  • @dmohac3557
    @dmohac3557 4 дня назад

    Now I understand the little hole on the bottom of the pipe!
    Thanks

  • @RickPotvin54
    @RickPotvin54 2 года назад +1

    I just play piano and teach piano lessons. This was a very good lesson, thanks. I understand better now.

    • @AirConAcademy
      @AirConAcademy  2 года назад

      I'm so glad that you liked this lesson. I'm glad I could help you understand better. I like teaching and it is great when I know it helps you guys out there!

  • @josephkwon9034
    @josephkwon9034 2 года назад +3

    good explanation and now I understand 100%

    • @AirConAcademy
      @AirConAcademy  2 года назад +2

      I'm so glad to hear you say that! That's why I do these videos, trying to help you guys out there understand things a little better. Thank you so much!

  • @davidb7016
    @davidb7016 24 дня назад +1

    What happens if let’s say you have too much liquid refrigerant coming back to the accumulator and it’s getting trapped there? You have your accumulator freezing up and the system goes into vacuum, heat mode in a heat pump

    • @AirConAcademy
      @AirConAcademy  23 дня назад

      That, is a good question. at the bottom of the accumulator there's that orifice that keeps pulling the liquid refrigerant from the bottom into the system and it atomizes it due to the ventury affect so that we always keep liquid refrigerant going back to the compressor when it is atomized the compressor, compresses it and keeps the system going. I hope this answers your question. That was a good question! Thank you for sending that in and thank you for watching!

  • @hectortorres542
    @hectortorres542 4 года назад +4

    Thank you for the video very good training course for beginners just a note accumulators should be insulated

    • @AirConAcademy
      @AirConAcademy  4 года назад +1

      They do not need to be insulated. accumulators will sometimes have the liquid line going through them to boil the liquid in the accumulator. Remember we want the liquid in the accumulator to evaporate. Insulation will keep the liquid from evaporating, unless there is a heater attached to the accumulator.

  • @mahmoudelnahry8473
    @mahmoudelnahry8473 4 года назад +1

    You are the best teacher

    • @AirConAcademy
      @AirConAcademy  4 года назад

      Thank you!!! I appreciate your comment!!!

  • @aboodal3amri376
    @aboodal3amri376 11 месяцев назад +1

    Big like ❤ thank you

    • @AirConAcademy
      @AirConAcademy  11 месяцев назад

      Thank you! And thank you for watching!

  • @str8kronic
    @str8kronic Год назад +1

    So the liquid refrigerant doesn't harm the the compressor as long as it's in a fine mist form ?

    • @AirConAcademy
      @AirConAcademy  Год назад +2

      Correct! Typically when that missed goes into the compressor it is first, going to come in contact or come close to the motor and the heat from the electric motor that is running the compressor , this hat will instantly evaporate the mist!
      If you have too much liquid coming in because you don't have an accumulator then you're going to wipe the bearings, they're going to be clean, and they will not have any lubricant so your compressor will fail! I hope this makes sense, thank you for your message and thank you for watching!

  • @sebastianboyd1769
    @sebastianboyd1769 3 года назад +1

    Back at Teck at the moment your videos are great, appreciate it buddy ✌️👍

    • @AirConAcademy
      @AirConAcademy  3 года назад

      Thank you so much!!!! I am glad you like the videos!!!

  • @yeallen9468
    @yeallen9468 Год назад +1

    excuse me sir I have a question, as video said there will be more and more liquid refrigerant in accumulator how to handle it, and whether the oil will get into the AC system or just in compressor

    • @AirConAcademy
      @AirConAcademy  Год назад

      Thank you for sending the question in. The liquid refrigerant, and the oil will go back to the compressor through that small port at the bottom of the U tube. It's designed that way to make sure oil always comes back to the compressor. Oil always travels with the refrigerant, so there will be oil traveling through the system every time the unit is running. I hope this answers your question! And thank you for watching!

  • @DarkSim77
    @DarkSim77 3 года назад +1

    TY for the easy to understand explanation.

    • @AirConAcademy
      @AirConAcademy  3 года назад +1

      And thank you very much for the comment and for watching! I'm glad you liked it!

  • @grasshopper3085
    @grasshopper3085 2 года назад +1

    Perfect explanation

    • @AirConAcademy
      @AirConAcademy  2 года назад

      Thank you so much and thank you for watching!

  • @mohanjayaraj5528
    @mohanjayaraj5528 2 года назад +1

    Thank you so much, Very clear explanation

    • @AirConAcademy
      @AirConAcademy  2 года назад +1

      Thank you so much I appreciate your comment!

  • @tempeberkahmaju7281
    @tempeberkahmaju7281 2 года назад +1

    Makasih pak ilmunya 👍👍👍🥰🥰

  • @kalihue4619
    @kalihue4619 2 года назад +1

    excellent teacher. thank you very much sir

    • @AirConAcademy
      @AirConAcademy  2 года назад

      Thank you! And thank you for watching!

  • @mdmuntasiralam774
    @mdmuntasiralam774 Год назад +1

    Thanks for the wonderful video.

    • @AirConAcademy
      @AirConAcademy  Год назад +1

      Thank you! And thank you for watching!

  • @misaelmoreno488
    @misaelmoreno488 5 лет назад +6

    Thank you so much it was a excellent explanation

    • @AirConAcademy
      @AirConAcademy  5 лет назад +1

      Thank you for joining our group. Hope all our videos are very helpful. We will be hosting a free webinar on March 27th at 11 am EST. Here is the link: events.genndi.com/register/818182175026330270/72d81d0437

    • @AirConAcademy
      @AirConAcademy  5 лет назад

      Thank you!!! If you have any requests please let me know!!!

  • @AKK105
    @AKK105 2 года назад +1

    Will the accumulator get over flow as the liquid refrigerant are coming in?

    • @AirConAcademy
      @AirConAcademy  2 года назад

      If the accumulator is sized properly it should not get overflow of liquid refrigerant going back to the compressor. If someone has overcharged the system then, yes liquid would still make it to the compressor but the accumulator would have to be practically full of liquid refrigerant. I hope this helps! And thank you for watching!

  • @thunderdragon888
    @thunderdragon888 Год назад

    Thanks for the video. What happens to the remaining refrigerant liquid inside the Suction Accumulator ? Is it going to vaporize ? Should the Suction Accumulator be insulated or not because a lot of customers are insulating ? If it is insulated from exterba heat then how does the liquid Refrigerant inside the said Suction Accumulator evaporate?

    • @AirConAcademy
      @AirConAcademy  Год назад

      The liquid refrigerant that is in the accumulator will boil off. Accumulators should not be insulated because we need the heat to get to the refrigerant to make it boil. The compressors are insulated specially when they have a crank case heater, and they are in heat pumps since they run in the winter time. But the accumulator should never be insulated. I hope this answers your question. And thank you for watching!

  • @felixsoto9110
    @felixsoto9110 Год назад

    Love the explanation would 6 oz of PAG in a 8oz capacity system be too much 1995 Impala

    • @AirConAcademy
      @AirConAcademy  Год назад

      Thank you!!!
      I think that is a hard question to answer. Are you replacing the compressor? Did the compressor come empty without any oil? Typically what we do is to measure how much oil is in the compressor when we remove the compressor and then replace only that amount of oil that came out. Usually you do not lose a large amount of oil because of leaks. So the oil should be in the system. You don't want to have too much oil in the system because it will just lay in the evaporator or the condenser and then they're not going to transfer heat like they should. I hope this helps! Good luck!

    • @felixsoto9110
      @felixsoto9110 Год назад

      No compressor change replaced evaporator leaking and will change accumulator

    • @AirConAcademy
      @AirConAcademy  Год назад

      You should not have to add any Oil. You should be able to just change the evaporator in accumulator. Good luck! @@felixsoto9110

  • @nelsongammanpila7454
    @nelsongammanpila7454 14 дней назад +1

    Thank you 👍❤️

    • @AirConAcademy
      @AirConAcademy  13 дней назад

      I'm glad you like the video! Thank you for watching and I have several others that you might enjoy!

  • @swhaircondservice691
    @swhaircondservice691 3 года назад +2

    How about R410A accumulator it is same,cause why generally now r410a using liquids to toup the refrigerant.

    • @AirConAcademy
      @AirConAcademy  3 года назад +1

      Remember, the accumulator is like a safety device for the compressor. It is not there to help you charge a system faster with liquid. To do that you need to throttle the refrigerant into the system so it flashes off long before it gets to the compressor. I have a video that talks about that, you could look for that. Accumulators are typically used on heat pumps because they run under very low temperatures. Be careful when you charge system with a new refrigerant.

    • @swhaircondservice691
      @swhaircondservice691 3 года назад +1

      @@AirConAcademy thanks sir for your answer

  • @AMGpro1992
    @AMGpro1992 2 года назад +1

    Can suction accumulator be installed before screw compressor? Or it is valid only for recip compressor ?

    • @AirConAcademy
      @AirConAcademy  2 года назад +1

      Interesting question, as far as I am aware there are five types of compressors, reciprocating, rotary, scroll, screw and centrifugal. I have only seen centripetal and screw compressors on chillers, meaning they would only be used on large systems and an accumulator would not be needed. The other three, reciprocating, rotary and scroll are used on smaller units. Most of the time when I have seen accumulators they are used in heat pumps. This is done because it is running on your very low temperatures and pressures in the heating mode so most likely they will be liquid trying to get back to the compressor and the accumulator will stop that. I have never seen a screw or centrifugal compressor used in this application. I hope this answers your question. Thank you for the question and thank you for watching!

    • @AMGpro1992
      @AMGpro1992 2 года назад +1

      @@AirConAcademy Thank you very much for your answer. Actually, the system which I am talking about is AC Plant for the ship, it is not a Chiller System. But as I see it can be installed before screw or piston, doesn’t matter. If you have video about how to choose correct sized suction accumulator it would be very good.

    • @AirConAcademy
      @AirConAcademy  2 года назад

      @@AMGpro1992 in your situation I suppose you could install it before the compressor. But it should not be needed if you have a good amount of super heat! And on your system I'm afraid it is too large of a system to have an accumulator? I have never seen an accumulator for a system that large. The most important thing you can do is make sure that you have superheat. Most likely you have TXV's so they should maintain superheat. I hope this helps. Let me know!

  • @Freedyaccountoff
    @Freedyaccountoff 8 месяцев назад +1

    perfect explaination
    thanks

    • @AirConAcademy
      @AirConAcademy  7 месяцев назад

      Thank you very much! I'm glad you liked the video! If you get a chance, check out my website, airconacademy.com and thank you for watching!

  • @wasimedoo7994
    @wasimedoo7994 Год назад +1

    Small question how can you know what type of Freon you put up with out make on the container please help me

    • @AirConAcademy
      @AirConAcademy  Год назад

      I'm not sure I understand your question. But if you have a container of refrigerant, and it is not labeled. You should place it in a room for several hours, once it has stabilized at that room temperature, then you get the pressure and compare the pressure and temperature in the PT chart. That will tell you what type of refrigerant is in the bottle/container. you have to have an accurate thermometer, accurate gauges, and a PT chart. I hope this answers your question. I assume that you're not talking about a specific unit because you could look up the type of refrigerant and the data plate of the unit. But if you're talking about a bottle of refrigerant/container send the way I mentioned is the way to find out what type of refrigerant is in the container. Thank you for watching!

  • @barilelonghana2209
    @barilelonghana2209 3 года назад +3

    Thank you for the clear explanation. Please can you explain a bit how the accumulator affects the flow rate on the suction side of the compressor for a partially evaporated refrigerant. Is it the same as the inlet of the accumulator? or Is it reduced?

    • @AirConAcademy
      @AirConAcademy  3 года назад +1

      They (The manufacturer) have developed hem so here is no pressure drop across them. The pressure should be the same from one side to the other. Thank you for watching and the question!!!

  • @adebowaleadeyankinnu420
    @adebowaleadeyankinnu420 6 месяцев назад +1

    Thank you so much sir. Pls is there any difference between refrigerator compressor and air conditioning compressor?

    • @AirConAcademy
      @AirConAcademy  6 месяцев назад

      Remember one thing. Refrigerators or refrigeration systems will typically use a different type of refrigerant than air conditioning systems. Because of that they will use different oils, sometimes, so you need to make sure that you order or you get the correct compressor for that application. so I guess you could say that there is, or that there are some differences in them. I hope this answers you question. And thank you for watching!

  • @ghostridergr8259
    @ghostridergr8259 2 года назад

    i have one dryer air..
    works 3 to 40 c temp
    i change filter and capillary tube but i haft to resize it...
    so now i have
    -7.5c entry to evaporator and exit 2.5c
    after to the accumulator i have - 3.5 and entry to compressor 9c is that normal.... how much must be the Δτ to the evaporator? and with the temp room so the dryer ro works good??
    thanks

  • @mohamedabujreda453
    @mohamedabujreda453 2 года назад +1

    Hi,
    I would like to thank you for these very good training courses, however; I've seen systems without Accumulator is there a certain conditions and special applications to install Accumulator ?

    • @AirConAcademy
      @AirConAcademy  2 года назад +3

      Yes, most of the time manufacturers will not install accumulators unless it is a heat pump. Typical air conditioning units will not need accumulators because one other things that we do is make sure that we have superheat. Because of the superheat we should not need accumulators in air conditioning units. A heat pump needs an accumulator because of it operating in low outdoor air temperatures. We always run the risk of getting liquid back to the compressor and the accumulator will stop this. This is why we typically do not see them on units. I hope this answered your question! And thank you for watching!

  • @gangemcs
    @gangemcs 2 года назад +1

    Very good overview!!!

    • @AirConAcademy
      @AirConAcademy  2 года назад

      Thank you!!!! and thank you for watching!!!!

    • @yeallen9468
      @yeallen9468 Год назад

      excuse me sir I have a question, as video said there will be more and more liquid refrigerant in accumulator how to handle it, and whether the oil will get into the AC system or just in compressor

  • @udithak9886
    @udithak9886 7 месяцев назад +1

    Thank you so much.

    • @AirConAcademy
      @AirConAcademy  7 месяцев назад

      Thank you! I'm glad you enjoyed the video, check out my other ones and if you get a chance, take a look at my webpage airacademy.com thank you for watching!

  • @periyasammythiruchelvam2139
    @periyasammythiruchelvam2139 9 месяцев назад

    Thanks God bless you

  • @SaresMLee
    @SaresMLee Год назад +1

    Why not all hvac units are installed with this accumulator?

    • @AirConAcademy
      @AirConAcademy  Год назад +1

      quite honestly, I'm not sure!? This would save a lot of compressors, but then again, it cost money to install it. And the manufacturers want to make more money I suppose. These are used in heat pumps because of the low outside air temperature when the heat pump is in the heating mode. Sorry, I guess I don't have a good answer as to why you don't have these on all AC units? Thank you for watching!

  • @r1cky42
    @r1cky42 2 года назад +1

    Thanks for the great explanation you did 👍🏽

    • @AirConAcademy
      @AirConAcademy  2 года назад

      Thank you for watching!!!! Glad you liked it!!!

  • @KarlAlfredRoemer
    @KarlAlfredRoemer 3 года назад +1

    What happens if we turn off the heatpump? Could it not happen that a larger amount of liquid refrigerant runs into the pipe and gets sucked into the compressor when we turn on it some hours later?

    • @AirConAcademy
      @AirConAcademy  3 года назад +1

      That is a good question! If that was to happen it would be a minimal amount and it would not be enough to slug the compressor. Some manufacturers suggest that you have a heater in the accumulator to keep that from happening, but I am sure they would be in very cold climates. And if it's that cold you would not use a heat pump. That was a very good question and thank you for sending it in.

    • @KarlAlfredRoemer
      @KarlAlfredRoemer 3 года назад +1

      @@AirConAcademy Thank you very much. 👍

  • @jegathamir7697
    @jegathamir7697 4 года назад +1

    Absolutely awesome keep rocking

  • @kevinmask8652
    @kevinmask8652 4 года назад +1

    So if a Heat Pump is running next to zero Superheat (bad valve or dirty coil) will the Accumulator prevent Slugging or Washing of the oil from the crank case?

    • @AirConAcademy
      @AirConAcademy  4 года назад +1

      Kevin Mask If your heat pump is running with next to no superheat it could be a dirty evaporator coil, or it could be a dirty return air filter, you may want to check the fan speed of the evaporator fan, check to see if the vents are open throughout the spaces and or a could be a badly adjusted metering device. Bad compressor valves would not cause zero superheat. Yes, you are correct the accumulator would stop the liquid from getting to the compressor, flooding the compressor and destroying the bearings.

  • @tyhamell5425
    @tyhamell5425 2 месяца назад +1

    can any answer on how to drain the liquid refrigerant from the accumulator and pump it back to the receiver. the plumbing and what kind of pump… its a question on my stationary engineer exam

    • @AirConAcademy
      @AirConAcademy  2 месяца назад +1

      That can easily be done by first closing off the king valve, which is the valve on or right after the receiver, then you would close the suction service valve, that should be before the accumulator. When you push the contactor in to make the compressor run, you would boil the liquid out of the accumulator and into the receiver. once you have done this, you can close off the liquid line service valve on the liquid line, which is before the receiver and refrigerant should have gone into the receiver.
      I hope this helps! It is called a pump down procedure.
      Thank you for watching and sending your question in!

    • @tyhamell5425
      @tyhamell5425 2 месяца назад

      @@AirConAcademy thank you 🙏🏾 what kind of pump would pump the liquid refrigerant from the accumulator back to the receiver is the compressor slugging

    • @AirConAcademy
      @AirConAcademy  2 месяца назад +1

      Other than pumping it down, using the pump down procedure, the only way to get it to move around, would be the recovery machine. The recovery machine could be used as a pump to move it from one place to the other. typically it is a pump down procedure. I hope this answers your question. Let me know.

    • @tyhamell5425
      @tyhamell5425 2 месяца назад +1

      @@AirConAcademy thanks i think pump down or evacuating the system with a vacuum pump will be the way to go thank you again

    • @AirConAcademy
      @AirConAcademy  2 месяца назад +1

      @@tyhamell5425 be careful because when you use a vacuum pump, that would not be the correct answer. The vacuum pump would pump whatever is in there to the atmosphere. With a recovery machine, you could move it from wherever over to the receiver. But the correct thing to do would be to pump the system down. So you pump everything onto the high side, including the condenser and the receiver. Whatever is in the accumulator or the evaporator pumped into the condenser and into the receiver...

  • @aaltas
    @aaltas 3 года назад +1

    Great job, Thanks

    • @AirConAcademy
      @AirConAcademy  3 года назад

      Thank you for watching and your comments!!!!

  • @michaelobani1582
    @michaelobani1582 3 года назад +1

    Great video...thank you so much

    • @AirConAcademy
      @AirConAcademy  3 года назад

      Thank you, and thank you for watching! I'm glad you like the video!

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 5 лет назад +2

    So basically both oil and refrigerant will be vaporized into compressor?

    • @AirConAcademy
      @AirConAcademy  5 лет назад

      You could say so the oil will be atomized and go back as a mist so as to not hurt the compressor.

  • @durgaraointuri3592
    @durgaraointuri3592 4 года назад +2

    How to selecte accumulator for equipment

    • @AirConAcademy
      @AirConAcademy  4 года назад

      Typically the accumulator comes with the unit. It is very rare that you will have to add an accumulator to any unit. My suggestion has been to make sure you have the correct suction line size and approximately one that can hold the charge of the unit. Receivers are typically designed and sized to hold the entire charge plus about 10 or 20%. But accumulators typically do not need to hold the entire charge. I hope this gives you an idea. Good luck and thank you for asking and watching!

  • @tantanbernal8244
    @tantanbernal8244 4 года назад +1

    Sir i have a question.. If liquid refrigerant should not enter the compressor.. Then why there is a r410a refrigerant which is applied only in a liquid refigerant state or form? Tnx for the answer. Great video and explanation, tnx a lot sir.

    • @AirConAcademy
      @AirConAcademy  4 года назад +1

      To make the answer short let me say that 410 A is a blend and it needs to be added as a liquid so that the percentages are correct. If we add 410 as a gas the percentages will be wrong and the unit will not operate properly. That is why we have to be very careful when charging a system with 410 A because we do not want liquid to get to the compressor. I hope this explains it. Thank you!!!

  • @DakodaHammonds
    @DakodaHammonds 2 года назад

    Great video thank you

    • @AirConAcademy
      @AirConAcademy  2 года назад

      Thank you for watching! I'm glad you liked the video!

  • @tantanbernal8244
    @tantanbernal8244 4 года назад +1

    Very well said.. Thank you sir.

  • @earthsign28
    @earthsign28 5 лет назад

    I installed a parker accumulator yesterday because the previous one was leaking. I brazed the new one in and pressure tested it and noticed it leaking from the side of the tank. Have you seen this before. Could I have applied too much heat when brazing or could the new one just have been defective?

    • @AirConAcademy
      @AirConAcademy  5 лет назад

      if you over heat the accumulator it could leak but from the joints. not from the side? it could have been defective!!! yes you are correct

  • @ghostridergr8259
    @ghostridergr8259 2 года назад

    what i must make to reduce the Δτ to the evaporator... freon 407c 525gramms
    i put 5 grammas more because the filter was bigger...
    i m not sure if its 530gramms maybe is more or less i dont have good scale....

  • @juandrelouw3172
    @juandrelouw3172 4 года назад +1

    Thanks for help

  • @soterist9011
    @soterist9011 5 лет назад +1

    Hi,
    What means when accumulator is freezing?

    • @AirConAcademy
      @AirConAcademy  5 лет назад +1

      It means that you have liquid refrigerant leaving the evaporator and you need to check the superheat and make sure you have superheat.

    • @soterist9011
      @soterist9011 5 лет назад +1

      Thank u.

    • @soterist9011
      @soterist9011 5 лет назад +1

      @@AirConAcademy Thank u for your answer. If the system had a hot gas bypass line and an extra TXV on suction line should i check something more?

    • @AirConAcademy
      @AirConAcademy  5 лет назад +1

      @@soterist9011 OHHHHH!!!! That changes things a bit!! it could be that the hot gas bypass valve is not opening and the TXV is miss adjusted. those systems are a bit more tricky. check the adjustment on the extra TXV. sometimes those have a solenoid just before it so it only works sometimes. only when needed. so check the superheat on the extra TXV. I am sorry it took me so long to answer I have been teaching in the mornings.

    • @fabiodarocha2842
      @fabiodarocha2842 4 года назад

      Cai have an accumulator in the every unit or just heat pump?

  • @kaustubha7371
    @kaustubha7371 4 года назад +1

    Thank you soooooo muchhh sir.

  • @hasanulmuslim6276
    @hasanulmuslim6276 5 лет назад +1

    Pls do the video about flash tank

    • @AirConAcademy
      @AirConAcademy  5 лет назад

      I will make a note of it and get one on here soon Thank you!!!

  • @irham9856
    @irham9856 Год назад +1

    👍👍👍

  • @matttzzz2
    @matttzzz2 2 года назад +3

    He held up that thing in his hand and said "an accumulator" and I'm thinking "bro that's not an accumulator, how can all the refrigerant in a system fit in that thing in your hand"....then he started writing with it and I realised that is a pen. I am not a smart man

    • @AirConAcademy
      @AirConAcademy  2 года назад +1

      lol these comments make wonder how I can improve my videos and how what I say and do may be seen differently by others!!! thanks for your comment!!! and thank you for watching !!!!

  • @jhuh1758
    @jhuh1758 4 года назад

    Very Clear! thank you

  • @wd8557
    @wd8557 3 года назад +1

    How can you tell if a Accumulator is bad. Let's assume everything else is correct.

    • @AirConAcademy
      @AirConAcademy  3 года назад +2

      That is an interesting question! There is actually not much that can fail in an accumulator. The only thing that could happen is that the port at the bottom of the RUclips could get clogged up. Other than that not much can fail. The only thing I have seen happened that makes you need to replace an accumulator is that they rust and they leak. They are made out of steel so patching it is not going to work. I have tried that before and a few days later another hole appears someplace else. But there isn't anything that could actually feel in an accumulator. I hope this helps! Good luck out there!

    • @wd8557
      @wd8557 3 года назад

      @@AirConAcademy Thanks