Tried Something New & Took Twice As Long But Was It Worth It?

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024

Комментарии • 124

  • @WilliamMulligan
    @WilliamMulligan 3 месяца назад +14

    That was a gorgeous CU install. The most impressive bit was the square cutting of the trunking.

  • @matthewwallace7751
    @matthewwallace7751 3 месяца назад +1

    For your kinnetic socket. Build a little board with a socket feeding off a contactor and use the kinetic receiver inline with the coil.

  • @Weuffel
    @Weuffel 3 месяца назад +1

    Milwaukee has an adapter to use with any hoover. its called 0950-20, Wireless Dust Control Adapter & Remote Kit.

  • @nigelsmith7955
    @nigelsmith7955 3 месяца назад +2

    We have a remote power switch here in the US normally used for turning on dust collectors remotely, I use one on my vac as well, it just plugs in between the plug and socket! I think they have similar in UK plug format for dust collector as well

  • @tomstovell7425
    @tomstovell7425 3 месяца назад

    Lovely job again Nick. I do enjoy watching your board swaps and rewrites in general. Really neat and you always give 100% when it comes to attention to detail.

  • @nathanaddison9778
    @nathanaddison9778 3 месяца назад

    Board looks neat but the cable tied gas bond is a no no NIC pulled us up for that years ago
    Also we have to firestop everything now , straight from the board up the trunking and into the loft or floor above is also a no no

  • @edc1569
    @edc1569 3 месяца назад +3

    Nice job! Zero ring finals, like that!

  • @MikaMikaMika89
    @MikaMikaMika89 3 месяца назад +1

    I use those plugs for my diy work, absolutely solid completely trust them.

  • @JAUNCLAUD21
    @JAUNCLAUD21 3 месяца назад

    ive always just used 6mm plugs, they work amazing

  • @olly7673
    @olly7673 3 месяца назад

    Try putting a quick release bar clamp over the CU knockouts when drilling next to them, and would your assessor want you to trim back the sheathing a bit more near the top of the CU? Nice , neat CU change though and finished off nicely with the trunking, good job Nick....... but did you need to number the 10mm and 6mm cables?😆

  • @ianholt375
    @ianholt375 3 месяца назад

    Those plugs are ace. Fisher Duopower, Toolstation keep them in. They do them in various sizes and lengths as well.

  • @peterbradley4916
    @peterbradley4916 3 месяца назад +16

    I poke the trunking straight into the board (bout 10mm thru). saves messing about with grommet strips. more room for cables as well.

    • @TheChipmunk2008
      @TheChipmunk2008 3 месяца назад

      10mm is a bit excessive, but agreed

    • @PearsallEu
      @PearsallEu 3 месяца назад +1

      ​@@TheChipmunk2008 gives space for expansion

    • @MegaMetinMetin
      @MegaMetinMetin 3 месяца назад

      @@PearsallEu😂😂😂

    • @richardbushnell1065
      @richardbushnell1065 3 месяца назад +1

      i pack my boards off the wall and take all cables through the back

    • @TheChipmunk2008
      @TheChipmunk2008 3 месяца назад

      @@richardbushnell1065 another good strategy, saves faffing

  • @shaun30-3-mg9zs
    @shaun30-3-mg9zs 3 месяца назад

    Good to see you work together again, nice work

  • @imark7777777
    @imark7777777 3 месяца назад

    You asked to be reminded. Actually it's a great idea you already did it! haha I'm watching them out of order.
    Don't know if they exist in the UK but they must over here in the United States we have in line plug things with a little push button remote control for Christmas lights and the like. I like using them to turn my fan on and off. The downside is the little remote usually require batteries so the kinetic is probably a better way to go. We don't have that kind of stuff yet relatively on store shelves maybe special order from the wholesaler maybe.

  • @mohamedsiadabdille7631
    @mohamedsiadabdille7631 3 месяца назад

    Nick thanks for video and your time for us really enjoying and is useful video

  • @JohnDundee-el2ro
    @JohnDundee-el2ro Месяц назад

    Should have brought the cables in back entry into the big square knockouts grommets for me back entry everytime better job by miles

  • @bencrabb303
    @bencrabb303 3 месяца назад

    Milwaukee M12 Cut off tool is perfect for this job!

  • @markbruce4828
    @markbruce4828 3 месяца назад

    Why not do another chase down to the db to make it as neat as the rest of the install? Or even drill a few large holes up to the ceiling g void at a slight angle. Then rear entry all the cables.
    It’s something that i always do and clients like it for the little extra effort.

  • @robpaine4012
    @robpaine4012 3 месяца назад +1

    Glad to hear that “Delicious” is back🤘🏼

  • @jonhigginson4096
    @jonhigginson4096 3 месяца назад

    I won’t use anything other than fischer red plugs, the ones you had there I save for pissy walls, really grippy.

  • @TheJoeyDeacon
    @TheJoeyDeacon 3 месяца назад +2

    Don’t leave a space for a future EV next to the high current draw circuits. The days of organising circuits high to low are gone. The heat created by the high current circuits de-rates the breaker. You’re better off going high low high low.

  • @couplandsj
    @couplandsj 3 месяца назад

    Love the videos Nick, it’s my daily homework. Quick one, which are your preferred manufacturer for sockets/cooker switches..?

  • @chriss9261
    @chriss9261 3 месяца назад

    Truly exceptional work on the CU install, glad to see all radial circuits, much better than I can do, however few points to note, the nicely grouped and secured cables in the trunking means several circuits are "bunched" or "grouped" together and this introduces a derating factor for the cables, why are people still using 1mm T&E anywhere in an installation?, I know this is a rewire but why are you putting the new CU in a non Part M compliant position? I know most if not all of Part M does not apply on a rewire of an existing building but we really should seriously consider putting new CU's at the recommended height in a readily accessible location, I always advocate for radials everywhere, but is 1 X 20A radial really sufficient for the whole upstairs or all of downstairs except the kitchen? 2 fan heaters on the same circuit during a cold spell in Winter and you are done! Really good to see a separate circuit for outside lights, is there a "Dusk to Dawn" (D2D) sensor for any outside lights not on a PIR?

    • @LordLorenzo834
      @LordLorenzo834 3 месяца назад +1

      1mm is fine ! reference method A in wall or conduit allows 11.5A , even if you used bunched grouping factors to further reduce current carrying capacity its still well in on a 6A Rcbo. Why would you use 1.5mm exactly ? You wouldn't.

  • @darrencoyle3290
    @darrencoyle3290 3 месяца назад

    Excellent educational video Nick.. great quality of work.

  • @Simon_Portillo
    @Simon_Portillo 3 месяца назад +2

    Wow. Another top notch job. Nice one.

  • @Shocker99
    @Shocker99 3 месяца назад +8

    Nick now working for Adam?
    The pupil becomes the master

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +1

      Just giving him a help in hand, mate

    • @TheChipmunk2008
      @TheChipmunk2008 3 месяца назад

      @@NBundyElectrical you have a loved one in common :) (JOSHING, no block plz)

    • @Shocker99
      @Shocker99 3 месяца назад

      ​@@NBundyElectrical I'm just joking around, mate
      It's all love ✌

  • @briancaveill3441
    @briancaveill3441 Месяц назад

    Hi mate, get a BG Electrical 822/HC-01 Smart Power Socket, with pattress for your hover etc?

  • @mylesie8078
    @mylesie8078 3 месяца назад

    Cool idea hover Switch thingy ....long hose to maybe

  • @EdwardBretherton
    @EdwardBretherton 3 месяца назад +4

    think i read this on a iet publication might be wrong though , It recommended arranging the board with high load then low load then high load then low load you get the picture to keep the c/u cool, rather than high loads all jammed up together, think it was an article on nuisance tripping , anyway nice looking job👍

    • @SparkcatcherFox
      @SparkcatcherFox 3 месяца назад

      I don't think it will let me link it here but it's in IET Wiring Matters issue 96. "Derating grouped circuit-breakers within a consumer unit due to mutual thermal influences".

  • @jackfairhurst3576
    @jackfairhurst3576 7 дней назад

    Should of got the larger fire clips for the trunking

  • @JGS123WRPTP
    @JGS123WRPTP 3 месяца назад +2

    Bloody cracking plugs those.

  • @KimMason-qq7hk
    @KimMason-qq7hk 3 месяца назад

    I've got a sleeve it I like it but really think it should be able to take 3 or 4 different sleeving earth, brown and blue would have been so obvious to me as a designer 🤷

  • @andrewpowell6457
    @andrewpowell6457 3 месяца назад

    Trunking & straight cables Nice Nick.

  • @BMW-Tourer
    @BMW-Tourer 3 месяца назад

    Nick why have you not switched to the new Doncaster cable with the earth already sleeved? they advertised the cost is the same as the current one so just wondering how lots of electricians have not switched yet?

  • @adriansmith8213
    @adriansmith8213 3 месяца назад

    That's such a tidy install, well done

  • @Steve90UK
    @Steve90UK 3 месяца назад

    Can you please do a video giving advice for people looking to change careers and train as electricians/ advice for apprentices? Cheers mate 👍

  • @robinhadley
    @robinhadley 3 месяца назад

    Quick question.
    Why 20a and not 16a for the sockets?
    Love the board 👌🏻

  • @ForTheBirbs
    @ForTheBirbs 3 месяца назад

    Good stuff Sir Nick! Never stop the Ads moooooommmmm references. Lol. One question- got a link for the nifty POV camera? Cheers

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад

    Back in the day metal capping was just cheaper. it's to stop the plasterers massacring the cable with trowels, and for some brands of cable to keep the plaster off.... (see manuf's directions, some are NOT rated for burial in plaster!)

  • @projectartichoke
    @projectartichoke 3 месяца назад

    That's one fine looking board!

  • @macaulyc
    @macaulyc 3 месяца назад

    What is the long attachment you use in your drill? And what do you find the benefit from using one so long compared to the standard bit holders for drills/impacts

  • @Shanky_TH9540
    @Shanky_TH9540 3 месяца назад

    the trunking to the board looked neat, but what's going on with the tails in the background going down the metre cabinet lol?? also is it over a 3metre tail run to the db? going through ceiling voids also??

  • @lukesadventures7192
    @lukesadventures7192 3 месяца назад

    another great video mate! quick question, i have a small 4 burner induction hob and a single electric oven. they are both on one 6mm2 cable. is this okay? thanks

  • @MarcusNailor
    @MarcusNailor 3 месяца назад

    Great idea at 4:50 you should call it Deadfoot 😆

  • @JurassicJungle
    @JurassicJungle 3 месяца назад

    My Festool vac has Bluetooth and you can add a bluetooth button to the hose.

  • @NickyLong89
    @NickyLong89 3 месяца назад

    Life creeps up on you sometimes. Here I am, Saturday night, enjoying that consumer unit work 👌🏻 very nice! Took a while I know but well worth it. A real shame when you put the covers on and nobody can admire haha to the untrained, just looks like you’ve screwed a box and a bit of trunking to the wall…. Then people question prices haha

  • @garylatto4191
    @garylatto4191 3 месяца назад

    Nice job on the board nick 👏

  • @richrowley8355
    @richrowley8355 3 месяца назад

    Such a neat job Nick. You good job 😀

  • @jackshorten9148
    @jackshorten9148 3 месяца назад +1

    NICK! Don't hide that drill bit pouch from us. 2:40 What is it and where is it from?

    • @MarcusNailor
      @MarcusNailor 3 месяца назад +1

      Velocity Drill Pod 😁 it's a decent case, only ~£30 too

  • @TheDranny
    @TheDranny 3 месяца назад +1

    Welcome to the Fischer duopower club. Come on in, the water is lovely.... 😂

    • @TheChipmunk2008
      @TheChipmunk2008 3 месяца назад +1

      worth the extra ? will have to give em a go

  • @HeathenGeek
    @HeathenGeek 3 месяца назад

    ooh, fancy fkr 🤣
    Really nice board install btw. Summat to try sometime could be putting the earth sleeve on, making up labels using that Brother heatshrink, and putting them on the cables? That way each cable would be labelled and the earth sleeve would be held on by the heatshrink.
    Hmm, I think I'm going to try that 🙂

  • @AndyK.1
    @AndyK.1 3 месяца назад

    If I’m using MK accessories I’m careful to get brown and blue run down the wall on the correct side.

  • @peterigrenyi9176
    @peterigrenyi9176 3 месяца назад

    Do u test it before u start stripping it ready for the board or do you disconnect it all as you test it?

  • @matthews2605
    @matthews2605 3 месяца назад

    Forgive me if I'm wrong, but I'm pretty sure you're not allowed to cable tie cables to pipes?

  • @markthompson265
    @markthompson265 3 месяца назад +1

    Why don’t you use a Tapo plug which you can switch on off with phone

  • @ClarkyAv
    @ClarkyAv 3 месяца назад

    Does it down rate the cables running multiple of them in parallel like that into the consumer unit?

  • @paulwilkinson6608
    @paulwilkinson6608 3 месяца назад

    Why did you use a multi tool to cut trunking.
    You need a milwaukee grinder with a 1mm slit disc

  • @darylsavage119
    @darylsavage119 3 месяца назад

    Why do you use the older fusebox rcbos instead of the minis that are also safer due to being double pole isolation on switching? Is it purely to save £1.50 an rcbo?

  • @projectrebuild908
    @projectrebuild908 3 месяца назад

    Smart looking install

  • @lukemacleod6325
    @lukemacleod6325 3 месяца назад

    What’s the long attachment bit you always use ?

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад

    the blank to allow another of the same rating is quite clever

  • @1mannik
    @1mannik 3 месяца назад

    Nice work Nick

  • @imark7777777
    @imark7777777 3 месяца назад

    Is that all we have to do to get those folks to stop complaining about the yo mama jokes.
    I think they're reasonably tasteful and not too overdone most days. But I've also been watching the greatest technician who makes it into wordplay.

  • @grahameburnip5880
    @grahameburnip5880 3 месяца назад

    Been using those plugs for few years now.

  • @nearlyjuly7990
    @nearlyjuly7990 3 месяца назад

    Excellent install.
    Tell me guys, who else is posting regular electrical content right now? Sparky RUclips seems to have died a death lately

  • @kvyng1
    @kvyng1 3 месяца назад

    Often thought that Quinetic should really have something like that in their range. Seems like a no brainer to incorporate wireless switch into socket outlet

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад

    On stage, as a drag act next to adam's mum :D With lengths of flexicon

  • @TheChipmunk2008
    @TheChipmunk2008 3 месяца назад +1

    Coil on the gas bond triggers me, introduces inductance... probably doesn't matter but to me: NO

  • @tonywatson1412
    @tonywatson1412 3 месяца назад

    Is all that extra cable below rcbo,s neccesssry....sure its hidden ...but it must be crammed in ?

    • @edc1569
      @edc1569 3 месяца назад

      The way we do electrics in the UK it is as the IET make you throw away consumer units every decade.

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +1

      Not really crammed whatsoever, as you can see from the video, makes the next person’s job a lot easier

  • @AntsInTheMeadow
    @AntsInTheMeadow 3 месяца назад +1

    Was just watching Adams video about this 😂😂😂 prefer your content nick 👌 how's your meds going?

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +2

      So far so good mate

    • @AntsInTheMeadow
      @AntsInTheMeadow 3 месяца назад +1

      @@NBundyElectrical as someone who takes meds for ADHD you'll be wishing you had started them sooner 👍

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +2

      @@AntsInTheMeadow just been bumped up to 70 mg today, so we’ll see if I cure world hunger in the next week?

    • @AntsInTheMeadow
      @AntsInTheMeadow 3 месяца назад +1

      @@NBundyElectrical yea I'm on 56mg and it definitely will cure your world hunger 😂 but everyone is different ay😉 wish you all the best mate 👍

  • @Fatalfog
    @Fatalfog 3 месяца назад

    they make bluetooth sockets with remotes btw, creative thinking with the kinetic switch tho lol.
    Ikea makes a nice looking one for you:
    www.ikea.com/gb/en/p/tretakt-plug-with-remote-control-smart-30569726/?gclsrc=aw.ds&gad_source=1&gclid=CjwKCAjwnqK1BhBvEiwAi7o0X3d3fgQHBXV161wzKkhP1VtS92sEWkwn7JDAhuB7rdjWxKBebE0I-xoC2Y8QAvD_BwE&gclsrc=aw.ds

  • @paulsidebyrne
    @paulsidebyrne 3 месяца назад

    Cables at the bottom look crap mate, messy board in my opinion

  • @paraicheneghan8934
    @paraicheneghan8934 3 месяца назад

    Get a remote control socket

  • @g.williamswilliams8442
    @g.williamswilliams8442 3 месяца назад

    A wee bit excessive but...... Yoo Good Job 😂

  • @peterandrewwilson976
    @peterandrewwilson976 3 месяца назад

    Nice neat CU. ❤

  • @timballam3675
    @timballam3675 3 месяца назад

    Festool!

  • @enochabban8086
    @enochabban8086 3 месяца назад

    Nicky I was once watching your RUclips video, but I sent you messages u didn't reply

  • @g.williamswilliams8442
    @g.williamswilliams8442 3 месяца назад

    P.s... How the fuck did you manage Not to knock those knockouts out when cutting your slot.... What's the secret ?
    Yoo Good job 😂

  • @craiggoddard488
    @craiggoddard488 3 месяца назад

    Boiler on a 20 amp?

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +1

      Yep 👍

    • @sregoreel
      @sregoreel 3 месяца назад +2

      ​@@NBundyElectricalwhat's with these people 😂, feed it in a 10mm armoured via a 40amp rcbo if you like, as long as the spurs got a 3amp fuse. Little warriors getting their panties in a twist over something so inconsequential

  • @AndyK.1
    @AndyK.1 3 месяца назад

    You can tell Nicks paid per hour on this one. 😂

  • @DS-tp6vx
    @DS-tp6vx 3 месяца назад

    Why on earth would you put a boiler circuit on a 20a circuit? Just put it on a 6a with 1.5 t and e surely?

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +2

      You have future expansion of this circuit for an immersion or additional wiring, same route for the cable ,same price for the RCBO
      Personally speaking, if you wire a boiler circuit in a one mil cable You’re not thinking about future alterations

    • @kloddi25
      @kloddi25 3 месяца назад +1

      @@NBundyElectrical should have wired 6mm just incase they install heat pump in the future.

    • @DS-tp6vx
      @DS-tp6vx 3 месяца назад +1

      @@NBundyElectrical well I wire heating circuits in 1.5 and you are correct, I don't think about expansion of the circuit. Why? Because that's not my job. My job is to provide a safe and compliant install and to keep costs as low as possible by not using unnecessary materials.
      I know it's no big deal to use 2.5 instead of 1.5 for a single circuit but imagine if that's an entire apartment block (the majority of what I do), you would then be wasting thousands of pounds worth of copper. And tbh, immersion heater circuits in my opinion should be on their own circuit anyway as heating elements burn out and trip the RCD fairly regularly when used a lot.
      And, where does this all stop? Using your logic, you should wire the lighting circuit in 2.5 just in case you ever want to add sockets to it. Or maybe run a 10mm to every room for future submains for some power hungry tech that may or may not ever be installed. You see how silly that argument can become?

    • @NBundyElectrical
      @NBundyElectrical  3 месяца назад +3

      @@DS-tp6vx the argument isn’t silly in the view of your comment on my video in a domestic rewire the cost difference between a 2.5 mil cable and a 1 mil cable is pence, what would be silly is to compare that to hundreds of apartment blocks that you rewire,
      All I’m trying to say is what Harm does it make trying to future proof stuff and make it a bit easier yourself coming back to the job or another sparking in the future

    • @DS-tp6vx
      @DS-tp6vx 3 месяца назад

      @@NBundyElectrical I get that, future proofing is a sound argument to make. But you said that anyone installing a boiler circuit using 1.5 is not thinking about future alterations. I'm saying why stop there? I could easily throw that back at you and say you should wire all your socket radials in 4mm to allow for future expansion. Or that your tails should be 35mm to allow for a bigger supply from the network in the future. To me, you wire for what's there because what could be there in the future is an endless list of possibilities. You have selected one circuit for an upgraded cable size in comparison with the design current, why not apply that to every circuit?