how to install auto transfer switching system between grid tied and off grid solar system

Поделиться
HTML-код
  • Опубликовано: 17 окт 2024
  • how to install auto transfer switching system between grid tied and off grid solar system
    here in this video you can watch about solar technology. There are 3 types of solar system in Pakistan
    1 off grid solar system
    2 on grid solar system
    3 hybrid solar system
    in thi video you can watch about on grid +off grid solar system
    in on grid solar system we can produce energy but in load shedding on grid solar system will turn off and solar power will lose during load shedding.
    in this video we are using auto transfer switch between off grid solar system and on grid solar system to get solar power in load shedding.
    so there is auto transfer switch of mora company .this swtich is for switching solar panels between on grid and off grid solar system.
    we are using 10 kw on grid growatt solar inverter.1.2 kw inverex veron 2 off grid solar inverter.
    in case of wapda on grid inverter will feed the grid and in case of load shedding on grid inverter will off and off grid inverter will attach to solar panels automatically and give solar energy.so if you want to learn how to install auto transfer switch so complete watch this video you will know much more.

Комментарии • 101

  • @anjum2626
    @anjum2626 10 дней назад

    Mere pas 15 kwa ka ongrid inverter he jis ke 2 stings hein aur 1 mere pas 6 kwa ka hybrid inverter he mein in ke dermian main ATS switch lagana chahta hu kon sa lage aur connection btain. ( 3 pole ya 2 pole)

  • @muhammadawaisalikharal6903
    @muhammadawaisalikharal6903 8 месяцев назад +1

    Very informative Vedio and Zaheer bhai bht cooperative ha Masha Allah ❤

    • @zaheerelectric
      @zaheerelectric  8 месяцев назад +1

      Thanks a lot.keep watching and don't forget to subscribe

    • @SajidKhan-vi3no
      @SajidKhan-vi3no 3 месяца назад

      ​@@zaheerelectricAj electric ki video or voice copy Kr k bhot teer mara ha

  • @ameeraslamkhan7807
    @ameeraslamkhan7807 Месяц назад +1

    Bahi short video bany tahnks

  • @sohailsheikh6559
    @sohailsheikh6559 8 месяцев назад +1

    Great and informative video

    • @zaheerelectric
      @zaheerelectric  8 месяцев назад

      Thanks a lot.keep watching and don't forget to subscribe

  • @Firoz.1411
    @Firoz.1411 Месяц назад

    Salamu Alaykum Brother, I’m from India and I need a help from you can you kindly help to set up my solar system

  • @zafarhanjra9166
    @zafarhanjra9166 8 месяцев назад +1

    kia sab soler panel same watts ke hain jo panel 1.2 ke sath hain aur jo Gro watt ke inverter ke sath lagy hain sab ke power same hay ?

    • @zaheerelectric
      @zaheerelectric  8 месяцев назад

      Abhi jo 1.2 k sath lgy hain same hain or jab yahi 12 panel ongrid py jaty hain to sary aik jesy nai hoty.kuch panel new hain kuch purany hain wattage ka frk hai.laikn thory bht wattage say koi frk nai parta q k panel k terminal voltage samy hoty hain almost.is leay lagay ja sakty hain.

  • @raowajahatvlog
    @raowajahatvlog 2 месяца назад

    @Zahid Electric agr 2 string aa rahi hon for OnGrid and 2 String for Hybrid/Off-grid. To ATS k connections kese karen gy for 4 wires ??

    • @zaheerelectric
      @zaheerelectric  2 месяца назад

      Phir 1 string ongrid ko permanent connect kr dain gy or dosri string k leay yeh wala ats 2 pole wala use hoga. Jis k commin point py string k connection or source A par ongrid or source B par offgrid k connection hongy. Or agr inverter hybrid ho jo grid feed b kar sakta ho to phir is switching ki zaroort nai.phir hybrid k sath b string k permanent connection hongy

  • @Khurram-cf7si
    @Khurram-cf7si 8 месяцев назад +1

    Great work

  • @razabhai9870
    @razabhai9870 7 месяцев назад

    Masha Allah bhai❤❤❤

  • @ChSaleem-ju6sc
    @ChSaleem-ju6sc 5 месяцев назад +1

    Nice videos sir

  • @syedshah7615
    @syedshah7615 6 месяцев назад

    main nai sunna hai k hybrid system ongrid feeding k liay successful nahi hai jaldi kharab ho jata hai kia yeh drust hai? mazeed ap kon sai sheron main kam kartay hain?please reply

    • @zaheerelectric
      @zaheerelectric  6 месяцев назад

      Market main bht sary inverter hain depend krta hai k ap hybrid konsa lety hain.inverex or solar max or is k ilawa or b bht sary top brands hain jin k inverter achy hain. Sasta inverter hoga to jaldi khrab hoga. Ham district rawalpindi main kam krty hain

  • @thesaadiqbal52
    @thesaadiqbal52 3 месяца назад

    People say ye Switch AC current ke liye he. DC me isko Aag lag skti he. Roshni dalen?

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      G bilkul yeh ac current k leay hai dc py melt ho sakta hai. Clint ko ham pehly bataty hain phir install krty hain. Filhal 5kw tak is py koi issue nai hua almost 1 sal say. Mazeed kitna chaly ga koi pta nai.technically not recommended for dc current

  • @AB-rz2ku
    @AB-rz2ku 7 месяцев назад

    Sir g ye ats toh AC hai jase ke uske upar generator bna hua ya DC ke liye b safe hai?

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад +1

      Specially dc k leay designed nai hai laikn abhi tak jin sites py lgaya hai koi issue nai aya.

  • @propertyewall
    @propertyewall 3 месяца назад

    ager on grid ki 2 strings hon or apny 2no strings se panels use kerny hon to kesy kerain???
    plz reply

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      2 alag alag switch lga k.laikn do say krny ki zaroort nai hoti q k choty inverter ki input single string hi hoti hai

  • @SolarSargodha
    @SolarSargodha 4 месяца назад

    yeah breaker to Ac current k lye nae ha?
    voltage 220v mentioned hain is per

    • @zaheerelectric
      @zaheerelectric  4 месяца назад

      Yes yeh ac current k leay hai. Laikn dc current py filahl thek chal rha hai.laikn technically wrong hai

  • @shakeeldilawar7148
    @shakeeldilawar7148 6 месяцев назад

    Sir off grid ku wapda ac supply on grid inverter ki out sy sy daini hai ya direct meter sy?

    • @zaheerelectric
      @zaheerelectric  6 месяцев назад +1

      Ongrid inverter ka aik hi terminal hota hai jo input b hota hai output b. Off grid ko wapda ki supply deni hai chahy inverter wali line say joint kr k dain ya direct dain

    • @shakeeldilawar7148
      @shakeeldilawar7148 6 месяцев назад

      @@zaheerelectric sir thank you for reply. Please Continue your work... Your chanel will be viral. Keep making videos.

  • @faheem783
    @faheem783 3 месяца назад

    Kia ap 2 pole ki circuit diagram share kr skty hyn?

  • @fahadayaz455
    @fahadayaz455 5 месяцев назад

    Agar raat mey light jaye gi tab bhi ats ki waja sey off grid par shift hujayega system ?? Tab to koi solar power nhi honi? Then kia hoga??

    • @zaheerelectric
      @zaheerelectric  5 месяцев назад

      Rat ko solar nai hoga or wapda b nai hogi to phir battery py jay ga.solar sirf din k time kar amad hai

    • @fahadayaz455
      @fahadayaz455 5 месяцев назад

      ​@@zaheerelectric Bahi raat ko wapda jab nhi hugi to ats to system ko off grid par shift kar deyga? Or off grid key sath batteries to nhi lagi hoein? Then Kia ho ga ye poch raha??

    • @zaheerelectric
      @zaheerelectric  4 месяца назад

      Batteries zaroori hain agar batteries nai hongi to din k time b shift nai hoga.

    • @zaheerelectric
      @zaheerelectric  4 месяца назад

      Is ats main manual function b hai din k time manual shift kr liya krain zat ko bijli waps any ka wait kr liya krain

  • @gursharansingh2911
    @gursharansingh2911 7 месяцев назад

    Hello 👋 janab agr 3 panal he karne ho alag to kea hame 9 panal k badd he +lena hoga please reply me

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад +1

      Whatsaap py message krian. 03175603686

  • @hamzaa3011
    @hamzaa3011 8 месяцев назад +1

    Agar ATS faulty hojy tu kya inverter harab hojyngy?

    • @zaheerelectric
      @zaheerelectric  8 месяцев назад +1

      Nai inverter ko kuch nai hoga.q k inverter sirf is leay khrab ho sakty hain jab aik hi time py dono inveter ko ikathi solar pannel ki supply mily to phir dono inverter jal jain gy.agr ats khrab b ho jata hai to woh kisi aik side py hi switch kary ga laikn dono inveter ko 1 time py supply nai day ga

    • @muhammadahmedjamil6975
      @muhammadahmedjamil6975 7 месяцев назад

      ATS ki price kia hai?

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад

      14500

  • @ZohaibAtiqKhan
    @ZohaibAtiqKhan 6 месяцев назад

    I have a 15KW Ongrid inverter with two MPPT strings. The first string consists of 18 Longi HiMo X6 panels, generating 10KW, while the second string comprises 14 older panels with specs of 360 Watts, 38 Volts, and 9.4 Amps per panel, totaling 5KW. The second string was reused from an old 5KW off-grid inverter setup.
    My question is whether I can safely use an AC ATS switch to alternate the second string between the on-grid and off-grid systems. Should I consider reducing the number of panels in the second string to lower the DC current passing through the ATS switch for safety? Also what should I do with first string having 10 KW PV input?
    18 لونگی ہائیمو ایکس 6 پینلز شامل ہیں، جو 10 کلو واٹ توانائی پیدا کرتے ہیں، جبکہ دوسری سٹرنگ میں 14 پرانے پینلز ہیں جن کی مواصفات 360 واٹ، 38 وولٹ، اور 9.4 ایمپیئر فی پینل ہیں، جو کے مجموعی طور پر 5 کلو واٹ بناتے ہیں۔ دوسری سٹرنگ پرانے 5 کلو واٹ آف گرڈ انویٹر کے نظام سے دوبارہ استعمال کی گئی ہے۔
    میرا سوال یہ ہے کہ کیا میں ایک (اے سی) اے ٹی ایس سوئچ استعمال کر کے دوسری سٹرنگ کو اون گرڈ اور آف گرڈ نظاموں کے درمیان تبدیل کر سکتا ہوں۔ کیا میں دوسری سٹرنگ میں پینلوں کی تعداد کو کم کرنے کی غور ضرور کرنی چاہیے تاکہ اے ٹی ایس سوئچ سے گزرتی دھاری کو کم کیا جا سکے؟ علاوہ ازیں، پہلی سٹرنگ جس میں 10 کلو واٹ کی پی وی داخل ہوتی ہے، اس کے بارے میں میں کیا کروں؟

  • @asifmehmood8426
    @asifmehmood8426 2 месяца назад +1

    How the batteries will be charged?

    • @zaheerelectric
      @zaheerelectric  2 месяца назад

      Pehly to wapda say charge hongi or phir loadsheding main din ko solar say. Sara kuch wesy hi kam krta hai jaisy normal hybrid

    • @asifmehmood8426
      @asifmehmood8426 2 месяца назад

      @@zaheerelectric load shedding ki surat main on grid se hybrid shifting main kitna lag ho ga? Power supply interrupt ho gi ya nahi?

    • @zaheerelectric
      @zaheerelectric  2 месяца назад

      Load wesy hi shift hoga jaisy normally inverter krta hai solar detect krny main delay hota hai bas. Q k inverter l sath batteries lagi hoti hain is leay load shifting main delay nai hota

    • @asifmehmood8426
      @asifmehmood8426 2 месяца назад

      @@zaheerelectric Thanx for the nice information.

  • @mianabdullah888
    @mianabdullah888 7 месяцев назад

    Mashallh great information God bless you

  • @PharmacologyMaster
    @PharmacologyMaster 2 месяца назад

    Aoa bro
    Kia load ham sirf off-grid sy laingay?

  • @aryanytseller
    @aryanytseller 2 месяца назад

    Hello bro,nice information,bro yeh batao k 3kw ongrid solar panel se 3kw k off grid hybrid inverter ko connection kese kre single phase hai

    • @zaheerelectric
      @zaheerelectric  2 месяца назад

      2 pole wala changeover (ats switch) use hoga .baki connection same hongy

    • @aryanytseller
      @aryanytseller Месяц назад

      @@zaheerelectric ok jnab,thanks🙏

    • @aryanytseller
      @aryanytseller Месяц назад

      @@zaheerelectric jnab connection krne wali video ka link dedo,3kw ongrid to off grid with ATS

    • @aryanytseller
      @aryanytseller Месяц назад

      Bta do jnab

    • @zaheerelectric
      @zaheerelectric  Месяц назад

      Ats k oper meri sirf yahi 1 video hai is k ilawa nai hai. 3 kw ongrid k sath kitny panel hain or off gird ko kitny shift krny hain.

  • @idreeskhalil635
    @idreeskhalil635 2 месяца назад

    Aoa sir es kay connection ka diagram pdf ma mil sakhta hy

  • @ABU.MOAVIA
    @ABU.MOAVIA 7 месяцев назад

    *اسلام علیکم ورحمتہ اللہ وبرکاتہ*
    *بھائی اگر 6 کےوی کے دو عدد انورٹر لیئےجائیں ۔ آن گریڈ اور آف گریڈ تو پھر 12 عدد سولر دونوں انورٹر پر برابر کام کریں گے*

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад +1

      Ni sir 12 panel ap ongrid py to lga sakty hain off grid ya hybrid py nai lga sakty q k uski voltage range 500 say zayada ni hoti.or 12 panel k almost 600 volt bnty hain.

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад +1

      9 panel shift kr sakty hain

    • @zaheerelectric
      @zaheerelectric  7 месяцев назад +1

      6 kw ka system hi lgana hai to phir 6 wala inverter b hybrid hona chaheay phir apko is pv switching ki zaroort hi nai

  • @ajmalfiraq6822
    @ajmalfiraq6822 6 месяцев назад

    AOA sir on grid or hybrid dono se riversing kr skty hain kia

  • @propertyewall
    @propertyewall 4 месяца назад

    apki location kahan hy ? kaya lahore mai installation ker sakty hn app?

  • @ishaqahmad5968
    @ishaqahmad5968 6 месяцев назад

    Is it ok to use this ac ats for dc?

    • @zaheerelectric
      @zaheerelectric  6 месяцев назад

      Theoretically to use nai krna chaheay laikn abhi tak jin sites py use kiya hai koi issue nai aya

  • @AliShahchenal
    @AliShahchenal 4 месяца назад

    Dear sound abhi bhi match nahi ker raha maine bhi koshish ki hai per 19 or 20 ka faraq hai zia farq nahi

    • @zaheerelectric
      @zaheerelectric  4 месяца назад

      Sound kis chez ka match nai ho rha. ???

  • @asiff2878
    @asiff2878 5 месяцев назад

    Good wark

  • @AHMAD-CHOUDARY
    @AHMAD-CHOUDARY 3 месяца назад

    @AJelectric
    Waly Bhai daikho ap Ki video ko kaisy remake Kiya ha

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      Hahaha. Nai g meri apni video hai ham aik team main kam krty hain apni apni video banaty hain is leay dekhny main similarity bht hai

  • @ShahidKhan-qj6gd
    @ShahidKhan-qj6gd 6 месяцев назад

    great

  • @waheed11111
    @waheed11111 Месяц назад

    i have a cofusion that why on grid doesnt work without main electricity

  • @MalikKhan37201
    @MalikKhan37201 6 месяцев назад

    Yeh ats switch kitny ka hy

  • @ImranHafeez-f9k
    @ImranHafeez-f9k 3 месяца назад +1

    السلام علیکم میرے گھر پہ 16 پلیٹس لگی ہیں اور میں اف گرڈ انورٹر سے سولر استعمال کر رہا ہوں اب میں نے نیٹ میٹرنگ کروانی ہے اور 10 کلو واٹ کا ان گرڈ انورٹر خرید لیا ہے کیا اپ میرے گھر پر یہ سروس فراہم کر سکتے ہیں جو بھی فٹنگ اپ نے ویڈیو میں بتائی ہے?

  • @adeelhassan8641
    @adeelhassan8641 5 месяцев назад

    sparking to ni hoti

  • @asad-wj6qx
    @asad-wj6qx 4 месяца назад

    Ye hybrid se acha setup hai.

    • @zaheerelectric
      @zaheerelectric  4 месяца назад

      Nai hybrid hi acha setup hai.laikn yeh un k leay acha hai jin k pass already ongrid lga hua hai phir woh sath 1 chota system lga k backup lety hain. New installation k leay hybrid hi recommended hai.

    • @irfanashraf6547
      @irfanashraf6547 3 месяца назад

      @@zaheerelectric is solution main load kaise manage kerte hain . kia load side bhi ongrid aur off grid ke between switch kare ga through some relay or load transfer ??

  • @umarhayat7030
    @umarhayat7030 8 месяцев назад

    Ats ki price

    • @zaheerelectric
      @zaheerelectric  8 месяцев назад

      11000 ka mily ga apko shop say .sirf ats.

  • @UmarAKhan-gt8fg
    @UmarAKhan-gt8fg 6 месяцев назад +1

    Its risky as switch is not designed for dc current

    • @zaheerelectric
      @zaheerelectric  6 месяцев назад

      Yes . Yeh switch ac current k leay designed hai laikn abhi tak is ki performance dc current py b bht achi mil rhi hai

  • @SajidKhan-vi3no
    @SajidKhan-vi3no 3 месяца назад

    Aj electric ki video or voice copy ki ha 😂 😂 😂

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      We are team. Same video hoti hai same site py.

  • @alimehboob9387
    @alimehboob9387 4 месяца назад

    Aj electrical chanel ka copy video

  • @taimoorshabbir791
    @taimoorshabbir791 6 месяцев назад +1

    Its a copy Video

    • @creativestudio3294
      @creativestudio3294 4 месяца назад

      اے جے الیکٹرک کی ویڈیو کاپی کی ہوئی ہے ہو سکتا ہے فراڈ کرتا ہو

  • @umerorakzai1
    @umerorakzai1 3 месяца назад

    Aj electric copy video voice

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      Nai janab .awaz b apni hai or video b. Ham aik hi team main hain or same site py video same hoti hai hamari.

  • @TaimurJan-y5y
    @TaimurJan-y5y Месяц назад

    Copy video

  • @adnanmasood9891
    @adnanmasood9891 3 месяца назад

    He has copied this video verbatim from AJ electric. What a fraud this guy is

    • @zaheerelectric
      @zaheerelectric  3 месяца назад

      We are team
      Same site py video b same hi hoti hai.

    • @ShoaibHayat-kb1tw
      @ShoaibHayat-kb1tw Месяц назад

      Sir yeah batyn ke jab wApda aye ge to 12 ky sath solar panels 4 panels bi on grid par shift ho jyn ge

  • @asiff2878
    @asiff2878 5 месяцев назад

    Sir ap ka wahtseb number chy