Great video, thanks for sharing! In a scenario where the inverter is located 140 meters from the main house and meter, are there alternative communication methods besides running a physical CT cable? Also, if a backup generator is part of the system, does the inverter necessarily need to be near the main meter for proper operation? How does the system ensure export shut down during a power outage to comply with safety regulations?
Can consider to use smart meter for measurement and extend the meter communication cable instead of extending the CT cable. Backup generator can be connected on grid side with ATS or directly on gen port of the inverter. Not necessarily must be close to the main meter. Export limiation is achieved by the smart CT/Meter measurement on the grid conncection point, inverter will automatically adjust the PV generation and battery charge/discharge power to ensure system export limit is followed.
Informative to help us installers. Look forward to your paralleling video - it is becomming all too common in our installs, allows to increase the number of MPPTs in a system. What is the model of the Easton that you showed?
I am facing an issue with the SBU The inverter prioritizes battery use (SBU mode) and switches to battery when the grid goes down. This behavior is normal except in a specific situation: When the battery voltage reaches 44.5V and the grid is still available, the inverter switches to grid power while also charging the battery. If the grid then goes down while the battery voltage is between 44.5V and 50V (e.g., at 50V), the inverter doesn't automatically switch back to battery, resulting in a blackout.
Please check what values you set on the overdischarge voltage/focecharge voltage. When voltage is lower than overdischarge voltage setting, hybrid inverter will stop using battery power. When voltage is lower than forceharge voltage, it will trigger the forcecharge logic and may take power from grid. And please contact our local service team who will help you troubleshoot in details
7:59 Can you please share with me the link to the parallel inverter installation video the one you are talking about? I have two S6-EH1P8K-L-PRO inverters for commissioning. @Solis7119
Dear Customer, yes. In Ireland, Solis offers the S6-EH3P(12-20)K-H model. For more details, please see: www.solisinverters.com/ie/energy_storage_inverters18/S6-EH3P(12-20)K-H_ie.html Also, please kindly feel free to reach out to our Europe team for more product information: 📞 +34 914 430 810 📧 europesales@solisinverters.com
HI Have issue in morning inverter charge the battery from pv but did not shift pv energy to backup . When we disconnect or shift inverter to off grid then pv through energy to backup. Any solution that can work automated
I am an installer/technician (whichever applies to you) and would like to set up an account to monitor multiple solar systems for my clients. Could you please provide me with the following information: 1. Steps involved in creating a SolisCloud organization account. 2. Any specific requirements for installers/technicians registering for an organization account. 3. Resources or guides available to help with the setup process.
Just need to select a 220V grid code. When with grid connected, voltage is depending on utility, inverter can adapt to a wide range of voltage without problem. Only in off grid operation, the voltage output on the backup port is determined by the inverter, the backup voltage is settable in the Solis APP.
Pls how do I reset/recover the installer password as my installer is no more in my town and can't get access. Also the inverter is showing faultshutdown. Fault is.. no. Grid detected. However grid power is connected but no CT as it is lost in transit.
You can contact our local service team for helping you update your inverters remotely. You just need to make sure the inverter is online on Soliscloud.
You can use it as a second critical load backup port, for example, when in off grid condition, both GEN and backup port can be supplied, when battery SOC reached a lower level that you set, it can cut off GEN port automically and focusing on supplying power to the backup port load. In this way ,you can prioritize you loads.
What could be the reason why after logging the data logger, then going onto the router connection, my home wifi doesn't appear in the selection list though is a 2.4 ghz not 5G... please guide... Thanks!
Great video, thanks for sharing! In a scenario where the inverter is located 140 meters from the main house and meter, are there alternative communication methods besides running a physical CT cable? Also, if a backup generator is part of the system, does the inverter necessarily need to be near the main meter for proper operation? How does the system ensure export shut down during a power outage to comply with safety regulations?
Can consider to use smart meter for measurement and extend the meter communication cable instead of extending the CT cable.
Backup generator can be connected on grid side with ATS or directly on gen port of the inverter. Not necessarily must be close to the main meter.
Export limiation is achieved by the smart CT/Meter measurement on the grid conncection point, inverter will automatically adjust the PV generation and battery charge/discharge power to ensure system export limit is followed.
Do you have a parallel connection video?
Informative to help us installers. Look forward to your paralleling video - it is becomming all too common in our installs, allows to increase the number of MPPTs in a system. What is the model of the Easton that you showed?
Solis S6 Pro 6KW Hybrid inverter works without batteries?
Workable...
Even without batteries, it can be connected to the grid normally
Will the 4MPPT three phase version be coming to Australia? If so, do you know when it will be available?
You can try this S6-EH1P8K-L-PLUS-AU, which has 4MPPT.
The pair of dc input, what is the max voltage in each input?
how to set up the inverter in injection 0 ????
Thanks for the video !
Dear customer, Solis supports setting zero export through SolisCloud or APP.
What if Solis would have LCD accessories monitoring.
I am facing an issue with the SBU
The inverter prioritizes battery use (SBU mode) and switches to battery when the grid goes down.
This behavior is normal except in a specific situation:
When the battery voltage reaches 44.5V and the grid is still available, the inverter switches to grid power while also charging the battery.
If the grid then goes down while the battery voltage is between 44.5V and 50V (e.g., at 50V), the inverter doesn't automatically switch back to battery, resulting in a blackout.
Please check what values you set on the overdischarge voltage/focecharge voltage. When voltage is lower than overdischarge voltage setting, hybrid inverter will stop using battery power. When voltage is lower than forceharge voltage, it will trigger the forcecharge logic and may take power from grid. And please contact our local service team who will help you troubleshoot in details
@solis7119 please creat android app for Google TV too.
Please make a video about pure off-grid setup.
Does it mean the two mppt are 600v each or it's 600v combined (300 each)?
Dear customer, 600V each.
@solis7119 and does each MPPT handle 6kW of solar array
Please confirm the start up voltage for this inverter. Hopefully it's not 300 to 400 volts. That would not be fine.
90Vdc
7:59 Can you please share with me the link to the parallel inverter installation video the one you are talking about? I have two S6-EH1P8K-L-PRO inverters for commissioning. @Solis7119
ruclips.net/video/b7zho8N9rNA/видео.html
Hope it helps.
Can this be set up that a generator runs the house AND charges the battery? Who sells this model in Ireland?
Dear Customer, yes. In Ireland, Solis offers the S6-EH3P(12-20)K-H model. For more details, please see: www.solisinverters.com/ie/energy_storage_inverters18/S6-EH3P(12-20)K-H_ie.html
Also, please kindly feel free to reach out to our Europe team for more product information: 📞 +34 914 430 810 📧 europesales@solisinverters.com
Hi dear can i connect solis 8kw hybrid inverter to 2 FLA felicity solar batteries. how can i know ?
After connecting two Felicity batteries in parallel, connect them to an 8kw hybrid.☀
I can't log in to solis app It's showing bad gateway error always
Please contact our local service team who will help you troubleshoot in details
HI
Have issue in morning inverter charge the battery from pv but did not shift pv energy to backup .
When we disconnect or shift inverter to off grid then pv through energy to backup.
Any solution that can work automated
Please contact Solis local service team☀
I am an installer/technician (whichever applies to you) and would like to set up an account to monitor multiple solar systems for my clients.
Could you please provide me with the following information:
1. Steps involved in creating a SolisCloud organization account.
2. Any specific requirements for installers/technicians registering for an organization account.
3. Resources or guides available to help with the setup process.
Ports seem very similar to Deye/Sunsynk - no bad thing!
Can i know what is the grid code settings for philippines?
Just need to select 'Philippines' option in grid code selection.
How to select 220AC output ...now pre selected 230VAC which is not suitable for some appliance in my place.? Please explane thanks.
Just need to select a 220V grid code. When with grid connected, voltage is depending on utility, inverter can adapt to a wide range of voltage without problem. Only in off grid operation, the voltage output on the backup port is determined by the inverter, the backup voltage is settable in the Solis APP.
Thanks ,,
Can grid and generator both can supply electricity simultaneously
Yes
How do I set this type of inverter not to export surplus to the grid?
Use the "Feed in power limit" function on the APP
How to reset owner password as i forget that/ not able to login
Pls how do I reset/recover the installer password as my installer is no more in my town and can't get access. Also the inverter is showing faultshutdown. Fault is.. no. Grid detected. However grid power is connected but no CT as it is lost in transit.
The same concern here, need to reset the installer account.
Long press the power icon on the LED ribbon for 5s, then you can reset the bluetooth password.
Is this work without battery
yes
Yes, you can set "no battery" mode in battery model selection, and use it as a normal PV grid tied inverter
how to update firmwire online?
You can contact our local service team for helping you update your inverters remotely. You just need to make sure the inverter is online on Soliscloud.
Could you let us know what we can use the generator port as the second output load port?
Never
You can use it as a second critical load backup port, for example, when in off grid condition, both GEN and backup port can be supplied, when battery SOC reached a lower level that you set, it can cut off GEN port automically and focusing on supplying power to the backup port load. In this way ,you can prioritize you loads.
Please Guide installer account reset sittings
Hello! I have the same concern here. Thanks in advance for your response.
Long press the power icon on the LED ribbon for 5s, then you can reset the bluetooth password.
@@solis7119 thank you!
Hey this guy is nice, but what's up with his hair?
What could be the reason why after logging the data logger, then going onto the router connection, my home wifi doesn't appear in the selection list though is a 2.4 ghz not 5G... please guide... Thanks!