Solis 6KW hybrid inverter installation | Zero export | Perfect working of SUB mode without battery
HTML-код
- Опубликовано: 31 май 2024
- Whatsapp messages only: +923366630708
In this detailed video, we demonstrate the installation of the Solis 6KW Hybrid Inverter, showcasing its zero export capabilities and perfect SUB mode operation without a battery. Learn how to add a CT (Current Transformer) to make it function as an on-grid inverter while maintaining zero export to the grid. Discover our innovative solution for running the Solis 6KW inverter without a battery, overcoming the common issue of it not turning on without one. Whether you're an installer or a solar enthusiast, this video provides essential insights and practical solutions to optimize your solar setup. Watch now and unlock the full potential of your Solis 6KW Hybrid Inverter! - Наука
Welldone 👍
Kammal ka structure bnaya hai.
Thank you brother.
Great!!!!
Thank you.
Nice ❤
Good going brother ❤
Thank you.
Nice work, by the way maxpower pv7000 me bi ehsy hi 6 6 ki parallel me lag sakti hen?
Us me parallel aap uper e kr len. Neeche string laany ki zrurt nhi hoti.
Sir iski setrings ki detail video bnayain jis m hr setting ko describe kiya gya ho
Sure.
Bro where i should connect the (ac) air conditioner wire
In grid or gen
Generator and make it smart load from settings.
same case ham na bhi kia ha is k sath. without battery but all load is on backup load. and PV k na hote hue bhi wapda se chalta ha. and zero export k lie app k andar allow export ki option off kar sakte
اسلام و علیکم بھائی میں نے بھی اس انورٹر کو بغیر بیتری استعمال کرنا ہے پر یہ software per status off show کر رہا ہے مجھے اسکی setting بتا سکتے ہیں اور اسکی ct تو لگنی ہی grid کی phase wire پر ہے مجھے اسکی سمجھ نہیں ائی
@@imranrizvi8006 wiring Ka Kaam to engineer na Kia tha to us Ka mujhe Nahi pata ziada .. lekin ye wapda bagher Nahi chalta .. ya to battery ya wapda laazmi ho to tab solar use Kar sakte is mein
Sir isi tarhn ka koi 24v hybrid inverter bta dain jo wapda se real-time shairing k doran fazool ki consumption na kry.
Batteries k sath SBU Ya phr Nitrox 3KW
What's app number mil sakta hy inverter ki information chahye brother@@AllRounder-1133
Bhai CT kidr lagne ha kindly guide karn mane abe ct inverter sa ju phase wire niklte ha os per lagge ha CT inverter or Ac DP box kay mid ma lagye ha direction AC Dp box ki side per ha
Bhai CT aap ne connect krni hoti hai us wire pe jo Meter se aa rhi ho kisi b load se pehle. Aap k main breaker k pas lgayen usey jo bijli ki wire ghr me aati hai us pe Phase pe Arrow meter ki taraf ho.
Aoa Sir Eid Mubarak, can you please guide me regarding following :-
1) Which Solar inverter in 6kw IP 65 is good feature wise Solis or Solax.
2) Which Lithium battery in 100AH is good.
Quality wise solis would be way better than solax. Solax is associated with fronus and fronus has very bad reviews
No experience with Solax. So can't really comment on that.
Bro Solis is far better world wide brand It competes inverex and is much better. The only issue is limited service centers in Pakistan.
As for as battery is considered I suggest you to buy Solar Max Lithium ion battery 105 amp with 7000 life cycle the latest technology.
sirf solar panel ki input par to nahi chaly ga ye , to is pe perfect working kia huwi ct to har ip65 inverter ky sath ata ha and khudi pv and wapda ki realtime sharing ko manage karta ha
One of the subscribers have used it with just PV when solar panels are 8 or more. Wapda se kuch na kuch consumption hoti hai dusry inverters k feedback k mutabiq. Is me zero thi.
Assalam o Alikum. Brother mera 8 kw Solis hybrid hai with 16 Jinko 585 panels. MashaAllah buhat achi output aa rahi hai. Actually jo issue aa rha hai wo yeh hai k jb light jati hai or wapis ati hai tou ius my Thora issue aa rha. Hmary ghr k load ni chlta. Usky liye Input breaker ko down kr k up krna prta hai or us my bh kafi time k bad load on hota hai ghr ka. Installer se bat hoi. Wo khty hn k batteries must han is k liye. Jb k hybrid k suna tha k battery ki zarorat ni prti. Please guide kr den
Sir WhatsApp pe msg kren aap ko voice note bhej deta hn. Actually aap ko installation change krni pary g. Number in description.
Aoa Sir, Solis 6KW invertor k sath AKcome 700W bificial panels laga sakty hain
Yes brother.
@@AllRounder-1133Thanks for your feedback. I am interested to install 6KW solar system at my home. Can you please provide your services. How can i contact you.
Mein ny yahi inverter lagaya hya hy with 12 PVs. Ap ny SUB mode kaisy configure kia hy? Please guide kr dein. Mjhy settings nhi mili kafi dhonda. Currently mera inverter mode SBU chal rha hy, isko mein ny SUB krna hy.
Dosra, hmari taraf wapda voltage kafi low hoti hy 185V ~ 205V k bech. Inverter ki output 235V py set hy. Jb light chali jati hy tu inverter 230V~235V daita hy, Lekin Wapda k hoty huay inverter output 190V ~ 205V k bech ajati hy, byshk Solar generation ya battery sy he ghr ka load chal rha ho. Agr apko ye setting b maloom hy k inverter output voltage hamesha 230V~235V rahy, Wapda sy jitny marzi Volts arhy hon tu please wo b bta dein.
Please text on WhatsApp.
Sir kia hum CHOTI batteries Laga sakhty Hy 6kw ke system ke sath... 100 amp ki 4 batteries Laga sakhty hy
G lga skty hain bs settings me se charging amps kam kr den aur DC cut off voltage bht low na rakhen. Behtreen chalen g.
@@AllRounder-1133 thank u so much
Toh kia jab wapda load shedding se band hogi. To kya solar production band ho jae gi. Matlb ye as ongrid work kry ga without battery?
Mene 8kw ka solis purchase kiya hai.
If you have more voltage interns of panels. It may work but there are chances of tripping.
Apki CT theek kaam kr Rahi he means jitna load grid ko ja Raha hota he wo app pr show krta he?
Salam dear Kiya ap is k parameters ki videos shared Kar skate Hain complete
Wasalam. Please message on Whatsapp.
aoa sir!
hamne SOlis hybrid 6KW lagwaya ha , but vo wapda se light ni le raha, Dc pump on krne pe trip ho jata ha, is mn kya issue ho saqtaa ?
Wasalam. Whatsapp pe video bna k bhej den, aise idea nhi ho ga aap k sawal ka.
Total cost of complete system? Inverter price?
Inverter cost is 340K
Sir please Mera reply de g a ga.
Meray pass Inverex verion 6k Joa K 8 pannels 585 watt K Hai Laga hova Hai.
Day time main jub PV enough generate ho rahi Hoti Hai toa meter Sa b 0.14 kWh ka current continuously kio la raha hota Hai?
Overload b Nahi hota.
Please Isa ka koi solution bataya
SUB mode pe hybrid inverters Wapda se watts lete rehty hain. Yeh sirf tb e zero ho skta hai agr aap ne batteries lgayi hon aur SBU mode kia ho.
@@AllRounder-1133 yea sirf self consumption K lia watt leta Hai Kia??
Joa Wapda Meter per 0.14kwh Likha Atta
Please describe bit
Yes actually jab real time sharing pe hota hai to yeh kuch watts kam generate krta hai ta k Grid ki taraf na jaany lag jayen reverse.
@@AllRounder-1133 oh ok....samjha a Gai.
Solis 6kw Vs Nitrox 6kw
Knsa lena chayye sir?
I like Solis more. Nitrox is superb as well.
@@AllRounder-1133 Sir, what's your final suggestion to go for? As in Karachi, I'm unable to find any solis installer while everyone installs nitrox. There is a difference in PVs of both, so what's your final suggestion,
Do you provide services in Karachi?
We don't have services in Karachi.
Solis has higher PV capacity compared to Nitrox.
It also has higher VDC range.
Its output is 6600watt compared to Nitrox 6000watts.
It also has bluetooth realtime data monitoring or inverter settings.
So all these are plus points of Solis over nitrox but again you can go for what you are able to purchase easily.
Bhai ma without battery use kr raha h smart load ks tra chale ga
Firmware update kren agr option nhi aa rha to.
Dear Admin, please share price for Inverter
205K
Jinko 585 watts k sath pv fuse kitny amps ki use hoti hy totall 10 panel pay
Agr series me hain to 16 Amp.
@@AllRounder-1133 series conaction hain
Yes 16amp fuse.
Hum ne yeh Solis 6kw Hybrid liya hai. Yeh wapda ko pass nahi ker raha. Setting ka masla hai. Any help available ?
Without battery use kr rhy hain? Please send voice note on WhatsApp. Number is in the description.
@@AllRounder-1133 with 4 tubular batteries. Yes I will Whatsapp
me ne b 3 liye the bhtt mhnt hui seeti gs pe pr ub 3ino fit chal rahe heb
Sir g yeh inverter single phase hy kia yeh net merting krta hu
Yes single phase hai and supports net metering.
I have similiar issue.
Hamara ghar ki pani wali motor Is braker mai sa "Solar" par change karna sa nahi chalti. isi lia hum na usa wapda par kia hua hai. green meter laga hua hai or battery bhi. bus changover ko hum na wapda par rakha hai na ka solar par. To is sa koi issue to nahi hoga?
Jab aap k net metering ho jaye to Pump aap ko anyway Wapda pe e chalana chahiye. Net metering k baad inverter ki output side pe sirf wo cheezain lgayi jati hain jo aap ko light off me b chalani hain otherwise sb kuch Wapda pe chaly koi issue nhi hota.
@@AllRounder-1133 bus is sa yeah hota hai ka hamain jab light jati hai to ja kar changeover ko wapda sa solar par karna parta hai.
Wo to bht kam e aisa hota ho ga k light off me aap ko Motor chalani e pary. Agr bht frequently aisa hai to aap phr usey backup pe kr skty hain.
@@AllRounder-1133 sahe lekin meri query hai ka agar changeover ko hum na wapda par rakha hai rather than on solar to issue to nahi hai koi ?
Green meter installed hai
@@ZafarIqbal-jo3wz ap without batteries use kr rhy hain ? Wapda jany py inverter off ho jata ha ?
Asalamualaikum CT of my solis hybird 6 KVA is not working i need guidence to redolve it
What issue are you facing? Please send a voice note on WhatsApp.
Sir your number plz
Sir your number plz
+923366630708 WhatsApp messages only.
Bhai ye mora ki db kahan se mile gi?
Faisalabad se e leta hn me aap local market se try kren.
@@AllRounder-1133 main ne brandeth road ki kafi shops se pucha hai nhi mila. Chalain aj phir dekhta hun
Bhai din k waqt wapda band hony par tu sb kch bnd ho jana ha phr kya faida iska.panels b wapda bnd par use ni hony
Inverters always work on 2 sources properly. It may have worked if we had more voltages, we only had 300volts in this system.
Export karne ke setting bata the...
Us k liye aap Feed in priority ko on kren.
Phr Grid Feed in Power limit me ja k. Limit ko disable kr den ya apni maximum export limit daal len.
Price of solis 6 kw invertet
Around 340K
Sir is ki warranty kase check kr sakty hain
Their support has all the details as inverter has online warranty and no physical documentation.
@@AllRounder-1133 ap se contact krna ho or solis ki installation krwani ho tu kase rabta kr sakty hain
@@MSubhan-mt3hd only in Fsd. WhatsApp Number in description.
solis vs solar max?
Solis.
Price kia hai is ki
340K
Mujhy solis installation krvani ha ap kr dy gy
Which city?
سٹی اس سسٹم کے ساتھ ملتی ہے یا الگ سے لی ،
تو کتنے کی لی ؟
مجھے یہی طریقہ کار درکار ہے مگر پہلے 5kw کے سسٹم کے ساتھ مرج کرنا ہے
CT sath aati hain un inverters k jin me zero export ho.
Sir din ka time ya bagar wapda or battery ka on hota ha rat time jab bajle bad ho ka Dora ate ha to on nahe hota per bay pass Kara parta ha lakin din time ya bajle Jane pe off hota 1 minutes bad per on ho gata ha
Sirf PV pe on ho jata hai aap ka mtlb?
Panel 6 hy to nai chaly ga bina wapda support k ager without battery hy to panel kam as kam 8 hony zrori hy
@@AneesAslam4713 ap ny batteries nahi lagai ?
@@androiddeveloperz koi battery nai 8 panel kafi hain 2000 watts k lye
@@androiddeveloperz ager nai to choti battery lga lo 70amps wali 15 se 17 tak milti hy 130amps wali 25 tak load chaly ga phr aram se
Kia ya inverter without batteries only solar pr kam kr sakta hie...
Yes. We haven't used batteries in this setup but Wapda honi zruri hai.
Can we run it only on solar panels.
This one doesn't work on just solar panels. Min. Two sources are required.
👍👍
@@AllRounder-1133 8 panel ya 10 panel hon to chal jata hy mery ghar chal rha hy chota load chal jata hy heavy load 11am k bad chalta hy pump wegera
Structure is not strong,
L3 L2 to hoty e strong hain kyun k wind pressure itna hota nhi hai. Jo last hai wo bs ek panel hai and bht zyada space hai us me. Phr kuch constraints b dekhny party hain k krna e portable hai.
What is price of solis 6 kw inverter
Around 340K
Isay ucha Inverex 360 main ara 20k ka farq bus
Features iske achy hain. Isme ip66 hai. Efficiency zyada hai us se. Advance monitoring hai@@WaqasMehmood0345
@@WaqasMehmood0345kdr مل raha ha inverex nitrox 6kw?
Get infinite it's around 210
Notrox 6kw without utility and without battery chal skta
If no kiun ni chal sakta technical reasons
Agar possible hay to please is par b video bna dain
Any contact number please
Actually brother koi b solar inverter ho. Chal to skta hai High PV voltage hon but na chalny ya chalany ki reason yeh hai k PV is not constant energy, thora b load uper neeche ho ga to inverter trip kr kaye ga.
WhatsApp messages only: +923366630708
@@AllRounder-1133 nitrox run on 20watts only
To i think 20 w ka to koi masla ni
voice quality is vary poor.
Yes the mic stopped working.
Solis ka inverter Laga ker hum to phans gaye hein. Third class service hai
What happened? Solis has really good inverters, zero complaints so far.
@@AllRounder-1133Zero service. Just go through the comments of Solis Inverter. You will see response of customers who have purchased Solis
@@xpsmango4146 sahee
Brother Apka number mil sakata
Its in description, WhatsApp messages only please.
Apka koi contact number mil sakta hai?
+923366630708 WhatsApp messages only
Contact number apka
In the description.
Janab apka contact number ?
+923366630708 WhatsApp messages only
Bhai apna Contact Number share kijye ga mjy system lagwana hai
Only in Faisalabad brother, +923366630708 WhatsApp messages only.