triton T80Z | WHOS WINS?
Day In The Life Plumber | Gas & Heating | REAL LIFE
Просмотров 9 тыс.3 года назад
Day In The Life Plumber | Gas & Heating | REAL LIFE
How To Replace Kitchen Tap - Water Hammer Fix
Просмотров 4,3 тыс.3 года назад
How To Replace Kitchen Tap - Water Hammer Fix
Electric Water Heater Installation - Ariston Andris Lux
Просмотров 98 тыс.3 года назад
Electric Water Heater Installation - Ariston Andris Lux
Copper Pipe Bending Tutorial | *Multiple Bends*
Просмотров 43 тыс.3 года назад
Copper Pipe Bending Tutorial | *Multiple Bends*
Vaillant EcoTec Diverter Valve Replacement | FULL
Просмотров 81 тыс.3 года назад
Vaillant EcoTec Diverter Valve Replacement | FULL
Best Combi Boiler For Landlords | 2021
Просмотров 4,1 тыс.3 года назад
Best Combi Boiler For Landlords | 2021
How To Install A Washing Machine | Very Easy
Просмотров 1,7 тыс.3 года назад
How To Install A Washing Machine | Very Easy
Thank you so much. Hot water restored on daughter's birthday!
thanks for the video ! :D unfortunately my valves are not indicated by any way. I turned them the other way then they were , when I try to bleed it out, the water does not stop :D its coming out very slowly but continuously.
You should just turn off the cold wateer supply to boiler
From looking at the brown water I'd say The system could do with flush.
You know what’s poor about them, u fit one then the customer gets messages on the app from who owns them trying to take your future work, no other smart stat does that I don’t think, moved to Tado just for that reason.
Great tip thanks
nice and neat, thanks for sharing, great tips, i learnt a lot.
Glad you enjoyed it
No trap
This is not multitasking idiot
Thank you. This video helped to restore the pressure, however i find that I'm having to do this often, almost every week. Is it normal for a boiler to lose pressure so often?
No you have a leak in your system
@@PlumbingDoctors Thanks for letting me know. I haven't been able to identify the source of the leak, might have to call someone out.
best explanation ❤️
Glad it was helpful!
The fresh water will have been rotting the hell out of the system, hence why it's orange, the sensor is probably full of gunk.
Was that poop ? Or rust water
💩🤢🤮
My arse after last nights 2 pints of bovril
🫣😂
Full video on RUclips
Aslaamoalaikum.brother im sorry but i couldnt stop🤣🤣 this has happen to me countless time.jzk for sharing your knowledge it helps alot.
Wa alaikum as-salam wa rahmatullah - 😂😂
Good work. I was screaming take the pressure out of the pipes 1st 😂
😂 multitasking gone wrong
🤣@@PlumbingDoctors
My tip is never to leave the aav open after venting the pump, it's only there for commissioning!
👍🏽 good tip but on the flip side if customer drains heating system to carry out repairs the boiler may not vent all the air out
@@PlumbingDoctors As in anything, a little knowledge is a dangerous thing! I have no sympathy for ignorance in this day and age!!!!
@@johnward5006 you have lost me
@@PlumbingDoctors My point is, if the customer doesn't know how to properly refill a heating system, they deserve all they get! Not disconnecting the filling loop is another issue.
You also missed that the non return part of filling loop was on heating side when you replaced you fitted it correctly
Looks really good. Its called having pride in your work. I hope i can one day do lovely neat pipe work like you
This looks really good
Don't do a wham bam thank you mam job!!
Please put benny hill music to it 😂. Great video but feel a bit 🤮.
This has been a very informative video. I am a newbie 😂
This is an attention issue…
Can you do this in Portsmouth? Got one that needs fitting too
Too far for us
@@PlumbingDoctors That's all fine
Thank you!
You're welcome!
Flexi ....when you've got plenty of space for solvent
👍🏽
This video is a life saver. Had one of these boilers installed recently. I presume the pressure dropped because the radiators were bled. Thanks for your informative content.
👍🏽
If using the 24v RT do you just wire as a switch between the two 24v RT connections. Can it be better linked to the relative terminals on the CP4 obviously without 230v links????? You help me greatly appreciated.
Mirror should on top of the sink . Not on top of a toilet. this redesign was a total waste of money. after spending all this money. they didnt move the toilet to the center and sink to right. not sure if the plumber was drunk when he did this.
I used to work in social housing over 12000 properties 90% Worcesters. Dealt with their aftercare quite alot and I agree they're really good. They would come out the same day if not the next day. I never fit Worcesters because of all the leaks they have but the Worcester 1000 is by far the best budget boiler. Started fitting them instead of Main now.
Thank you….
Welcome!
Up to 10miles from Coventry. £350 inc vat. Drop us a message or call on 02477360101 📲👍🏽
Hi Waseem, just to say, great video and you've certainly done some research to put this together, but just wanted to correct you on a couple of things regarding the TPI DC710 and DC711. The DC710 actually has a 12 Year Warranty and you mention that it does pressure but doesn't have a timer. The DC710 doesn't have pressure, but you can either buy the DC710C2 Kit or the TPI SP620 (manometer) separately, and that will allow you to do pressure. In the View app, you can connect the SP620 while the DC710 is on the screen, so you can see the Flue Gas Readings and the Pressure readings from the DC710 and SP620 at the same time. In fact you can connect 2 of the SP620s to the app at the same time as the DC710 and that allows you to see and record the pressure at the appliance as well as the pressure at the meter and create a pdf report. Also with the SP620 manometer, you can time the Tightness Test in the app, and this will also create the same report as the flue gas reports. The View app also has some Job Management so you can put all the reports created with DC710, DC711 and Smart probes into one place as well as creating a Landlord/Homeowners Certificate form the readings taken for that property. The DC711 has a 6 Year Warranty, not 5 as you stated and both Models have a "skip" option which cuts the Purge Time down to a couple seconds so you don't even need to wait the full 30 seconds. Sorry for such a long comment but hopefully this helps both you and your viewers. If you need anymore information or clarification please do not hesitate to contact us, or Nigel, as you have his details already. We're always happy to help!! Keep up the good work.
Thanks for the feedback 👍🏽 I did some brief research and just shared the limited knowledge I had but really appreciate the comment 👍🏽👍🏽
Great explaining 👏👏👏👍
Glad you liked it
Brilliantly explained. Electric wiring bit confusing. I am d. I. Y. Man.
Glad you liked it!
Kane got the best service interm of annual calibration. Second day delivery
👍🏽
The Anton sprint pro 5 and 6 are £213 including vat for year 1, 2, 3 and 4. Year 5 is £278 (ex vat) or £333 including vat for year 5. Crazy when you think of it.
Wow 😮
I've been using Telegan fga's since 2000, currently have Evo 3. If I were choosing my first fga, I'd go for the TPI. If money was no object, the Testo. Had a Tpi digital thermometer for over 22years, still accurate. Have only had good experiences with Anton and gas detection is great. I'd advise anyone to spend plenty of time doing comparisons and consider your personal needs. Thanks for a great presentation.
I agree with everything you have said! 👍🏽👍🏽💯
Any thoughts on the EiUk fga? Heard good things about it.
I did not look in to them as I stuck with the main brands
Thank you so much! Your video was incredibly detailed and made the process of changing the diverter valve on my Vaillant Ecotec Plus 837 so easy to follow. I couldn't have done it without your step-by-step guidance. Truly appreciate your effort and the clear explanations!
You're welcome!
Top demo ☝️👍
✌
Yes
Did one last week but just replaced the head. Allowed water ingress so kept tripping the board. Found a brand new head from a local guy. Boiler too old for all this trouble Would love to see full vid though
Main issue is limescale buildup causes not letting pressure into the system through this loop as it can get clogged easily
Error removed but my boiler pressure not getting up. Please help.
Jet wash the extension lead box too lol😊
🫣
Just sent my 456 in for calibration £286 well and truly feel they have had my pants down 😢 mine is 7 years old now, I reckon next year I’ll be in the market for a new one due to its age definitely won’t be a Kane, to be fair the do offer a good service, but I can’t justify the service cost anymore
Wow 😮 that's why Im after a new one
Beautiful and very clean 🔥🫧
Thanks 💯