CONTROL VALVE HUNTING

Поделиться
HTML-код
  • Опубликовано: 26 ноя 2024

Комментарии • 66

  • @mharis1122
    @mharis1122 2 года назад

    Sir you are hard worker , and real expert ,

  • @Usman.9234
    @Usman.9234 2 года назад +1

    Jazakallahukhair 👍👍 great sir

  • @ZulfiqarAli-pt2ec
    @ZulfiqarAli-pt2ec 2 года назад +1

    Nice dear keep it .

  • @mharis1122
    @mharis1122 2 года назад

    Thanks alot sir for sharing

  • @sharmapintu1737
    @sharmapintu1737 2 года назад +1

    nice information sir

  • @AFSARmohd999
    @AFSARmohd999 2 года назад +1

    Jazak Allah Khair

  • @mdsalik1289
    @mdsalik1289 2 года назад +1

    Great work sir

  • @muhammadumair2820
    @muhammadumair2820 Год назад +1

    Safety valve travee test k bary me video upload Kary sir.

  • @SandipPatel-hy7st
    @SandipPatel-hy7st 2 года назад +1

    Can you explain what is contr valve dead Band options?

  • @moienitech2110
    @moienitech2110 Год назад +1

    Good very informative video and there are suggestions.
    Kindly before to make this type videos get well prepared and use proper tools to minimise tube or fittings damage.
    Another use snoop to check leak if not available you can use a water bottle but make a minor pin hole in the cap of the bottle and use it to minimise and control the water flow and explore everywhere like in this video.newcommer watching this video's and they should aware all the things in proper manner.thanks.

    • @instrumentexpert7780
      @instrumentexpert7780  Год назад +1

      Really appreciate your suggestions dear

    • @syedhassan3759
      @syedhassan3759 10 месяцев назад

      Positioner kaun sa hai sir please bata ye company ka naam

  • @muhammadkashif3651
    @muhammadkashif3651 2 года назад +1

    Great efforts,
    Good work.

  • @abhishek1997gujjar
    @abhishek1997gujjar Год назад +1

    M chata hu aapka chenal hmesa chlta rhe or ham sikhte rhe

  • @mdakbarkhan956
    @mdakbarkhan956 2 года назад +1

    Sir sukriya

  • @mohammadarif1777
    @mohammadarif1777 2 года назад +1

    Assalam walikum sir signal isolate kaise karte hai

  • @pritamkumar-ir3fe
    @pritamkumar-ir3fe 2 года назад +2

    👍

  • @abhishek1997gujjar
    @abhishek1997gujjar Год назад +1

    Tq so much sir

  • @mohammadimtiyaz5824
    @mohammadimtiyaz5824 2 года назад +1

    Sir single acting aur double acting positioner q use hota hai, explain kijiye

    • @instrumentexpert7780
      @instrumentexpert7780  2 года назад

      Depends on process kahin hmy only one position from signgla oar kahen both positions from signal chahaee hoty hin

  • @vishalpimple159
    @vishalpimple159 2 года назад +1

    Make video on ABB positioner working and how to do calibration through keys

    • @instrumentexpert7780
      @instrumentexpert7780  2 года назад

      Yes it's already and I have many videos for ABB POSITIONER CALIBRATION THROW KEY BUTTON

  • @chandreshparmar4092
    @chandreshparmar4092 2 года назад +1

    Thank You sir

  • @Irk-ys9tr
    @Irk-ys9tr Год назад

    Sofy water kya hai sir

  • @Islamic-q6p
    @Islamic-q6p 2 года назад +1

    Walikum salam great keep it up 👍👍👍

  • @AvnishKumar-mk1bk
    @AvnishKumar-mk1bk 2 года назад +1

    DBC 6200 postiner calibration told me

  • @javedalam1768
    @javedalam1768 2 года назад +1

    ek control valve hai fail to close, aur usme DVC positioner hai, aur valve abhi close hai, lekin positionet k vent se aur countinue vent ho raha hai, kiya problem hai batayenge, please

    • @instrumentexpert7780
      @instrumentexpert7780  2 года назад

      Javed Bhai AP control valve ka behavior check kren usmi koi hunting Hy??
      Agr hunting Hy to pneumatic rely check kren , may be ki uska koi diaphragm leakage ho

  • @dineshbaghele5554
    @dineshbaghele5554 2 года назад

    Control valve troubleshooting problem kese shortout karte h please provide video sir ji

  • @mohammadkamran2382
    @mohammadkamran2382 2 года назад +1

    ye ABB ka cantrol valve hai iss pr Maine kaam kiya hai power plant m

  • @abhishek1997gujjar
    @abhishek1997gujjar Год назад +1

    Koi Technician ke liye Job ho to sir muje btayiyega

    • @instrumentexpert7780
      @instrumentexpert7780  Год назад

      Sir jobs boht hoty hyn, ap cv behtreeeen bnaee oar interview ki full tyary kren

  • @mdshayanahmad6838
    @mdshayanahmad6838 2 года назад

    Control valve kitne types ki hoti hai

    • @instrumentexpert7780
      @instrumentexpert7780  2 года назад

      Fixed nhe hi sir
      Glob valve ,ball valve , butterfly valve ,needle valve ,angle valve

  • @mohammadarif1777
    @mohammadarif1777 2 года назад +1

    Assalam walikum sir control valve me 25% ka command dene par 27% open ho raha hai iska kya reason hai aur solutions

    • @instrumentexpert7780
      @instrumentexpert7780  2 года назад +1

      Boht sary masly ho skty hin.
      Misal
      Calibration fault
      Local scale adjustment
      Spane out

  • @mdakbarkhan956
    @mdakbarkhan956 2 года назад +1

    Allah ka sukar hai

  • @mhodbadoruddinbadoruffi7345
    @mhodbadoruddinbadoruffi7345 Год назад +1

    Aap ko proper tools use Karen yani spner 18no

  • @SurajSingh-wk1tk
    @SurajSingh-wk1tk Год назад

    Sir ek question tha sir Jo hmara control Valve ka actuator hota hai usme Jo nut bolt lgate h vo sab same size k. Hote hai but ek 2 nut bolt bade kyu hote h uska bada hone ka kha reason h sir plz reply

    • @moienitech2110
      @moienitech2110 Год назад

      Using a big size to minimise actuator spring tension high to low. And safe to open the actuator without any damages and accidents.