  • This is for testing if a 24-volt thermostat is bad. These are the steps you should take in order to verify that it is the thermostat that is bad and not the wiring or control board. When you make sure that the power is on to the unit, the light (if there is one) is lit inside the HVAC system and nothing happens when you turn the thermostat on then this video is for you. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • Top 12 Problems/Mistak... 10
    • Thermostat Wiring Diag...
    • Thermostat Wiring to a...
    • Thermostat Wiring & Re...
    • Thermostat, Furnace, A...
    • Thermostat Wiring & Re...
    • Heat Pump Thermostat W...
    • Wiring a Thermostat, F...
    • How to Test a Heat Pum...
    • Wiring a Heat Pump The...
    • Heat Pump Thermostat T...
    • Understanding and Wiri...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicet...
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicet...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtoo...
    Refrigerant Charging Book and E-Book: www.acservicet...
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicet...
    Our Newest Articles: www.acservicet...
    Try our HVAC/R Quizzes! www.acservicet...
    Our Other Resources: www.acservicet...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicet...
    Our Tool List on Amazon: www.amazon.com...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtoo...
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.c...
    Apple Podcasts: podcasts.apple...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #oil #thermostat #problem #top10 #hvacthermostat #hvactips #hvacproblems #thermostats
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Комментарии • 372

  • @acservicetechchannel
    @acservicetechchannel  7 лет назад +7

    Our Inverter Mini Split Resources:
    Mini Split Book on Our Website- www.acservicetech.com/mini-split-book
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGuides?aff=8
    Mini Split E-Book on Google- play.google.com/store/books/details?id=HN-iEAAAQBAJ
    Mini Split E-Book on Apple- books.apple.com/us/book/id6445178399
    Our Single Speed and Two Speed Air Conditioning Resources:
    My Paperback and E-Book: www.acservicetech.com/the-book
    My Paperback: www.amazon.com/shop/acservicetech
    Read the book reviews on Amazon!
    Check out our new Articles at www.acservicetech.com/articles
    Support the Channel by purchasing tools through Tru Tech Tools!
    Use this link www.trutechtools.com/?Aff=8
    Save 8% at checkout using code "acservicetech"
    My Service and Procedure Book- www.acservicetech.com/the-book
    Tool List- www.amazon.com/shop/acservicetech
    Support- www.patreon.com/acservicetech
    For those that are looking for the tools used in the videos: (Linked Below)
    UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ
    Magnet Jumpers- amzn.to/2PyKPQZ
    Alligator Jumpers- amzn.to/2PxqJXn
    Fieldpiece ST4 Dual Temp Meter amzn.to/2wc1ME3
    Fieldpiece Bead K Type Temp Sensor amzn.to/2DBwKfs
    Fieldpiece Wet Bulb Temp Sensor amzn.to/2RRI7Tw
    Fieldpiece TC24 Temp Clamp amzn.to/2qHLyjZ
    Yellow Jacket Refrigerant Gauge Set amzn.to/2aenwTq
    Refrigerant hoses with valves amzn.to/2aBumVI
    Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9
    Yellow Jacket 4 Port Manifold w Hoses amzn.to/2BkuGIq
    FieldpieceSMAN360 Digital Manifold Set amzn.to/2BdoaD4
    FieldpieceSMAN460 Digital Manifold Set amzn.to/2nB4Fe6
    Compact Ball Valve for Refrigerant Hose amzn.to/2KUisW8
    QuickDisconnect 90 for refrigerant hose amzn.to/2MMtVcg
    JB 6 CFM Vacuum Pump amzn.to/2nqbvo8
    Appion Blue 3/8" to 1/4" Vacuum Hose amzn.to/2uYlVyc
    Appion Red 3/8" to 1/4" Vacuum Hose amzn.to/2uYg6Ro
    Appion Valve Core Removal Tool amzn.to/2uYr8WL
    Yellow Jacket 1/4" by 1/4" hose amzn.to/2umtcod
    CPS Vacuum Micron Gauge amzn.to/2v1nM3O
    Supco Vacuum Micron Gauge amzn.to/2v1JRiA
    RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn
    UEI DL389 Multimeter amzn.to/2xAdaJf
    Air Acetylene Torch setup amzn.to/2aQalsb
    15% Silver Brazing Rods amzn.to/2gVLyLc
    Nitrogen Regulator amzn.to/2bXdR5f
    Nitrogen Flow Meter amzn.to/2brvoBg
    Other tool links can be found in the video description section.
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech

    • @inquisitvem6723
      @inquisitvem6723 7 лет назад

      so before i do anything, i should shut off power to house right? so i dont get electrocuted? then open the panel display? I have a honeywell CT500 that goes blank every so often and now not generating cold air...i have a brand new AC unit too. it has no batteries, so that cant be the problem. i also reset the circuit breakers and the display panel of thermostat still goes blank and then re-appears. it does this every few minutes or so. is it a problem with the wire connection of thermostat? is it loose?

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад +1

      I recommend calling a tech but they would shut the power to the hvac system off and take the tstat face plate off and tighten the connections on both ends, in the thermostat and in the furnace or air handler. After that they will check for 24v to the thermostat and if they have it then it is a bad thermostat. It could also be one of the pins not aligning on the back of the thermostat.

    • @inquisitvem6723
      @inquisitvem6723 6 лет назад

      did u power off the thermostat? i see nothing on the panel at the beginning of vid.

    • @darrylchappell3440
      @darrylchappell3440 6 лет назад

      How to replace thermostat for boiler heater

    • @darrylchappell3440
      @darrylchappell3440 6 лет назад

      How to replace thermostat for boiler heater

  • @terencechan7338
    @terencechan7338 4 года назад +25

    Thank you for saving me a costly service visit! Your suggestion of tapping the R and G wires helped me confirm a bad thermostat! Thank you for taking the time to produce easy to follow instructional videos with detailed explanations that don’t require hvac training to understand!

    • @acservicetechchannel
      @acservicetechchannel  4 года назад +1

      Glad it helped!

    • @sandrarichardson2713
      @sandrarichardson2713 2 года назад +1

      Hi---It looks like you understood what he said about the red and green wire. Did he say the thermostat is bad if the fan DOES come on when touching the red and green wires together or if the fan DOESN'T come on? Thanks for your help. Jesus bless.

    • @terencechan7338
      @terencechan7338 2 года назад +2

      @@sandrarichardson2713 Hi! He said if the fan turns on when you jump the R and G, then the faceplate/thermostat is bad. Good luck!

  • @cozmicmojo2181
    @cozmicmojo2181 4 года назад +28

    For anyone who's control panel is working and whose unit is fine but doesn't seem to be sending data: If continuity from the screws to the copper is good, look at the AC unit's circuit board and check the fuse(should be purple or amber). I accidentally blew it somehow when moving the thermostat. Easy fix!

    • @aureannanicole3477
      @aureannanicole3477 2 года назад +3

      Thanks! You saved me so much time. Couldn’t figure out what my problem was!

  • @vetdadcubby4722
    @vetdadcubby4722 8 лет назад +8

    Awesome, I just completed tech school last fall and I'm working for an HVAC contractor! ALWAYS learning!

    • @acservicetechchannel
      @acservicetechchannel  8 лет назад +1

      Great to Hear and in this trade, we all will always be learning! Keep it up because over time you will move up the ladder right past those that stop searching for answers and learning new things! Thanks

  • @frustratedmechanic6263
    @frustratedmechanic6263 7 лет назад +5

    The best instructor on RUclips... he makes it so easy to understand.

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад +1

      Thank you very much Dwayne Wallace! I am glad you appreciate the video!

  • @binjagav2053
    @binjagav2053 Год назад +2

    My man!!!!!!!! After I changed almost everything in the furnace, not works until I did the test G and R and the thermostat was bad . Now my furnace work like 7/11 store non stop. Thank you so much bro

  • @tilnoenecp704
    @tilnoenecp704 2 года назад +20

    *Easy to assemble **Fastly.Cool*

  • @davidfc1985
    @davidfc1985 3 года назад +7

    I just solved my problem with my 1950"s Lennox Furnace with this video. Thank you for all the great videos!

  • @willlove7927
    @willlove7927 6 лет назад +16

    Thank you I’ve literally watched atleast 2 videos every day and I’ve become a better tech because of you thanks a lot I have to get better at gas furnaces and diagnosing electrical issues

  • @DaBuick
    @DaBuick 5 лет назад +3

    I’m having intermittent thermostat issues. Going to replace it tomorrow am when the store opens. I appreciate the video, it confirmed what I had done.

  • @leo33125
    @leo33125 Год назад +4

    i enter youtube to look for thermostat problems, cause i got a service call for tomorrow, boom this video give me all i needed. ty

    • @yuyuyu9029
      @yuyuyu9029 Месяц назад +1

      Looking at this video while doing a service call lmaooo

  • @melvin292
    @melvin292 7 лет назад +7

    Great video and a good explanation of why the industry moved away from the old mercury switch. Those switches would bounce those compressors on and off until the mercury settled. A five minute delay is a bit long but better safe than sorry.

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад

      Yes if I need to turn it on quickly then I use the mag jumpers, otherwise I have time while doing other maintenance, Thanks

  • @st.charlesstreet9876
    @st.charlesstreet9876 Год назад +3

    The explanation and demonstration is so very clear and Very much appreciated, Thank You!

  • @madurasenju2015
    @madurasenju2015 5 лет назад +4

    I been seeing your videos for 2 years before I became a tech , and even now I always see them and learn dude . Ur a great teacher , I can only image how your helpers or family members who are intrested in the trade turns out to be man . Thanks and please always keep uploading more videos .

  • @cassondrad2280
    @cassondrad2280 5 лет назад +10

    Awesome. Girl Power. You helped me figure it out. I GOT HEAT. I so refused to call service man. I knew if air conditioner worked and I tested just like you showed to boot the fan, then I knew it wasn't the furnace. I have where red wire could go either to RC or RH, it was at RC so I hooked red to RH and I got heat. Thank you

    • @GomezTavo
      @GomezTavo 5 лет назад

      I have RC and RH. How did you test the thermostat?

    • @AK99581
      @AK99581 5 лет назад +3

      Even though you now have heat, that's not really the proper way to do that. You shouldn't have to constantly switch your live wire over every time you want to switch between heating and cooling. If you only have one red wire coming in from furnace control board, it should be hooked into the RH terminal, while a separate jumper wire should be connected between RH and RC.

  • @erics9213
    @erics9213 7 лет назад +16

    Before jumpering the R and G, I would use a multi-meter and check for 24V A/C between the R and C.

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад +5

      Yes, sometimes there is no C to test from though, thanks Eric S!

    • @AK99581
      @AK99581 5 лет назад

      @@acservicetechchannel Was just going to say, that method wouldn't do you any good for a thermostat with batteries..

  • @AlphaGolf1
    @AlphaGolf1 4 месяца назад +1

    I had a call where the AH was running but the condenser was not. I had no voltage between C and Y at the control board outside or the AH. Pulled out the Tstat and jumped between R and Y and the system came on. Tstat was bad.

  • @robertnieves5848
    @robertnieves5848 7 лет назад +9

    Thank you, I was able to fix my AC problems using this video, thanks for taking the time

  • @MrRasgabriel
    @MrRasgabriel 8 месяцев назад

    Thank you so much for helping me bring heat back to my home for my family!

  • @williamowen9528
    @williamowen9528 Год назад +1

    This video was a BIG help! Thanks for posting it!

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices6926 2 года назад

    Another way I have done it. I used the pins on the back of the thermostat battery operated type. Call for blower the pins should ohm out. Same thing for calling for heat. Make sure you are connecting to the correct pins because they are not marked you have to reference how the pins plug into the back plate.

  • @armenlock9619
    @armenlock9619 7 лет назад +2

    So clearly explained and helpful. Thank you so much.
    Lets me know if I should call our utility that installed the energy saving thermostat or if it's time to call an AC tech without wasting his time or mine.

  • @joshr9358
    @joshr9358 5 лет назад +4

    Great video! It is to the point and easy to understand. Thanks!

  • @jochute
    @jochute 6 лет назад +3

    Thank you so much for a concise clear video on troubleshooting.

  • @stephenzoll4597
    @stephenzoll4597 3 года назад +2

    What’s wrong when the thermostat works on fan only ? When put on auto the ac and the heat don’t work. It does nothing, no sounds or anything

  • @libertyfox7486
    @libertyfox7486 3 года назад

    Good Stuff, My pro TH8000 on Cool or fan, the heater turns on. This test should expose issue that I believe is 25 yr thermostat

  • @darinz182
    @darinz182 4 года назад +5

    Thank you for sharing your knowledge brother ! You’re a great Teacher and Tech!

  • @Robginski
    @Robginski Год назад +1

    If the heating works and ONLY the A/C won't work, what is the most likely culprit? The thermostats display is fine, as is heat. Do you have a video to diagnose A/C only? I think the fan is fine since heating is working.

    • @rabdhall05
      @rabdhall05 Год назад

      Thermostatic expansion valve(TXV hvac)? I've learned that when they fail, that the heat can still work; they are designed to fail that way(generally speaking), so you'll still have heat if it were to happen in extreme cold season.
      Might not be of any help to you; just thought I'd suggest in case you're still in need, being it came to mind when I read your comment.

  • @stephfong4577
    @stephfong4577 3 года назад +1

    A service guy came and told me the first stage heat pump does not work because he could not feel the heat when touching the tube. Do you have a video to check which heat pump has problems in the two-stage electric AC+furnace system?

  • @acservicedaytona386portora3
    @acservicedaytona386portora3 7 лет назад +12

    Again another great video...

  • @geojor
    @geojor 5 лет назад +4

    very practical video, thank you ...

  • @koolmodee4542
    @koolmodee4542 7 лет назад +1

    Thanks - just tested mine and it was, indeed, the thermostat - fixed and back to cool for $25.

  • @jasonharris120
    @jasonharris120 10 месяцев назад

    This helped me out tremendously! Thanks alot

  • @HsingSun
    @HsingSun 2 года назад +1

    Thank you very much for your video. My system was keeping running when both inside and setting temperatures are matched, what is caused the problem inside the air-handler, need help?

  • @acedogg692005
    @acedogg692005 Год назад

    I know this is an old video but, I only have a red and white wire going to my thermostat. When I turn the heat on for my thermostat the boiler runs for a while and then shuts off. A couple minutes later it kicks back on and so on. It just keeps running like that no matter what the heat it set on. You can have it set to 60 and the temp will keep climbing...We've replaced the thermostat with the same one like three times and still get the same outcome. I just turned the boiler off and touched the red and white and turned the boiler on and it kicked on. I've had a couple people look at it and nobody has an answer.

  • @justinsanders6276
    @justinsanders6276 2 года назад +5

    What causes the ac to keep running when thermostat temp reaches but it’ll cut off at night when outside temp cools down?

    • @victorrojas7071
      @victorrojas7071 Год назад

      For residential home with local thermostat. Possibly a schedule for the cooling on the thermostat.. 1 yr later and no one could comment their best guess. Comments are greatly welcome

    • @victorrojas7071
      @victorrojas7071 Год назад

      The ac with cold air keeps running after reached setpoint? If just fan is running blowing normal return space temp air, then blower probably has a schedule. Or the contacts themselves are bad in the thermostat and the unit shuts down late at night due to low pressure/ low limit with cold outside air. Then resets the next day

  • @Markvdubr32
    @Markvdubr32 Год назад

    If I’m jumping power to check the heating operation I always add the fan into the jump beacause I don’t want any thermal overloads to burn out by turning the heater on without the fan running

  • @How2FromAP
    @How2FromAP 5 лет назад

    Thank you for this video, the logical path you have laid out, though not exactly the issue I had, it helped me draft my own plan and it helped me diagnose my issue. I was getting 24V at the thermostat, and at the circuit board at the air-handler in my basement. I can hear the thermostat click when I switch to AC or Heat. Heat came-on (this was summer and 80 F Day so I had to set the thermostat to 82 or something to get it to work, but it worked, the AC however did not. Knowing that I got 24V (my meter showed about 27v), so I knew volts should be going out to condenser outside. But the condenser did not start. I saw no 24V at the contactor. I pushed the contactor and it started, condenser and I held it there for a few minutes and family inside confirmed getting cold air, so I knew no issues with the condenser/ compressor. So basically the issue was between the wire that came out of air-handler to the condenser outside. I started following the 24V wires from the contactor to the wall, and I found the issue. I should have looked for this as soon as I found a mice nest in the condenser, they had chewed one of the 24V wires and thus contactor did not get the juice it needed to kick-in the condenser. Once I patched the wire, everything was working again.
    I have seen folks ask where to buy some of the electrical parts (Contactor, Transformer, Capacitor, etc.) I found these on-line, but you have to wait for a few days, alternatively if you need one quickly I was able to buy at Grainger that is not too far from me, and a GPS (General Plumbing Supply) they had some of the parts I needed as well. This is just an FYI.

  • @ricter591
    @ricter591 3 года назад +1

    Thanks Helps a lot.

  • @titanicsauce2152
    @titanicsauce2152 4 года назад +2

    I learned alot. Thank-you!

  • @themaz6802
    @themaz6802 5 лет назад +2

    First than everything thanks for the video well explained .. My friend I put the thermostat at 83 this morning and it shutoff all the sistem now it won't start. and nothing in the screen I put new batterys and nothing.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +2

      Did you check to see if you have 24v on the indoor unit from r to c? It is possible the power at the indoor unit is off or fuse is blown, thanks

    • @themaz6802
      @themaz6802 5 лет назад

      Yes I do the thermostat was the problem. I buy another one of the same i just put the new in it problem solved..thank you very much for your help.🙏🙏👍👍

  • @joseph-ine452
    @joseph-ine452 8 месяцев назад

    Outstanding. Great work

  • @Eddy63
    @Eddy63 8 лет назад +1

    Awesome video. Good teaching tool ...please keep up the good work ...

    • @acservicetechchannel
      @acservicetechchannel  8 лет назад

      Thank you very much!

    • @jaelin38
      @jaelin38 6 лет назад

      acservicetech I have a White Rodgers thermostat that is not working right. I have no control of the temp settings. I touch up or down arrow it goes to 90 by itself. Heat kicks on and run for maybe 2-3 minutes and drop to 62 and eventually cuts off. Is tstat bad? Please help me

  • @Lemurian.Quartz
    @Lemurian.Quartz Год назад +1

    Is there a follow up video of what to do if this doesn’t work?.. I recently got a new condo.. I installed a “smart thermostat” by EcoBee. It worked fine for a few months but then suddenly stopped. I’ve flipped all breakers, I tried the things in this video.. what is weird is that since it is smart, it will send me notifications when it turns on about the temperature. I will be at work, and out of nowhere (nobody lives in my condo than myself and my cat) it will turn on for like 20 minutes and then go off again..

  • @Volusiaev
    @Volusiaev 3 года назад +1

    If you need heat in an emergency, would you have to connect the three wires (r g w) altogether? Or will just jumping the r & w work?

  • @andrewskerbitz1358
    @andrewskerbitz1358 5 лет назад

    Thank you! Info helped diagnose the thermostat.

  • @TheJesse7647
    @TheJesse7647 Год назад +1

    Do you have anything that shows what wires should be connected at the furnace from the thermostat to the fan motor ?

  • @MrCeora
    @MrCeora Год назад

    My furnace wouldn't turn on, and I realized that the problem started after I had changed the thermostat batteries. Checked the thermostat wiring and thought that the excess dielectric grease that was on the male and female terminals was causing a problem, then realized that because of the awkward location where the thermostat
    was mounted, that the display portion of the thermostat hadn't fully seated all the pins. If you didn't look at it closely, you couldn't see it wasn't seated.all the way It allowed me to run the fan, but not run anything in auto, therefore no call from the thermostat. Motto: Make sure the face plate is fully and evenly seated.

  • @miketreat
    @miketreat 7 лет назад +2

    Great video. Thanks for the help

  • @kelleewilkerson6822
    @kelleewilkerson6822 5 лет назад

    Sure is hot in here this summer but im going to miss these low electric bills once i do get the ac fixed one day. Big difference in 250+ per month and 30-40 per month!

    • @stillmatic03
      @stillmatic03 5 лет назад

      Last night was only night 3 for me.. running the fan on myself wasn’t so bad even though it was 86 in here (Florida)

  • @girohead
    @girohead 3 года назад +1

    Excellent tutorial. I asked a guy years ago how he knew the tstat was failed, he said, 'I jumped it' and I assumed but didn't know that meant (esp with multiple wires, and why). It makes sense if something is simply not turning on. If it starts/stops w/o hitting temp, I assume that is on furnace side?

  • @mikewhite7608
    @mikewhite7608 5 лет назад

    thanks this video helped us at our home

  • @oscarpena7259
    @oscarpena7259 4 месяца назад

    Thanks a lot

  • @taz200032
    @taz200032 2 года назад +1

    I appreciate this video man. I'm relatively new to the trade so thermostats always scared me lol

  • @ferminrosa9620
    @ferminrosa9620 Год назад

    Thanks very useful ❤️🙏

  • @vausa1000
    @vausa1000 4 года назад

    Thanks much. Helped a lot.

  • @carybodiford4730
    @carybodiford4730 10 месяцев назад

    Very helpful,,,thanks

  • @human-sn7lk
    @human-sn7lk 2 месяца назад

    I have a 2 wire Carrier edge thermostat- any way to test that?

  • @Dave-um1hl
    @Dave-um1hl 3 месяца назад

    Hi. The screen on my thermostat is blank. I replaced batteries, nothing. A couple days was back on. Now blank again…but, if I press the temperature up, it comes on (not the screen, the furnace). Also, if I turn fan on it comes on. Any ideas 💡. Thanks so much.

  • @barryward192
    @barryward192 3 года назад

    Do have to turn power off for to see if fan come in

  • @ganeshkanchari3997
    @ganeshkanchari3997 3 года назад

    Thanks

  • @chickedwin7194
    @chickedwin7194 5 лет назад

    Believe or not sir, you are the best

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +1

      Ha ha, thank you very much Chick. I am glad you enjoy the videos!

    • @chickedwin7194
      @chickedwin7194 5 лет назад

      @@acservicetechchannel Sir pls i need your help. How do you check sub cooling on a mini split with no service valve on the liquid line. Thanks in advice

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +1

      So if the minisplit is a vrf then we the manufacturer usually doesn't give us any charging guidelines for it. What I have found though is that in cooling mode when the temp was above 70 degrees, many systems operate at 0-5 degrees of superheat on the full speed emergency cool call. The only reason that they function like that is so the saturated state is arger and they use the accumulator to protect the compressor. In normal units, low superheat would be a big problem for the compressor. The manufacturers just want us to use the total weight method for checking the charge which is a complete recovery, pressure test, find and fix the leak, pressure test again, vacuum, break the vacuum with the total amount of refrigerant that the system says it needs per the rating plate plus additional line set length, thanks

    • @chickedwin7194
      @chickedwin7194 5 лет назад

      @@acservicetechchannel great

  • @DrSolo-qb1ze
    @DrSolo-qb1ze 14 дней назад

    Hello Craig. I was working in the field and ran across a thermostat that the voltage on the R and Y was 16 volts, it also showed 16 volts in the air handler and 16 volts in the condenser. Testing the Red with green, and Red with white both registered 27 volts. What could be causing the voltage drop? The contactor does not show any voltage on the coils, but when testing the coil for ohm it shows 12.8 ohm and it also has continuity. The contactor is not sucking in at all. What could be the problem? Thanks for your input.

  • @chingonyayo
    @chingonyayo 4 года назад

    Thanks for the awesome video bud!!

  • @donnierobertson3088
    @donnierobertson3088 3 года назад +1

    Nice

  • @draugami
    @draugami 3 года назад +3

    My thermostat is set for 60 degrees at 3 am. The thermostat still runs at 68. Is the thermostat unrepairable? How long does a thermostat last? 10 years?

  • @Colt-wr6wx
    @Colt-wr6wx 5 лет назад +5

    Good video. But there are alot of different thermostats. This one is the easiest to work on.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      Thanks Colt 45 zag!

    • @Colt-wr6wx
      @Colt-wr6wx 5 лет назад

      @@acservicetechchannel thank you. I refer back to your videos just to refresh my mind sometimes. Always good in detail! 👍

  • @dubbya57
    @dubbya57 4 года назад

    The only way to get my heater to kick on is to change the fan selector from AUTO to ON. Then when the desired temp is reached I change it back. But then it wont kick on again when the temp drops. Should I just replace the thermostat?

  • @robertomurri1278
    @robertomurri1278 5 лет назад +1

    I have a question if you don't mind answering it. I have a Honeywell thermostat, and it would blink like the thermostat was about to turn off completely. So I switched the coin cell battery and when I put the front plate back on to the back part mounted on the wall. I waited for it turn back on, and I put the cool air to auto and on 65. The fan never came on tho, and even when I bring it down to the lowest temp. It would still say "Cool On", but nothing. What could it be? Should I do what you did in the video?
    I did turn the breaker switch to Off, and then back On and it worked for a min then it shut off. Smh.

  • @antoinewong5539
    @antoinewong5539 8 лет назад +1

    At 4:48 you said if the fan not come on do you mean fan blower or condenser fan?

    • @acservicetechchannel
      @acservicetechchannel  8 лет назад +1

      Thanks for the question. I am referring to the blower motor only turning on. Thanks

  • @christophermoore9897
    @christophermoore9897 2 года назад

    So if you jump the 24v wire to the g wire and it turns on (thermostat is set to auto not fan), that means the thermostat is bad ?

  • @aron352352
    @aron352352 5 месяцев назад

    The fan? The blower or condensor fan?

  • @luisausay2462
    @luisausay2462 7 лет назад

    thank you very much SR. you are the man!!!

  • @mikellandrum6673
    @mikellandrum6673 Год назад

    Any idea what would cause the blower motor to blow harder once I removed the jumper wire to diagnose the thermostat. My blower kept blowing for about 20 seconds after I pulled the jumper wire and it blew harder than it did when thermostat was working

  • @lexus3577
    @lexus3577 2 года назад

    When you say fan, are you referring to air handler fan or compressor fan? My AC is not getting 24V at contactor to turn on compressor and compressor fan but air handler fan is working. I'm getting 24V b/w R and Y, R and G, R and W on thermostat. When thermostat calls for cool, G and Y goes from open to shorted (connected). So the thermostat is working fine, correct?

  • @fftl1827
    @fftl1827 6 месяцев назад

    So my AC and fan work yet my heat (propane) does not. I did the red and green as you instructed and the fan ran so could this be the reasoning behind my heat not working properly? Does this also cause short cycling?

    • @fftl1827
      @fftl1827 6 месяцев назад

      If I wanted to check the heat I guess I would have to jump the Red and White?

  • @melindamanthey2757
    @melindamanthey2757 4 года назад

    The furnace is a TRANE TWV 025 B140A1 May 1994. The problem is no heat. The thermostat is an older mercury switch RHEEM. I would like to check the thermostat for continuity for heat. In the video you say to jumper red to white to check for heat , but how is this done if the green wire cannot now receive power so no fan, no way to check heat from the vents. Confused and would appreciate any advice. BTW cannot find any low voltage fuse for the transformer. ... supposed to be a 3.1 AMP... cannot locate. Shows on the legend, does not show on the schematic. Additional info. Installed a Honeywell non programmable thermostat as suggested by Honeywell. Could not correctly program and they were less than helpful. Re-installed the RHEEM mercury Thermostat. Same condition. Also replace Time delay fan manger.. Limit switch checks ok. This is why we suspect the T'Stat. Do you concur this may be the T'Stat ? Or? Baffled. Thanks.

  • @charolito1312
    @charolito1312 6 лет назад

    Great video... thanks

  • @debotoed
    @debotoed 6 лет назад +1

    Hi and thank you for your videos. I have tried extensively to troubleshoot my thermostat issues but to no avail. The electric furnace works, in so far that if I switch it off from heat to off. If I don't it will just continuously run. I am beginning to wonder if it is a wire issue between thermostat and furnace, as I have replaced the thermostat 4 times in past 5 years. (with same thermostat rth 221). However this year it is not responding to program or hold function. I have five wires coming out (red, white, green, black, and orange.) I don't have pump so orange not in use. I am not sure if relevant but the program and hold feature do work if I remove black wire, but there is no heat when operating with this configuration. Thanks

  • @bryanhauschild4376
    @bryanhauschild4376 Год назад

    Do you have a video if the fan Doesn’t come on, where to look next?

  • @jerrodwilliams6789
    @jerrodwilliams6789 5 лет назад

    I have a rookie question for ya. I have two Lennox units in my house. The upstairs one is 2.5 tons and the downstairs is 2.0 tons. Why is it that the 2 ton outdoor unit is larger than the 2.5 ton outdoor unit? The 2 ton unit calls for 16 degrees subcool and the 2.5 calls for 6 degrees.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      The 2 ton is likely a higher SEER rating than the 2.5 which means it is bigger to be more efficient in terms of heat exchange on the coils, thanks

  • @0MissElizabeth0
    @0MissElizabeth0 2 года назад

    Baahahaha turns out mine just had dead batteries with corrosion on one of the terminals! LOL

  • @The-Homecook-0000
    @The-Homecook-0000 4 года назад

    How about if the batter is running low would that make it not read right

  • @thefreshride1510
    @thefreshride1510 2 года назад

    Good

  • @seshachary5580
    @seshachary5580 6 лет назад

    very educative thank you. regards

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад

      Thanks Sesha!

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад

      Sesha Chary, I am very appreciative that you chose to Support the ongoing work of AC SERVICE TECH through Patreon! Feel Free to email me any questions you may have at info@acservicetech.com also let me know what questions you would like answered or shown in the quarterly Insider video, thanks!

  • @nld-bl5ct
    @nld-bl5ct 2 года назад

    My Lennox Air Handler CBA 27 fan will not come on on circulationg "ON' setting since it was installed 3 years ago. Just running AC from my attic. Would like to circulate the fan all the time. I have even changed out the thermostat. Any thoughts?

  • @thatguyinthathat.s6969
    @thatguyinthathat.s6969 4 года назад

    I just have a red and white wire. I only have heat so that should explain it, right? My panel “works” meaning it can be set etc, however it has no impact on the furnace. If the heat is on it keeps staying on... and temp keeps rising. Any suggestions?

  • @vetdadcubby4722
    @vetdadcubby4722 8 лет назад

    To the point and direct, great job keeping it simple!

    • @acservicetechchannel
      @acservicetechchannel  8 лет назад

      Thank you very much, glad you enjoyed it! Here is the playlist for thermostats if interested----ruclips.net/p/PLxnHR5_D2ojzDfU1IjPpzdhi_mUGe3F7W

  • @vjnblnum2303
    @vjnblnum2303 5 лет назад

    Thank you sir

  • @jimmyung3212
    @jimmyung3212 7 лет назад

    Thank you!!!

  • @carlitosducoing8507
    @carlitosducoing8507 11 месяцев назад

    So where is the thermostat located ?? Mine rums for 8mns cool..but fan stays on forever

  • @denniszehner1380
    @denniszehner1380 3 года назад

    I just put in a new condensate pump. Pretty simple. Turn off the power, unplug the old little giant and remove. Install new little giant, plug in and power up. Problem is that after doing this I have no power to the thermostat. I jumped the fan but it doesn't run. It's a tempstar and I don't believe there is any reset switch. I have checked fuses and breakers and all are good. I filled the reservoir and the pump works. The pan is not switched for water. The fan just hums. I checked the capacitor and it shows 7.3. Any idea where to look next?

  • @xhacu9625
    @xhacu9625 2 года назад

    For some reason. On my Goodman single stage furnace. I jump r with the A/C and it works. But my heat and fan don’t. Any reasons on why?

  • @thulkifl336
    @thulkifl336 7 лет назад

    great info

  • @jerrodwilliams6789
    @jerrodwilliams6789 5 лет назад

    also If the reversing valve solenoid was beginning to short out would it fry the defrost board or the thermostat? its a lennox 13hpx-030-13

  • @ricardosotobarraza3715
    @ricardosotobarraza3715 3 года назад

    I’m reading 24 volts between R&Y , R&W , but only 12 volts between R&G. Could it be a transformer issue? Or a short on the G ?

  • @tomdonald2495
    @tomdonald2495 6 лет назад +1

    ok now it makes sense

  • @trinaparker9454
    @trinaparker9454 5 лет назад

    Went through severe storms and had a big power surge several times. The unit wouldn't come back on and since it was cool weather I thought it was just the heat but it's the ac also. I have power to the unit and the tstat has it's digital readout but I switched from off to ac and nothing happens. So no heat and no ac and I really need my ac it was 95 in my house last night. Thanks for any help.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      Did you connect the r to the g to see if the fan would come on? Is it possible the thermostat has battery power but not 24v at the r terminal. The fuse inside the furnace may have popped or the switch or breaker may be off to the furnace, thanks

  • @brendandrury2177
    @brendandrury2177 4 года назад

    My 1-year-old system does not cool off. The repair guy today checked thermostat buttons. Furnace made noise. Fan outside made noise and turned. He left happy but after 2 hours my system did not drop house temp (no cooling) from 78 degrees to my setting 74 degrees. Instead it increased 1 degree to 79. The a/c company doesn't believe me. I have to go up to the house again and I asked for another a/c guy. Any thoughts???

  • @56rmax
    @56rmax 5 лет назад

    Do you have a video on testing the thermostat wiring for shorts and or breaks?

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      Yes I do believe. Look through the "acservicetech Thermostat Troubleshooting Playlist" for the videos there, thanks