Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
I have recently purchased maxpower PV 7000 hybrid inverter along with 6 KW solar plates. My question is that can I have an on grid system along with a conventional UPS (for back up of fans) with this inverter?
Bs yeh ek sawal e hai halanky kuch Discos me single phase pe b hoti hai. Yeh sirf is liye hai k khud se load management nhi krna chahty warna divide ho e skta hai.
Thank you for your response. Please do tell me can I operate this inverter in Hybrid mode without batteries? Which mode should I select in the inverter settings for this? I want my normal load (refrigerator, water condenser, 1.5 Ton inverter AC, 2 ceiling fans, LED TV along with LED lights) to be on solar during the day. If solar output is reduced, inverter should automatically switch to WAPDA. If there is loadshedding, I want my conventional UPS to take over. Kindly guide me
Maray zahen may question ha agr ap bta sktay han? Dual output valay inverter use kr Raha hon, light oor heavy load ka 2 pole changeover may Kisi bhi aik changeover ko bypass karo tu wapda ki neutral maray solar inverter Kay sat common ho jati ha, load side pr single neutral installed ha, Asa Kiya Kiya jay Kay change over pr neutral na common ho wapda Kay sat ?
@@AllRoundWiz Nahi bhi ap smjhay Nahi, jb ap 2 pole change over may agr Heavy load ko bypass krtay ho, tu wapda ki neutral hamaray load Kay neutral say mil jati ha, oor asay may light load ka changeover phlay hi inverter ki neutral pr hota ha, ab Kun Kay neutral single wire Vali ha, tu asay may wapda ki neutral oor inverter ki neutral common ho jati ha , Matlab ya neutral us waqat common ho jati ha jb aik changeover wapda pr ho oor dosra changeover inverter pr ho.
Sorry me ab samjha hn aap ki baat. Is case me possible nhi hai neutrals ko separate rakhna kyun k single wire k case me. Generally 2 wires daali jaati hain neutral ki isi case se bachny k liye. Agr aap ki single wire hai to aap ki neutral waise b common e ho g wapda k sath kyun k aap ka koi load to directly Wapda pe ho ga e aur neutrals common ho gyi hon g beshak water pump e ho aap k main DB box me common ho jata ho ga. Aap ko ek extra neutral hr jagah pohanchani pary g light aur heavy load ki. Phr e aap separate kr sken ge.
@@AllRoundWiz vasay asay may 3 phase changeover use kr sktay han, yani light load oor heavy load dono ko aik 3 phase changeover laga kr, asay may neutral common Nahi ho gi, during changeover, bus ferk ya ha Kay Light oor heavy ka aik hi 3 phase changeover ho ga,
The way you simplify complex concepts about our solar system is truly remarkable. It's like having a personal guide through the cosmos. Keep up the fantastic work, and thank you for making learning about space so accessible and enjoyable!
Great Job 💖
Keep up the good work 😇
Inverter ( maxpower pv 5000 pro)
Battries 02 tubular 200am
maine SBU mood select kiya hoa hy hy
11....Wapda se battery charging 10amp hein.
12....23v pe wapda se charging lega select hy.
16 ...CSO mood select hy
26 ..Bulk charing ( 28.4v)
27....flot charging ( 27v)
29......( light load 21.4)
Heavy load cutt off ( 23.8)
Heavy load restart ( 24.5 ) hy ..
Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta .
Mahrbani farma k setting thek kerwa dein shukria
I have recently purchased maxpower PV 7000 hybrid inverter along with 6 KW solar plates. My question is that can I have an on grid system along with a conventional UPS (for back up of fans) with this inverter?
Yes you can if your city's Disco allows single phase net metering.
@@AllRoundWiz thank you very much for the help.
@@AllRoundWiz why single phase? Why not 3 phase?
Bs yeh ek sawal e hai halanky kuch Discos me single phase pe b hoti hai. Yeh sirf is liye hai k khud se load management nhi krna chahty warna divide ho e skta hai.
Thank you for your response. Please do tell me can I operate this inverter in Hybrid mode without batteries? Which mode should I select in the inverter settings for this?
I want my normal load (refrigerator, water condenser, 1.5 Ton inverter AC, 2 ceiling fans, LED TV along with LED lights) to be on solar during the day. If solar output is reduced, inverter should automatically switch to WAPDA. If there is loadshedding, I want my conventional UPS to take over. Kindly guide me
What about solax power 6w ip65 hybrid which is about 275-280
And its is a proper brand which make its own inverter
Their inverters are good but in the same range their price is high comparatively.
Maray zahen may question ha agr ap bta sktay han?
Dual output valay inverter use kr Raha hon, light oor heavy load ka 2 pole changeover may Kisi bhi aik changeover ko bypass karo tu wapda ki neutral maray solar inverter Kay sat common ho jati ha, load side pr single neutral installed ha,
Asa Kiya Kiya jay Kay change over pr neutral na common ho wapda Kay sat ?
Aap ne konsa changeover breaker use kia hai? Two pole waly me neutral common nhi hoti.
@@AllRoundWiz Nahi bhi ap smjhay Nahi, jb ap 2 pole change over may agr Heavy load ko bypass krtay ho, tu wapda ki neutral hamaray load Kay neutral say mil jati ha, oor asay may light load ka changeover phlay hi inverter ki neutral pr hota ha, ab Kun Kay neutral single wire Vali ha, tu asay may wapda ki neutral oor inverter ki neutral common ho jati ha ,
Matlab ya neutral us waqat common ho jati ha jb aik changeover wapda pr ho oor dosra changeover inverter pr ho.
Sorry me ab samjha hn aap ki baat. Is case me possible nhi hai neutrals ko separate rakhna kyun k single wire k case me. Generally 2 wires daali jaati hain neutral ki isi case se bachny k liye. Agr aap ki single wire hai to aap ki neutral waise b common e ho g wapda k sath kyun k aap ka koi load to directly Wapda pe ho ga e aur neutrals common ho gyi hon g beshak water pump e ho aap k main DB box me common ho jata ho ga. Aap ko ek extra neutral hr jagah pohanchani pary g light aur heavy load ki. Phr e aap separate kr sken ge.
@@AllRoundWiz vasay asay may 3 phase changeover use kr sktay han, yani light load oor heavy load dono ko aik 3 phase changeover laga kr, asay may neutral common Nahi ho gi, during changeover, bus ferk ya ha Kay Light oor heavy ka aik hi 3 phase changeover ho ga,
@Voxoe yeh kaam to phr aap manually b kr skty hain, 2no changeover ek e time pe kr den switch.