Daikin VRV4 | A-series | wireless checker | Preventive Maintenance.
HTML-код
- Опубликовано: 10 июн 2022
- Brand : Daikin VRV4 (A-series)
model : RXQ14AYM
Using Daikin wireless adapter to collect indoor and outdoor data.
compare the pressure with pressure guage,wireless adapter and MPa from 7 segment.
#bonmj #daikin #vrv
Muito bom o seu nível de conhecimento.
amazing video
Thanks!
Excellent information
Thanks
Nice work Bon.. I wish the wireless checker had more control with the ability to switch indoor units on/off and be able to adjust temperature remotely as well
Thanks bro
Thank you sir bon
Welcome
God information sir❤
Thanks
Hi bon nice video 🇹🇷🛠️🤳🍻👍
I have Daikin service checker
i am using type 3.1
Welcome 👍👍👍
Super sir
Thanks
Bon, thanks. How useful is this device?
Thank you for another excellent video. Where is the hot gas pipe at 1:51 ?
Red color
👍🏻
Thanks
Hi Bon,,,,,, how are you my dear friends ,,,,always professional,,,as usual….the DAIKIN CHECKER IT IS COMPATIBLE WHIT IPHONE PAD TABLET ?
Should no problem
Another great video! What's the name of the app?
Daikin air conditioner monitoring tools
What is the difference between D-checker and Blue Tooth Service Checker?
D checker using laptop and bluetooth checker using handphone
Hi Bon where did you buy adjustable service valve for liquid line? The one to install gauges on
Thank you
Online.
U in Singapore?
@@BonMj Cali , bought it on Amazon. Thanks
@@epicone2449 👍
hi mr. Bon I want to ask about the wireless checker. field use for vrv 4 A series mr. bon using socket x27a pin 5 or 7?
5
@@BonMj oh, 5 pins. in Indonesia the purchase of a wireless checker can only be a checker and 7 pin socket. to get a 5 pin socket, you have to buy another adapter.. is there a difference between checkers in Singapore and Indonesia?
Brother for checking pressure u used some safety valve, just tell me the name.
Refrigerant charging valve adapter
Thanks bro
@@arifbabulotapalkatti7643 welcome
Hi bon very nice ... Bon can you explain daikin system 3 UH error code
Sorry late reply.
Check communication wire,indoor pcb or outdoor pcb
Is the D-checker same as Blue tooth service checker?
Yes
Where can i buy wireless adapter? Thanks
Daikin
❤9 7:15 ❤😘😘😘😘
Hi bon , We can turn On / Off fcu. or adjust temperature with wireless checker ?
Daikin cant
Only can force on using monitor mode
@@BonMj Thank ☺️☺️☺️
How to resset Daikin ceiling concealed AC thermostat control not working
Thermostat control or remote control?
@@BonMj thermostat control
Because I cleaned condenser unit and switch off the breaker outdoor unit ..if on the breaker indoor unit in thermostat no power
@@kabalbasisla1871 got control panel?
Mitsubishi city multi VRV error code 1500.plz tall me sir what is the problems...
May overcharge
Hi Mr.Bon where can I get the wireless checker. I am from India plz help
From Daikin
Can see whether the solenoid valves status with this device?
Yes
@@BonMj Thanks, Bro.
@@josephngmh2815 welcome
Sir I want to work with you 🙂
U4 error is is showing in my vrv 3 inverter outdoor unit of daikin. Indoor unit is working fine but outdoor unit is not starting.
Can u plz help 🙏🏻
Check main pcb or comunication wire
@@BonMj the technician changed the PCB but were asking for the old pcb, can the old pcb be fixed?
Thank you so much for helping and answering 🙏🏻
@@sonali5760 mean the main pcb is faulty.
Normally we just replace the new pcb.
Depend by the pcb repair cos,if send to check or repair need time and not sure the cos.0
I want to buy a check kit, how can I buy it, sir?
Daikin
Sir vrv3 test runs mode code telmi pls
Press test button more than 5second.
good job, Bon, I hear that you speak chinese with the another guy. maybe he is a learner.
Thanks
What's the app using for mobile...
Daikin air conditioner monitoring tool.
Ver 1.1.32
@@BonMj thanks for your kind reply...
Dear Bon..how can I contact you...
@@asangajayalath1665 email.
bonmj81@gmail.com
Bon sir, daikin vrv iv model error code JC -10 plz guide &solve error, please comment, thank you
Check pressure and low pressure sensor
@@BonMj this one is showing problem
@@anilpradhan2263 what problem ?
How much wireless checker's?
S$300/=+
Hi Bon, excellent job, where can I get that wireless device?
Thanks
@@javiaus231 Daikin
Sir Daikin vrv3 p1 error y problem
Open phase voltage imbalance
@@BonMj but sir compressor on continue but fan of fan on to compressor of y this problem sir
@@mohdmaqsoodshaikh5234??
Compressor on to fan of fan on to compressor of
@@mohdmaqsoodshaikh5234 how is the 3phase and voltage