I NEED HELP !!! 😢😢😢 I used an S7 300 PLC with a DIGITAL OUTPUT MODULE. I made a very simple program with Q0.0 as an output. I plugged a cable from Q0.0 to DIN1 (terminal 5), P700=2 to enable using terminals, P701=1 to use DIN1 as ON/OFF, P1000=1 for MOP setpoint. The program works, the Q0.0 Led lights up and i tested a 24vDC in terminal 5 STILL !!! the Drive doesn't start 😡.
I found this video and your previous video on 2-wire control very helpful. Have you ever tried to use the drive with an external JOG button? I am struggling to interpret the manual as to how to incorporate an external JOG!
Hi There. How far have you gotten with particular task you are trying to achieve. Have you assigned the jog function to any of the inputs. Manual page 46 onwards?
@@IGSElectronics Hi. I am not sure which input I can assign the jog function to. I may have to forget about trying to incorporate a JOG button and stick with the basic 2-wire configuration.
@@glynbrandon861 Ok, lets se if we can make this work. For the 2 wire control you are using input 1 to go forwards as def, input 2 is set for reverse and input 3 is reset. So if you go to par 703 and change input 3 to 10 for jog forwards or 11 to job backwards, your input 3 will be changed to jog now so you should be good to go. Let me know how it go.
Hi there. It would be hard for me to pinpoint the problem without having the drive in front of me for this kind of problem. So don't think i be much help to you.
Good basics to use the drive
I NEED HELP !!! 😢😢😢
I used an S7 300 PLC with a DIGITAL OUTPUT MODULE. I made a very simple program with Q0.0 as an output. I plugged a cable from Q0.0 to DIN1 (terminal 5), P700=2 to enable using terminals, P701=1 to use DIN1 as ON/OFF, P1000=1 for MOP setpoint. The program works, the Q0.0 Led lights up and i tested a 24vDC in terminal 5 STILL !!! the Drive doesn't start 😡.
Can you pls advise how to operate from key pad.before it was operating from key pad .now when i switch on the main breaker VFD automatically start
Der Sir.how to convert local/remote by DI & control frequency with 4-20mma . signal
I found this video and your previous video on 2-wire control very helpful. Have you ever tried to use the drive with an external JOG button? I am struggling to interpret the manual as to how to incorporate an external JOG!
Hi There. How far have you gotten with particular task you are trying to achieve. Have you assigned the jog function to any of the inputs. Manual page 46 onwards?
@@IGSElectronics Hi. I am not sure which input I can assign the jog function to. I may have to forget about trying to incorporate a JOG button and stick with the basic 2-wire configuration.
@@glynbrandon861 Ok, lets se if we can make this work. For the 2 wire control you are using input 1 to go forwards as def, input 2 is set for reverse and input 3 is reset. So if you go to par 703 and change input 3 to 10 for jog forwards or 11 to job backwards, your input 3 will be changed to jog now so you should be good to go. Let me know how it go.
Analog out put 4_20Ma not coming from the inventer to syncroinsn with other to decrease the speed
Hi there. It would be hard for me to pinpoint the problem without having the drive in front of me for this kind of problem. So don't think i be much help to you.
Tem o esquema elétrico para passar...
can you please suggest me how to increase torque ?
Best way is to upgrade your drive to handle bigger torques.
Sir can we programe it in BICO
What is BICO?
Sir pls give me the diagram hor to connect those wire and how to set the parameter to run it with reverse and forward direction pls.
Hi There. I don't have wiring diagrams, please fallow the video instructions.
7:20
อินเวอร์รุ่นนี้ที่เป็นรุ่น30HPสามารถใช้กับมอเตอร์20HPได้ไหมครับ