R-404a gas charging || Cone Ice cream machine gas charging -32 ⁰C

Поделиться
HTML-код
  • Опубликовано: 3 дек 2024
  • #icecream
    #r404a
    #icecreammaker
    R-404a gas charging || Cone Ice cream machine gas charging -32 ⁰C
    Hello Dear friends I hope you all will be fine and very well. Today in this video I have to tell you about the,
    R-404a Gas charging || Ice Cream Storage machine.
    Cone Ice cream machine || R-404a gas charging
    How to charge r-404a refrigerant in ice cream storage machine.
    ice cream storage machine,
    ice cream machine,
    machine for ice cream,
    ice cream,
    how to gas charge,
    how to gas charge R-404a,
    R-404a gas charging,
    R-404a gas charging in ice cream storage machine,
    Refrigerant R-404a charging complete information,
    R-404a,
    Some Important video Links...
    Compressor Voltage and Speed relationship || Effect of voltage on RPM.
    • Video
    R-32 || R-32 complete information || R-32 Safety Precautions
    • R-32 || R-32 complete...
    R-410A || R-410A Properties || Safety Precautions and Complete information.
    • R-410A || R-410A Prop...
    Introduction to R-22 || R-22 complete information || क्या है आर-22 गैस
    • Introduction to R-22 ...
    How to test short in Water Coolor || How do you test water cooler || Troubleshoot in Water cooler.
    • Video
    How to repair old refrigerator || How to check compressor pressure || Flushing condenser with R-12
    • Video
    Thermostat adjustment for water cooler
    • Thermostat adjustment ...
    R-32 and R-410a Blasting reasons || Safety for R-32
    • R-32 and R-410a Blasti...
    How to Check Air Conditioning Unit Performance
    • How to Test split AC P...
    R-600a refrigerator leakage repair
    • R-600 Refrigerator Lea...
    Cone Ice cream machine || R-404a gas charging
    • R-404a gas charging ||...
    R-134a replaced by R-600a || Replacing capillary tube for R-600a || Capillary pressure adjustment
    • R-134a replaced by R-6...
    Freon Refrigerant Identifier or Analyzer || How to identify unknown refrigerant cylinder.
    • Freon Refrigerant Iden...
    Freon Electronic charging scale || Refrigerant charging by weight.
    • Refrigerant charging s...
    Gree AC wiring problem || Gree non inverter AC display not ON problem
    • Gree AC wiring problem...
    HVAC PCB Training, Free HVAC PCB Training course, (FK mech official)
    • Video
    R-600a gas charging || Inverter Refrigerator gas charging
    • R-600a gas charging ||...
    R-600a || How to choose genuine R-600a ? || How to select original R-600a in market.
    • R-600a || How to choos...
    R-600a gas complete information || Safe usage of R-600a || Steps to repair, maintenance R-600 unit
    • R-600a gas complete in...
    How to Know AC, Fridge gas genuine or bad quality. Good and Bad refrigerant
    • How to Know AC, Fridge...
    FK mech official,
    FK,
    FK mech,
    FK mach,
    FK mech official RUclips channel,
    B-Tech in mechanical,
    All about the mechanical engineering,
    Refrigeration and Air Conditioning,
    Refrigeration and Air Conditioning course,
    Hvac related course,
    Refrigeration Theory,
    Thermodynamics,
    Engineering mechanics,
    Mechanical engineering course,
    Instructor Farman Khan,
    basics of refrigeration,
    FK mech official
    Thanks Dear for watching this video, please don't forget to subscribe my RUclips channel
    'FK mech official'.

Комментарии • 117

  • @leftychang
    @leftychang 2 года назад +3

    Great video thanks! I was searching all over RUclips and basically you answered / there is a pressure/temperature correlation - makes sense!

    • @FKmechofficial
      @FKmechofficial  2 года назад

      Thanks Dear Dave Chang for appreciation ❤️

  • @muhammadmajid2931
    @muhammadmajid2931 Год назад +1

    Thanks good information ❤❤❤

  • @uttamjha7569
    @uttamjha7569 2 года назад +1

    Ok sir, best performance for students.

  • @sanjaysharma8306
    @sanjaysharma8306 2 года назад +2

    Thanks you sir I am very happy
    I am Frome Nepal so not use r404agass in Nepal but corrente time I work in Kuwait and confused so thank you ......

    • @FKmechofficial
      @FKmechofficial  2 года назад +1

      How are you confused Dear ?

    • @sanjaysharma8306
      @sanjaysharma8306 2 года назад +1

      I repair sopty ice cream machine and r404agass charging time problem sir
      How is suction presser80_90 not work

    • @FKmechofficial
      @FKmechofficial  2 года назад

      @@sanjaysharma8306 are you Indian ??

    • @FKmechofficial
      @FKmechofficial  2 года назад +2

      @@sanjaysharma8306 Dear for ice cream making the suction pressure of R-404a should be 10 to 12 PSIg

    • @sanjaysharma8306
      @sanjaysharma8306 2 года назад +1

      No sir. I am Frome Nepal and only 2month come in Kuwait so that's region tkanku ..........

  • @wasimedoo7994
    @wasimedoo7994 Год назад +1

    Very good information bro god bless 👍

  • @usmanzaferlohar4960
    @usmanzaferlohar4960 Год назад +1

    Thanks sir for a great work

  • @AyanMechanical
    @AyanMechanical 2 года назад

    Masha Allah nice information 👍

  • @ImranTech-hx4fu
    @ImranTech-hx4fu Год назад +1

    Good information brother

  • @sandeepxaxa9330
    @sandeepxaxa9330 Год назад +1

    Ek no

  • @azmathussain8232
    @azmathussain8232 2 года назад +1

    Aoa bht achi video ha

  • @zahidullah9627
    @zahidullah9627 Год назад +1

    Very good job

  • @udayuday7768
    @udayuday7768 Год назад +1

    Nice video sir thanks

  • @italudin
    @italudin Год назад +4

    Liquid refrigerant must be fill at the discharge line sir, cause not good for the compressor if you fill at the suction line.filling the liquid first time when unit is off.
    Good if you put another charging line at the discharge line and use double scale LP+HP that is for better measuring pressure.
    Adding refrigerant to suction line when compressor ON with gas.
    Sorry if im wrong.
    Salam from Indonesia

    • @FKmechofficial
      @FKmechofficial  Год назад +3

      Dear thanks for your valuable comments...❤️
      Dear sir, during charging the Refrigerant from discharge line is very difficult because the pressure at discharge line is higher than the pressure in Refrigerant cylinder...if we will connect cylinder with discharge line of the unit, the Refrigerant will flow from the discharge line towards the cylinder....

    • @italudin
      @italudin Год назад +1

      @@FKmechofficial is that corect sir, mostly im doing at compressor off, than adding and or reduce refrigerant at the compressor running. Thanks for sharing good video succes for you sir 👍

    • @FKmechofficial
      @FKmechofficial  Год назад

      You are welcome Dear Sir ❤️

    • @ruzainirosli4940
      @ruzainirosli4940 Год назад

      @@italudin salam..bang saya dari malaysia,, boleh ajarkan saya masukan gas r404a untuk reefer tak,, kalau boleh bang tinggalkan nombor handfon saya akan wasap bang..🙏🙏

  • @HarisAhmad-zw3pi
    @HarisAhmad-zw3pi Год назад +1

    Very good

  • @atifbukhari1505
    @atifbukhari1505 Год назад +1

    Good sir 👍

  • @msaeed8031
    @msaeed8031 Год назад +1

    ❤ So nice

  • @snbhomeappliancesrepairing3390
    @snbhomeappliancesrepairing3390 Месяц назад +1

    Sir, kya PT chart say back/Suction pressure Rak saktay hai By Required Evaporator/Cabinet Temperature, Is par ak video banaya Sir

    • @FKmechofficial
      @FKmechofficial  Месяц назад

      @@snbhomeappliancesrepairing3390 yes of course

  • @TariqButt-y8u
    @TariqButt-y8u 3 месяца назад +1

    Aslaam o Alaikum
    Kaplarie tubes sizeee plzzz btaa dyyy

    • @FKmechofficial
      @FKmechofficial  3 месяца назад

      Wa Alaikumussalam,
      Bhai neeche video me details hain...
      ruclips.net/video/wnk4X64IrEM/видео.html

  • @ASHISHKUMAR-cpr
    @ASHISHKUMAR-cpr 11 месяцев назад +1

    Kcm475lal compressor me kitne no ka orifice lagega 30 kg ka 15 block ka plant hai kitna kg gas dalega

    • @FKmechofficial
      @FKmechofficial  11 месяцев назад

      Expansion valve orifice TX2 lagega,
      Awr refrigerant capacity ke hisab se charge hoga brother ❤️

  • @AmanKhan-yo6nm
    @AmanKhan-yo6nm 29 дней назад

    CR 30 404 Gas ka pressure Kitna hoga sar

  • @whathowwhy4629
    @whathowwhy4629 11 месяцев назад +1

    Glass top deep freezer gas 404a but we replaced condencer with small one now. Condenser may be 5 to 6 ft only Is that effect the cooling propertyS? Pleas replay

    • @FKmechofficial
      @FKmechofficial  11 месяцев назад

      Yes, it effects,
      If you will decrease condenser size then refrigerant can't be subcooled well,
      And cooling effect will be decrease

  • @qureshi1866
    @qureshi1866 2 года назад +1

    For -40 temp only liquid refrigerant has to be charged or vapor will also have to be charged??

    • @FKmechofficial
      @FKmechofficial  2 года назад

      It should be charged in liquid state for best results

  • @TheAkash2818
    @TheAkash2818 9 месяцев назад +1

    Sir ji Compressor Kcm 475LALC310H 2 ton ac outdoor main laga sakte hai kulfi machine ke liye please sir data de dijiye

    • @FKmechofficial
      @FKmechofficial  9 месяцев назад

      Brother Laga sakte hain,,, but ye 3 TR kelie design hoti hai

  • @muhammadwaqas2566
    @muhammadwaqas2566 Год назад +1

    Assalam-0-Alaikum Brother, Sir R404 minus 30 tak temperature lay jati ha....
    Kia is ko A.C may charge kar saktay hain...???

    • @FKmechofficial
      @FKmechofficial  Год назад

      No,
      It's using for extra low freezing,
      In AC we don't need extra low freezing.
      Thank you for your valuable comments 🙏

  • @ZahidKhan-jh9ul
    @ZahidKhan-jh9ul 2 года назад +1

    R404 is best gas

  • @javedkasam8138
    @javedkasam8138 Год назад +1

    Use expansion valve or capalery?

  • @nitinsawant5881
    @nitinsawant5881 10 месяцев назад +2

    do the work with complete prosijor .

    • @FKmechofficial
      @FKmechofficial  10 месяцев назад

      Sorry Dear brother,
      What's wrong in the video.
      Please highlight

    • @nitinsawant5881
      @nitinsawant5881 10 месяцев назад +1

      this is wrong no shortcut for success remember that very well ok thanks 👍

  • @hape66666
    @hape66666 Год назад +1

    Sir makeline system r404 gas suction line ice problem i want to know the system how many gas required and back pressure if you know so please reply

    • @FKmechofficial
      @FKmechofficial  Год назад

      What is your required temp in evaporator coil,
      Suction pressure depends upon the evaporating required temp.
      Also depends on application type.

  • @MrMohsin226
    @MrMohsin226 11 месяцев назад +1

    Dear if use 1 ton compressor and r404 refrigerant. Sir what will the capillary size and length also mention condenser and evaporater pipe

    • @FKmechofficial
      @FKmechofficial  11 месяцев назад +1

      Condenser tube:
      Dia: 3/8
      Length : 48ft
      Condenser fan type
      Capillary Tube:
      Dia : 042
      Length : 4ft, 4ft ( Two Capillary Tubes)
      Evaporator:
      Dia : 3/8
      Length : 44ft
      Without fan evaporator

    • @Gosaiganj-q8w
      @Gosaiganj-q8w 7 месяцев назад

      Sir dranfoss Sc21cl Compressor R404a gas Sir what will the capillary size And lenght

  • @nidaassociates7441
    @nidaassociates7441 6 месяцев назад +1

    Is softy machine lbp or mbp

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      LBP brother

    • @nidaassociates7441
      @nidaassociates7441 6 месяцев назад

      @@FKmechofficial but in india it's consider MBP
      SOFTY MACHINE.

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      @@nidaassociates7441 No Dear,
      It is LBP, because the evaporator temp: is almost -30⁰C as you can watch in video

    • @nidaassociates7441
      @nidaassociates7441 6 месяцев назад +1

      @@FKmechofficial sir maine apki machine ki nahin BLKI softy machine ki baat ko

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад

      @@nidaassociates7441 G ok

  • @irfanhaider7115
    @irfanhaider7115 Год назад +2

    Sir I want to maintain -18 lequiid what should psig be?

    • @FKmechofficial
      @FKmechofficial  Год назад +1

      Refrigerator or chiller, Cold Storage ???

    • @irfanhaider7115
      @irfanhaider7115 Год назад +1

      @@FKmechofficial Kulfi plant. Air cool.
      Can I get your WhatsApp no. For details.

  • @nitinsawant5881
    @nitinsawant5881 10 месяцев назад +2

    cooling coil flushing not done capillary and filter drier not replaced new one ok .

    • @FKmechofficial
      @FKmechofficial  10 месяцев назад +1

      Ya, Sorry Dear
      It was just video about R404a gas charging.

  • @ImranTech-hx4fu
    @ImranTech-hx4fu Год назад +1

    Can we charge r404 in refrigerator ?

  • @ziainfotv2576
    @ziainfotv2576 Год назад +1

    sir from which REFRIGERANT to get -70c temperature inside the cabinet i have a blood storage cabinet

    • @FKmechofficial
      @FKmechofficial  Год назад

      In r404,
      But you should have a special system which has the blast type evaporator coil,

  • @luanbui-r3m
    @luanbui-r3m Год назад +1

    sir, what is the suction pressure of this 404 gas for this type of refrigerator, I have measured a suction pressure of about 50psi, working current 2.5a, snow is half closed

    • @FKmechofficial
      @FKmechofficial  Год назад +2

      If you have required temp: -30 ⁰C then you should have the suction pressure 10 Psig for R404,
      If suction pressure increases then your required temp: will also increase

  • @sarfrazahmadfraz2983
    @sarfrazahmadfraz2983 Год назад

    great

  • @ruzainirosli4940
    @ruzainirosli4940 Год назад +1

    Hi sir.. how many charge for reefer r404a compressor 1.5hp -18©

  • @ShahzadKhan-hy8mt
    @ShahzadKhan-hy8mt 2 года назад +1

    And what is pressure r 600 if filled in ac split??

    • @FKmechofficial
      @FKmechofficial  2 года назад

      Dear Shahzad thanks to touch with us...
      The Refrigerant R-600 is not practically applicable in split AC, because it's heat bearing capacity is very low.
      ❤️❤️

  • @tanvirulislam957
    @tanvirulislam957 Год назад +1

    R404 high pressure?

    • @FKmechofficial
      @FKmechofficial  Год назад

      No.....not so much high pressure,
      It's suction pressure should be from 10 Psig to 25 Psig according to the application type

    • @tanvirulislam957
      @tanvirulislam957 Год назад +1

      @@FKmechofficial tell me, condenser temp+ pressure.

    • @FKmechofficial
      @FKmechofficial  Год назад

      @@tanvirulislam957 condenser pressure is from 220 to 260 Psig

  • @ninarohayati8286
    @ninarohayati8286 Год назад +1

    Tekanan berbagai macam freon

    • @FKmechofficial
      @FKmechofficial  Год назад

      Dear brother,,, which language is this ❤️ ?

  • @hamidnawaz6982
    @hamidnawaz6982 2 года назад

    R404 is good gas

  • @nitinsawant5881
    @nitinsawant5881 10 месяцев назад +1

    who will change the filter drier and capillary and flushing of the cabinet.

    • @FKmechofficial
      @FKmechofficial  10 месяцев назад

      What do you mean brother ?
      Who or How ??

  • @babarshairbabar693
    @babarshairbabar693 Год назад +1

    پاکستانی ہیں بھائی جی۔خدارا اردو بولیں

    • @FKmechofficial
      @FKmechofficial  Год назад

      صحیح بات ہے بھائ۔
      انشاء اللہ

  • @rehanrana2224
    @rehanrana2224 Год назад +1

    یہ فریزر کہاں سے ملے گا؟

    • @FKmechofficial
      @FKmechofficial  Год назад +1

      Ye Local Bana hwa hai....Kisi mechanic ne banaya hai...

    • @rehanrana2224
      @rehanrana2224 Год назад +1

      @@FKmechofficial karachi main kae jaga poocha ha koe info ya detail nahe mile

    • @FKmechofficial
      @FKmechofficial  Год назад

      @@rehanrana2224 pyare bhai local Ka MATLAB ye aap khud se bhi Bana sakte ho...

    • @rehanrana2224
      @rehanrana2224 Год назад

      @@FKmechofficial guide pls karegar ko ja ker kia bolna ha kia mechine lagae kia compreser lagae kia gas bhare kia boloon? Pls guide

  • @omhri853
    @omhri853 10 месяцев назад +1

    This unit diagram

  • @arisdionela9755
    @arisdionela9755 6 месяцев назад +1

    I Don, t know why liquid charging some refrigerant but liquid is danger to compressor parts 😅

    • @FKmechofficial
      @FKmechofficial  6 месяцев назад +1

      Dear, all the blends refrigerants which are the mixture of two or more than two refrigerants should be charged in liquid for accurate ratio of each particular refrigerant.
      Yes liquid can be dangerous, but should be charged slowly.

  • @malikt113
    @malikt113 Год назад +1

    Yar urdu bola karo