DANGEROUS HOUSE WIRING - Electrician Life

Поделиться
HTML-код
  • Опубликовано: 14 сен 2021
  • DANGEROUS HOUSE WIRING - Electrician Life.
    Join Cory, Reuben & Lee as they carry on digging into the house that is riddled with VIR cabling, how will they get around the situation? Electrician life is not always easy!
    Todays Video Sponsor: Tradify
    Get 50% Off Tradify for your first 3 months using our discount code "ARTISAN" bit.ly/3gzL8GI
    🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
    ➤ / @artisanelectrics
    🧰🛠️ Tool Of The Day 👇
    Unilite SLR1000: amzn.to/3zdgx8y
    🏷️😱 Big Boots - get 5% off our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    -----Electricians Business Course-----
    📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
    ➤ course.electriciansbusinessco...
    🔔 Subscribe to TOOLS4SPARKS RUclips Channel 👇
    I Also Have A Dedicated RUclips Channel About Tools:
    ➤ / tools4sparks
    -----TESLA REFERRAL CODE-----
    🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
    ➤ ts.la/andrew24855
    -----MY ENERGY PROVIDER-----
    🐙 Get £50 credit when you switch to Octopus Energy 👇
    ➤ share.octopus.energy/zappy-sh...
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
    #sparkylife #electricianlife #artisanelectrics
  • НаукаНаука

Комментарии • 106

  • @artisanelectrics
    @artisanelectrics  2 года назад +3

    Get 50% Off Tradify for your first 3 months using our discount code "ARTISAN" bit.ly/3gzL8GI

  • @richardcornelius220
    @richardcornelius220 2 года назад +19

    Great to see Lee settling in nicely with youtube following him round. Great job guys.

  • @jontownsend8090
    @jontownsend8090 2 года назад +13

    Great job done under difficult circumstances. Thumbs up to the DNO for finally providing a safe earthing arrangement.

  • @GIOGS
    @GIOGS 2 года назад +6

    Great to see Lee far more chilled with the guys and camera now!

  • @boat303
    @boat303 2 года назад +3

    Jordan nails it with his hiring every time, 6 months to a year and Reuben will be smashing Bundy and CJRs apprentices. And he’s more charismatic from day 1

  • @J4MB0
    @J4MB0 2 года назад +16

    some of the best electrical content on youtube. interesting content. great editing.

  • @reg2590
    @reg2590 2 года назад

    The first part of this clip reminded me of a work colleague who unfortunately knocked himself unconscious due to working in a false ceiling without a helmet. It was a telephone exchange and the upper floor was solid concrete !! You produce very informative videos - thanks.

  • @andrewdonagher6497
    @andrewdonagher6497 2 года назад +12

    Full rewire lads or walk away bloody nightmare cheers for the video

  • @philipsmith0752
    @philipsmith0752 2 года назад +1

    good to see the team working to gether trying to to resolve all the isuse , Cory , Reuben and Now Lee jelling together . keep up the good work guys

  • @krafty864
    @krafty864 2 года назад +6

    Genuinely enjoying every video. Keep up the good work.

  • @awhitaker2889
    @awhitaker2889 2 года назад

    Top job chaps..enjoying some honest opinions under some challenging situations 👏👌

  • @aaznomi
    @aaznomi 2 года назад

    Really good content, enjoyed that.

  • @ianlove3
    @ianlove3 2 года назад

    Well done the 3 of you.

  • @jsptravels
    @jsptravels 2 года назад +4

    Polystyrene tiles were never actually outlawed, as they’re only (really) dangerous when painted with gloss paint by well meaning but ultimately incorrect DIYers.
    People just don’t use them anymore.

  • @giuseppe9145
    @giuseppe9145 10 месяцев назад

    Great job... watching from Italy..

  • @g.williamswilliams8442
    @g.williamswilliams8442 2 года назад

    Always good viewing.
    Cheers

  • @stevejudd7777
    @stevejudd7777 2 года назад +1

    TBH good on you for sticking with it - in my day I would have walked away. I couldnt bring myself to leave VIR live and this was in the 80s. Saying that, Circuit protection is better now also.

  • @BlackFoxDayZ
    @BlackFoxDayZ 2 года назад

    Nice content as always! :)

  • @neilstokescvwshrewsbury7939
    @neilstokescvwshrewsbury7939 2 года назад

    Makes my house look good !

  • @johnspallen3132
    @johnspallen3132 2 года назад

    Brilliant lad spark now for 35 years 👏 still learn from u chaps stay safe 👍

  • @arronbloomberg605
    @arronbloomberg605 2 года назад

    Great video

  • @berniewilson4438
    @berniewilson4438 2 года назад

    Good tip for all sparks, if u can’t get to a certain area video with flash on to see what’s going on

  • @ZayroFlex
    @ZayroFlex 2 года назад

    Lee can I have a link to your headlights on the van they are sickk

  • @Biglen1165
    @Biglen1165 2 года назад

    Hey ask Jordan what the speed limit is on the M11, and did the Aston Martin leave him standing 😁 great channel by the way👍👍

  • @timg6850
    @timg6850 2 года назад

    Have you thought about surface mounting a new cable to bypass the old VIR cable?

  • @thomasmalyon1249
    @thomasmalyon1249 2 года назад

    Would it be worth installing an AFDD on the downstairs lighting circuit, as a precaution in case the VIR further degrades?

  • @markdenny7324
    @markdenny7324 2 года назад +21

    Is it £80+vat per hour per man? If so, not a surprise Jordan isn’t about anymore I guess he’s in the Caribbean on his yacht 🤔

  • @lsSmithy21
    @lsSmithy21 2 года назад

    That switch board location is nightmare fuel haha

  • @TheChipmunk2008
    @TheChipmunk2008 2 года назад

    With quinetic you need a different receiver for dimming. The switches are the same (at least the newer retractive ones)

  • @aaznomi
    @aaznomi 2 года назад +3

    Have you ever seen VIR cable in Cappin and casing ,which is a wooden trunking with two channels for the live and neutral?

    • @wizard3z868
      @wizard3z868 2 года назад +2

      Sounds a lot like in the states the knob and tube lines I'm in the northeast and run into it constantly including my rentals for the past 30 yrs lol

    • @tobykuhnert1
      @tobykuhnert1 2 года назад +2

      I have but wasn't in use, just been left in the floor.

    • @Waynesworldofgaming
      @Waynesworldofgaming 2 года назад +2

      I did on a job a few years back, they even trunked all the cables in the loft with wooden trucking. It was exquisite

    • @haldo691
      @haldo691 2 года назад +1

      Worked in a house in Northampton that had original dc wiring under the floors bare wires on porcelain insulators stretched between the joists

  • @ASour1170
    @ASour1170 2 года назад +1

    As a spark myself I have to say - Cory's Aussie H20 Just Add Water impression made the video.

  • @RichardArblaster
    @RichardArblaster 2 года назад +1

    19:25 Looks like we've found Lee's hidden talent as a director 😎

  • @samuel2j213
    @samuel2j213 2 года назад

    What is the black stuff you use as grommet strip , I know Cory has mentioned it at some point but can’t find it

  • @TeamSimpsonRacing
    @TeamSimpsonRacing 2 года назад +7

    I personally wouldn't have touched that house with a barge pole. EICR first and the outcome would have been a rewire. If the customer doesn't want a rewire, then walk away. I'd rather sleep well at night knowing i hadn't put my name to that.

  • @sam04019491
    @sam04019491 2 года назад +1

    I pissed myself when you explained Jordan’s hidden talent.

  • @9plusinstalaciones
    @9plusinstalaciones 2 года назад

    We did a rewire in a bungalow in Staffordshire 30 years ago and the company had chocoblocked VIR and Twin and called it a rewire. How do people sleep?

  • @steverobinson8170
    @steverobinson8170 2 года назад

    My main concern wouldnt be the vir cable it would be the polystyrene ceiling tiles they are highly inflammable, drip scalding hot and release toxic gas takes on little spark

  • @callummckay8838
    @callummckay8838 2 года назад

    Does anyone know what the work trousers Cory wears? Cannot find them anywhere, cheers in advance

  • @davidcross30
    @davidcross30 2 года назад

    Oi oi. This little 2 core cable went to market.

  • @craigbuist4636
    @craigbuist4636 2 года назад +4

    From the original board change, how were you able to issue an electrical installation certificate if the property was not safe with non compliant ZE readings and failing insulation resistance readings?

    • @gregwalker1386
      @gregwalker1386 2 года назад

      I agree. An install cert doesn't have codes attached and to install a new board everything has to be satisfactory it's not an EICR. Once your in it if the customer won't pay it's down to you at least that's what Ray Waterhouse told me on my first assessment in 2006 with the NIC. You touched it last, you are liable. This should have been agreed before or not started. Good luck with the customer signing the danger report if not, it's on you. No one should touch jobs like and leave them unsafe. This is a typical scenario where I would say to the customer you need to do x y & z and another contractor says no we can just do y and they win the job and you look like your ripping them off.

    • @paul79donegan4255
      @paul79donegan4255 2 года назад

      Indeed please explain how you changed a CU and only found out it was vr after.....don't you guys so eicr before a CU change ?

  • @RobboSystems
    @RobboSystems 2 года назад

    info on reciever and smart switch please??

  • @BrianCoville
    @BrianCoville 2 года назад

    In this guy situation I would use indoor conduit it can be done nicely without tearing the house apart.

  • @Waynesworldofgaming
    @Waynesworldofgaming 2 года назад

    Tbf you’ve got tncs, a full rcbo board, as long as bonding etc is up to scratch and the fittings aren’t metal it’s not really that unsafe. You’ve done the best you can under the circumstances you’ve been dealt

  • @MrFixItDK
    @MrFixItDK 2 года назад +3

    Have a drink every time anyone says "literally"

  • @jasonhowe1697
    @jasonhowe1697 2 года назад

    that is the problem with reno's you basically have to rewire the whole place doing a halve arsed job is still a half arsed job at the end of the day, fixing patch-ins is fine though if you aren't actually fixing the faults properly then it is a bad policy of repair to a point and not fix it...

  • @petertallowin6406
    @petertallowin6406 2 года назад

    Button location is the job of an apprentice. A true master knows not only where but what type. Go forth and point the finger of justice....

  • @mrm.k7655
    @mrm.k7655 2 года назад

    I have seen you in stevenage this morning. Do you live in here ?

  • @RichardArblaster
    @RichardArblaster 2 года назад

    11:05 😆😆😆

  • @mathman0101
    @mathman0101 2 года назад

    Teeny tiny earth rods we have to pound 8ft rods in US 6ft apart minimum.

  • @the_real_hislordship
    @the_real_hislordship 2 года назад

    Next Cory can try a South African accent.
    But which one? There are so many!

  • @SPARKY400T
    @SPARKY400T 2 года назад +3

    Rewire !

  • @chasestone2124
    @chasestone2124 2 года назад

    I'm curious how old you guys are ?

  • @OLIFAB
    @OLIFAB 2 года назад

    Hey 👋🏼

  • @zjzozn
    @zjzozn 2 года назад

    VIR is the future

  • @thinhead123
    @thinhead123 2 года назад

    Where has Ruben gone?

  • @4oh4200
    @4oh4200 2 года назад

    Upvoted for Nando's alone.

  • @RichardArblaster
    @RichardArblaster 2 года назад

    What a nightmare

  • @montystelevision3238
    @montystelevision3238 2 года назад +1

    Why don’t they just have a full rewire and it sorts it all out

  • @alunroberts1439
    @alunroberts1439 2 года назад

    Will the little guy fit in the gap 🤣

  • @judebrown4103
    @judebrown4103 2 года назад

    Tell you what Cory, your Spanish is more convincing than your Aussie! How is that even a thing? 😂 🤣 😂

  • @nDoornn
    @nDoornn 2 года назад

    What is VIR ?

    • @Jay369
      @Jay369 2 года назад +1

      Vulcanised Indian Rubber (cable)

    • @the_real_hislordship
      @the_real_hislordship 2 года назад +1

      LOL RUclips wants to translate your comment to English.
      What is FOR? It says.
      Probably thinks its in Afrikaans.

    • @zjzozn
      @zjzozn 2 года назад

      If only they used UK rubber in old cable. Buy cheap….. buy twice 😂

  • @gregf9160
    @gregf9160 2 года назад

    Fuck sake. Croydon. Literally _anything_ could happen 🤬
    Lee's Gigantor right-tatted arm looks dead good, though.

  • @jackhuntington8679
    @jackhuntington8679 2 года назад

    My mate does the exact same with nipples😂😂

  • @marktubeie07
    @marktubeie07 2 года назад +1

    Sorry Cory, doesn't sound Aussie to me bud _(Aussie here!)_ 14:50 😂

    • @tobysherring1369
      @tobysherring1369 2 года назад

      More like New Zealand. Not very much like New Zealand but more like New Zealand.

  • @geoffbromley6875
    @geoffbromley6875 2 года назад +9

    Please, Please stop the background music while people are talking

  • @danieladams7919
    @danieladams7919 2 года назад

    The key is off

  • @scott1506
    @scott1506 2 года назад

    if its no broke dont fix it lol ;)

  • @davidranieri924
    @davidranieri924 2 года назад

    Hey Cory that’s a nz accent not Australian ..

  • @DANNYBIOSHOW
    @DANNYBIOSHOW 2 года назад

    Cleo no

  • @D4nB0161
    @D4nB0161 2 года назад

    Why can’t a re wire be done? Am I missing something 😂

    • @steverobinson8170
      @steverobinson8170 2 года назад

      Sounds like its an old person who may have limited funds or may not cope with having the house turned upside down , look at the wardrobes hardboard dors courtsy lights all 1960's style , same with decor , the polystyrene ceiling tiles are 1960's

    • @paulf2529
      @paulf2529 2 года назад +1

      You would probably be arguing against someone saying its been working like that for the last 40 years so I'm not going to turn the house upside down now!

    • @mattpolton3802
      @mattpolton3802 2 года назад

      @@paulf2529 i say try to find a code a owhat it call when you have to fix the probme if it realy look too unsafe

    • @artisanelectrics
      @artisanelectrics  2 года назад

      The elderly customer cannot bear the hassle of moving out and having his house ripped to pieces to rewire it.

    • @steverobinson8170
      @steverobinson8170 2 года назад

      @@nickhickson8738 Probably is my daughters bought one recently similar to that full of VIR cable everything works , still amazingly getting good readings on insulation . Will be getting rewired in the future

  • @ssttraining962
    @ssttraining962 2 года назад

    "Well old"........

  • @ninjainabowlerhat
    @ninjainabowlerhat 2 года назад

    That house needs gutting.

  • @hishamw6755
    @hishamw6755 2 года назад

    Unfortunately Cory you can’t do an Aussie accent.

  • @laurencefarrugia431
    @laurencefarrugia431 2 года назад

    House bashers

  • @paul79donegan4255
    @paul79donegan4255 2 года назад

    If that house burns to the ground you lads will be in trouble .... I wouldn't of touched this as you could disturb that rubber and make it worse. Why wasn't a eicr done before you changed the CU. For a well known RUclips electrical business this looks like amateur hour.

    • @christurner6430
      @christurner6430 Год назад

      Hopefully the resident signed a statement to agree that he was aware of the potential danger, etc.

  • @healeydave
    @healeydave 2 года назад

    I took my meter readings today and noticed my meter intermittently speeding up and slowing back down despite knowing there is virtually nothing on in the house. I tried isolating various circuits and found the circuit labelled "Outside Lights" to be causing it despite there being no outside lights on!
    Any ideas what would cause that?