Solis 6KW hybrid inverter installation | Zero export | Perfect working of SUB mode without battery

Поделиться
HTML-код
  • Опубликовано: 31 май 2024
  • Whatsapp messages only: +923366630708
    In this detailed video, we demonstrate the installation of the Solis 6KW Hybrid Inverter, showcasing its zero export capabilities and perfect SUB mode operation without a battery. Learn how to add a CT (Current Transformer) to make it function as an on-grid inverter while maintaining zero export to the grid. Discover our innovative solution for running the Solis 6KW inverter without a battery, overcoming the common issue of it not turning on without one. Whether you're an installer or a solar enthusiast, this video provides essential insights and practical solutions to optimize your solar setup. Watch now and unlock the full potential of your Solis 6KW Hybrid Inverter!
  • НаукаНаука

Комментарии • 172

  • @shahidkaleem1766
    @shahidkaleem1766 2 месяца назад

    Welldone 👍
    Kammal ka structure bnaya hai.

  • @mirzashahzaib
    @mirzashahzaib 2 месяца назад

    Great!!!!

  • @SaeedSolution
    @SaeedSolution 2 месяца назад

    Nice ❤
    Good going brother ❤

  • @awaisjavaid2120
    @awaisjavaid2120 2 месяца назад

    Nice work, by the way maxpower pv7000 me bi ehsy hi 6 6 ki parallel me lag sakti hen?

    • @AllRounder-1133
      @AllRounder-1133  2 месяца назад

      Us me parallel aap uper e kr len. Neeche string laany ki zrurt nhi hoti.

  • @usmanniazi7404
    @usmanniazi7404 Месяц назад +1

    Sir iski setrings ki detail video bnayain jis m hr setting ko describe kiya gya ho

  • @xsaad.hashmi
    @xsaad.hashmi Месяц назад +1

    Bro where i should connect the (ac) air conditioner wire
    In grid or gen

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Generator and make it smart load from settings.

  • @wassaufkhalid8593
    @wassaufkhalid8593 Месяц назад

    same case ham na bhi kia ha is k sath. without battery but all load is on backup load. and PV k na hote hue bhi wapda se chalta ha. and zero export k lie app k andar allow export ki option off kar sakte

    • @imranrizvi8006
      @imranrizvi8006 8 дней назад

      اسلام و علیکم بھائی میں نے بھی اس انورٹر کو بغیر بیتری استعمال کرنا ہے پر یہ software per status off show کر رہا ہے مجھے اسکی setting بتا سکتے ہیں اور اسکی ct تو لگنی ہی grid کی phase wire پر ہے مجھے اسکی سمجھ نہیں ائی

    • @wassaufkhalid8593
      @wassaufkhalid8593 8 дней назад +1

      @@imranrizvi8006 wiring Ka Kaam to engineer na Kia tha to us Ka mujhe Nahi pata ziada .. lekin ye wapda bagher Nahi chalta .. ya to battery ya wapda laazmi ho to tab solar use Kar sakte is mein

  • @shahidkaleem1766
    @shahidkaleem1766 2 месяца назад

    Sir isi tarhn ka koi 24v hybrid inverter bta dain jo wapda se real-time shairing k doran fazool ki consumption na kry.

    • @AllRounder-1133
      @AllRounder-1133  2 месяца назад

      Batteries k sath SBU Ya phr Nitrox 3KW

    • @tractorandtubewells2997
      @tractorandtubewells2997 Месяц назад

      What's app number mil sakta hy inverter ki information chahye brother​@@AllRounder-1133

  • @j-sstories4521
    @j-sstories4521 27 дней назад

    Bhai CT kidr lagne ha kindly guide karn mane abe ct inverter sa ju phase wire niklte ha os per lagge ha CT inverter or Ac DP box kay mid ma lagye ha direction AC Dp box ki side per ha

    • @AllRounder-1133
      @AllRounder-1133  27 дней назад

      Bhai CT aap ne connect krni hoti hai us wire pe jo Meter se aa rhi ho kisi b load se pehle. Aap k main breaker k pas lgayen usey jo bijli ki wire ghr me aati hai us pe Phase pe Arrow meter ki taraf ho.

  • @qaiserlatif9519
    @qaiserlatif9519 Месяц назад

    Aoa Sir Eid Mubarak, can you please guide me regarding following :-
    1) Which Solar inverter in 6kw IP 65 is good feature wise Solis or Solax.
    2) Which Lithium battery in 100AH is good.

    • @wassaufkhalid8593
      @wassaufkhalid8593 Месяц назад +1

      Quality wise solis would be way better than solax. Solax is associated with fronus and fronus has very bad reviews

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад +1

      No experience with Solax. So can't really comment on that.

    • @saeedkhan8045
      @saeedkhan8045 Месяц назад +2

      Bro Solis is far better world wide brand It competes inverex and is much better. The only issue is limited service centers in Pakistan.
      As for as battery is considered I suggest you to buy Solar Max Lithium ion battery 105 amp with 7000 life cycle the latest technology.

  • @user-it6pe9kb2q
    @user-it6pe9kb2q Месяц назад

    sirf solar panel ki input par to nahi chaly ga ye , to is pe perfect working kia huwi ct to har ip65 inverter ky sath ata ha and khudi pv and wapda ki realtime sharing ko manage karta ha

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      One of the subscribers have used it with just PV when solar panels are 8 or more. Wapda se kuch na kuch consumption hoti hai dusry inverters k feedback k mutabiq. Is me zero thi.

  • @dawoodnawazkhan8200
    @dawoodnawazkhan8200 14 дней назад

    Assalam o Alikum. Brother mera 8 kw Solis hybrid hai with 16 Jinko 585 panels. MashaAllah buhat achi output aa rahi hai. Actually jo issue aa rha hai wo yeh hai k jb light jati hai or wapis ati hai tou ius my Thora issue aa rha. Hmary ghr k load ni chlta. Usky liye Input breaker ko down kr k up krna prta hai or us my bh kafi time k bad load on hota hai ghr ka. Installer se bat hoi. Wo khty hn k batteries must han is k liye. Jb k hybrid k suna tha k battery ki zarorat ni prti. Please guide kr den

    • @AllRounder-1133
      @AllRounder-1133  14 дней назад

      Sir WhatsApp pe msg kren aap ko voice note bhej deta hn. Actually aap ko installation change krni pary g. Number in description.

  • @TheQaiserlatif
    @TheQaiserlatif Месяц назад

    Aoa Sir, Solis 6KW invertor k sath AKcome 700W bificial panels laga sakty hain

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад +1

      Yes brother.

    • @TheQaiserlatif
      @TheQaiserlatif Месяц назад

      @@AllRounder-1133Thanks for your feedback. I am interested to install 6KW solar system at my home. Can you please provide your services. How can i contact you.

  • @BilalAhmad-iv3es
    @BilalAhmad-iv3es Месяц назад +1

    Mein ny yahi inverter lagaya hya hy with 12 PVs. Ap ny SUB mode kaisy configure kia hy? Please guide kr dein. Mjhy settings nhi mili kafi dhonda. Currently mera inverter mode SBU chal rha hy, isko mein ny SUB krna hy.
    Dosra, hmari taraf wapda voltage kafi low hoti hy 185V ~ 205V k bech. Inverter ki output 235V py set hy. Jb light chali jati hy tu inverter 230V~235V daita hy, Lekin Wapda k hoty huay inverter output 190V ~ 205V k bech ajati hy, byshk Solar generation ya battery sy he ghr ka load chal rha ho. Agr apko ye setting b maloom hy k inverter output voltage hamesha 230V~235V rahy, Wapda sy jitny marzi Volts arhy hon tu please wo b bta dein.

  • @AyaanMalik-t9g
    @AyaanMalik-t9g 27 дней назад

    Sir kia hum CHOTI batteries Laga sakhty Hy 6kw ke system ke sath... 100 amp ki 4 batteries Laga sakhty hy

    • @AllRounder-1133
      @AllRounder-1133  26 дней назад

      G lga skty hain bs settings me se charging amps kam kr den aur DC cut off voltage bht low na rakhen. Behtreen chalen g.

    • @AyaanMalik-t9g
      @AyaanMalik-t9g 26 дней назад

      @@AllRounder-1133 thank u so much

  • @mufasagreatest5431
    @mufasagreatest5431 Месяц назад

    Toh kia jab wapda load shedding se band hogi. To kya solar production band ho jae gi. Matlb ye as ongrid work kry ga without battery?
    Mene 8kw ka solis purchase kiya hai.

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      If you have more voltage interns of panels. It may work but there are chances of tripping.

    • @aftabsiddiqui7134
      @aftabsiddiqui7134 Месяц назад

      Apki CT theek kaam kr Rahi he means jitna load grid ko ja Raha hota he wo app pr show krta he?

  • @NasirMehmood-yt7nw
    @NasirMehmood-yt7nw Месяц назад

    Salam dear Kiya ap is k parameters ki videos shared Kar skate Hain complete

  • @OTTO-qy9bg
    @OTTO-qy9bg 17 часов назад

    aoa sir!
    hamne SOlis hybrid 6KW lagwaya ha , but vo wapda se light ni le raha, Dc pump on krne pe trip ho jata ha, is mn kya issue ho saqtaa ?

    • @AllRounder-1133
      @AllRounder-1133  13 часов назад

      Wasalam. Whatsapp pe video bna k bhej den, aise idea nhi ho ga aap k sawal ka.

  • @perfectasif
    @perfectasif Месяц назад

    Total cost of complete system? Inverter price?

  • @MuhammadAwais-wl6fu
    @MuhammadAwais-wl6fu 2 месяца назад

    Sir please Mera reply de g a ga.
    Meray pass Inverex verion 6k Joa K 8 pannels 585 watt K Hai Laga hova Hai.
    Day time main jub PV enough generate ho rahi Hoti Hai toa meter Sa b 0.14 kWh ka current continuously kio la raha hota Hai?
    Overload b Nahi hota.
    Please Isa ka koi solution bataya

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      SUB mode pe hybrid inverters Wapda se watts lete rehty hain. Yeh sirf tb e zero ho skta hai agr aap ne batteries lgayi hon aur SBU mode kia ho.

    • @MuhammadAwais-wl6fu
      @MuhammadAwais-wl6fu Месяц назад

      @@AllRounder-1133 yea sirf self consumption K lia watt leta Hai Kia??
      Joa Wapda Meter per 0.14kwh Likha Atta
      Please describe bit

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Yes actually jab real time sharing pe hota hai to yeh kuch watts kam generate krta hai ta k Grid ki taraf na jaany lag jayen reverse.

    • @MuhammadAwais-wl6fu
      @MuhammadAwais-wl6fu Месяц назад +1

      @@AllRounder-1133 oh ok....samjha a Gai.

  • @shahmeerahmed9992
    @shahmeerahmed9992 Месяц назад

    Solis 6kw Vs Nitrox 6kw
    Knsa lena chayye sir?

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      I like Solis more. Nitrox is superb as well.

    • @shahmeerahmed9992
      @shahmeerahmed9992 Месяц назад

      @@AllRounder-1133 Sir, what's your final suggestion to go for? As in Karachi, I'm unable to find any solis installer while everyone installs nitrox. There is a difference in PVs of both, so what's your final suggestion,
      Do you provide services in Karachi?

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      We don't have services in Karachi.
      Solis has higher PV capacity compared to Nitrox.
      It also has higher VDC range.
      Its output is 6600watt compared to Nitrox 6000watts.
      It also has bluetooth realtime data monitoring or inverter settings.
      So all these are plus points of Solis over nitrox but again you can go for what you are able to purchase easily.

  • @j-sstories4521
    @j-sstories4521 Месяц назад

    Bhai ma without battery use kr raha h smart load ks tra chale ga

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Firmware update kren agr option nhi aa rha to.

  • @saadhasan6612
    @saadhasan6612 Месяц назад

    Dear Admin, please share price for Inverter

  • @AneesAslam4713
    @AneesAslam4713 2 месяца назад

    Jinko 585 watts k sath pv fuse kitny amps ki use hoti hy totall 10 panel pay

  • @xpsmango4146
    @xpsmango4146 25 дней назад

    Hum ne yeh Solis 6kw Hybrid liya hai. Yeh wapda ko pass nahi ker raha. Setting ka masla hai. Any help available ?

    • @AllRounder-1133
      @AllRounder-1133  25 дней назад

      Without battery use kr rhy hain? Please send voice note on WhatsApp. Number is in the description.

    • @xpsmango4146
      @xpsmango4146 25 дней назад

      @@AllRounder-1133 with 4 tubular batteries. Yes I will Whatsapp

    • @mianasif357
      @mianasif357 23 дня назад

      me ne b 3 liye the bhtt mhnt hui seeti gs pe pr ub 3ino fit chal rahe heb

  • @abdulqayyum1299
    @abdulqayyum1299 8 часов назад

    Sir g yeh inverter single phase hy kia yeh net merting krta hu

    • @AllRounder-1133
      @AllRounder-1133  6 часов назад

      Yes single phase hai and supports net metering.

  • @ZafarIqbal-jo3wz
    @ZafarIqbal-jo3wz Месяц назад

    I have similiar issue.
    Hamara ghar ki pani wali motor Is braker mai sa "Solar" par change karna sa nahi chalti. isi lia hum na usa wapda par kia hua hai. green meter laga hua hai or battery bhi. bus changover ko hum na wapda par rakha hai na ka solar par. To is sa koi issue to nahi hoga?

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Jab aap k net metering ho jaye to Pump aap ko anyway Wapda pe e chalana chahiye. Net metering k baad inverter ki output side pe sirf wo cheezain lgayi jati hain jo aap ko light off me b chalani hain otherwise sb kuch Wapda pe chaly koi issue nhi hota.

    • @ZafarIqbal-jo3wz
      @ZafarIqbal-jo3wz Месяц назад

      @@AllRounder-1133 bus is sa yeah hota hai ka hamain jab light jati hai to ja kar changeover ko wapda sa solar par karna parta hai.

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Wo to bht kam e aisa hota ho ga k light off me aap ko Motor chalani e pary. Agr bht frequently aisa hai to aap phr usey backup pe kr skty hain.

    • @ZafarIqbal-jo3wz
      @ZafarIqbal-jo3wz Месяц назад

      @@AllRounder-1133 sahe lekin meri query hai ka agar changeover ko hum na wapda par rakha hai rather than on solar to issue to nahi hai koi ?
      Green meter installed hai

    • @androiddeveloperz
      @androiddeveloperz Месяц назад

      @@ZafarIqbal-jo3wz ap without batteries use kr rhy hain ? Wapda jany py inverter off ho jata ha ?

  • @aftabsiddiqui7134
    @aftabsiddiqui7134 Месяц назад

    Asalamualaikum CT of my solis hybird 6 KVA is not working i need guidence to redolve it

  • @ishaqnabi5791
    @ishaqnabi5791 Месяц назад

    Bhai ye mora ki db kahan se mile gi?

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Faisalabad se e leta hn me aap local market se try kren.

    • @ishaqnabi5791
      @ishaqnabi5791 Месяц назад

      @@AllRounder-1133 main ne brandeth road ki kafi shops se pucha hai nhi mila. Chalain aj phir dekhta hun

  • @hsnch1113
    @hsnch1113 Месяц назад

    Bhai din k waqt wapda band hony par tu sb kch bnd ho jana ha phr kya faida iska.panels b wapda bnd par use ni hony

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Inverters always work on 2 sources properly. It may have worked if we had more voltages, we only had 300volts in this system.

  • @tanveerrana6924
    @tanveerrana6924 Месяц назад

    Export karne ke setting bata the...

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Us k liye aap Feed in priority ko on kren.
      Phr Grid Feed in Power limit me ja k. Limit ko disable kr den ya apni maximum export limit daal len.

  • @user-fe6od6pk6k
    @user-fe6od6pk6k Месяц назад

    Price of solis 6 kw invertet

  • @MSubhan-mt3hd
    @MSubhan-mt3hd 23 дня назад

    Sir is ki warranty kase check kr sakty hain

    • @AllRounder-1133
      @AllRounder-1133  23 дня назад

      Their support has all the details as inverter has online warranty and no physical documentation.

    • @MSubhan-mt3hd
      @MSubhan-mt3hd 23 дня назад

      @@AllRounder-1133 ap se contact krna ho or solis ki installation krwani ho tu kase rabta kr sakty hain

    • @AllRounder-1133
      @AllRounder-1133  22 дня назад

      @@MSubhan-mt3hd only in Fsd. WhatsApp Number in description.

  • @ibrar2kt
    @ibrar2kt Месяц назад

    solis vs solar max?

  • @muhammadahmedjamil6975
    @muhammadahmedjamil6975 2 месяца назад

    Price kia hai is ki

  • @JamilAhmad-dz9wc
    @JamilAhmad-dz9wc Месяц назад

    Mujhy solis installation krvani ha ap kr dy gy

  • @kirnebatool8145
    @kirnebatool8145 Месяц назад

    سٹی اس سسٹم کے ساتھ ملتی ہے یا الگ سے لی ،
    تو کتنے کی لی ؟
    مجھے یہی طریقہ کار درکار ہے مگر پہلے 5kw کے سسٹم کے ساتھ مرج کرنا ہے

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      CT sath aati hain un inverters k jin me zero export ho.

  • @AhmadRaza-bd9lk
    @AhmadRaza-bd9lk 2 месяца назад

    Sir din ka time ya bagar wapda or battery ka on hota ha rat time jab bajle bad ho ka Dora ate ha to on nahe hota per bay pass Kara parta ha lakin din time ya bajle Jane pe off hota 1 minutes bad per on ho gata ha

    • @AllRounder-1133
      @AllRounder-1133  2 месяца назад

      Sirf PV pe on ho jata hai aap ka mtlb?

    • @AneesAslam4713
      @AneesAslam4713 Месяц назад

      Panel 6 hy to nai chaly ga bina wapda support k ager without battery hy to panel kam as kam 8 hony zrori hy

    • @androiddeveloperz
      @androiddeveloperz Месяц назад

      @@AneesAslam4713 ap ny batteries nahi lagai ?

    • @AneesAslam4713
      @AneesAslam4713 Месяц назад

      @@androiddeveloperz koi battery nai 8 panel kafi hain 2000 watts k lye

    • @AneesAslam4713
      @AneesAslam4713 Месяц назад

      @@androiddeveloperz ager nai to choti battery lga lo 70amps wali 15 se 17 tak milti hy 130amps wali 25 tak load chaly ga phr aram se

  • @junaid9944
    @junaid9944 2 месяца назад

    Kia ya inverter without batteries only solar pr kam kr sakta hie...

    • @AllRounder-1133
      @AllRounder-1133  2 месяца назад +1

      Yes. We haven't used batteries in this setup but Wapda honi zruri hai.

    • @junaid9944
      @junaid9944 2 месяца назад

      Can we run it only on solar panels.

    • @AllRounder-1133
      @AllRounder-1133  2 месяца назад

      This one doesn't work on just solar panels. Min. Two sources are required.

    • @muhammadrizwanrafique9120
      @muhammadrizwanrafique9120 2 месяца назад

      👍👍

    • @AneesAslam4713
      @AneesAslam4713 Месяц назад +1

      @@AllRounder-1133 8 panel ya 10 panel hon to chal jata hy mery ghar chal rha hy chota load chal jata hy heavy load 11am k bad chalta hy pump wegera

  • @mubasherahmed3811
    @mubasherahmed3811 Месяц назад

    Structure is not strong,

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      L3 L2 to hoty e strong hain kyun k wind pressure itna hota nhi hai. Jo last hai wo bs ek panel hai and bht zyada space hai us me. Phr kuch constraints b dekhny party hain k krna e portable hai.

  • @user-fe6od6pk6k
    @user-fe6od6pk6k Месяц назад +1

    What is price of solis 6 kw inverter

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Around 340K

    • @WaqasMehmood0345
      @WaqasMehmood0345 27 дней назад

      Isay ucha Inverex 360 main ara 20k ka farq bus

    • @wasifahmed2000
      @wasifahmed2000 22 дня назад

      Features iske achy hain. Isme ip66 hai​. Efficiency zyada hai us se. Advance monitoring hai@@WaqasMehmood0345

    • @despardis8511
      @despardis8511 18 дней назад

      ​@@WaqasMehmood0345kdr مل raha ha inverex nitrox 6kw?

    • @farhanaali5996
      @farhanaali5996 12 дней назад

      Get infinite it's around 210

  • @mwaqasquadirey
    @mwaqasquadirey 21 день назад

    Notrox 6kw without utility and without battery chal skta
    If no kiun ni chal sakta technical reasons

    • @mwaqasquadirey
      @mwaqasquadirey 21 день назад

      Agar possible hay to please is par b video bna dain

    • @mwaqasquadirey
      @mwaqasquadirey 21 день назад

      Any contact number please

    • @AllRounder-1133
      @AllRounder-1133  21 день назад

      Actually brother koi b solar inverter ho. Chal to skta hai High PV voltage hon but na chalny ya chalany ki reason yeh hai k PV is not constant energy, thora b load uper neeche ho ga to inverter trip kr kaye ga.

    • @AllRounder-1133
      @AllRounder-1133  21 день назад

      WhatsApp messages only: +923366630708

    • @mwaqasquadirey
      @mwaqasquadirey 21 день назад

      @@AllRounder-1133 nitrox run on 20watts only
      To i think 20 w ka to koi masla ni

  • @saayatoyou00
    @saayatoyou00 Месяц назад

    voice quality is vary poor.

  • @xpsmango4146
    @xpsmango4146 24 дня назад

    Solis ka inverter Laga ker hum to phans gaye hein. Third class service hai

    • @AllRounder-1133
      @AllRounder-1133  24 дня назад

      What happened? Solis has really good inverters, zero complaints so far.

    • @xpsmango4146
      @xpsmango4146 20 дней назад

      ​@@AllRounder-1133Zero service. Just go through the comments of Solis Inverter. You will see response of customers who have purchased Solis

    • @AllRounder-1133
      @AllRounder-1133  20 дней назад

      @@xpsmango4146 sahee

  • @jahanzebbutt4366
    @jahanzebbutt4366 Месяц назад

    Brother Apka number mil sakata

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Its in description, WhatsApp messages only please.

  • @abdullahshahid6216
    @abdullahshahid6216 Месяц назад

    Apka koi contact number mil sakta hai?

  • @shehrozahmad4476
    @shehrozahmad4476 19 дней назад

    Contact number apka

  • @user-ki5it7gr1u
    @user-ki5it7gr1u Месяц назад

    Janab apka contact number ?

  • @aneebmehbooob2888
    @aneebmehbooob2888 Месяц назад

    Bhai apna Contact Number share kijye ga mjy system lagwana hai

    • @AllRounder-1133
      @AllRounder-1133  Месяц назад

      Only in Faisalabad brother, +923366630708 WhatsApp messages only.