Vintage PC - 10MHz PC XT compatible, Part 1, Bringing back to life...
Can a 20+ year old PC, sitting unused for about 10 years still work?
Will there be fire, frustration, fond memories, or all of the above. Lets take a look...
Просмотров: 248

Видео

WARNING - Tinker Time, Compact Fluorescent Lamps
Просмотров 896 лет назад
I decided that there needed to be more emphasis on safety with regards to the Mercury content. This video hopefully corrects this. I have also included some unseen footage with regards to removing stubborn glass tubes. Links: www.environment.gov.au/protection/national-waste-policy/mercury-containing-lamps www.epa.gov/cfl/cleaning-broken-cfl
Tinker Time, Compact Fluorescent Lamps
Просмотров 746 лет назад
This is an examination of a number of Compact Fluorescent Lamps (CFLs), particularly noting the High Voltage Transistor parts being used. After noticing an Optically Triggered TRIAC (MOC3021), an investigation of the circuit follows. Notes: At around 9:40, I begin to talk about the CFL_Harmonics paper, dated May/June 1993. I was misreading TABLE II, and therefore misrepresenting the data. There...
Repair of LG 42LW5700-TA LED TV, Part 5 - It does compute
Просмотров 8 тыс.7 лет назад
This is the first of the long awaited videos on remotely operating and accessing the TV and it's operating system. In this video, I show how to use the Device Control interface and the serial Console, specifically for TV's with Firmware 3.06.04. With later versions of the Firmware, LG has progressively disabled these things, and in later videos, I will show this. Enjoy.
Tinker Time: Warbling Indicator
Просмотров 627 лет назад
This is an examination of two, single Transistor oscillators. The circuit is arranged so that the low frequency oscillator adjusts the audio frequency, producing a warble, and a flashing LED. A simple and yet intriguing circuit.
Repair Oscilloscope Probe
Просмотров 10 тыс.7 лет назад
Repair of a 100MHz Oscilloscope probe lead. Surprisingly, I could find an appropriate video for something that seemed so simple. In this video, I experiment with a time-lapse, Picture-in-Picture stream. I suppose it could be deemed a blatant attempt to double the number of views. Especially if I were to ask viewers whether they noticed anything inappropriate in said stream. There isn't... or wa...
Repair of DGTEC DG-HDPVR5009 Power Supply
Просмотров 3597 лет назад
Repair of a Personal Video Recorder's Power Supply. I had already performed an initial diagnosis and removed the power supply module before starting this recording. But I show the testing of the Electrolytic Capacitors, and their possible replacements. Be aware that parameters such as Equivalent Series Resistance (ESR) are Temperature dependant, as seen here, when measuring the faulty 470uF Cap...
Repair and Testing of SMITHS RVC 1002/00F Tachometer
Просмотров 8 тыс.7 лет назад
Join me as I examine, repair, and test this old, late 1970's Revolution Counter.
Multimeter Calibration, Metex M-3650 (1989)
Просмотров 13 тыс.7 лет назад
After repairing this Multimeter, I now calibrate and Test. I close the video by examining the hFE circuit.
Multimeter Repair, Metex M 3650 1989, Part 2
Просмотров 5 тыс.8 лет назад
In Part 2, I recap relevant bits of Part 1, then show the results of the Acetone on the Hybrid module at various points in time, cleanup and then reverse engineer it's circuit, cringingly "repair" the module, reassemble the meter, and then finally check it's current consumption and low-voltage detector. Calibration is next on the list.
Multimeter Repair, Metex M 3650 1989, Part 1
Просмотров 13 тыс.8 лет назад
I begin with a bit of history. Then introduce basic Liquid Crystal Display (LCD) operations, remove a hybrid package (Metex SDG-HD-03AR), and then remedy an unreliable selector position. I finish up Part 1 with a bit of tinkering, measuring LCD pixel\element Capacitance.
Repair of LG 42LW5700 TA, LED TV, Part 4
Просмотров 21 тыс.8 лет назад
I continue the repair from part 3. This time I show the heat testing, and then deal with a failure of the the LGE35230 BGA (AKA Broadcom) chip on the Main board again. Please note an error I make at ~14 minutes in. To log ANSI codes using Tera-Term, you need to choose the "Binary" option, not "Plain Text" when in the "Tera Term: Log" dialog.
Repair of LG 42LW5700 TA, LED TV, Part 3
Просмотров 29 тыс.8 лет назад
I continue the repair from part 2. This time I move to the Main board and reflow the LGE35230 BGA chip. I also try repairing the split rubber speaker surrounds.
Component Testing, Testing MOSFETs with Multimeters
Просмотров 2,8 тыс.8 лет назад
How to test basic MOSFET operation out-of-circuit, and possibly in-circuit
Repair of LG 42LW5700 TA, LED TV, Part 2
Просмотров 26 тыс.8 лет назад
I continue the repair from part 1. Eventually I realise that I made a mistake with regards to the working voltage of the back-light, and go from there.
Repair of LG 42LW5700 TA, LED TV, Part 1
Просмотров 67 тыс.8 лет назад
Repair of LG 42LW5700 TA, LED TV, Part 1
Install or Remove laptop memory
Просмотров 5949 лет назад
Install or Remove laptop memory
Parallel Port LEDs
Просмотров 1929 лет назад
Parallel Port LEDs
WDC500, open case
Просмотров 2999 лет назад
WDC500, open case
Faulty IBM 2.5 HDD without lid 01
Просмотров 1319 лет назад
Faulty IBM 2.5 HDD without lid 01

Комментарии

  • @EvanTuer
    @EvanTuer Месяц назад

    Thanks Richard. With these clues I was able to repair and calibrate an RVC 2415 tach, the chip had died but I found the SAK215 replacement on ebay.

  • @matejhlaca5171
    @matejhlaca5171 5 месяцев назад

    Helo..I have Metex ME-32 multimeter. Its 20 years old, but now I have a problem. If I shorten probes it shows -16mV. When I measure AA battery positive to positive it shows 1.3V when I change probes positive to negative it shows -1.6V. What can be wrong?

  • @ct1emt
    @ct1emt 10 месяцев назад

    tenho um multimetro igual e nao consigo calibrar Metex M-3650 ja o tenho parado ha varios anos

  • @audio.0-07
    @audio.0-07 11 месяцев назад

    Mucho tiempo para no hacer prácticanente nada . El tiempo es oro

  • @agramcroatia4185
    @agramcroatia4185 Год назад

    This is a multimeter. I have had it since 1988. Precise and unbreakable, and I use it often.

  • @zbyszekpodchmielony2642
    @zbyszekpodchmielony2642 Год назад

    Thank you very much for the much appreciated video of the repair of this further good meter. I damaged a few days ago the hybrid for measuring capacitance, in this condition it blocked the correct measurements of other parameters. Thanks to your video I regained my "right hand" and a friend!!! which is already 30 years old!!! - multimeter is already working and the hybrid "softens " in the jar hi hi Thank you very much and greetings 👏👏👏👏👍+ sub 🙂

  • @DaPulsarMan90
    @DaPulsarMan90 Год назад

    Would you have a complete power board for one still? Mines died & I definitely don't have the know how to do all that

  • @zekiyaniz3970
    @zekiyaniz3970 2 года назад

    Süper Technologies dijital multimetre

  • @holgergollnitz4275
    @holgergollnitz4275 2 года назад

    what is the Zero adjust button, please. Reading ist mostly 6 digits at zero V A mA

    • @BrainHurricanes
      @BrainHurricanes Год назад

      When you put the meter in any CAP mode, the display isn't showing zero. With the Zero Adj you can set it to zero, before measuring a cap.

  • @ct1emt
    @ct1emt 2 года назад

    tenho um multimetro igual e nao o consigo calibrar nao sei onde mandar reparar ja tem muitos anos sempre funcionou bem

    • @ct1emt
      @ct1emt 2 года назад

      metex

    • @ct1emt
      @ct1emt 2 года назад

      m-3650 deixou de funcionar liga mas nao mede ou mede mal

  • @carlosa881953
    @carlosa881953 2 года назад

    Too bad, the Spanish subtitles don't work.I am from Colombia (South America).

  • @PauloCesar-yn1uo
    @PauloCesar-yn1uo 3 года назад

    Bom dia gostei muito de ver o seu vídeo do jeito que vc explica , por favor mim ajude , tenho uma tv LG 42lw4500 tem áudio mais não tenho imagem, e eu não tenho esquema dela. Onde posso encontrar esse esquema PCB P/N: EAX62865401/8 REV1,0 e qual é o valor desse resistor 102 na placa, por favor traduzir em português

  • @lotm666
    @lotm666 3 года назад

    Hello Richard. Nice and instructive video. I am looking to find a way to use a signal from the rev counter in order to use it as an input in a monitoring device, software programm. I would like to find a voltage which I could convert into RPM. Is there such a signal in this circuit, or is the meter working with an output current and not voltage? Thanks a lot!

  • @surewill8190
    @surewill8190 3 года назад

    i also repaired this model tv , with reheating the chip , thanks for you video and time take to do , it would have a lot more time than what the tv is worth but the information gained was very good , if this fails again i have found iphone 12 stensil for reballing of this chip , i also not like how lg have mounted the heatsink , with plastic spring loaded clips and metal springs on the board , replacing these and placing heatsink compound , surly help this chip as well

  • @Treytrxy
    @Treytrxy 3 года назад

    Bit risky being that rough with a motherboard might scratch the circuit

  • @erhanabdullah2619
    @erhanabdullah2619 3 года назад

    Thanks

  • @trickedouttech321
    @trickedouttech321 3 года назад

    The fine wire is not to be soldered on any scope probe it will change the specs especially the resistance of the probe, very tiny amount however it is the same process for all major brand probe.

  • @oscarflorez6073
    @oscarflorez6073 3 года назад

    Excelente me ayudo con una placa igualita y me cirvio

  • @sajjadmirzaee17
    @sajjadmirzaee17 3 года назад

    Hi I am a repairman living in Iran Please help me fix the TVs LG 42 W TV, only its red standby LED light is on and it does not turn on anymore ... I tried to control the remote and the buttons, but it did not turn on Please tell me how to start troubleshooting Thank you very much

  • @clement3015
    @clement3015 3 года назад

    tem como traduzir para português

  • @stp715a
    @stp715a 3 года назад

    Great video. Thank you. Cannot figure out how to remove the selector switch knob to access bottom PCB. Really appreciate any tips on how to remove. Thank you.

  • @wendelljackson1488
    @wendelljackson1488 3 года назад

    I found it quite frustrating and almost useless to try to listen to your description, watch intently what you were doing on the main screen, and then try to follow what was happening in the picture-in-picture. I wish you had simply described and shown step-by-step what you did.

  • @JulianT1972
    @JulianT1972 4 года назад

    Nice video, how long has this repair lasted?

  • @jnking2000
    @jnking2000 4 года назад

    Hi I was hoping you could help I'm looking for the correct internal settings for the hidden/ secret menu as mine has been messed up, this is for 42LW5700 Thanks

  • @Bennybruss
    @Bennybruss 4 года назад

    my tv of this exact model just stopped working and won’t turn on, red power light just keeps getting bright then going off like a pulse.. any help please anyone??

    • @NSVMohith
      @NSVMohith 4 года назад

      You will need a new board.

  • @TheMMARKO93
    @TheMMARKO93 4 года назад

    Hi, this is a great video. I have the same multimeter and my lcd anounciator values are jumping up and down regardless of leads imputed in the meter or not, touching or not aswell. The numbers keep changing in every selection, Ohms DC, AC, what ever. I would be really grateful to hear some of your thoughts on the matter. What could be the problem. Thank you in advance.

  • @withamara3206
    @withamara3206 4 года назад

    thank you for your help. can you help me find the motherboard? do u sell it?

  • @eonflask8904
    @eonflask8904 4 года назад

    Hi, Sir Richard, I have the same model and only and as per my checking I get 24V, 3.55V,2.4V and 36V on the powersupply. my questions is what would be the next move for it?

  • @lakshminarayanann393
    @lakshminarayanann393 4 года назад

    Dear Richard, thanks for analysis. What would be the current required for 36V Led backlights. I mean total current for 108 LEDs.

    • @eonflask8904
      @eonflask8904 4 года назад

      Hi I would like to know if you already fixed your issue?

  • @rickd6657
    @rickd6657 4 года назад

    Thanks for sharing your knowledge. I have the 1994 version (grey casing) briefly shown at the beginning of the video - purchased at Dick Smith. Because of the name Metex, I mistakenly though it was German...hehe. It's got pat. pending US and Germany on the back. I like this 25yo meter although it's only 2000c (3-1/2 digits). Recently it developed a fault with reading AC voltages. Measurements on all scales were ~30% off. e.g. 178v reading for 240v mains. The ADC chip works on VDC only so VAC first needs to be converted and scaled. The designers couldn't fit all of the circuitry of the AC-to-DC converter on the main board so they resorted to using a vertically mounted extension PCB, naming it ADC-HD-201CR. Luckily the fault turned out to be caused by 2 bad 10 uF/16v caps (C6 & C9 on the main PCB). The approach used was to test the main board components of the AC-to-DC converter in-circuit, and then remove and re-test the ones with no or suspect readings. I'm glad I didn't have to go through the trouble of removing an extension PCB like you need to do. Finding your videos helped me repair the meter.

  • @elektrojen7347
    @elektrojen7347 4 года назад

    My multimeter name's voltgraft. Its a metex m 3650. And very good a device. Video is very professional

  • @miguelmdn7
    @miguelmdn7 4 года назад

    Mister, where can I get a new main board of Lg 42LW5700 ?

  • @josea.esteve7805
    @josea.esteve7805 4 года назад

    Que tal, se me estropeo mi tester Metex, no me mide el microamperimetro, no cambia la escala. No se si peda ayudarme

  • @anwarst9163
    @anwarst9163 5 лет назад

    Thanks, it's work at my LG 42LW5700 but i baked the main board in 200°C in 10 minutes. Thank you very much sir

  • @anilkumarsharma1205
    @anilkumarsharma1205 5 лет назад

    tachometer reading formula for hours on one tenths kya hain, koi frequency factors hain jo real time according to your wrist watch and hours of work by tachometer hours meter main bantee ho, koi correlation ho, saari dunia main pollution control hoga issey

  • @anilkumarsharma1205
    @anilkumarsharma1205 5 лет назад

    how rpm and hours of work related with real time according to your wrist watch ,please discussed it with me so all world wide crane operators take a lesson

  • @ramiroraigosarodrigues7442
    @ramiroraigosarodrigues7442 5 лет назад

    Por favor

  • @ramiroraigosarodrigues7442
    @ramiroraigosarodrigues7442 5 лет назад

    Lastima lo necesito en español seria posible?

  • @LookingMercury3D
    @LookingMercury3D 5 лет назад

    My Voltage to the Leds reads 50V but in yours 36V.. What is the correct Voltage?

  • @paulomorales
    @paulomorales 5 лет назад

    Thanks a lot, i repaired not one but two dead TVs of mine with your method ! Thanks for sharing your knowledge !

  • @eddejesus5420
    @eddejesus5420 5 лет назад

    Model number 42lw5700-ue the screen got distorted to no picture but it still has sounds.

    • @pasmas3217
      @pasmas3217 5 лет назад

      did u find anything about fixing it? i got 42lw570s, with similar problem. no picture just some lines that never move, but it still has normal sound any info (cost official and or unofficial, (location), diagnosed problem source...) would be welcome thanks

  • @maurizio700
    @maurizio700 6 лет назад

    Very Interesting video. It was useful to calibrate my Metex 4650 in the DCV range, unfortunately the 2 Volts scale is not accurate and alligned with the others example (200mv, 20v, 200v). My M4650 has two extra trimmers, one below the display and the other at the center of the four holes inputs and that are absent in your M3650. As you know do you think should be one of these two trimmers able to calibrate the scale of 1,9999 resolution. Thank you. 😉😊

    • @richardrudek01
      @richardrudek01 6 лет назад

      Just the 2V range ? It's unlikely, but I don't know. Before going much further, you need to know that the Meter is in good condition. A Meter is something you need to be able to rely upon. Or at the very least, know what NOT to rely upon. A quick Google search for a schematic brought me to a page on Elektrotanya - you need to wait for the link to become live: elektrotanya.com/metex_m4650_cr.pdf/download.html The schematic looks like it might be legit. My suggestion is to (safely) download the schematic, and work out whether it can help guide you. Looking at the schematic, the first thing I saw was that they are using a two-chip setup: one for the Measurement and one for the Display. I then found a user manual and saw that it is a 20,000 count meter. So, um, yeah. If the problem is just the one range, then it could be Bad\Dirty switch contacts, dirty PCB, or other things related to that specific range. It's unlikely to be out-of-spec Precision Resistor(s), because that usually effects all ranges, though it is possible. It could be damaged protection circuitry. It could even be Electrical noise, such as Radio (Mobile\WiFi\etc) or Hum pickup. So, experiment: with\Without the Leads, Faraday shielding the meter, etc. ONLY AFTER YOU KNOW the meter is Good, or what is not good, do you Calibrate.

    • @maurizio700
      @maurizio700 6 лет назад

      @@richardrudek01 The deviation is minimal but unacceptable if I'm not mistaken, it has a factory tolerance of 0.05%. Ex. 2v range i have 1.3185 20v range i have 1.315v I have another DMM 4650B where the two range are alligned. Where the problem? 😕😔

    • @maurizio700
      @maurizio700 6 лет назад

      @@richardrudek01 Hi Richard, as your suggest assuming that no adjustment trimmer for 2v interval exists, for our curiosity I centered the calibration around 200mv and then up to 3,000v however already arriving at 5v begins to lose two counts and then to 10v and four counts lose. Can we suppose there is a circuit failure? Or still a compensation trimmer would be perfect in the case? So, my curiosity pushes me further and I would like to experiment moving on the two trimmer left that you do not have on your M3650 but at high risk of putting out of alignment in something else. ☹ Thank you for even going search for the manual I found it too but that scheme goes far beyond my competence.

    • @richardrudek01
      @richardrudek01 6 лет назад

      Four counts out of 20,000 is 0.02%. That is well within spec. Note that when you start getting down to levels of accuracy like this, environmentals such as Temperature and Humidity can affect the results. More than once have I seen readings fluctuate with people simply breathing on the meter... So whether there IS, or IS NOT a circuit problem is something that YOU need to consider and decide. Things to consider, though, is the condition of the Meter. Has it been physically or electrically abused. Is it 'dirty'. Often, you are left with little choice but to open the Meter and inspect it. But if that is not an option, then you are left with rigorous testing, perhaps within test chambers that are shielded and environmentally controlled - temperature, humidity, pressure, light, etc. Now when it comes to experimenting. Just be sure you are able to live with any possible outcomes. In this case, however, we do have a schematic that seems like it is mostly correct. You should be able to find each of the variable resistors in the schematic, then find them on meter, and figure out what it is likely for. For example (Guesses): - VR1 seems to be setting the zero point. - VR2 perhaps AC voltage. - VR3 perhaps Capacitance. - VR4 and VR5 the Frequency counters.

    • @richardrudek01
      @richardrudek01 5 лет назад

      Oh. So you are comparing between ranges on the SAME meter - the M4650. Interesting. Yes, I missed that point. I'll get back to that point in a minute. The schematic I have for M4650 seems to confirm that the basic accuracy is set by the precision resistors, ALONE - like with the M3650 in my video. Thus, if there is a discrepancy in one, and only one range, then the voltage divider network made using the precision resistors is where you need to be focusing. However, whether or not you can do something about it is another thing. For example, if you find that the precision resistor between the 200mV and 2V ranges is out of specification, are you going to disassemble the network and fix it ? Now back to the earlier point about comparing between ranges. In the video, I compared "the standard" with the "subject". That is the Voltcraft Meter AND the Test Source, with the Metex. Notice how I emphasised the "AND". When you calibrate using a Source and a Reference meter as "the standard", one thing you can miss with that set up is the interaction between input and output impedances. Now both Meters should have input impedances that should be in the 10M Ohm range. But you can be surprised by the effects, if your not vigilant. To put some numbers one it - and these could be wrong, so please double check. How high does the (output) source impedance (Rs) need to be to produce an error of 40 counts with 10M Ohm input impedance (Rm)? There are many ways to figure this out. If the source impedance is much, much lower than the input impedance, then the simple ratio method is close enough. But the more correct method is by considering a voltage divider circuit. With the simple ratio method, 'simply' multiply the input impedance by the ratio of the error. So 40 counts / 20,000 counts * 10,000,000 Ohms = ~20,000 Ohms. Interesting, there is symmetry in these numbers - 20K counts, 20K Ohms... Lets double check this using the circuit method. We have a source producing a Voltage. We'll call that Vs. Then we have a source Resistance (Rs) in series with the Meter's Input resistance (Rm). The meter then completes the circuit by connecting the 'COM' lead back to the voltage source. So, ASCII art circuit: (Vs)---< Rs >---o---< Rm >---. |__________________________| So lets make Vs = 1V. Vrs [across Rs] = 1V / 20,000 counts * 40 counts = 0.002 V Vm [across Meter] = 1V - 0.002V = 0.998 V Rs = Vrs/I I = Vm/Rm = 0.998 / 10,000,000 = 99.8 nA (99.8e-9) thus Rs = 0.002 / 99.8e-9 = ~20,040 Ohms. In short, if the output impedance of your test source is ~20K Ohms, you can expect to see a voltage drop equivalent to 40 counts by simply connecting your 10M Ohm meter across it. FINALLY: Sharing. You obviously already have a RUclips\Google account. In which case you should have a Google Drive. Log into your Google Drive, create some folders and share it and/or the specific pictures, publicly. Then copy and paste the link in a reply. Just make sure you limit the permissions on what people can do. For example, do NOT give editing\authoring rights to the public, just viewing rights.

  • @karanpandya2832
    @karanpandya2832 6 лет назад

    MODEL NUMBER 42LW5700-TA LG

  • @karanpandya2832
    @karanpandya2832 6 лет назад

    Sir my TV not starting relya no red indicated blinking but TV not starting plz help power problem aur (MB) mothar board problem

  • @TheRochlan
    @TheRochlan 6 лет назад

    Thank you for a series of very interesting videos. I've got a very similiar model (LG 42LW5500) that shows the same problems as yours did (power board seems to be ok). I will try reflowing of the main graphics chip using my resoldering hot air station. But since the chip itself seem to be genererally sensitive to temperature, in order to avoid it failing again I was considering to permanently mount one or two 4x4cm active fans outside the chassis (same as you did in the video when you did your temperature measuring). Since the TV offers 12V on the video board, I was wondering whether I could take the power for those fans directly from there (by soldering a 2-pin wire that leads outside of the chassis through one of those holes, where I would connect the two fans. Do you see any problem with such an approach?

  • @muralikrithiesh3218
    @muralikrithiesh3218 6 лет назад

    hello sir model nomber lg47lv3730-td smps back lite volt problem only,36volt no tv on red lite on slowly on plese help sir

    • @eonflask8904
      @eonflask8904 4 года назад

      Hi did you resolve your issue?

  • @MrSoden1947
    @MrSoden1947 6 лет назад

    Great video --can you tell me --we have a DGTEC HDPVR 320 - ok for digital channels - states HD --does that mean we can view/record HD channels --we tuned it in but only got sound -TV states HD -but doesn't show the channels

  • @priyabratanishanka5893
    @priyabratanishanka5893 6 лет назад

    Sir,I have 42LD650,,Main board fault,power indicator light is blinking.already 2 time heating by oven,but same problems running on 2 day's,how to solve this problem,pls suggest me how to order new main board.plz ans.my whatsapp number +919090309737

  • @coppelltvrepair
    @coppelltvrepair 6 лет назад

    This is a terrible way to "reflow" a BGA of this size and kind. It's not reflowing, really, it is merely expanding the balls so a contact is made; it'll fail within days or weeks and if anyone says they're happily running for months I simply won't believe them - been there, done that one too many times to take anyone's word. The only application of manual hot air "reflow" is with very small ICs like RAM chips where the area is so small and device is so thin and balls, accordingly, so little, that heat can get through the device to them and melt them while actually still providing enough heat to allow melt of the solder on the pads - something which simply won't happen with the 35230 and the air blower from this video. No hard feelings, the videos are without a doubt educational to many; still this is the wrong way to repair the problem, even though it would look like it works for a while.