Refrigeration: Paragon defrost clock basic overview.

Поделиться
HTML-код
  • Опубликовано: 30 сен 2024
  • going over basic paragon mechanical defrost clock for a walk in freezer. thanks for watching

Комментарии • 6

  • @anthonyzarcone8696
    @anthonyzarcone8696 2 месяца назад

    Can i use this for my well pump

  • @EverythingHVACR
    @EverythingHVACR Год назад +1

    Nice job Bro! Keep that content coming

  • @shine-cg9uf
    @shine-cg9uf Год назад

    💪🇺🇸👍❄️ how r u testing the circuit with no voltage to clock ? Terminals 1 - N power in should have voltage reading. Jumper bar from 1 - 2 terminal so u dont need another wire to #2 terminal. Defrost contacts NO 1 - 3. Probes on 1- 3 r defrost contacts - ovolts when in defrost mode if u put probes on 3 - N during defrost u would have voltage reading(load). Cooling contacts NC Refrigeration mode probes on contacts 2 - 4 ovolts when cooling. If probes on 4 - N voltage reading(load) during cooling.

    • @hvacworx7414
      @hvacworx7414 4 месяца назад

      Hey mate I have a question, when testing this clock on a unit are we testing continuity or voltage? I'm assuming if the units on were testing voltage correct?

  • @johncole8863
    @johncole8863 Год назад

    Hell yeah bro.

  • @ShibaTactics
    @ShibaTactics Год назад

    Lets go