Post Tensioned Beam Installation Procedure at Site 🔥 | Components of PT Beam | Kavin Associates

Поделиться
HTML-код
  • Опубликовано: 7 сен 2024
  • #construction #home #beam #kavinassociates
    For PT works Contact:
    SF Engineering India (System) Pvt Ltd,Chennai
    9790921280
    They are doing PT Works all over India & Abroad at reasonable price.
    Ground Water Table Problem Solved ✅ | Types of Pedestal | When to go for PT Beam Designing ?
    - LINK - • Ground Water Table Pro...
    WATCH OUR LATEST VIDEOS:
    Transfer Girder with Floating Column 🔥 | Reinforcement Checking at Site | Hosur | Kavin Associates - LINK- • Transfer Girder with F...
    Nibav Vacuum Lift For Home 🔥 | Make your Home Luxury 😍 | Complete Tour and Customer feedback 😱 | KA - LINK - • Nibav Vacuum Lift For ...
    ₹2.15கால் லட்சம்னா சும்மாவா🔥| Live Testing at Site ✅ Using Original Schmidt Live Rebound Hammer - LINK - • ₹2.15கால் லட்சம்னா சும...
    WATCH OUR LATEST REPAIR SERIES VIDEOS :
    1.Column Strengthening Using Carbon Fiber Wrapping | Repair of Fully Corroded Column | Micro Concrete - LINK - • Column Strengthening U...
    2.வீட்டில் வரும் Wall Dampness-ஐ தடுக்கும் முறை 😱 | 100 % Solution | Repair Series | Kavin Associates - LINK - • வீட்டில் வரும் Wall Da...
    3.Terrace Floor-ல் வரும் Cracks, Water Leakage-ஐ எப்படித் தீர்ப்பது ? | PU Injection Method | 100% - LINK - • Terrace Floor-ல் வரும்...
    For Business Enquiry, Collaboration & Promotion - WhatsApp me - 9994087571
    Camera used for shoot - #iphone13promax
    App used for editing - #vneditor & #canva
    #youtube #youtubechannel
    If you like this video - Like, share and subscribe to my RUclips channel... LINK - / kavinassociates
    Share this knowledge to your friends and learn new things everyday and make your skill stronger...
    Follow me - / kavinassoci. .
    Like me - / kavin1011
    FOR QUERIES & DETAILS: Mail us at - kavinprivin5@gmail.com
    #housedesign #homeconstruction #homeideas #construction #building #hometips

Комментарии • 76

  • @janasanjay1227
    @janasanjay1227 Год назад +10

    Very Informative sir....The shape of tendon profile is given based on the BENDING MOMENT of the BEAM and Tendons are given based on calculating the losses due to the Post tensioning and also the PT increases the life span of structure while tensioning of beam rod.

  • @praveenraj519
    @praveenraj519 Год назад +1

    Very much interested to learn and execute your ideas in construction field sir. Myself is an civil engineer. I have been watching all your videos regularly. Recently i have executed the same idea for pedestal footing by watching your vedio sir. Thank you for sharing your knowledge with us. Keep going sir😊.. We all will support you😊

  • @navaneethakrishnan.rnavane2053
    @navaneethakrishnan.rnavane2053 3 месяца назад +1

    Ultimate தலைவா....Such a Great. Person Always

  • @prasannabs3975
    @prasannabs3975 6 месяцев назад +1

    Thank you sir very useful with clear instructions 👍

  • @nvdhamodaranrc8637
    @nvdhamodaranrc8637 Год назад +1

    Very great effert educative and informative for all junior level well done sir
    I had done it

  • @laxmanreddy7132
    @laxmanreddy7132 26 дней назад

    Hi @kavin associates
    Thanks for making knowledgable vidoes
    If possible plz provide more information like how much dia steel used for main pillars and total amount of stell used for single floor.

  • @arulprakash3341
    @arulprakash3341 Год назад +1

    Very use full site video sir
    PT structure beam
    Tq so much sir

  • @mohammedismail-lx2dq
    @mohammedismail-lx2dq Год назад +1

    super always ultimate good video and editing bro post more videos

  • @mokshithkrishna604
    @mokshithkrishna604 Год назад +1

    Speach sound very Low sir. But good message.

  • @ABDULRAHIM-de2ed
    @ABDULRAHIM-de2ed 2 месяца назад

    Min cube strength cube for stressing is 25 mpa as per British standard

  • @lragavendiran8187
    @lragavendiran8187 3 месяца назад +1

    Thank you. Voice too low at the end of video not audible

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw Год назад +1

    Very useful information sir. Sir if any code book for pt slab and beam

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 Год назад +1

    You doing great job sir ❤

  • @arulvasanthi
    @arulvasanthi Год назад +1

    Super brother, i am also a civil engineer.

  • @Profit_Momo_Pdf-File
    @Profit_Momo_Pdf-File 4 месяца назад +1

    next level stuff

  • @user-no5dw9ux4p
    @user-no5dw9ux4p 6 месяцев назад +1

    Nice explanation

  • @krantikumar268
    @krantikumar268 Год назад +1

    Hi Kavin Sir,
    Please provide level 1,2,3 course material in book form ??

  • @civil007manickavelt5
    @civil007manickavelt5 Год назад +1

    Useful content 👏

  • @prakashk7684
    @prakashk7684 Год назад +1

    Good information 👍

  • @prabhakaranganapathy34
    @prabhakaranganapathy34 4 месяца назад +1

    Sir pls give me a explanation, in some of the engineering videos saying near beam column joints beam rods should be cracked and to be inside the column ne is it right ? pls urgent

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  4 месяца назад

      Only 12,16 mm rods can be taken outside of column…because of larger dia like 20,25 mm rods it should be cracked into column then only you can get cover for column…so only if column rods are more congestion it’s necessary to increase the column width

    • @prabhakaranganapathy34
      @prabhakaranganapathy34 4 месяца назад

      @@KavinAssociatesOfficial thank you so much

  • @bavash100ul
    @bavash100ul Год назад

    I presume , tendon covering ku use pannathu GI illa flexible duct sleeve nu

  • @Askar_vlogs
    @Askar_vlogs Год назад

    GI pipe length enthana Feet varum...
    Live endla joint panni antha tendons minimum length evlo Veliya irkanum bro

  • @KumarKumar-fo5wt
    @KumarKumar-fo5wt Год назад +1

    Super sir

  • @jamasilamani
    @jamasilamani Год назад +1

    Brother 20mm rodla belt. 12 mm rod coloum podalama? Plz sollunga.

  • @advancedautocaddynamicbloc7359
    @advancedautocaddynamicbloc7359 Год назад +1

    New information

  • @laxmanreddy7132
    @laxmanreddy7132 13 дней назад

    What is the total slab area in sft ?

  • @velladurai.sdurai8928
    @velladurai.sdurai8928 9 месяцев назад

    PT slab video please

  • @9487645723
    @9487645723 Год назад +5

    Thank you for your efforts in making very detailed videos. Learning a lot from your videos. 😊

  • @vasuinba
    @vasuinba Год назад +1

    I studied in my bachelor's degree minimums grade of concrete should be grater than M40 So please confirm again as per IS Code

    • @DarshanDarshan-ns6yu
      @DarshanDarshan-ns6yu Год назад +1

      M40 grade for pre-tensioning
      but here for post-tensioned beam mini grade M30
      🙂

    • @gowthamarmstrong8981
      @gowthamarmstrong8981 Год назад +1

      M35 is the starting grade to be used in PT works bro

  • @muthuNeweast-wy6vw
    @muthuNeweast-wy6vw Год назад

    And sir Antha floating column purpose enna nu sollalaye .

  • @dubailomiteluguabbai3971
    @dubailomiteluguabbai3971 Год назад +1

    I want to construct 60 feet long beam between 2pillars. How many steel bars should I use, and what size of requisite
    between two pillars is 60 feet span possible...?
    reply bro please
    single floor 40 feet hight slab

    • @KavinAssociatesOfficial
      @KavinAssociatesOfficial  Год назад +1

      It’s possible only in PT not in conventional beam sir …

    • @dubailomiteluguabbai3971
      @dubailomiteluguabbai3971 Год назад

      @@KavinAssociatesOfficial thank u bro
      what is the cost for 60×40 plan design....?
      kindly can you send what's app number

  • @amthanamuthan1201
    @amthanamuthan1201 Год назад +1

    In market 12.2m lengths of rod only available how to active 42feet rod

    • @ManiGandan
      @ManiGandan Год назад +1

      Special length can be bought by ordering specific length from the steel company

    • @geodamin8351
      @geodamin8351 Год назад

      Bars will be lapped at appropriate locations for larger spans

  • @user-hd1ui8om3o
    @user-hd1ui8om3o Год назад

    Inside GI pipe it is rope not rod

  • @sivakrishnaduddu4592
    @sivakrishnaduddu4592 Год назад

    One more doubt sir, i had heard that incase of PT Slabs the concrete should attain 80% of its grade strength at the end of 7 days in order to do PT
    Is it true sir??

  • @ruby40483
    @ruby40483 Год назад +1

    Bro...apo PT beam oda load transfer conventional column laye pannuvangla...

  • @Prasob-pc8uu
    @Prasob-pc8uu Год назад +1

    Job vaccancy eruka sir

  • @ramyarishi6675
    @ramyarishi6675 11 месяцев назад

    Sir roof la beam podamal katti irunthal atharku ethana floor max eduka mudium sir

  • @kannadhasant1396
    @kannadhasant1396 Год назад +2

    How many floor will do same way

  • @sanjayputtesh2269
    @sanjayputtesh2269 6 месяцев назад

    1 rod length is 39 feet ,how 42feet single rod laid?

  • @rav8472
    @rav8472 Год назад

    Is that possible in clay soil.... Lower level sbc clay soil

    • @geodamin8351
      @geodamin8351 Год назад

      Soil type does not have any influence on the PT system.

  • @user-lg4lj5xg5m
    @user-lg4lj5xg5m 8 месяцев назад

    This work five year i am working Singapore job vacancy sir

  • @naazim4297
    @naazim4297 Год назад +1

    Mos, dos , ippo Dan puriyidu .

  • @ArunKumar-bz3dw
    @ArunKumar-bz3dw 6 месяцев назад

    Reference is 1343

  • @Myk_mash
    @Myk_mash 2 месяца назад

    Bro is walking on a site with crocs no safety shoe lol

    • @SharkFishSF
      @SharkFishSF 25 дней назад

      This is india, even kids here have access to construction sites because they have common sense where to go, where not to, and how to be safe in a construction site, we are also built different, not brittle bones or gender confused si**ies....