Sir sami electrical stacker wares concession ke bhare me 1 video banate
ruclips.net/video/0zaeTQRC5yo/видео.htmlsi=HRh5gXfYF_RbOlJZ
Toyota Bt stacker battery indication showing 10 percentage only changed battery also with full charge pls tell me solution??
power cable check kariye, controller tak poora power nahi ja raha hai, yedi poora power ja rha hai to controller ka calibration karna padega
Electric forklift liver work nahi kar raha , repairing practical video
Sir bopt 10 problem solution btaye 🙏
Ok brother
Sir fuse kaise dicide kare
Clamp meter lagakar current check kariye gadi full load dekar, uske bad Jo current aata h wo fuse laga dijiye, ya phir controller jitne ampere ka h us se 50 amp. Kam ka fuse daliye
Sir fuse loom me ya main wiring me
400 amp ka controller hai loom wiring me kitne amp ka fuse aur main wiring me kitne amp ka fuse lagana hai aur kaise dicide kare
@@DeepakSingh-xv3pm loom wiring me uske load ke hisab se fuse lagega, iske liye clam meter method ka use kare
Curtis m karna sikhaya sir
aap curtis controller ke sath wiring bol rahe h kya?
@@forkliftandevji ha sir
Bahut bahut dyanwad sir is vidoe ko Hindi me banne ke liye ,apni meri bahut madad ki , please age bhi video banaye kare,
Very nice information sir g
Thanks sir please make more
Sar apps ki video se Hamen bahut Kuchh sikhane ka Milta Hai
Thank you
Danyavad sir j i
Sir sami electrical stacker wares concession ke bhare me 1 video banate
ruclips.net/video/0zaeTQRC5yo/видео.htmlsi=HRh5gXfYF_RbOlJZ
Toyota Bt stacker battery indication showing 10 percentage only changed battery also with full charge pls tell me solution??
power cable check kariye, controller tak poora power nahi ja raha hai, yedi poora power ja rha hai to controller ka calibration karna padega
Electric forklift liver work nahi kar raha , repairing practical video
Sir bopt 10 problem solution btaye 🙏
Ok brother
Sir fuse kaise dicide kare
Clamp meter lagakar current check kariye gadi full load dekar, uske bad Jo current aata h wo fuse laga dijiye, ya phir controller jitne ampere ka h us se 50 amp. Kam ka fuse daliye
Sir fuse loom me ya main wiring me
400 amp ka controller hai loom wiring me kitne amp ka fuse aur main wiring me kitne amp ka fuse lagana hai aur kaise dicide kare
@@DeepakSingh-xv3pm loom wiring me uske load ke hisab se fuse lagega, iske liye clam meter method ka use kare
Curtis m karna sikhaya sir
aap curtis controller ke sath wiring bol rahe h kya?
@@forkliftandevji ha sir