Concreting of Pile foundation

Поделиться
HTML-код
  • Опубликовано: 4 авг 2023
  • #shorts
    #civilengineering
    #construction
    #concrete
    #sitevisit
    #foundation
    #piles
    #sardarpatil

Комментарии • 114

  • @shajimuttath216
    @shajimuttath216 9 месяцев назад +20

    Important part is that no cover blocks seen as the reinforcement steel is in contact with the soil

  • @candrasniper3404
    @candrasniper3404 9 месяцев назад +9

    I think you are an architect, not a civil engineer. You share this proudly without knowing something wrong about it.

  • @Samisada-vn7fk
    @Samisada-vn7fk Год назад +89

    This is a totally wrong way to cast pile foundation..

    • @ddwibedi1
      @ddwibedi1 10 месяцев назад +7

      Yes , RMC should be pouring through treme pipe .

    • @user-bh2js8bd6p
      @user-bh2js8bd6p 10 месяцев назад +1

      안민주당놈들죽어다

  • @shihabchowdhury9348
    @shihabchowdhury9348 11 месяцев назад +20

    There will be sagrigation definitely. Its not correct method to pore cast in situ pile . Use casing pipe for pouring from below to top

  • @dioneirobert5174
    @dioneirobert5174 11 месяцев назад +35

    When you arrive at the last minute 😂

  • @johndebritto1573
    @johndebritto1573 9 месяцев назад +2

    This cast in situ concrete pile without casing,need cover blocks to protect the reinforcements from corrosion.
    The concre pouring should be through a trunk funnel to prevent seggrigation of readymix concrete..
    At the top atleast a temporary casing pipe to avoid surface earth getting mixed up with RMC

  • @aadil8715
    @aadil8715 8 месяцев назад +3

    With that dia of pile and thickness of steel, tlwhat were you thinking?🤦‍♂️🤦‍♂️

  • @franciscocarlosferreira1929
    @franciscocarlosferreira1929 10 месяцев назад +5

    o engenheiro que fez o projeto de estaca merece ser preso, em que escola que ele aprendeu a fazer estribo em espiral (forma de mola)

  • @raz16490
    @raz16490 11 месяцев назад +6

    Wrong procedure for pouring of concrete

  • @AK-ek8vf
    @AK-ek8vf 8 месяцев назад +2

    Bar are 8 mm , should be atleast 12 mm above

  • @sameerahmad7033
    @sameerahmad7033 11 месяцев назад +1

    When im eat maggi at night😂😂

  • @Anjalkashyap1994
    @Anjalkashyap1994 10 месяцев назад +4

    This is wrong way to do pouring, don't creat wrong video

  • @mayurkshirsagar5333
    @mayurkshirsagar5333 11 месяцев назад +3

    This is not right way to concreting of pile foundation

  • @josegregoriomoralesferrini4587
    @josegregoriomoralesferrini4587 9 месяцев назад +2

    me parece qué lo qué pude estudiar en La universidad sobre el concreto y el acero fué diferente a está práctica

  • @user-cp3cv9nb8j
    @user-cp3cv9nb8j 10 месяцев назад +3

    Muito pouco ferro nesse ferro.
    Ainda mais aí nesse país .tem que estudar o clima se país tem terremoto abalo cismico etc
    Para construir um prédio ou que seje.
    (Obs) Muito pouco ferro

  • @Tuyen980
    @Tuyen980 8 месяцев назад +1

    Hay quá,công việc tôi yêu thích

  • @imrozkhan4412
    @imrozkhan4412 Год назад +6

    Cover block ?????

  • @Supinder_Mishra
    @Supinder_Mishra 11 месяцев назад +1

    You should use treamy pipe for casting

  • @JoseRomero-km3jn
    @JoseRomero-km3jn Год назад +4

    Ejemplo dd como no se vacia el concreto en pilotes .

  • @fatemulsumon8950
    @fatemulsumon8950 10 месяцев назад +4

    Not the correct way of casting...treme pipe must be imerged under concrete and casting process must be bottom to top...this will cause segregation

  • @massimorusso9141
    @massimorusso9141 11 месяцев назад +4

    Questo getto nel palo puo' far franare il terreno circostante ⚠️ meglio calare all' interno centrale il tubo dell' autopompa

  • @sheikhshahnawaz4929
    @sheikhshahnawaz4929 11 месяцев назад +3

    Wrong work ......Use cassion and trimmy pipe and poring with use of mesh

  • @physicalhealth5580
    @physicalhealth5580 Год назад +2

    👌

  • @SivamShakthi234
    @SivamShakthi234 8 месяцев назад +1

    👍🏻

  • @ersanjaynit
    @ersanjaynit Месяц назад +1

    Brother don't put concrete edges please put in center thank you comment by Civil Engineer Sanjay

  • @mathematico6045
    @mathematico6045 6 месяцев назад +1

    Concrete should be fill through tremie pipe. So that chances of segregation would be reduced

  • @aijuddinskr.k.thakchard-nk3gf
    @aijuddinskr.k.thakchard-nk3gf 5 месяцев назад

    ❤❤

  • @gangstar1944
    @gangstar1944 8 месяцев назад +2

    Where is tremie pipe ???

  • @maheshn8039
    @maheshn8039 10 месяцев назад +1

    Where's the form pipe/ casing pipe

  • @supriyas_tadka
    @supriyas_tadka Год назад +6

    Slump-collapse

    • @roxytech107
      @roxytech107 10 месяцев назад +1

      This may be self compacted ..or high strength design mix...usually this slump value always high

    • @supriyas_tadka
      @supriyas_tadka 10 месяцев назад

      @@roxytech107 for self compacting, flow table test performed

  • @Asr129
    @Asr129 11 месяцев назад +1

    Where is vibrator

  • @findsamim
    @findsamim 11 месяцев назад +4

    FIR should be filed against this contractor.

  • @AkashYadav-rx2jc
    @AkashYadav-rx2jc 11 месяцев назад +1

    Concrete placing with the help of tremie pipe shall be a continuous operation from the toe level to the cutoff level of the pile. Piles shall be cast up to a minimum height of 600 mm above the cutoff level of the pile foundation.

  • @keshariciviltech6719
    @keshariciviltech6719 9 месяцев назад +1

    Wrong pouring of Concrete in pile

  • @ronaldmaxwell1108
    @ronaldmaxwell1108 10 месяцев назад +7

    I don’t know about the” tremie pipe, I am more concerned about it not getting vibrated.

    • @roxytech107
      @roxytech107 10 месяцев назад

      May be its, self compacted concret no need to vibrate ...see the slump

    • @Rk-cv3tc
      @Rk-cv3tc 9 месяцев назад

      For that much slump vibration will only cause settling of aggregate.

    • @ajay4064
      @ajay4064 8 месяцев назад

      ​@@roxytech107😂

  • @chiranjeeviadla7731
    @chiranjeeviadla7731 Год назад +4

    Use trime pipes & hoper funel use to concreting of pile

  • @user-rm6td1im8l
    @user-rm6td1im8l 9 месяцев назад +1

    อ่าวแบบนี้ไม่กลัวดินดูดน้ำในเนื้อปูนเหรอคับ

  • @fcenalia
    @fcenalia 11 месяцев назад +3

    Totally wrong!

  • @sanb3586
    @sanb3586 10 месяцев назад +1

    Where is the 1 metre rule 😢

  • @tanveerahmadlodhi731
    @tanveerahmadlodhi731 11 месяцев назад

    In the pills concrete should comout from deep to up by use pipe

  • @mubashirmughal847
    @mubashirmughal847 11 месяцев назад +6

    segregation will happen

  • @dinkumteng
    @dinkumteng 8 месяцев назад +1

    मिट्टी में कंक्रीट क्यों गिरा रहा है!

  • @ezeemmanuel5229
    @ezeemmanuel5229 9 месяцев назад +1

    Inadequate lapping zone

  • @eriwidianto2101
    @eriwidianto2101 10 месяцев назад

    Cor pinggiran nya gak di pasang ta ,gak bahaya ta😅

  • @joaquinperonalucas5027
    @joaquinperonalucas5027 Год назад +1

    Sin usar el vibrador eso está muy mal

  • @mohammadashar6745
    @mohammadashar6745 11 месяцев назад +1

    This is not the way to cast pile.. Where is your tremie ?

  • @Divyang_24
    @Divyang_24 Год назад +1

    Ratio kiya hota ka mixture ka?.

  • @VishalKumar-cb5ej
    @VishalKumar-cb5ej 11 месяцев назад

    Me in morning everyday 🥴😅

  • @henryviteri
    @henryviteri 9 месяцев назад

    Bueno.....mientras no caigan particulas de tierra, puede valer...la altura de donde cae hace que compacte, pero mas seguro , si pones un vibrador en parte superior de la estrctura. Ayuda a compactar el hormigon.

  • @girishbajpai2505
    @girishbajpai2505 10 месяцев назад +1

    ट्रीमी युज करना चाहिये

  • @muhammadislamalam2394
    @muhammadislamalam2394 11 месяцев назад +1

    It must be 1 or 1.5 meter high then earth level. Later hacking

  • @etl7761
    @etl7761 10 месяцев назад +1

    China ?😢

  • @longlong8722
    @longlong8722 10 месяцев назад +1

    Phải đưa ống D200 xuống đáy và đổ bê-tông từ đáy lên.

  • @user-rr4eb7sw2c
    @user-rr4eb7sw2c 9 месяцев назад +1

    好療癒ㄛ❤

  • @mrindia077
    @mrindia077 11 месяцев назад +1

    This is wrong way for pile casting

  • @user-BSI_spb64
    @user-BSI_spb64 5 месяцев назад

    У Российского ТЕХНАДЗОРА во всех местах зачесалось после этого видео...!

  • @user-pw2qz9xd7f
    @user-pw2qz9xd7f 10 месяцев назад

    Утро после разливного пива

  • @arunbalachandran6014
    @arunbalachandran6014 9 месяцев назад +1

    First vybratter down then concrite

  • @mr.grinchsolo5327
    @mr.grinchsolo5327 5 месяцев назад

    Bro funnel need to used this condition

  • @rahulkumarsaroj3879
    @rahulkumarsaroj3879 5 месяцев назад

    Collapse hai slump value

  • @sebastiaoaredis816
    @sebastiaoaredis816 6 месяцев назад

    Boa fundação 😮

  • @sibhmz3697
    @sibhmz3697 5 месяцев назад

    How about concrete drop?

  • @AjitKumar-ol8ue
    @AjitKumar-ol8ue 9 месяцев назад +1

    Wrong pouring !! Use Trime PIPE

  • @er.anilkumarcivil3753
    @er.anilkumarcivil3753 Год назад +2

    Very very wrong practice, disgusting

  • @ronaldmaxwell1108
    @ronaldmaxwell1108 10 месяцев назад

    I don’t know about the Tremlett

  • @MonuThakur-hl2th
    @MonuThakur-hl2th 11 месяцев назад

    In starting pipe says:- 🤮🤮🤮

  • @nitaipurkait7696
    @nitaipurkait7696 8 месяцев назад +1

    Wrong casting

  • @dambisol1338
    @dambisol1338 9 месяцев назад

    날림공사
    흙이 섞여서 힘을 쓰겠나?

  • @deveshgupta2588
    @deveshgupta2588 11 месяцев назад +1

    😢 tauba tauba saara mood kharaab kardiya.

  • @eriwidianto2101
    @eriwidianto2101 10 месяцев назад

    Tengah nya gak pakek besi 20 dim ta😅

  • @gujjargujjarlion6240
    @gujjargujjarlion6240 9 месяцев назад

    reject
    sagrigation,😮

  • @karthikumar4325
    @karthikumar4325 6 месяцев назад +1

    Is code number

  • @EvergreenConsultancy
    @EvergreenConsultancy 8 месяцев назад +2

    WRONG

  • @shankardasshivas
    @shankardasshivas 9 месяцев назад +1

    concreting is wrong nd defective,inexperienced engineer

  • @cyberattacks_2023
    @cyberattacks_2023 11 месяцев назад +1

    Useless engineer the concrete mix with soil whole poring so that fail

    • @muhammadislamalam2394
      @muhammadislamalam2394 11 месяцев назад

      Soil not mixing, but it come on the surface, 8t must be high later hacked

  • @NatarajanKavi-ji7qy
    @NatarajanKavi-ji7qy 8 месяцев назад +1

    தமிழ்

  • @pratyushnayak7917
    @pratyushnayak7917 10 месяцев назад +1

    Wrong process

  • @futurelifestyle2698
    @futurelifestyle2698 9 месяцев назад

    Hug diya😅😂

  • @computerpeeperoyome2017
    @computerpeeperoyome2017 9 месяцев назад

    Ko...you no me...% understand
    No one %

  • @er.anilkumarcivil3753
    @er.anilkumarcivil3753 10 месяцев назад +1

    Don't show bludy practice
    Wrong practice

  • @abhisheksinghal3539
    @abhisheksinghal3539 11 месяцев назад +1

    Treme pipe kha hai

    • @ramjankhan6033
      @ramjankhan6033 11 месяцев назад

      sukha pile hai jarurat nhi temi ki

  • @toremaduff5319
    @toremaduff5319 11 месяцев назад

    muralha hee

  • @velanp562
    @velanp562 Год назад +1

    Worst work man ship

  • @debankurbaruah5728
    @debankurbaruah5728 9 месяцев назад +1

    Totally wrong

  • @edwardcoutinho7857
    @edwardcoutinho7857 11 месяцев назад

    Cai terra

  • @sopheaktranea
    @sopheaktranea 10 месяцев назад +1

    pouring concrete into bore pile isn't correct because we need to tremie pile to flow of concrete.

  • @nafeesahmed2582
    @nafeesahmed2582 11 месяцев назад

    Tumlog kuchh bhi kate ho trimme pipe or hopper ke bina kuchh bhi dikha ke bewqoof banate ho

  • @clansofmusic4410
    @clansofmusic4410 9 месяцев назад

    Haus dan

  • @astritbushaj580
    @astritbushaj580 9 месяцев назад

    Non va bene non li controlla nessuno ci vuole il tubo getto 🙈

  • @munkitfoong6528
    @munkitfoong6528 10 месяцев назад

    Disaster

  • @tiagodias8147
    @tiagodias8147 9 месяцев назад

    💩💩🌝

  • @user-gi5pn4pk8e
    @user-gi5pn4pk8e 11 месяцев назад

    파일을 이런식으로하나 !

  • @deepakdalal9995
    @deepakdalal9995 11 месяцев назад

    Totally wrong