Fuses vs circuit breakers

Поделиться
HTML-код
  • Опубликовано: 13 окт 2024

Комментарии • 23

  • @jasonvoorhees3282
    @jasonvoorhees3282 3 года назад +4

    That’s why fuse will always be my favourite circuit protector. Sure its one-time use, but the speed is enough to compensate for it

  • @tslimits
    @tslimits 6 лет назад +8

    Clear and instructive fuse protection primer. Thank you!

  • @SF-fb6lv
    @SF-fb6lv Год назад +1

    That was a super good video, thanks!

  • @echothehusky
    @echothehusky 6 лет назад +6

    Wait, at 21:07 the contactor does not close, the supply appears to have just been switched off to switch the lights off.

    • @Berkeloid0
      @Berkeloid0 5 лет назад +3

      Ha, it doesn't even budge, it really does look like it was staged!

  • @harip9159
    @harip9159 Год назад

    HOW TO SELECT THE SIZING OF SF UNIT FOR DIFFERENT HP MOTORS & DIFFERENT TYPES OF STARTING. ALSO THUMB RULE TO SF UNIT& MCB TO ALL STARTER PANELS.

  • @LTVoyager
    @LTVoyager Год назад +1

    Was that a type at the 8:50 point where a 200 kA fuse is shown for a 25 kA fault? I assume that was a 20 kA fuse as I don’t think a 200 kA fuse should blow under 25 kA of current.

    • @51TomasLopez50
      @51TomasLopez50 Год назад

      You didnt get the concept, thats interrupting power.

    • @LTVoyager
      @LTVoyager Год назад

      @@51TomasLopez50 Yes, I missed that. However, kA is a current rating, not a power rating.

    • @51TomasLopez50
      @51TomasLopez50 Год назад

      @@LTVoyager no man… the max rating to withstand that current. Not power a in watts.

  • @ActuatedGear
    @ActuatedGear 5 лет назад +3

    I can smell these tests.

  • @dalenassar9152
    @dalenassar9152 4 года назад +1

    Were these energy surges supplied by a capacitor?

  • @atomicdmt8763
    @atomicdmt8763 Год назад

    always use a fused disconnect for line side connections..........generally, correct?

  • @commenter5469
    @commenter5469 Год назад

    The only question is: where will you encounter such many hundreds folds of over current faults in contemporary grid, with so many safety devices up stream?!
    Primary to secondary fault of the service transformer?! With fuses on the feeder lines?!
    Not likely!!!

  • @derina.maleek9408
    @derina.maleek9408 3 года назад

    PERFECT

  • @michaelcostello6991
    @michaelcostello6991 7 лет назад +2

    Where are the cables shorted. Please show the wiring diagram

    • @Berkeloid0
      @Berkeloid0 5 лет назад +5

      They clearly show how each component is wired before each test. A wiring diagram wouldn't give you any additional information that you can't already see.

  • @paul_rosioru
    @paul_rosioru 3 года назад

    Cristal clear

  • @michaelcostello6991
    @michaelcostello6991 7 лет назад

    Very good

  • @marines1361
    @marines1361 7 лет назад

    exc