Aplus Water LLC
Aplus Water LLC
  • Видео 43
  • Просмотров 767 622
How to Access the Drain Line Flow Control (DLFC) on a Fleck 5600 Control Valve
In this video, we show you how to access the drain assembly on your Fleck 5600 style control valve. If you bought your DuraWater system from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We also try to respond to any relevant RUclips comments in a timely manner. We love our customers!
Просмотров: 1 991

Видео

How to Access the Injectors on Fleck 5600 Control Valve
Просмотров 3,4 тыс.Год назад
In this video, we show you how to access the injectors on your Fleck 5600 style control valve. It is important to clean these components out once or twice a year depending on the amount of iron you have in the water. If you bought your DuraWater system from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmai...
How to Remove the Fleck 5600 SXT Circuit Board
Просмотров 453Год назад
This is how you remove the circuit board from a Fleck 5600 SXT.
How to Install the Fleck 5600 SXT Water Softener
Просмотров 36 тыс.2 года назад
In this video, we show you how to install your brand new Fleck 5600 SXT water softener. If you bought your DuraWater water softener from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We also try to respond to any relevant RUclips comments in a timel...
How to Rebuild the Fleck 5600 Control Valve
Просмотров 12 тыс.2 года назад
In this video, we show you how to rebuild your Fleck 5600 control valve. This rebuild consists of replacing the main piston, seals, and spacers. This process is the same for all 5600 control valves (digital and mechanical softeners, air injection systems, and filter only systems). Depressurization video link: ruclips.net/video/hCWQYWSjt50/видео.html (Please note this is for an SXT control valve...
Fleck 5600 SXT Air Injection Programming Video
Просмотров 10 тыс.2 года назад
In this video, we show you how to program your 5600 SXT Air Injection control valve. If you bought your DuraWater air injection Iron Eater from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We love our customers! We also try to respond to any releva...
Fleck 5600 SXT Water Softener Programming Video
Просмотров 35 тыс.2 года назад
In this video, we show you how to program your 5600 SXT Water Softener control valve. If you bought your DuraWater water softener from us here at Aplus Water and you have any questions about your system, either give us a call at 877-477-5452 or email us at apluswater@hotmail.com . We are available weekdays from 9am to 4pm CST. We love our customers! We also try to respond to any relevant RUclip...
DuraWater, By Aplus Water LLC
Просмотров 2522 года назад
Hi! We're Aplus Water. With over 50 combined years of experience in the water treatment industry, our customer service and support is second-to-none. Our DuraWater whole house water softeners are available in many different sizes and styles to fit your exact needs by utilizing a variety of control valves, including our bestseller the Fleck 5600SXT, as well as different media options. Our chemic...
DuraWater On-Demand Metered Water Softener
Просмотров 7772 года назад
The Durawater whole house on demand metered Water Softener, by Aplus Water LLC. Here at Aplus Water, we pride ourselves in customer service. We promise to be just as helpful before the sale as we will be after the sale so, please reach out to us with any questions. We love to help our customers! Call us toll-free Monday through Friday 9am-4pm CST at 877-477-5452 or reach out through email at ap...
How to Depressurize a Fleck 5600 SXT Control Valve
Просмотров 18 тыс.3 года назад
In this video we show you how to safely disconnect your softener from your plumbing. Please remember, while reconnecting your plumbing, do NOT overtighten the screws, as this can cause damage. If you still have any remaining questions, please don’t hesitate to reach out to us! You can call us toll free Monday through Friday from 9am to 4pm CST at 877-477-5452. You can also email us at apluswate...
Fleck 5600SXT Metered Softener Installation Video Specials
Просмотров 48 тыс.5 лет назад
Fleck 5600SXT Metered Softener Installation Video Specials
*New* Special 5600SXT Metered Softener Installation Video
Просмотров 3,1 тыс.5 лет назад
*New* Special 5600SXT Metered Softener Installation Video
Upflow Calcite Filter Installation Video
Просмотров 1,3 тыс.6 лет назад
Upflow Calcite Filter Installation Video
Upflow Calcite Filter Installation Video
Просмотров 2,6 тыс.6 лет назад
Upflow Calcite Filter Installation Video
Upflow Carbon Filter Installation Video
Просмотров 3,8 тыс.6 лет назад
Upflow Carbon Filter Installation Video
Upflow Carbon Filter Installation Video
Просмотров 3,1 тыс.6 лет назад
Upflow Carbon Filter Installation Video
Fleck 5600 SXT Softener Installation Video BB
Просмотров 41 тыс.6 лет назад
Fleck 5600 SXT Softener Installation Video BB
Fleck 5600 SXT Softener Installation Video BB
Просмотров 15 тыс.6 лет назад
Fleck 5600 SXT Softener Installation Video BB
5600 SXT Air Injection Filter Installation Video
Просмотров 35 тыс.6 лет назад
5600 SXT Air Injection Filter Installation Video
Fleck 9100 SXT Installation Video
Просмотров 3,7 тыс.6 лет назад
Fleck 9100 SXT Installation Video
DuraWater Water Softener Installation PL
Просмотров 1,1 тыс.6 лет назад
DuraWater Water Softener Installation PL
DuraWater Installation Water Softener SS
Просмотров 2 тыс.6 лет назад
DuraWater Installation Water Softener SS
DuraWater Softeners - Free Shipping - Whole House Filter
Просмотров 2066 лет назад
DuraWater Softeners - Free Shipping - Whole House Filter
DuraWater Line Water Softeners
Просмотров 2647 лет назад
DuraWater Line Water Softeners
Duraline Well Water Softener
Просмотров 4077 лет назад
Duraline Well Water Softener
Air Injection Iron Eater Video
Просмотров 2,9 тыс.7 лет назад
Air Injection Iron Eater Video
Iron Blaster
Просмотров 1,6 тыс.7 лет назад
Iron Blaster
Air Injection Iron Eater
Просмотров 21 тыс.7 лет назад
Air Injection Iron Eater
DuraWater City Softener
Просмотров 1317 лет назад
DuraWater City Softener
DuraWater Line Water Softeners
Просмотров 3127 лет назад
DuraWater Line Water Softeners

Комментарии

  • @allenpartyof6
    @allenpartyof6 10 часов назад

    My Iron test reads 0.03 mg/l so do i add 15 to the H parameter (.03x5) or is 0.03 not even considered a 1. TIA

  • @eddiecedillos8417
    @eddiecedillos8417 18 дней назад

    Thank you very much. Amazing video

  • @dnycrane
    @dnycrane Месяц назад

    What setting can i adjust that has the most effect on softness, I want the water softer than the "normal" settings for a 48K capacity system.

  • @taylorflowers4598
    @taylorflowers4598 Месяц назад

    I have a 5600sxt. Flow rate was 0.0 per diagnostic check, so I just cleaned out the control valve assembly and made sure there were no built-up iron deposits remaining. I put it back together and, still, flow rate is 0.0. When I turn a faucet on, the flow indicator (water droplet icon) does not show up, and the "gallons remaining" number does not change. I can successfully run a regeneration cycle and everything works (brine draw, fill, etc., with a good float assembly). What is my next step? I think the control valve assembly is in good shape.

  • @stierbyku4922
    @stierbyku4922 Месяц назад

    Good day, I have a problem with my Fleck 5600sxt, it does not count water consumption and therefore cleaning does not start. What could it be? Have you encountered such a problem? I would be grateful for any information. Best regards, Marek

  • @Nena800
    @Nena800 Месяц назад

    DIYer here...Thank you for these videos!!!

  • @holdentasillo588
    @holdentasillo588 Месяц назад

    Will this Fleck 5600 SXT Air Injection Iron Eater Filter work for removing colloidal iron?

  • @gauravagru1
    @gauravagru1 2 месяца назад

    Do you recommend adding lubricants to seals and spacers ?

  • @balaspbponnusamy8592
    @balaspbponnusamy8592 2 месяца назад

    Excellent video 👍👍👍

  • @vanessarizio8414
    @vanessarizio8414 2 месяца назад

    Our instructions say to connect the incoming water to the DOWNFLOW inlet.

  • @CD318
    @CD318 3 месяца назад

    Good job

  • @pefferie
    @pefferie 3 месяца назад

    Wgere can I buy these 1" supply hoses?

  • @latourbrian
    @latourbrian 3 месяца назад

    Thanks for posting these videos, it taught me a lot. But... I followed all the steps in both videos and no luck. When i had the drain flow button out, I did get draw. I changed the brine valve for like $15, still no luck. All the parts in the backwash injector assembly were very clean even when i first opened it up. So I ended up buying the main piston assembly with seals and spacers for $70. I honestly didn't think it would work. It did. I have brine draw again. So if you try all the tips and still get water flowing out to the salt tank during BD, as a last resort I'd suggest a new main valve. BTW, my main piston a green top and the one i bought from amz was white... it worked fine. Maybe i'm missing something there, but it just seems ok.

  • @destroyingtheworksofthedev9349
    @destroyingtheworksofthedev9349 4 месяца назад

    Hi my brine tank seems to be low as in the level. For instance the level is sitting like 2 feet below the release valve, is this normal?

  • @rodneysanborn3183
    @rodneysanborn3183 4 месяца назад

    On the turbine, / paddle setting, I have neither, I just bought the 5600, I have no other attachments, what would my setting be? And are any other settings I should know?

  • @blockfather1375
    @blockfather1375 5 месяцев назад

    I followed these settings but my air injection head unit still spits water out of the air port before RR and then at the end before brine fill. brine fill is set to OFF and I now have all the settings the same as described in the video. any thoughts on why it insists on spewing out water for a few seconds at the start and maybe 15-30 seconds at the end of the cycle? thanks

  • @RomanKocherovsky
    @RomanKocherovsky 5 месяцев назад

    is the guy doing the demo Marc Ribillet 😁. Also, very helpful video.

  • @stephensaenz463
    @stephensaenz463 5 месяцев назад

    How do you turn it on

  • @trevorrussell7679
    @trevorrussell7679 5 месяцев назад

    Maybe a silly question, but is it possible to back-flush/drain back into the well itself? My system is not near my septic and I know it’d be putting debris back down, but didn’t know if it would be rough to filter back through or not.. also how many gallons does the backflush typically use?

  • @wsurfer2147
    @wsurfer2147 5 месяцев назад

    Thanks for the video, What to do if the controll valve electronic no longer function (broken) ?

    • @AplusWaterLLC
      @AplusWaterLLC 5 месяцев назад

      If the system is unable to be regenerated, you'll need to depressurize the entire home. To do this, you'll want to shut the main water off and run a faucet until there is no water left. Hope that helps! -Aplus Water

    • @wsurfer2147
      @wsurfer2147 5 месяцев назад

      @@AplusWaterLLC Thank you for the info. I have another question. My 5600 sxt screen is dead, I change the 24vac power supply but that didn't help. Is the controll board bad?

    • @AplusWaterLLC
      @AplusWaterLLC 5 месяцев назад

      @@wsurfer2147 If replacing the transformer did not help, there is a good chance that the circuit board is to blame for no power to the valve. (assuming the outlet that the system is plugged into is working properly)- Aplus Water

    • @wsurfer2147
      @wsurfer2147 5 месяцев назад

      @@AplusWaterLLC Thank you. I replaced the transformer but it also died. Because i think there is a short somewhere in the controll head. The original tramsformer died. I did check the outlet by plugging a light and it was fine.

  • @Partsunknown426
    @Partsunknown426 6 месяцев назад

    Is this a 9 x 48 tank? is that why a 40 min air draw? plus does the air draw push most of the water out of the tank in that time?

  • @pkdude5334
    @pkdude5334 6 месяцев назад

    should the softener or AIO be regenerated first? does it matter?

    • @AplusWaterLLC
      @AplusWaterLLC 6 месяцев назад

      Hi, It does not matter at all which one regenerates first, they just cannot regenerate at the same time! -Aplus Water

  • @stapler40
    @stapler40 6 месяцев назад

    What is the lifespan of the 5600sxt? I ask because I currently have one installed in my home, which is about 15 years old. So, how does one determine the condition of the unit. I've never had any errors with the unit in 15 years, but is it time to swap out for a new 5600sxt. If I do decide to swap out, should I buy the entire device, or do you think I would only need a tank? Thank you for any help you can provide.

    • @AplusWaterLLC
      @AplusWaterLLC 6 месяцев назад

      Hi! It really depends on water quality and water usage for how long a system may last. The only way to know it is time for a new one is when the old one goes out on you. If your current system is running fine, there's no reason to upgrade just yet. Whether you buy a complete new system or just new resin is up to you! There are benefits to both, such as new warranties on a new system or saving on cost by doing just resin. Feel free to give us a call and pick our brains regarding your situation. We are happy to help!- Aplus Water

  • @logikalx
    @logikalx 7 месяцев назад

    Thanks for the video, I saw my tank was full and just hit regen in panic. So that did nothing but while it was trying to do its thing i was able to pull the float system and syphon almost all of the water from the brine tank, so even if its not fixed at least it wont overflow before I can get a technician out!

  • @duckhunter8387
    @duckhunter8387 7 месяцев назад

    Well done!

  • @freddyrojas6956
    @freddyrojas6956 7 месяцев назад

    Any chance to get a model 9500 programming help

  • @felixandanavelazquez9245
    @felixandanavelazquez9245 7 месяцев назад

    I have the same unit that the clock is set to 24 hours instead of 12. How I can change to 12 hours.( I can not see the pm icon)

    • @AplusWaterLLC
      @AplusWaterLLC 7 месяцев назад

      It sounds like the display format on your system is set to Liters instead of gallons. You will just set the clock to 12:01 and hold both arrow buttons down until DF LTR pops up. Change this setting to DF GAL and the clock will read in gallons and the 12 hour clock. Give us a call if you're still having issues!- Aplus Water

  • @johna.ludwig2311
    @johna.ludwig2311 7 месяцев назад

    First of all, thank you for making it clear about the 12:01.......I tried with the correct time of day with no success. The rest is programmed ok but how do you program the NUMBER OF GALLONS BEFORE REGENERATON? Mine just has four dashes. - - - - What does that mean and how do I program it?

    • @AplusWaterLLC
      @AplusWaterLLC 7 месяцев назад

      The number of gallons should automatically be configured based on the capacity of the system, the hardness of the system, and the reserve setting. If you have the hardness cranked way up and the capacity set way low, you will experience the dashes. I would double check that your settings are set accurately. If you are still struggling, give us a call! - Aplus Water

  • @zachhopkins9719
    @zachhopkins9719 7 месяцев назад

    Thank you very much!!! Took a while to find your video. Everyone else was telling me to flow out lines that are probably blocked. Did two regular regeneration without using a shop vac to suck out the water to be below the float. I have three tanks total, two control heads but I believe the one that looks most similar to yours is a double unit and step 2 is brine/rinse. Jumped to that and see movement down in the brine well which I wasn’t getting before. Might not be fixed but thanks for providing an alternative troubleshooting method that sounds like I should have tried first if it’s that common

  • @HooverFamily-nn8di
    @HooverFamily-nn8di 7 месяцев назад

    Can you replace the manual valve control with a digital one?

    • @AplusWaterLLC
      @AplusWaterLLC 7 месяцев назад

      Hi! Yes! Most of the time, replacing a mechanical valve with a digital valve is an easy, direct swap. - Aplus Water

  • @ajeshrama2419
    @ajeshrama2419 7 месяцев назад

    During the last four years, we have had no problems with the same model, but now we are experiencing continuous drain, and softener tank is completely empty, would it be possible for you to suggest any solutions?

    • @AplusWaterLLC
      @AplusWaterLLC 7 месяцев назад

      Hi! Continuous leak to the drain is usually a red flag that the main piston seals of the valve are either worn down or compromised by debris. Once you replace/clean those seals, you should be back to normal operation. Hope that helps! - Aplus Water

    • @ajeshrama2419
      @ajeshrama2419 7 месяцев назад

      @@AplusWaterLLC thank you brother

  • @k50159
    @k50159 8 месяцев назад

    Much appreciated

  • @jimrudenberg6099
    @jimrudenberg6099 8 месяцев назад

    Thanks, This worked well! Very thankful.

  • @joeala762
    @joeala762 8 месяцев назад

    What if don't know how hard your water is?

  • @matjusz8985
    @matjusz8985 8 месяцев назад

    Can I adjust the hardness later on?

    • @AplusWaterLLC
      @AplusWaterLLC 8 месяцев назад

      Hi! You can always go back and adjust the hardness in the programming!

  • @3rdBNDeltaCo
    @3rdBNDeltaCo 8 месяцев назад

    What size are the O-rings?

  • @robertmartin4780
    @robertmartin4780 8 месяцев назад

    Please, this is a good video telling me nearly all I need to know. But what precisely should I see inside the tank before, during and after changing the media. If the time has come to change and I shine my light will I see a residual level of calcite or am I seeing internal tank structure? What am I actually seeing when the tank appears to have some calcite in it up to about a foot from the bottom? How much water should I remove before adding more calcite? Just above the shadow of existing calcite? Fill with new calcite to within six inches from top of tank? Thanks much. I'm about to service my filter in my crawl space and want to be assured of the proper procedure.

  • @FiveMinutesWithATechnician
    @FiveMinutesWithATechnician 9 месяцев назад

    Why do you not recommend using the smaller mesh screen in the brine line kit? 9:31

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Great question! We notice they tend to get clogged pretty easily causing a loss of pressure through the system. It just ends up being a hassle to clean it out every so often rather than just leaving it out. Hope that helps!!- Aplus Water

  • @aquariuswithfire
    @aquariuswithfire 9 месяцев назад

    Do these units require periodic maintenance and is so how often? TY Great Vid BTW!

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Hi! We recommend periodically cleaning the injectors and the drain line flow control washers. If you have iron in the water, we recommend this about once a year or so. We have videos on how to access these as well on our channel! Glad to hear you're enjoying the videos! Thanks! -Aplus Water

  • @christophe3281
    @christophe3281 9 месяцев назад

    Is the turbine valve necessary if it’s an AIO that recharges every 3 days anyway?

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Hi! An air injection system will not use a meter. It runs strictly on the day override setting. Hope that helps! -Aplus Water

    • @christophe3281
      @christophe3281 9 месяцев назад

      @@AplusWaterLLC thanks for the reply!

  • @snipex111
    @snipex111 9 месяцев назад

    Should i depressurize and bypass when going on vacation?? Say 7 days ?

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Hi, If you're only going to be gone for a while, just unplug the system from the outlet. This will prevent it from regenerating while you're gone. No need to depressurize or bypass the system! Whenever you get back, you'll just plug the valve back in and reset the time of day. The programming will remain indefinitely for you. Hope that helps! - Aplus Water

    • @snipex111
      @snipex111 9 месяцев назад

      Yes thank you

  • @paulh6591
    @paulh6591 9 месяцев назад

    Does Fleck sell a wrench to remove the head assembly? I have an oler model, and even after releasing pressure, it's on too tight to unscrew by hand.

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Unfortunately there are no wrenches to remove the valve. It sounds like yours may have been overtightened when it was installed. Most of the time, the valve unscrews fairly easily by hand. I would say keep trying your best, but be very careful not to damage the threads of the tank! If the threads are damaged you'll need a whole new tank. If you end up installing a new valve (or reinstalling your old one), be sure to only put the valve on until it is snug and secure. Also, be sure to not use any sort of pipe dope or teflon tape on this connection. A little lubricant and some elbow grease should get the valve on just tight enough to have a secure connection without making it impossible to remove the valve in the future.- Aplus Water

    • @paulh6591
      @paulh6591 9 месяцев назад

      @@AplusWaterLLC Thanks- maybe I'll use a strap wrench. That Fleck 5600 SXT digital head you have here... would it be a direct swap for my old motor-drived 14-day Fleck brine unit unit, so I can keep the old tank, which still looks good? The old Fleck had developed a hairline weep leak, I'm tired of hearing the little clock driver motor, and the unit hasn't been serviced for years so I need new beads anyway. While I'm at it I'd like to update the head unit. My other option would be to not use a softener- I've had this one on bypass for the last few months, now I'm toying with discarding/gifting it or fixing it up.

    • @pefferie
      @pefferie 3 месяца назад

      I stick a scrap of copper pipe into an inlet port for leverage

  • @christophe3281
    @christophe3281 10 месяцев назад

    Are the valve heads interchangeable for a softener to an aio? For example, could you use the 5600sxt softener valve for an aio if you reconfigure the program and add a check valve where the brine draw would connect?

    • @AplusWaterLLC
      @AplusWaterLLC 9 месяцев назад

      Hi, The valves are built very similarly, but to convert the softener valve to an air injection valve, you would need to reconfigure the programming, add a check valve where the brine line connection is, replace the flow controls to suit the difference between the softener resin and the filter media, and add a check valve to the inlet side of the valve (to make sure your air pocket does not escape). A lot of times, it ends up being fairly close (if not better) in price to buy a brand new system than try to convert everything over. Hope that helps!- Aplus Water

  • @christophe3281
    @christophe3281 10 месяцев назад

    Is this the same type of valve that’s used for an air injector for iron filters as well as softeners?

  • @scottcarter9975
    @scottcarter9975 10 месяцев назад

    I am so confused! On the hardness setting. Our hardness is 2.5 grains per gallon. I understand that three is the maximum you want. Our iron is 0.15 ppm. I understand that 0.3 is the maximum healthy. These numbers are so different from your description. Am I misunderstanding something? Thanks.

  • @JamesDThomas1981
    @JamesDThomas1981 10 месяцев назад

    Excellent video. I had to disconnect my water softener so I can get my garage floors painted. So when I went to go put the water softener back in I need a directions on how to set up. The best I've seen thus far.

  • @MarkPeterson-u2x
    @MarkPeterson-u2x 11 месяцев назад

    Had the 64,000 unit, it has run 2 cycles since it was installed about 3-4 weeks ago, last cycle a couple days ago. Level fills to about 1100, now down to 90 in 2 days, also says "rc" with blinking water faucet, what's going on? Of course always on weekend when you can't call anyone.

    • @AplusWaterLLC
      @AplusWaterLLC 11 месяцев назад

      Hi, "rc" stands for reserve capacity. This means you are currently using the reserve of soft water that the system has built in through the programming. This is just to ensure you do not run out of soft water halfway through the day. When you see "rc" a regeneration gets queued up to occur later that night, hence why you see the blinking water faucet. 1100 gallons down to 90 in 2 days is really quick. This could be correct if there are a lot of people using the water. If you haven't already, though, I would double check that the programmed settings are correct and your hardness number is accurate. If everything looks accurate and you don't have a ton of water usage, check for leaks throughout the home (possibly a leaky toilet or something like that). We are in the office Monday - Friday 9am-4pm CST. Give us a call if you are still having issues! - Aplus Water

  • @wilholland100
    @wilholland100 11 месяцев назад

    Question, My plunger on my Aquasure system is very stiff and doesn't want to move up and down. It is a fairly new system. I'm afraid it is so stiff that it may break the plastic wheel. How easily should they move up and down?

  • @DavidPickwell-f9p
    @DavidPickwell-f9p Год назад

    You skipped an important setup step there bud. You set the people thing, but left out the gallons of capacity setting from the Clarke Chart. Should have set dial ring to 14 gal, lined up with the white dot there (based on the 4 people and 20 hardness) --- you left the gallons of capacity at 9 gal, not right. You don't know what you are doing.

  • @viperflyer
    @viperflyer Год назад

    It doesn't make sense to set it to regenerate everyday. So wasteful of water as Fleck is running water for 1 hour during "air draw" step. I have been using air injection systems to regenerate every 5 to 7 days between 2 different houses. My iron level was pretty high as it would start to smell in a month after chlorination of the well.

    • @AplusWaterLLC
      @AplusWaterLLC Год назад

      While it's great to hear that regenerating less often works for you, that is not the case for most applications. After the third day without regenerating, the air pocket within the tank starts to disappear. The media used with these systems usually does have oxidizing properties which helps with iron removal but It tends to get loaded up fairly quickly if not backwashed often. Of course, everybody's water quality and water usage will affect the system's performance, so it's really a matter of finding what works best for you! These settings are what we recommend to ensure the best possible water treatment and iron removal. - Aplus Water

    • @christophe3281
      @christophe3281 10 месяцев назад

      I wish they made seals and spacers more durable. I have to change mine again and it’s only been 8 months. Waiting on the parts to arrive.

    • @viperflyer
      @viperflyer 10 месяцев назад

      @christophe3281 I would make sure that both bores and o-rings are lubed before the connection is made. Plus, make sure that elbows connecting solid pipes and the inlet/outlets are leveled....best to use flex hose.

    • @christophe3281
      @christophe3281 10 месяцев назад

      @@viperflyer thanks for the reply!! I have the same issue with water quality. I’m going to try regeneration every 4-5 days as opposed to what it is now for 3 days. It’s a lot of wear and tear. Thanks again for the advice

    • @Gr33nScr3w
      @Gr33nScr3w 5 месяцев назад

      How much total water is used each day for a regeneration?