Ok bro itu correct tha but itu power factor lag mattu solli irukuga itu la lead tu iruku. But power factor very easy and small understandable video 👏👏👏
Thanks brother for taking your time to make everyone understand in simplest and easiest way. Bro can you explain about Starters, Synchronisation (Dark lamp & Bright lamp), How to test Preferential trip in a generator? I have few more doubts on marine electrical. Air circuit breaker?
Bro your example is ok,reactive power enga poguthu ila enga iruku plz give realize (imagination) example,active power nama use panrom but reactive power enga iruku, practical example solunga,I am asking from your example Flipkart, Amazon la nama kudukura delivery charges go to some one and it utilities by that person same thing Nan kekuren reactive power epadi use aguthu,reactive power enga wast aguthu,nenga solura example ah resistive load la epadi compare panuvinga,lot of doubt iruku,plz explain
ஒரு மின்சாதனத்தில் மின்னோட்டம் பாயும் போது அது தேவையான மின்சாரத்தை மட்டும் எடுத்து கொள்ளும் மீதி வீணாக வெளியேறும் மின்சாரத்தின் அளவு .01க்கு மிகாமல் பார்த்து கொள்ள வேண்டும் நான் படித்தது.
Hi, explain detaily for distribution transformer 4 wire system when one phase cut off on primary side What will changes in sec side, this is common for tneb side at peak hour
That time transformer one phase cut aagum. Other phase winding irutu magnetic flux ituku share aagum. Example R phase cut aana y phase irutu 50 % and B phase irutu 25% R phase kediakum. So output la R phase voltage kamiya kediakum, Y phase voltage la medium ma kediakum, B phase voltage Maita phase veda adigama iruku but pathadhu, load time voltage Fluxuation iruku.peak hour Fluxuation inu adigama load la work aagatu
1.Bro load (current) is depend upon secondary side of transformer(LT side).but first11kvline cubical energy meter ku vandhurku next vcb to primaryside of transformer ku vandhurku ippo eppadi measure pannum load? HT side voltage is more, current is low Thaney bro. 2.Bro secondary side of transformerku energy meter connection illey? nangey use panrey load cable secondary side thaney kudthurko happo eppadi measure aghum load. 3.Bro secondary side ley dhan load kudukorom load adhigama anal 11kv fuse(jumper)cut aghudhu bro Why? 4.Bro nangey Daily night 12oclk kwh, kvah meterley edukrom Adhil units consumption calculate panrom, meterku only eb side cable Dhan vandurku, load side cable Adhil illey secondary side transformer kudthurku, happo Andha meter Ht side measure panum ha 5.Bro EB side 11kv line kuday hevalo Amps kudukarangey 6.Bro transformer yarodey handover ku varum ? na work panrey site ka or EB side avngludha bro please Indha hella comment parthi oru video post panungey bro
Bro 11kv power step down transformer la 440 volta converrt panni vara currenta panel la trunking la konduvanthu anga erunthu eduthu capacitor use pannirkanga...so konjam theliva solunga
power factor improvement adhigama thaevai padra locationla synchronous motorah over excitation la run panni lineku parallelah connect pannalum power factor improvement aagum...
When we are consuming power or if we are being downstream then energy meter displays in negative if we are acting as upstream or if we provide power some one act as downstream then it ll display in positive which is +0.9 0r else
Sometimes power factor get lag, that usable power (real power) low and non usable power(reactive power) get high. So that time decrease reactive power by use that capacitor bank
தமிழில் படிக்கவில்லை ஆனால் தமிழில் விளக்குகிறீர், பரவாயில்லை, இந்த power factor என்பது தமிழில் "திறன் காரணி" என்று பெயர், இதன் அதிகபட்ச மதிப்பு ஒன்று. இது ஒரு மாறுதிசை மின்னோட்டதில் மின்னழுத்தத்திற்கும் மின்னோட்டத்துக்கும் உள்ள கட்ட(phase angle) வேறுபாட்டைப் பொருத்து இருக்கும், 90" என இருக்கும்போது திறன் காரணி ஒன்றாகும். Cos வருவது பற்றி எழுத தற்றபோது இயலாது நீங்களே படிக்கவும்!!.
அப்ப difference between real and apparent power is due to transmission loss னு சாெல்லவறீங்களா. அப்ப வீடுகளில் power factor 1 ஆக இருக்குமா. நீங்க சாெல்லற இந்ந definition புரியக்கூடியது. மற்ற சேனல்களில் நீங்க சாென்ன மாதிரி cosine of angle between voltage between current and voltage னு பதிவிடறாங்க. நான் BE electrical engineer. But கடந்த 24 வருடமா software industry ல இருக்கன் . Put more videos on electrical engg
@@Techdoct As a channel owner ,you should not get angry on subscribers you have to rectify or improve your the things,what i told just improve ,nobody is perfect.neenga build up kodukaama intha video potta naan yen ipdi comments podaporen
ha ha ha. Thanks for your comment..thambi oru thangala sollumpothu thappunu sollathenga....thapa sollunga..appathan nenga kathukida mudium..nobody is not perfect...I can not give you spoon feeding to you. engineer never tells its not correct, they tells it has to be correct...tell the mistake sir.....This is a natural way of techdoct presentation. techdoct never present like providing screen shot.....
Ok bro itu correct tha but itu power factor lag mattu solli irukuga itu la lead tu iruku.
But power factor very easy and small understandable video 👏👏👏
I've learned so much from you and want to learn lots of thanks nanpa....
எங்க போனீங்க ப்ரோ இவ்ளவு நாளும் சூப்பர் explain 👌👌👌👌👌👍
Clear cut explanation Sir, keep posting more videos....
Real power க்கும் apprant power க்கும் உள்ள விகிதம் power factor
Supper enkku theliva purinchathu
Thanks nanba..உங்கள் ஆதரவை தேடும் உங்கள் நண்பன்....
keep going.. good example..... cyrstal clear.. thanks.
Thanks brother for taking your time to make everyone understand in simplest and easiest way.
Bro can you explain about Starters, Synchronisation (Dark lamp & Bright lamp),
How to test Preferential trip in a generator?
I have few more doubts on marine electrical.
Air circuit breaker?
Super bro very good explanation
சூப்பரோ சூப்பர் ❤😂👍🙏🌹
Thanks, really useful this video
Sir ..... electromagnetic relay and induction relay detail video potunga sir
Super sir your expectations easy to understand
Great sir congratulations super
Now I clearly understand thanks brother
Sure nanba...நன்றி உங்கள் ஆதரவை நாடும் உங்க நண்பன்
Bro.. transmission lines la power loss epdi aguthunu konjam explain panuga please
Excellent video bro thank u
Really good video nanbaa💐💐💐
Good explanation
Bro your example is ok,reactive power enga poguthu ila enga iruku plz give realize (imagination) example,active power nama use panrom but reactive power enga iruku, practical example solunga,I am asking from your example Flipkart, Amazon la nama kudukura delivery charges go to some one and it utilities by that person same thing Nan kekuren reactive power epadi use aguthu,reactive power enga wast aguthu,nenga solura example ah resistive load la epadi compare panuvinga,lot of doubt iruku,plz explain
Super work 👏
Lagging and leading pathi podunga bro
perfect explanation...thk u bro
G oru applicationku electric motor epd select panrathu epd torque epd calculate panrathu.? Therinja sollunga boss
Sir 1587 fluke insulation testing megger epadi usu panrathunu podungka sir...
ஒரு மின்சாதனத்தில் மின்னோட்டம் பாயும் போது அது தேவையான மின்சாரத்தை மட்டும் எடுத்து கொள்ளும் மீதி வீணாக வெளியேறும் மின்சாரத்தின் அளவு .01க்கு மிகாமல் பார்த்து கொள்ள வேண்டும் நான் படித்தது.
எதைபற்றி படிக்கும் போது இதை பாதீர்கள்..நண்பரே
Sync meaning தேடும்போது
Bro ethu right aha
Thank you brother
Hi, explain detaily for distribution transformer 4 wire system when one phase cut off on primary side
What will changes in sec side, this is common for tneb side at peak hour
That time transformer one phase cut aagum. Other phase winding irutu magnetic flux ituku share aagum. Example R phase cut aana y phase irutu 50 % and B phase irutu 25% R phase kediakum. So output la R phase voltage kamiya kediakum, Y phase voltage la medium ma kediakum, B phase voltage
Maita phase veda adigama iruku but pathadhu, load time voltage Fluxuation iruku.peak hour Fluxuation inu adigama load la work aagatu
Super explanation nanba
One doubt ji. 20 real power. Apprant 23. Extra 3 is only loss other wise it affected supply system?.
சிறப்பு... ஆனால் கெப்பாசிட்டர் வால்யூ கண்டுபிடிக்க... டேபிள் பார்மூலா தான் தேவையா? இந்த பார்முலா எல்லாம் மறந்து விட்டது ஆனால் இப்போது தேவைபடுகிறது...
Thala....superrr....semiya purinjichuuu
Mass explain g..
Super Bro 💯💯
V.good explain
Bro all videos super i like
Power factor step pathi soluga ... Bro
Very very thanks bro
1.Bro load (current) is depend upon secondary side of transformer(LT side).but first11kvline cubical energy meter ku vandhurku next vcb to primaryside of transformer ku vandhurku ippo eppadi measure pannum load?
HT side voltage is more, current is low Thaney bro.
2.Bro secondary side of transformerku energy meter connection illey? nangey use panrey load cable secondary side thaney kudthurko happo eppadi measure aghum load.
3.Bro secondary side ley dhan load kudukorom load adhigama anal 11kv fuse(jumper)cut aghudhu bro Why?
4.Bro nangey Daily night 12oclk kwh, kvah meterley edukrom Adhil units consumption calculate panrom, meterku only eb side cable Dhan vandurku, load side cable Adhil illey secondary side transformer kudthurku, happo Andha meter Ht side measure panum ha
5.Bro EB side 11kv line kuday hevalo Amps kudukarangey
6.Bro transformer yarodey handover ku varum ? na work panrey site ka or EB side avngludha bro
please Indha hella comment parthi oru video post panungey bro
Thank u for ur posts nanba.
அருமை
VFD video podu ga sir
சூப்பர் bro
நன்றாக புறிந்தது
Super 💥
Bro 11kv power step down transformer la 440 volta converrt panni vara currenta panel la trunking la konduvanthu anga erunthu eduthu capacitor use pannirkanga...so konjam theliva solunga
yugesh.m yugesh.m demand raise aagama irukka
Power factor improvement pathi sollunga
Capacitor bank use panni power factor improvement pannalam
power factor improvement adhigama thaevai padra locationla synchronous motorah over excitation la run panni lineku parallelah connect pannalum power factor improvement aagum...
Super nanpa
super bro
super ji
Capacitor bank use in reactor ?
Fantastic bro
Bro pls explain thyristor function and IGBT
Sure nanba...நன்றி உங்கள் ஆதரவை நாடும் உங்க நண்பன்
thank you sir.
Super bro
Bro, am maintenance department. Some time energy meter displayed - Value of power factor(-0.98), How they are possible, explain details.
When we are consuming power or if we are being downstream then energy meter displays in negative if we are acting as upstream or if we provide power some one act as downstream then it ll display in positive which is +0.9 0r else
Spr explain
2hp motor க்கு power factor எவ்வளவு சார்
power factor video super power factor constant ya vaika mudiyuma pf=0.34 iruku ithu correct ya
pannalam..but switching the capacitor bank..
okay innu oru questions Answers bro
Antha triangle epdi podrathu? Ella PF kum diagram ipdi thaana?
athukku phasor value kandupidikkanum
PF= KW/KVA.
எத்தனை கிலோ வாட் பயன்படுத்துகிறோமோ அதே அளவுக்கு கெபாசிட்டர் பயன்படுத்த வேண்டும்.
அப்போது தான் PF -1- ஆக இருக்கும்.
Thanks sir daut clear
Thanks for your support
Bro apo Andha lag, lead, unity?
Thanks you
How capacitor bank used to compensate the power factor?
they connect parallel with ckts..Capacitor injects reactive power
OK bro thanks a lot
why not come neutral wire in ht lines
Soon I update nanba for you..
Sema bro
Grid na?
இங்க ஒரு மீட்டர் ல . KW = 19, kvar=23.3 , kvA =28.3 இதுக்கு power factor எவ்வளவு . . . .
Pf = 0.67
Super
Super video
Very useful to me
நன்றி உங்கள் ஆதரவை நாடும் உங்க நண்பன்
On delay timer off delay timer workking vetio potunga
Sir, Electricity Bill la "Power factor Penalty" nu oru penalty poduraangale, authu ethukku sir? Antha penalty ah avoid panrathu eppadi?
Avoid unnecessary using of inductive load like fan,mixer grinder and induction stove.
Nanba na padikkanum potulam ninga illema poidingale😘
Oru doubt?
Switch on capacitors more than requirements (over compensated) while power factor decrease what is the reason????
Sometimes power factor get lag, that usable power (real power) low and non usable power(reactive power) get high. So that time decrease reactive power by use that capacitor bank
Epdi bro real power calculate pandrathu
Tq
நாம லோடு அதிகமா எடுத்தா பவர் ஃபேக்டர் ரீடிங் என்ன வரும்
Tks
நன்றி உங்கள் ஆதரவை நாடும் உங்க நண்பன்
எந்த காரணத்துனால power factor generate ஆகுது
அது இல்லாம நாம power consume பண்ண முடியாதா
how to use in capacitor bank in commercial side
calculate the powerfactor to be improved watch this: ruclips.net/video/bZCEAn2dgtk/видео.html
I like tamil only
👌👌👌
தமிழில் படிக்கவில்லை ஆனால் தமிழில் விளக்குகிறீர், பரவாயில்லை, இந்த power factor என்பது தமிழில் "திறன் காரணி" என்று பெயர், இதன் அதிகபட்ச மதிப்பு ஒன்று. இது ஒரு மாறுதிசை மின்னோட்டதில் மின்னழுத்தத்திற்கும் மின்னோட்டத்துக்கும் உள்ள கட்ட(phase angle) வேறுபாட்டைப் பொருத்து இருக்கும், 90" என இருக்கும்போது திறன் காரணி ஒன்றாகும். Cos வருவது பற்றி எழுத தற்றபோது இயலாது நீங்களே படிக்கவும்!!.
your wrong
cos 90 = 0 cos o = 1
Hates off bro 😎
👏👏👏👏👌👌👌👌👌👍🙏🙏🙏💐💐
Bro nega reactive power patthi solla .so please
video available in techdoct
அப்ப difference between real and apparent power is due to transmission loss னு சாெல்லவறீங்களா. அப்ப வீடுகளில் power factor 1 ஆக இருக்குமா.
நீங்க சாெல்லற இந்ந definition புரியக்கூடியது. மற்ற சேனல்களில் நீங்க சாென்ன மாதிரி cosine of angle between voltage between current and voltage னு பதிவிடறாங்க. நான் BE electrical engineer. But கடந்த 24 வருடமா software industry ல இருக்கன் . Put more videos on electrical engg
Ur showing wrong example
No..It is correctly only...ok then how are you saying this is wrong example...
சார் கத சொல்லாம மேட்டருக்கு வருவோம்
Wrong examples sir..
Not good
Itha thaan pala video refer paningala bro ipdi mokka pantingale.im expecting more from u
Hi einstein .....ithukkumelana nega than enthavathu kandupidikkanum......book ah pathuddu..itha compare pannathenga...
hey..it is good explanation only..if you know leave it..you may have good knowledge in electrical..for us it is good...
It is better than other channel video..
@@Techdoct As a channel owner ,you should not get angry on subscribers you have to rectify or improve your the things,what i told just improve ,nobody is perfect.neenga build up kodukaama intha video potta naan yen ipdi comments podaporen
ha ha ha. Thanks for your comment..thambi oru thangala sollumpothu thappunu sollathenga....thapa sollunga..appathan nenga kathukida mudium..nobody is not perfect...I can not give you spoon feeding to you. engineer never tells its not correct, they tells it has to be correct...tell the mistake sir.....This is a natural way of techdoct presentation. techdoct never present like providing screen shot.....
Please speech well, your explanation is bad.. 😕😕😕
nanba nanba nu sollatha bro cringe ja iruku
Super bro
Super
super anna
Super explanation thank u brother...