    On this episode I'm going to show you How Run Short Existing Electrical Wire Through Top or Bottom Plate Studs without boring a hole through the studs on weird situations | DIY
    DO YOU HAVE QUESTIONS ON YOUR HOME REPAIR OR DIY PROJECT? GET TIPS, ADVICE AND ANSWERS! BECOME A FIX THIS HOUSE MEMBER!
    Become a FIX THIS HOUSE Member by clicking on this link: / fixthishouse
    Please Subscribe To Our Channel! / fixthishouse
    FOR BUSINESS INQUIRES SEND TO:
    FIX THIS HOUSE
    P.O. BOX 2511
    BREMERTON, WA 98310
    UNITED STATES
    FOR BUSINESS INQUIRES EMAIL ME AT:
    fixthishouse1@yahoo.com
    DISCLAIMER:
    This video is meant for informational, educational, and entertainment purposes only! To better your knowledge on the concepts of electricity, electrical circuitry, entertainment component circuitry and all other wiring methods. Electrical codes in my area may be different from yours so always make sure you follow and stay current with your local code. With different codes around the world constantly changing standards, regulations and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Fix This House cannot claim liability with all applicable laws, rules, codes and regulation for a project. DO NOT ATTEMPT ANY WIRING OF ANY KIND if you lack the knowledge and understanding required. Otherwise, personal injury and/or death as well as property damage or loss could occur. Your safety is your own responsibility, including proper use of equipment and safety gear, and determining whether you have adequate skill and experience. If you are a younger person or are inexperienced with electrical devices, ask for help from a parent, teacher or a licensed professional.
    WARNING- Electricity is dangerous and can cause personal injury or DEATH as well as other property loss or damage if not used or constructed properly. If you have any doubts whatsoever about performing do-it-yourself electrical work, PLEASE do the smart thing and hire a qualified and licensed electrician to perform the work for you.NEVER WORK WITH LIVE VOLTAGE. Always disconnect the power source before working with electrical circuits.When performing electrical work, ALWAYS READ AND FOLLOW THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES. Always follow your local electrical code and requirements which are specific to local areas.By utilizing this video and the information given, YOU are expressly holding "FIX THIS HOUSE" HARMLESS FOR ANY PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH, OR ANY OTHER LOSS OR DAMAGE THAT MAY RESULT FROM YOUR ACTIONS. Viewers must be aware by doing projects on their homes they are doing it at their own risk and Fix This House cannot be held liable if they cause any damage to their homes. Fix This House and all parties associated with it ARE NOT responsible for the use and results of this information by any party, especially those lacking sufficient skill or knowledge to perform these steps safely and ANY HAZARD CREATED IS THE SOLE RESPONSIBILITY OF THE USER.
    DISCLAIMER: This video contains affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
    #Drywall #electrical #diy

Комментарии • 77

  • @lukeblackford1677
    @lukeblackford1677 Год назад +6

    Thanks! Great info. I didn’t know about nail plates. Great job too. FYI, rule of thumb, paper tape for premix (air dry) joint compound, mesh tape for quickset, as you did.

  • @envisionelectronics
    @envisionelectronics Год назад +8

    I had this exact situation when I did my kitchen. Same fix too. Glad I made the right choice because it was a head scratcher for sure.

    • @FixThisHouse
      @FixThisHouse  Год назад

      Nice! Thank you for sharing! 🙏🏽😊

  • @rudymustang06
    @rudymustang06 11 месяцев назад +1

    I have this exact situation and now I know how to fix it. Thank you.

  • @adisharr
    @adisharr День назад

    I'd also notch a bit for the nail plates so the drywall can sit flush.

  • @danielmierop662
    @danielmierop662 Год назад +3

    Thank You, I have just exactly that problem. Learned something!

    • @FixThisHouse
      @FixThisHouse  Год назад

      I’m glad I could be of help Daniel! Thank you for watching! 🙏🏽😊

  • @seaofrage
    @seaofrage 6 месяцев назад

    Very helpful video! Ran into this when i removed the soffet over my bathtub.

  • @ryanfowler2055
    @ryanfowler2055 Год назад +26

    For future reference, make sure the wire sheathing is not making direct contact with the edge of the nail plate, as they have sharp edged, other than that awesome work.

    • @FixThisHouse
      @FixThisHouse  Год назад +4

      Thank you Ryan for the advice! 🙏🏽😊👍🏽

    • @majahanson311
      @majahanson311 Год назад +1

      Sounds like a good idea, but how would you do that in this situation?

    • @MoneyManHolmes
      @MoneyManHolmes Год назад

      Maybe notch a little deeper.

    • @alexb9039
      @alexb9039 Год назад +2

      Electrical tape over edges that touch the wire would cut down on the sharpness

    • @bobblum5973
      @bobblum5973 Год назад +4

      I'd suggest using a file on those sharp edges before installing the plates. Prepare them beforehand, so they're ready for use when needed.

  • @jeffbyfield1821
    @jeffbyfield1821 7 месяцев назад

    I use a spade bit to notch out a small channel and clean up the sides with a multi tool.

  • @EMTDawg
    @EMTDawg Год назад +5

    Am I the only one who thought, just pull the unfinished sheet rock no cutting necessary... plus adds a better visual of what fixes are possible.

  • @jim5812
    @jim5812 2 месяца назад

    This video solved the issue i was having, thanks so much!

  • @freedomprivilege6344
    @freedomprivilege6344 4 месяца назад

    Very thoroughly explained. Good job!

  • @nsanerydah
    @nsanerydah Год назад

    Nice job. Simple and straightforward.

  • @jaydee3046
    @jaydee3046 7 месяцев назад

    I save the weights in the bottom of vertical blinds before throwing them away. I use them when I have no nail plates available.

  • @christopherdekonstrukt444
    @christopherdekonstrukt444 Год назад +1

    Awesome. I have to upgrade my electric service and know I'm going to run into surprises. Need 2 20A dedicated circuits in garage and in back room I use for mitre saw and my box is full. I know I have to get a permit and install a sub panel next to the main. If I don't have to upgrade my main panel I may be able to do it myself through self learning and poring over the NEC codes and ones from my area. Worst case I'll know what to buy and have everything ready for the electrician if I need to hire one.

    • @FixThisHouse
      @FixThisHouse  Год назад

      That’s awesome Christopher! Yes having all materials ready will save cost and time for sure! I wish you well! If you don’t mind sharing the cost to install the sub panel would be great!

    • @christopherdekonstrukt444
      @christopherdekonstrukt444 Год назад

      @@FixThisHouse will do. Maybe not next year but hopefully in 2024. The state of the economy has me concerned and I've idled most of my woodworking projects.

    • @rupe53
      @rupe53 Год назад

      if you watch a few videos on electrical load calculation, you may find the panel is full of breakers, but not fully loaded, power wise. In that case you can get some split breakers and gain a few slots to add more circuits. If you don't have central AC, hot tub, well pump, or electric heat, you'd be amazed and what you can do with an existing 100 amp panel.

    • @toddjasper1
      @toddjasper1 Год назад

      Honestly, adding a sub panel is not a DIY project. There are several ways to get hurt or killed doing that. I would get several quotes and then ask the electrician you like the most if there’s any part of it that you can do yourself to keep costs down. They will usually work with you

    • @deenell9039
      @deenell9039 Год назад

      Here's something that may help you out. If there's parts of your house that don't need electricity, just switch the wires on that circuit breaker if you can't make room for a new breaker in your sub panel. If the power you need in the garage isn't a permanent need, just switch the wires out of a breaker.

  • @eugenkaranxha5053
    @eugenkaranxha5053 Год назад

    I use the fiber tape try that next time it’s the best tape I found so far it blends perfect with the drywall when you send it down and you won’t see the tape at all or the shape of it after it’s finished and it bond’s perfectly vs the paper tape that I see a lot on properties that it comes loose after a period of time

  • @markfisher1716
    @markfisher1716 Год назад +3

    Well explained video.

    • @FixThisHouse
      @FixThisHouse  Год назад

      Thank you so much Mark! 🙏🏽😊

  • @kolitiokada9825
    @kolitiokada9825 Год назад +1

    Hi! What's your first name? Thanks for the great video!
    Had this situation recently when my handyman removed the soffits in my kitchen - he notched the wood a little, like you did, however he did not use nail plates. hmmm...
    And how about reading that code - it would drive me to drink...and I don't drink ;)
    The illustrations/diagrams are more my style.

  • @Mrdealornodeal618
    @Mrdealornodeal618 Год назад

    Good video. I had this exact similar scenario

  • @brettmullins751
    @brettmullins751 Год назад +2

    Awesome video..great teacher

    • @FixThisHouse
      @FixThisHouse  Год назад

      Thank you so much Brett! 🙏🏽😊

    • @brettmullins751
      @brettmullins751 Год назад

      @@FixThisHouse before oscillating tools i don't no how person would do the demonstration on running wires for ceiling fans

  • @Forged_Garage
    @Forged_Garage Год назад +3

    awesome!!! another informative video!!!

  • @deborahhaynes8361
    @deborahhaynes8361 Год назад +2

    That was so helpful ty

    • @FixThisHouse
      @FixThisHouse  Год назад

      Thank you so much Deborah for the feedback! 🙏🏽😊

  • @DrWhoRocks333
    @DrWhoRocks333 2 месяца назад

    That top nail plate is going to slowly slice thru that romex. Definitely a code violation.

  • @joeweatlu5169
    @joeweatlu5169 Год назад +1

    Thanks great advice!

  • @Neeboopsh
    @Neeboopsh Год назад +1

    i like this channel.

  • @Allen-L-Canada
    @Allen-L-Canada Год назад +3

    The work look so neat and easy, but I am thinking just get those tools (the special woodcutter etc) and materials (metal plates) would take days of work....:)

    • @FixThisHouse
      @FixThisHouse  Год назад +1

      Thank you brother! Yes the oscillating tool is a must for multiple purpose work 👍🏽😊

    • @ronald5728
      @ronald5728 Год назад

      A sharp chisel and a hammer would do the same job.

  • @zimpler8340
    @zimpler8340 Год назад +1

    Simple: notch the studs, put wires in notch, and cover with metal guard. Simple.

    • @FixThisHouse
      @FixThisHouse  Год назад

      It seems simple but make sure you are within code and structural limit areas 👍🏽😊

  • @MohdNaous
    @MohdNaous Год назад +1

    nice videos, may I ask what camera you are using while filming. thanks

    • @FixThisHouse
      @FixThisHouse  Год назад

      Thank you! For most of my jobs were it gets dirty it’s the a6300 - amzn.to/3Upv6AZ
      For my cleaner environments it’s he a7iii - amzn.to/3G5lw1R

  • @al52269
    @al52269 Год назад +1

    Great video
    Thanks for sharing
    New subscriber here

    • @FixThisHouse
      @FixThisHouse  Год назад

      Thank you so much Alcides! Means a lot for your support! 🙏🏽😊

  • @mikemike7397
    @mikemike7397 Год назад

    Bad ass job dude

  • @tablatronix
    @tablatronix Год назад

    I have this issue but with a laminated beam.. :(

  • @tinaweller9518
    @tinaweller9518 4 месяца назад +1

  • @stanleyvo5198
    @stanleyvo5198 8 месяцев назад

    Nice ! ❤😊

  • @wm437
    @wm437 Год назад

    Wow, I'm amazed at how many wood, electrical and plaster experts there are in the comments. I feel inadequate with only 40 years of experience. Guess I'll keep my comments to myself.😳

  • @user-mj8ml2vs5d
    @user-mj8ml2vs5d 8 месяцев назад

    What if one of the sides is metal instead of wood

  • @billgates3699
    @billgates3699 Год назад

    Yes, Wong, I’m very interested “on” the “residenshinol” code book 🙄

  • @frankpizarro7924
    @frankpizarro7924 Год назад

    it's easy

  • @evictioncarpentry2628
    @evictioncarpentry2628 Год назад +2

    I don't think that passes code in most places. Can't have wire touching a metal plate.
    The proper way to do this is to disconnect the wire in the attic and drill the hole in the top plates and run the wire properly

  • @firebird77clonefirebird89
    @firebird77clonefirebird89 Год назад

    Was the original routing up to code?
    If so, I'd have mudded them in and called it good.

  • @kapdolkim1914
    @kapdolkim1914 Год назад +1

    Those nail plates wouldn't pass inspection. Electrical wires vibrate and over time will wear off when touching metal.

  • @chriswilkinson2548
    @chriswilkinson2548 Год назад

    Common Sence.

    • @FixThisHouse
      @FixThisHouse  Год назад +1

      Just helping those who don’t know sir 🙏🏽

  • @marksteele45
    @marksteele45 Год назад

    Never use paper tape with hot mud. Never use mesh tape with pre mix mud.

  • @drewbush6535
    @drewbush6535 Год назад +1

    👋👍

  • @brianwilless1589
    @brianwilless1589 Год назад +1

    Chain saw would cut it out much faster than the oscillator.

    • @FixThisHouse
      @FixThisHouse  Год назад

      🤔

    • @stevelopez372
      @stevelopez372 Год назад

      Funny, in production Home Building a few decades ago I saw many chainsaws being used by the plumbers. It came to an abrupt end when the Home Builder received huge framing repair bills due to the use of chainsaws. Lol.

  • @freak3dot
    @freak3dot Год назад

    Don't do this. Run a new wire properly.
    Running it through a hole in the top plate is cleaner and safer.

  • @akan626
    @akan626 Год назад

    That's not how a professional does it.
    The notched part is fine but at the area next to it the NMC is still too close to the surface.
    You should have drilled a 1/2" hole through the center of the top plates.

    • @FixThisHouse
      @FixThisHouse  Год назад +3

      In the video I stated it’s this is for situations with fix wires