  • @kokomovans
    @kokomovans  Год назад +7

    New: Order an EcoFlow Kit from our site and you can schedule a FaceTime call with us to help with installation!

  • @gostay-2.2
    @gostay-2.2 Год назад +1

    What a great advancement in power for RV life. Hats off to EcoFlow!! All those blue box’s and exposed wires and lugs gone. This is the future.

  • @InvisageStudios
    @InvisageStudios 6 месяцев назад +4

    Amazing work! Just one tip - when you install the alternator charging cable, you need to move that 100A fuse as close to the van battery as possible. If you have a cable run through on the chassis on the section of cable BEFORE the fuse - you’re gonna burn your van to the ground.

  • @thomaskiser140
    @thomaskiser140 9 месяцев назад +6

    I installed Ecoflow Powerkit and added 3,150 watts of solar on my 34ft Avion Travel Trailer last June. I have 15kw of batteries and run my air conditioner on the system. Live full time in our rig. In the over 9 months I have not plugged into shore power or a generator. Totally off grid. Full time. Love my Ecoflow Power Kit!

    • @kokomovans
      @kokomovans  9 месяцев назад +1

      That sounds like an awesome rig!!

  • @bonnierodger7719
    @bonnierodger7719 8 месяцев назад

    Today is shore power, final hole making…lol. Without your video, we would have been stuck and too scared to install our ecoflow. Thank you for being a great teacher. Have a great weekend and stay safe.

  • @ChocolateManInThailand
    @ChocolateManInThailand Год назад +1

    Soft start for the win. Great video!

  • @bonnierodger7719
    @bonnierodger7719 8 месяцев назад

    Thank you for giving us the confidence to install our own EcoFlow…I love it.

    • @kokomovans
      @kokomovans  8 месяцев назад

      You're welcome Bonnie we're stoked to help!

  • @tifm9571
    @tifm9571 3 месяца назад

    Hey there, you didn’t show the solar portion of install and it’s the one I’m most confused about and can’t find any info on. I can’t figure out how to get the provided solar cable and mc4 connectors through a roof gland. Can you please advise? Thanks!

  • @bucketlistaddict
    @bucketlistaddict Год назад +2

    That system looks awesome.. I want that in my next build

    • @kokomovans
      @kokomovans  Год назад +1

      🤘 Ready to make it happen

  • @bonnierodger7719
    @bonnierodger7719 10 месяцев назад

    Thank you Sir! I am almost done installing my system. Your video helped me immensely.

    • @kokomovans
      @kokomovans  10 месяцев назад

      So glad I could help!!

  • @schassis_eddi
    @schassis_eddi 11 месяцев назад +1

    Is there anyway to implement this system to an existing RV AC/DC system without using the smart distribution panel?

    • @kokomovans
      @kokomovans  11 месяцев назад +1

      Yes you’re able to use your existing distribution panel in your rv. The wiring that goes to the distribution panel is standard AC/DC wiring. Please reach out on our website and we can help!

  • @fredzuccarelli
    @fredzuccarelli 5 месяцев назад +1

    Nice job!!! Im in naples, fl....and im looking for a builder!!!!

  • @rccosplay3249
    @rccosplay3249 Год назад +2

    I have the independence 15 Kwh kit . This video pretty much spells it out, Great system. For me in a off grid situation, it works great. It is rated for 3600watts it could put out

    • @kokomovans
      @kokomovans  Год назад

      Thanks for the input here! What do you use instead of the smart distribution panel? A regular breaker box?

    • @rccosplay3249
      @rccosplay3249 Год назад

      Yeah regular breaker box, I'm looking forward to setting up the Smart Box for monitoring and control.

    • @christopherbrandler508
      @christopherbrandler508 Год назад +1

      Thanks for comments.... How is this system working for you now that you've had it in a a while? Im hearing of some people having real troubles.

    • @rccosplay3249
      @rccosplay3249 Год назад

      @@christopherbrandler508 Working great as expected in the beginning then some trouble after 2 months of normal use. 1st issue was not charging to 100% it would stop at 85% ??? 2nd issue was a error code of AC bus overload and the unit would bug out when AC input stopped and inverter took over, it was much more than 30ms. Twice it shut down completely and re-started by itself??? safter contacting Ecoflow, they had me do a battery calibration test and download the latest firmware... Happy to report all is ok now, Ecoflow customer support seems pretty good 👍

    • @kokomovans
      @kokomovans  Год назад +1

      Glad the firmware update fixed your issues!@@rccosplay3249 For anyone else reading this, a firmware update is recommended for any new system you buy and is easy to do through the ecoflow smartphone app.

  • @johnkaprese36
    @johnkaprese36 7 месяцев назад

    Is it possible to „reverse charge“ your vehicle battery via the alternator charger of the PowerKit in case the vehicle battery is depleted?

  • @emil0rtiz128
    @emil0rtiz128 Месяц назад

    Couldn’t u just ground the negative wire to the van frame?

  • @davejordan5176
    @davejordan5176 4 месяца назад

    Great video! I've watched it 3-4 times now and am looking for advice: I'm installing a Nomadic X2 A/C unit to run off of my Ecoflow 5Kw system. Thinking I need a breaker for this, what do you recommend? Thanks!

  • @georgebeebe2385
    @georgebeebe2385 10 месяцев назад +1

    On my power distribution panel, there are 12 fuses, 12 positive lever connectors but only 8 negative lever connectors. If I have more than 8 lines - where do I connect the 9-12 negative wires?? Can they be double upped??

    • @georgebeebe2385
      @georgebeebe2385 10 месяцев назад

      This on the DC side.

    • @kokomovans
      @kokomovans  10 месяцев назад +1

      Yes they could be doubled up on the negative side. There’s also a negative output screw mount next to the negative pinch connections. You can put a ring terminal on extra negative wires and mount them on there.

    • @kokomovans
      @kokomovans  10 месяцев назад +1

      Make sure you don’t use the negative input screw mount

    • @georgebeebe2385
      @georgebeebe2385 10 месяцев назад

      Thanks!

    • @kokomovans
      @kokomovans  10 месяцев назад

      You’re welcome!

  • @arms501
    @arms501 4 месяца назад +1

    Dear... Can we Run 220 volt appliance?.. Tq..

    • @kokomovans
      @kokomovans  4 месяца назад

      No not directly on this system

  • @simon359
    @simon359 11 месяцев назад

    The only thing I don’t like that I see, is you using ANL audio fuses? I would try blue Sea fuses.

  • @davidroe1547
    @davidroe1547 Год назад

    Perfect. Thanks!

  • @hangyang1624
    @hangyang1624 4 месяца назад

    Hi good afternoon how much the cost if I buy the system same thing like this 10kw from you I am live MD thanks 🙏

    • @kokomovans
      @kokomovans  4 месяца назад

      Hi yes the 10kw system grand total tax included is $12,651.24 after taxes when you use coupon code 10off at checkout

  • @davidroe1547
    @davidroe1547 Год назад

    Great video - thanks. Quick question - do I need to ground the power hub to the vehicle chassis using the earth stud? If not, why not? Thanks!

    • @kokomovans
      @kokomovans  Год назад +1

      I’ve seen lots of debate going either way. I’ve heard it doesn’t matter for the 12v system or you only need to be grounded when plugged into shore power. Too much mixed info for me to give you a solid answer sorry. Go ahead if you need the peace of mind.

  • @goodoz9942
    @goodoz9942 Год назад

    Well done...install and video.

  • @mjeanes4244
    @mjeanes4244 Год назад

    Should I run a ground wire from the power hub to the van thank you

    • @kokomovans
      @kokomovans  Год назад +1

      Ecoflow says it’s not required but it won’t hurt to go for it 👍

  • @NickAbadilla
    @NickAbadilla 5 месяцев назад

    This was very helpful and informative. A couple of questions 1) Do both Ecoflow cables attach directly to the battery terminals, or do you ground the negative cable elsewhere? 2) Does it matter where you connect the inline fuse on the positive cable? I appreciate you help.

    • @kokomovans
      @kokomovans  5 месяцев назад +1

      Yes for alternator charging, you connect both the positive and negative wires to the battery.
      All that matters with the 100A fuse is that it’s easily accessible and is somewhere before the connection to the power hub.
      Glad I could help!

  • @agmgghgh3046
    @agmgghgh3046 7 месяцев назад

    Hola estimado, soy de Chile y compré este equipo más los paneles solares, generador inteligente hasta ahí todo bien carga perfecto las dos baterías de 2K, el único problema que tengo es que no me carga las baterías por medio del alternador del vehículo sino es con el modo carga pasiva ósea el motor en relanti es decir detenido. No sé por qué ocurre esto, me puede ayudar a configurarlo. Gracias 🙏

    • @kokomovans
      @kokomovans  7 месяцев назад

      ¿Se carga mientras conduces? No se carga automáticamente mientras el motor está en ralentí.
      Translated in Google translate

  • @BillFye
    @BillFye Год назад

    It looks like a great system. But for me, I would need more amperage available on the DC panel because it seems wasteful to run A/C off the AC line. I'd only want to run 120v outlets on the AC line and keep all other loads off of the inverter. Perhaps 100A DC total would do it, with 70A on one line as a rough guess.

  • @aaronbollinger5642
    @aaronbollinger5642 Год назад

    will the smart distribution panel work with the eco flo delta pro?

    • @kokomovans
      @kokomovans  Год назад

      No, that is a separate system

  • @normanroberts6241
    @normanroberts6241 Год назад

    Does the location of the fuse for the Alternator cable make any difference ?

    • @kokomovans
      @kokomovans  Год назад

      No, it just has to be somewhere between the ecoflow system and the van starter battery

    • @normanroberts6241
      @normanroberts6241 Год назад

      Thanks for your help @@kokomovans

  • @OliverMartens
    @OliverMartens Год назад

    Thx for your Video, good inspirations!
    i have a Power Kit Independence Kit with one 5kWh battery installed in my van.
    Unfortunately, I have noticed that the battery discharges by around 15% within 24 hours without a load being connected.
    I started on Sunday around 5pm with 50% capacity.
    Yesterday (Wednesday) only 6% charge remaining. No consumer used electricity during this time. Only DC was activated.
    Losing 44% of a 5 kWh battery in standby within 72 hours is not really energy efficient, is it?
    what is your experience?

    • @kokomovans
      @kokomovans  Год назад

      Hi Oliver, I’d see if you have a firmware update available and reach out to ecoflow about this through the customer service chat section on their app. This is abnormal and I’m sure it can be resolved.

    • @OliverMartens
      @OliverMartens Год назад

      @@kokomovans Thx for your reply!
      Firmware ist up to date... Fresh answer from Ecoflow-support: "The PowerHub will consume 20W of power when the DC output is turned on, in addition to the appliances. So it seems that the LFP battery loss is within the normal range."
      20 watts correspond to 480 watt hours per day, which means that the 5 kWh battery is empty after 10 days of idling at the latest...

    • @kokomovans
      @kokomovans  Год назад

      Interesting! I always have the systems charging with solar constantly so I guess I’ve never noticed it. Hopefully you’re able to leave the dc turned off when you’re not using it.

    • @OliverMartens
      @OliverMartens Год назад

      @@kokomovans Solar in sunny months may be no Problem, but during winter and rainy days... I need DC constantly for GPS, alarm and parking heater (remote start). With a normal Lifepo4 no problem for weeks in Standby. I should Charge and discharge the battery 2-3 times from 100%-0% now as a suggestion from ecoflow. I Just Start charging...

    • @kokomovans
      @kokomovans  Год назад

      On the few rainiest days that could be a problem but most cloudy days you still charge enough to counteract that small drainage as long as you don’t park under a tree. And yes a custom Victron system would definitely be better. The ecoflow system is for people that want the plug and play ability. I’ve personally never heard any of my customers having a problem with ecoflow though.

  • @tc.
    @tc. Год назад

    I’m planning to install an secondary 48V/100A alternator for charging. How does WS500 controller setup to work with PowerKit alternator charging?

    • @kokomovans
      @kokomovans  Год назад

      I’m sorry I don’t believe eco flow currently supports connecting to a wakespeed controller

    • @brucechen2388
      @brucechen2388 Год назад

      I Think it supports!

  • @RhodeyRepairs
    @RhodeyRepairs 7 месяцев назад

    Dude youre awesome

  • @mikepurnell5645
    @mikepurnell5645 Год назад

    What AC unit was that? Also, how long will the 10 kw system run it for?

    • @kokomovans
      @kokomovans  Год назад +1

      This one: amzn.to/3F0i5YS
      Ran it all night and the battery only got down to 60%

  • @kevinnussey5724
    @kevinnussey5724 9 месяцев назад

    Great video . Thanks.
    Do I have to use a 100 amp fuse for the alternator 6 guage line?
    I want to locate my fuse in the battery box with a simpler in-line set up and 100 amps seems like overkill.
    How about 40-50 amps?
    Thx

    • @kokomovans
      @kokomovans  9 месяцев назад

      You’ll want something higher than that because you’ll regularly be pulling roughly 70 amps charging from your alternator

  • @mjeanes4244
    @mjeanes4244 Год назад

    Thank you I did

  • @jimneumann6099
    @jimneumann6099 Год назад

    Instasubbed! ❤ Great and clear video

  • @JohnHenryEllis
    @JohnHenryEllis 10 месяцев назад

    Did I see Romax in this video?

    • @kokomovans
      @kokomovans  10 месяцев назад

      Yes Romeo wiring for the 120v system

  • @cody_hines
    @cody_hines Год назад

    Thank you for this video! Massive help🫡