- Видео 115
- Просмотров 184 342
All Rounder
Пакистан
Добавлен 29 фев 2024
Solis 6KW IP66 Inverter Prices Drop! | Unboxing & New Features of Solis 6KW Plus
In this video, we discuss the significant price drop of Solis 6KW IP66 inverters, which were previously priced at 345K and are now just 275K. Other IP21 inverters have also seen a price reduction, now around 175K. When the price difference is so small, it's worth opting for the IP66 model due to its advanced features. I’ve also shared the unboxing and detailed screening of the new version of Solis 6KW Plus, which comes with a screen and more. Watch this video to learn why upgrading to IP66 is a smart choice for your solar setup!
Просмотров: 1 508
Видео
Why are they adding meter rent fix charges on net metering consumer's bills
Просмотров 2033 месяца назад
Why are they adding meter rent fix charges on net metering consumer's bills
HikVision 2MP Camera & DVR Unboxing | DIY Installation | Setup with 8-Channel DVR
Просмотров 1313 месяца назад
In this video, we take you through the unboxing and complete A-Z installation of a HikVision 2MP analog camera with an 8-channel DVR. Whether you're setting up a security system for your home or office, this step-by-step guide covers everything you need to know, from unboxing to wiring, setup, and configuration. Perfect for DIY enthusiasts, this video ensures you have all the information you ne...
3-phase on-grid inverter & single-phase hybrid inverter installation | Nitrox 6kW | Solis 10KW
Просмотров 9044 месяца назад
In this video, we provide an in-depth look at the installation of a 10KW on-grid three-phase inverter alongside a single-phase hybrid inverter. We explain the optimal setup, detailing why you should install a higher number of panels on the hybrid inverter and the rest on the on-grid inverter. Additionally, we highlight a fault in Osaka batteries where a terminal broke and demonstrate how to pro...
IP21 Inverters Settings | Battery | No Battery | Net Metering | Maxpower | Fronus | Primax | Inverex
Просмотров 4144 месяца назад
In our latest video, we dive into the detailed settings of IP21 inverters, providing a comprehensive guide for users in various scenarios. Whether you're operating in battery mode, without a battery, or as a net metering consumer, we explain the optimal settings to ensure efficient performance and energy management. Learn how to configure your IP21 inverter to maximize its potential, save on el...
Lead Acid vs. Used Lithium Battery: Performance Comparison Never buy Lead Acid for 48V/24V Systems
Просмотров 3374 месяца назад
Second-Hand Lithium Battery: Should You Buy It? Full Load Test & Comparison with Lead Acid batteries ruclips.net/video/Ks3B5iGy1dA/видео.html In our latest video, we compare the performance of Lead Acid batteries and used Lithium batteries using two identical inverters in battery mode. See the stark difference as the Lead Acid battery drops to 49V in just 90 minutes, while the Lithium battery i...
Second-Hand Lithium Battery: Should You Buy It? Full Load Test & Comparison with Lead Acid batteries
Просмотров 1,5 тыс.4 месяца назад
Second-Hand Lithium Battery: Should You Buy It? Full Load Test & Comparison with Lead Acid batteries
Best Way to Install UPS with MPPT Controller | Future-Proof Setup for Solar Inverter Upgrade
Просмотров 1 тыс.4 месяца назад
Best Way to Install UPS with MPPT Controller | Future-Proof Setup for Solar Inverter Upgrade
Save 45-60 Units Monthly with Solar Supply Priority Setting | LBU vs BLU Explained
Просмотров 8034 месяца назад
Save 45-60 Units Monthly with Solar Supply Priority Setting | LBU vs BLU Explained
Nitrox 12KW Installation Guide: Wiring, Battery Setup & Essential Safety Measures
Просмотров 5195 месяцев назад
Nitrox 12KW Installation Guide: Wiring, Battery Setup & Essential Safety Measures
Essential Protection Devices for Your Solar Setup DB | 3KW, 6KW, 8KW & UPS with MPPT
Просмотров 2415 месяцев назад
Essential Protection Devices for Your Solar Setup DB | 3KW, 6KW, 8KW & UPS with MPPT
Solis 6KW IP65 Hybrid Inverter Unboxing | First look
Просмотров 7755 месяцев назад
Solis 6KW IP65 Hybrid Inverter Unboxing | First look
Solar Tracker, VFD for Tubewell & Desi Inverter for Home Load
Просмотров 3065 месяцев назад
Solar Tracker, VFD for Tubewell & Desi Inverter for Home Load
Solis 5KW Off-Grid Inverter Unboxing | Transforming to Hybrid with Firmware Upgrade
Просмотров 2,1 тыс.5 месяцев назад
Solis 5KW Off-Grid Inverter Unboxing | Transforming to Hybrid with Firmware Upgrade
Misconceptions while selecting battery or solar inverter | 24V vs 48V | Tubular vs Lithium
Просмотров 1 тыс.5 месяцев назад
Misconceptions while selecting battery or solar inverter | 24V vs 48V | Tubular vs Lithium
Best settings for hybrid inverter used with battery | SBU mode | Prolong battery life
Просмотров 3,1 тыс.5 месяцев назад
Best settings for hybrid inverter used with battery | SBU mode | Prolong battery life
Solis 6KW hybrid inverter installation | Zero export | Perfect working of SUB mode without battery
Просмотров 17 тыс.6 месяцев назад
Solis 6KW hybrid inverter installation | Zero export | Perfect working of SUB mode without battery
How to do AC, DC and lightening arrestor earthing bore | DISCOs regulations
Просмотров 2756 месяцев назад
How to do AC, DC and lightening arrestor earthing bore | DISCOs regulations
Maxpower Suntronic 7000 pro | Testing real time sharing | Wapda consumption
Просмотров 7 тыс.6 месяцев назад
Maxpower Suntronic 7000 pro | Testing real time sharing | Wapda consumption
Maxpower Suntronic PV7000 Pro Unboxing | New vs. Old Model Comparison | Primax & SolarMax Review
Просмотров 9 тыс.6 месяцев назад
Maxpower Suntronic PV7000 Pro Unboxing | New vs. Old Model Comparison | Primax & SolarMax Review
IP21 Inverters: Anti-Dust Filter Cleaning & Optimal Installation for Maximum Solar Efficiency
Просмотров 6 тыс.6 месяцев назад
IP21 Inverters: Anti-Dust Filter Cleaning & Optimal Installation for Maximum Solar Efficiency
Update on Maxpower PV7000 Real-Time Sharing Issue | Awaiting Technical Team Feedback
Просмотров 4656 месяцев назад
Update on Maxpower PV7000 Real-Time Sharing Issue | Awaiting Technical Team Feedback
Workaround for Real time sharing WAPDA consumption issue | SUB Fault | Maxpower | SolarMax | Knox
Просмотров 2,7 тыс.6 месяцев назад
Workaround for Real time sharing WAPDA consumption issue | SUB Fault | Maxpower | SolarMax | Knox
Maxpower PV7000 | 6KW installation | Fault with Real time sharing | SUB Fault
Просмотров 9 тыс.6 месяцев назад
Maxpower PV7000 | 6KW installation | Fault with Real time sharing | SUB Fault
Elevated Solar Structure & Civil Work: Future-Proofing Your Installation for 25 Years!
Просмотров 6837 месяцев назад
Elevated Solar Structure & Civil Work: Future-Proofing Your Installation for 25 Years!
RAF Infrared Cooker Unboxing & Demo | Induction vs Infrared Cooker | Best option for solar consumers
Просмотров 1,4 тыс.7 месяцев назад
RAF Infrared Cooker Unboxing & Demo | Induction vs Infrared Cooker | Best option for solar consumers
Govt is going to impose tax on solar | 2000 Rs per KW for 12KW+ Setup | Residential & Commercial
Просмотров 1867 месяцев назад
Govt is going to impose tax on solar | 2000 Rs per KW for 12KW Setup | Residential & Commercial
Answers to all your questions about Solar system | From MPPT to Inverter
Просмотров 3757 месяцев назад
Answers to all your questions about Solar system | From MPPT to Inverter
Customizing L3 Galvanized Structures: Resolving Boundary Wall Shadow & Space Saving Solutions!
Просмотров 2027 месяцев назад
Customizing L3 Galvanized Structures: Resolving Boundary Wall Shadow & Space Saving Solutions!
Solis 20KW On grid inverter with Jinko N type 36 panels | Complete installation
Просмотров 3247 месяцев назад
Solis 20KW On grid inverter with Jinko N type 36 panels | Complete installation
ip66 solis plus with screen 6 kw rate? final rate?
Bro how to use single phase hybrid in 3phase dp so that during loadshedding it will provide electric to all phases
Aap ko three phase breaker k Input pe Inverter ki output ko loop krna pary ga. Phr agr aap k pas three phase meter hai ek aur dusra single phase to aap changeover use kr skty hain.
Solis vs nitrox konsa acha hai?
Both are good but Solis has the edge.
Jis chhat me itnay hole drill ho jayen us ka kya banay ga.
Agr us pe block ban jaaty hain to koi farq nhi parta. Otherwise pani se issue to ho ga e.
@AllRoundWiz block bhi baaz oqaat chhat ko chhor detay hain, pata naheen chalta. Drill agar chhat me dalee bijli ki taaron ko lag gayee to naya masla. Behtar hai 4 inch ka block bana kar is me drill karain.
G aise kia ja skta hai. Lekin actually jo drilling hoti hai us me pehle tile phr mitti hoti hai to Lentar tk hardly jata hai kuch jaghon pe. Personal decision hota hai yeh to owners ka.
Hi sir iam from India kerala how I can software upgrade PV+ hybrid inverter because some times breaking pv production
With out bettery working or not only pv py kam kary
Only PV isnt recommended for any of the inverters. This one works with higher DC voltage Around 400 watts but when load connected is way less.
Bhai ye sab process hogaya par device show nahi horaha plz bata de kya masla hosakta hai?
Agr device show nhi ho rahi ya offline hai to pehle inverter ki settings me se Date time ko update kr den. Then agr is app se nhi ho rha to same login se Solarpower app se ek bar try kren aur phr dubara login kr len isi pe.
I have a problems which is batery reading not shows? ? Do you now how why??
On home page you can click on data settings to show battery values. Or you can get those from details tab.
Net metering case ma Daily Unit production nhi show hu raha ,????help plz
Daily production to aa rahi hoti hai app me. Details me b dekh skty hain aur statistics me b. Lekin us me se kuch aap k load ki taraf chala jata hai aur kuch wapda ki taraf to usey sırf Green meter ki 8 aur 9 number reading me e dekha ja skta hai.
Sir plz number chaiye
Sir apka number chaiye
Humy tu 8000 ata ha tx
Inverterzone best app he. Or hr hybrid inverter pr chalti he bs com port hona chahiye
Need at Jamshoro
Great video. I was searching this video. No load on wapda.
Glad I could help.
Hello, for sako inverter How to open the same datalogger on different device? I tried the same method but it doesn’t appear on the second phone
Bhai daily unit genration and unit feed to grid ka option kesy aye ga?
Generation e aati hai in inverters me. Feed us me se kitny hue wo nhi pta hota kyun k some of them go to load directly without reaching Green meter.
Asalam brother agr ham ic ki solar limit sy zayada load dalin to kia ya inverter wapda sy share kry ga ?
Nhi. Overload ho jaye ga. Maximum output se zyada nhi daal skty load.
Thanks for sharing. it helped me today
Glad it helped.
Do you have 8kw Solis hybird ? Their is news that the newer model ( with Display ) are coming next month
Yeah hope so. We dont sell.
Bro wht is current price ?
Around 270-275K
Without battery yani only solar kaam karta hy ya nahin.
Structure me maar khaa gae ap, inverter ki price nahi btai bro
Is waqt around 270-275K
When will its screen model will be launched in Pakistan?
I am not sure. It's still not available. Maybe in a couple of months.
Buts its launched already. Just not available.
@@AllRoundWiz ok
I have goodwe Inverter...ye is app pe kray ga Kam?
You will have to try. I am not sure.
Most useful and informative
Bhai ye ss k rawal bolts ni hen no jhoot
You are right. Nut bolts he meant.
Bhai 120k ma 55amp wo b used battery lene ka kia faida. Dyness 100 amp 5 year replacement warranty ma 248k ma mil rahi ha
G brother but price b range se bhr chali jaati hai. Mene comparison lead acid se kia hai. Recommended to new e ho g if someone can afford. Battery is working well for me so far. Let's see aagy kese chalti hai.
AOA.bhai mujhy inverter ki setting check krni hy k konsi setting ki hui hy company ny.plz chk krny ka procedure bataen
Enter wala button press kr k rakhen aur up/down se sb settings dekh len ya Manual pe default dekh len.
Apny is ki setting main battery type konsi rakhi hai kon si rekhy
User rakhi hai kyun k User defined settings k liye User hona zruri hai warna wo settings work nhi krti. Predefined hoti hain for certain battery types.
Bro datalogger show hora lakin aise hi device add ki lakin device add bhi hogai phr bhi show nhi hori. Any solution?
Ok try to add from Solar power app and then it will show up in smartEss automatically. No need to do anything extra.
Acha explain kia apny
Thanks brother.
Zaber dast
Bhai muj se ye action he ni ho rhe
What issue are you facing? Please send a voice note on WhatsApp number. Try watching the full video first.
I installed maxpoer 4kw 5000pv recently with 8 panels and 2 Tumblr batteries 185 ampare phoenix. Mughy plz batain k din k time kya ye wapda se bhi kuch bijlinleta hay.. or sham may ye batteries se on rehta hay ya wapda.. ? 2ndly ye k maughy samaj nai aa rha ye thori dsir battery pay chalta hay phir is k baad ye realtime shearing pe aa jata hay. For example mera load 500 chal rha bay to ye 2.5 wapds se leta hay as per breaker meter or baki batteries se.. or ye chez aglay din suba tak rehti hay or agar may batteries ka breaker band kardun to breaker meter pe load achanak se 500 ho jata hay. To mughy ye bayain k kya ye sahi hay or kya is dr meri bijlinpori raat half battery or half wapda pay hoti hay or is tarhan se saving bhi hoti hay.. plz guide brother 🙏
ruclips.net/video/d8ezJ-PvmUk/видео.html
Watch this video and do your settings according to your needs.
@@AllRoundWiz bohot farig video thi.. tumhay sawal hi samaj nai aya
I am using EnergyMate to monitor my Maxpower Suntronic PV 6000 Pro inverter. It shows the real-time graphs of energy (kW) produced during the day, but it doesn't tell me any information about the electricity generation (kWh) for the day, week, or month. Those graphs are blank. Same thing with SmartESS. Is there a way I can get these parameters as well from the inverter so I can monitor the generation in a better way? Thanks
This info is not available for these inverters or any inverter which doesnt have a CT.
Roti Ban sakti hai kya ?
Hum to nhi ís liye use krty lekin RUclips pe mene dekha hai logon ko is pe Roti bnaty.
assalamualikum bhai !!! Is masla ka kuwe hal ha bhai thanks ...
Wasalam. No, battery is the only solution.
Gujranwala mein banta hai yeh
Sahee.
Sir isme i think net metering nhi hy jo system apny show kia hy …or agr net metering ho to phr bhi PV plates utni hi generation kry gi jitna load ho ya phr different scenario ho ga ? Means agr kW generate ho rhy hain for example or 2 kw use ho rhy hain to baki 1 kW export ho jay ga ?actually me ny setup lgaya jisme net metering bhi hy or 6kw ka solis k sath 10 plates hain without batteries so kya me chota load ispy use kr skta hon during wapda off ?
Aap use kr skty hain agr 10 panels ek string pe hain lekin phr b tripping issue rehta e hai. Recommended nhi hai single source pe chalana. Secondly agr export on ho g to maximum generation ho g. Jo load se zyada ho g export ho jaye g.
Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
Inverter ( maxpower pv 5000 pro) Battries 02 tubular 200am maine SBU mood select kiya hoa hy hy 11....Wapda se battery charging 10amp hein. 12....23v pe wapda se charging lega select hy. 16 ...CSO mood select hy 26 ..Bulk charing ( 28.4v) 27....flot charging ( 27v) 29......( light load 21.4) Heavy load cutt off ( 23.8) Heavy load restart ( 24.5 ) hy .. Problem ye hy k heavy load (AC) din pe solar pe chalta hy lakin rast ko nahi chalta jab k AC haier ki device pe lga jo k 4 amp leta bus...phir b nahi chlta . Mahrbani farma k setting thek kerwa dein shukria
Which app are you using to monitor the power generation and consumption? Also, does it tell how much electricity in total it has generated (fed to grid)? I have PV 6000 Pro installed and in the app, these values are blank. Wondering if there's a way to turn these measures on.
I am using SmartEss but there are some limitations in this inverter, some of the parameters which we see in IP65 inverters aren't available in this.
Ji bhai aya koi solution iska
Nhi brother.
I know this is irrelevant to this video, but I must find an answer: I recently purchased MaxPower PV7000 2024 (LCD/Touch display) inverter, and overall, my experience has been good. However, while monitoring various parameters in the "Analysis Tab" of the SmartESS Solar app, I noticed that my battery discharges intermittently/irregular interval even when the Grid (WAPDA) is available. I have set the battery to not be used as the preferred source, with Utility (WAPDA) as the preferred source when solar is unavailable. This discharging usually occurs when solar energy is not available, such as from 6 PM to 6 AM or during early mornings and at night. Could you please explain why the battery discharges even when Grid/WAPDA is available? Additional Information: The battery discharge rate never exceeds 1 amp; it typically discharges at 1 amp or less for about 30 minutes to an hour. My source priority is set to Solar - Utility - Battery. I am using 4 batteries with a capacity of 100 amps each. The battery charging source is set to Solar Only, meaning the battery never charges from the grid. If battery is 100% at 6pm and there happens no WAPDA cut-off at all till morning, the battery % at 6am is 85-90% which means it consumes battery or discharges 15% on average each night without any actual load on battery due to unknown reasons. I would appreciate your insights regarding this issue.
Is this possible to access the solar inverter info via web? Android apps are fine but I am curious if web apps/interface are also available? Thanks
Yes, you can connect it to your computer using cable and use the software provided in the CD,
@@AllRoundWiz thanks, but any website available for this? Since it uses centralized database than it's possible that there maybe some web clients out there available for it.
Asalam O alekum, I recently purchased this inverter, and overall, my experience has been good. However, while monitoring various parameters in the "Analysis Tab" of the SmartESS Solar app, I noticed that my battery discharges intermittently/irregular interval even when the Grid (WAPDA) is available. I have set the battery to not be used as the preferred source, with Utility (WAPDA) as the preferred source when solar is unavailable. This discharging usually occurs when solar energy is not available, such as from 6 PM to 6 AM or during early mornings and at night. Could you please explain why the battery discharges even when Grid/WAPDA is available? Additional Information: The battery discharge rate never exceeds 1 amp; it typically discharges at 1 amp or less for about 30 minutes to an hour. My source priority is set to Solar - Utility - Battery. I am using 4 batteries with a capacity of 100 amps each. The battery charging source is set to Solar Only, meaning the battery never charges from the grid. If battery is 100% at 6pm and there happens no WAPDA cut-off at all till morning, the battery % at 6am is 85-90% which means it consumes battery or discharges 15% on average each night without any actual load on battery due to unknown reasons. I would appreciate your insights regarding this issue.
Brother app ka rabta contact nmbr share krna plz
In the description. WhatsApp messages only.