Ian's Solar Projects
Ian's Solar Projects
  • Видео 46
  • Просмотров 543 495

Видео

Stark Varg 80Hp, Is it more Stark than Varg? Problems, and Opinions
Просмотров 5406 месяцев назад
We test the Range, Charger, wiring issues, range issues, cutting out issues etc
Load testing the 15kPV NHX 10kW Hybrid Inverter (Saw, Compressor & Ford Lightning) @ watts247
Просмотров 3,6 тыс.7 месяцев назад
We Run the NHX 10kW inverter through its paces. Using Silicate Gel Batteries Lithium Batteries Unbalanced load test with: Shop Air Compressor Chop Saw with locked Rotor 11kW of heat guns and finally charging a Ford Lightning Unit is UL1741 SA - Rule 21 approved and is in the California Approved List. Can be used for Grid Tie, Off-grid, Peak Shift etc . Features 4 x 500V - 3750W independent Sola...
Why we no longer sell Inverters With Auto Transformers
Просмотров 5 тыс.Год назад
Why we no longer sell Inverters With Auto Transformers
Well pump controller & Solar Rack
Просмотров 636Год назад
Well pump controller & Solar Rack
Watts247 Solar Panel array Mount 10 panel and 8 panel Array (5 x 2 or 4 x 2)
Просмотров 2,2 тыс.Год назад
Ground mount arrays are the way to go, keep your panels facing the Sun for all times of the year. Why choose ground mount over roof mount: 1) Less red tape (when you install on your roof, it becomes part of your house) 2) Makes them easy to Clean Dust and Snow off 3) Easy Azimuth Adjustment 4) Take them with you if you need to go 5) Make a shady spot in your yard and grow your veggies under the...
How to use a 100V Qcell 6.3kwh Battery on a 48V LV6548 Solar Inverter
Просмотров 1,9 тыс.Год назад
Qcell 6.3kwh batteries are doing their rounds, they are NMC 100V 2 x 14s configuration batteries that are easily configurable to work on 48V systems. watts247.com to get batteries I show you how to do it.
U5648 Ground Screw
Просмотров 1 тыс.Год назад
U5648 Ground Screw
LV6548 Generator Firmware Update
Просмотров 3,4 тыс.Год назад
A few customers have been reporting that the LV6548, is sensitive to generator charging, especially with non-inverter type generators. This firmware is designed to make the charging less sensitive to generator anomalies. BEWARE, only flash with the U1 version that matches the firmware, else your inverter will be useless. If you have purchased yours from watts247, we have the firmware for you. T...
Repairing a MPP Solar LV6048 6kw split phase inverter
Просмотров 9 тыс.Год назад
You could have more fun watching paint dry! Unless you don't have power - inverter failure , then you may wish you did watch this video :) Fault 81 and 88 at 39 min mark
Configuration of a LV6048 6kW split phase inverter from MPP Solar
Просмотров 8 тыс.Год назад
Configuration of a LV6048 6kW split phase inverter from MPP Solar
Solar Panel Series vs Parallel Part 2 (How to test each panel in an array)
Просмотров 1,8 тыс.Год назад
The most frequent solar question is, "we are getting solar volts, but the charge controller will not charge", maybe you have a bad solar panel, we show you how to test each panel in an array. Also show how to mix mismatched panels
Solar Panel Series vs Parallel Part 1
Просмотров 1,5 тыс.Год назад
Solar Panel Series vs Parallel Part 1
No Internet - Remote Solar Monitoring with cheapest Android Tablet wirelessly to Solar-Assistant
Просмотров 14 тыс.Год назад
Many of our customers ask us for a completely off-grid solution with Monitoring, this is how we did it. We bought a cheap Android Tablet, and got remote monitoring and logging of our Solar System without internet access, perfect for RVs Cabins and just about anything else. You can do the exact same thing on your phone, or old throw away phone. We also show how to heat water with all the excess ...
Solar Assistant - Data Logging on steroids - the All new Orange version with functional HDMI output
Просмотров 35 тыс.2 года назад
Solar-Assistant is a solar monitoring and logging system like no other, connects to most popular brand inverters MPP Solar, Sol-ark, Growatt, Deye, Must, Megarevo, SunSynk etc and a host Lithium Battery BMSs such as Trophy, Vestwood, SOK, Pytes, Shoto, Seplos, JK, Dyness, Daly and others. Here we show the new Orange Version which supports an internal web browser through the HDMI Port, we connec...
MPP Solar 3048LV-MK 2048LV-MK 1012LV-MK Overview
Просмотров 4,8 тыс.2 года назад
MPP Solar 3048LV-MK 2048LV-MK 1012LV-MK Overview
Techniques Paralleling LiFEPO4 Batteries together
Просмотров 12 тыс.2 года назад
Techniques Paralleling LiFEPO4 Batteries together
Growatt SC48120, SC4880, SC4860, 12000T to 4000T Calibration
Просмотров 2,3 тыс.2 года назад
Growatt SC48120, SC4880, SC4860, 12000T to 4000T Calibration
LV6548 Communications with Pytes & SOK Batteries out the box, Showing Fault 61 no flashing required
Просмотров 13 тыс.2 года назад
LV6548 Communications with Pytes & SOK Batteries out the box, Showing Fault 61 no flashing required
Pytes Battery Rack
Просмотров 2,6 тыс.2 года назад
Pytes Battery Rack
PYTES 5.1kwh 48V Rack Mount LiFePO4 battery configuration GROWATT off grid Inverters
Просмотров 16 тыс.2 года назад
PYTES 5.1kwh 48V Rack Mount LiFePO4 battery configuration GROWATT off grid Inverters
EMP Shield Installed in 2 minutes
Просмотров 3,8 тыс.2 года назад
EMP Shield Installed in 2 minutes
A closer look at Ground and Neutral Live Bonding on Growatt 5000ES
Просмотров 9 тыс.2 года назад
A closer look at Ground and Neutral Live Bonding on Growatt 5000ES
Solutions to Auto Transformers Dangers using 230V Inverters in North America
Просмотров 17 тыс.2 года назад
Solutions to Auto Transformers Dangers using 230V Inverters in North America
Inside look - Growatt 12000T 12kW and 6000T 6kW 48V 120/240V Inverter
Просмотров 18 тыс.2 года назад
Inside look - Growatt 12000T 12kW and 6000T 6kW 48V 120/240V Inverter
Dangers using Auto Transformers and 230V Inverters in North America
Просмотров 34 тыс.2 года назад
Dangers using Auto Transformers and 230V Inverters in North America
MPP Solar LVX6048 6kW Solar Inverter Battery-less Operation Overview Watts247
Просмотров 28 тыс.2 года назад
MPP Solar LVX6048 6kW Solar Inverter Battery-less Operation Overview Watts247
DIY Adjustable Ground Mount Solar PV Array 2 Methods
Просмотров 9 тыс.2 года назад
DIY Adjustable Ground Mount Solar PV Array 2 Methods
Amazing Solar Panel DC Arc 400V, Dangerous!
Просмотров 9 тыс.2 года назад
Amazing Solar Panel DC Arc 400V, Dangerous!
DIY EV Electric Vehicle Solar Charging station Intro
Просмотров 15 тыс.2 года назад
DIY EV Electric Vehicle Solar Charging station Intro

Комментарии

  • @dynamiccomputers2314
    @dynamiccomputers2314 7 дней назад

    Hi, I have the same battery (Qcell BAT63), but it’s been in the box for over two years and is now completely dead. The BMS isn’t activating, and I’m wondering if there’s a way to charge it or bring it back to life. Any advice would be appreciated. Thank you.

  • @UlyssesJanice-i6q
    @UlyssesJanice-i6q 17 дней назад

    Bednar Circle

  • @calsim3924
    @calsim3924 18 дней назад

    is it true that you can over amp the PV input as long as the voltage is in range? I'm hoping to get more power in the morning and evening from my over size panel. yes i know it will clip the peak but I'm ok with that

  • @renewyers4699
    @renewyers4699 Месяц назад

    Hi there from AUS. I I noticed that u r not using the growatt inverters any more is there a reason for that,as I'm using 4 growatt inverters for my power.cheers Rene.

  • @theblob3349
    @theblob3349 Месяц назад

    You have brought Extremely important things to mind that I did not consider, I have The exact same setup and Will be removing it from service here shortly. I will be looking into newer inverters spec way more before i purchase it... I agree 100% this is a unsafe practice though there are ways around but there is to much IFs in the remedies to warrant use of this setup. NOT WORTH THE GAMBLE. Thanks for the in depth video with explanation and demonstration of what happens. My system is currently about 4-5years old, all i need is a glitch in one part and my wife/children are at risk. Honestly don't know how i haven't had a problem already.

  • @marksorel800
    @marksorel800 Месяц назад

    is it possible ti connect 3 of these inverters together ?

  • @joshm3342
    @joshm3342 Месяц назад

    If you HAD to do the fix shown here, I think it would be best to remove the circuit board and place an insulator pad between the ground and neutral points, just to rule out vibration-induced arcing. It could be as simple as a few layers of electrical tape.

  • @MrKHURRAM828
    @MrKHURRAM828 Месяц назад

    Thankful bro ❤🎉

  • @honeybadger6127
    @honeybadger6127 Месяц назад

    great video, learned quite a bit here. Love the experiments and the demonstration of what not to do.

  • @squee222
    @squee222 Месяц назад

    your problem is bad workmanship. Nothing wrong with this product. It's working exactly as it should. Make sure your panel lugs are tight and everything is built correctly - and only tie your neutral to ground at one point. Follow code.

  • @JeZzUzZiN
    @JeZzUzZiN Месяц назад

    Hi, quick question. Do the LVX6048 also have the same issue?? I believe they also have the auto transformer.

  • @Peter-o
    @Peter-o Месяц назад

    Is it allowed to mount them with cables facing downwardly?

  • @osvaldogarcia3197
    @osvaldogarcia3197 2 месяца назад

    Hi I try with my 6000T but program never come up after clicking the icon, but if I disconnect my USB com3 then the program come up but doesn't detect it, try with 2 cables, 2 laptops and different comes and it do the same, I also factory default the unit but no joy, uart windows driver was installed so not sure if the inv USP port is good or not. Anyone with the same issue ???, the unit is only 5 months old...

  • @dama054
    @dama054 2 месяца назад

    Hi Ian I am having a bit of a issue with the solar assistant I have got two inverters in parallel and when I use charge source priority and set a time to charge from the grid it only charges from one inverter and not both any ideas how to fix this please

  • @hendersonsobers396
    @hendersonsobers396 2 месяца назад

    Hi Ian, thanks for this video. I'm seriously considering this inverter for dedicated EV charging solution. Is there a mobile app for this inverter? And if not, is it on the roadmap? .

  • @CoconutInformation
    @CoconutInformation 2 месяца назад

    Whoa! RUclips should show this to everyone searching diy solar.

  • @ralph9987
    @ralph9987 2 месяца назад

    Does this inverter create RFI?

  • @EdgarIsaacDLRO
    @EdgarIsaacDLRO 2 месяца назад

    It work this cable with my MPP SOLAR LVX6048 AND JK BMS (NEW VERSION). Thank you for this video

  • @dirtyburd71
    @dirtyburd71 2 месяца назад

    How about side and top clearances for the mpp unit?? Did it stay cool or not??

  • @jessstuart7495
    @jessstuart7495 2 месяца назад

    Floating an inverter will disable some of the inverter's surge protection.

  • @underwaterworldmckay5502
    @underwaterworldmckay5502 2 месяца назад

    If its running off the batteries only, what's the low voltage cut off for it?

  • @AManofGod01
    @AManofGod01 3 месяца назад

    As always you sold me Ian. Just ordered one.

  • @a64738
    @a64738 3 месяца назад

    I have one of these connected to my 4 Lifepo4 batteries that is connected in both series and parallel. But even if I double triple and quadruple checked I somehow managed to connect it to the battery with - and + wrong, I do not know if it is ruined or not as it does only light up when it is balancing?

  • @RJ-cc1fz
    @RJ-cc1fz 3 месяца назад

    Will it supply the homes main panel with battery and or solar power by utilizing only the grid input connections. Doing zero export with Cts?

  • @Greg-bx4id
    @Greg-bx4id 3 месяца назад

    Either discharge the higher voltage battery or charge the lower voltage battery. too easy

  • @mendohomepower7492
    @mendohomepower7492 3 месяца назад

    Am I correct in assuming that load 2 is similar to the Smart Load on the Sol-Ark?

  • @jimcalver-oj4xf
    @jimcalver-oj4xf 3 месяца назад

    I see risk of a set of keys or random pocketed screwdriver potentially causing a nasty arc-flash or fire. Too many exposed terminals of high capacity battery modules and breakers that should be metal boxes. Wow! But really cool from a tech head perspective.

  • @offgriddreaming5403
    @offgriddreaming5403 3 месяца назад

    Hi Im assuming all lifepo4 chemistry is that right? Are they the seplos bms or all different? Also what brand are those big breakers please?

  • @offgriddreaming5403
    @offgriddreaming5403 3 месяца назад

    Wow. Impressive, makes my little system look like a toy 😂

  • @bimmers323ci
    @bimmers323ci 3 месяца назад

    do you have trade in

  • @bimmers323ci
    @bimmers323ci 3 месяца назад

    does the inverter comes with free shipping

  • @Roll2Videos
    @Roll2Videos 3 месяца назад

    Nice job Ian, Keep up the great work 👍

  • @MrShaneo369
    @MrShaneo369 4 месяца назад

    Ian can these work outside the US on 50hz?

  • @Angelica._.officalll
    @Angelica._.officalll 4 месяца назад

    Is it possible to limit the wattage AC OUTput on each leg to say 500W?

  • @Detour4it
    @Detour4it 4 месяца назад

    Im using an old trace sw5548 and have picked up the trace T240 autotransformer. The inverter has its own transformer. Following trace manual for wiring in their autotransformer shows the same wiring. Will my system present as a hazard if I do add the transformer?.... Ah, I asked my question too soon it seems? This is a European issue with the way their power is delivered not a problem in the US? Just need verification because, as youve stated, our 230 transformers utility pole Y type delivers 120 each leg with common/neutral center.... correct?

  • @Madsci-zy8wm
    @Madsci-zy8wm 4 месяца назад

    Is the Nhx-10kw inverter a low frequency, transformer based inverter or a high frequency, transformerless inverter?

    • @450kman
      @450kman 3 месяца назад

      high freq

  • @davefroman4700
    @davefroman4700 4 месяца назад

    Ian has enough storage to keep a city block lit up for a few days...

  • @darrenorange2982
    @darrenorange2982 4 месяца назад

    Ian, so for us with the older now LV5048 or LV6048, what is our best upgrade path. For me I built my solar array with the benefits of the lower VDC of the solar inputs on the 5048 so I can tolerate shading easier but now most of these new inverters won't work with my configuration ~40ish volt panels in 2P so around 80-90V. What is the best option and I can't get another 5048(to combine two) or easily upgrade my 5048 to anything.

  • @niktak1114
    @niktak1114 4 месяца назад

    What are the surge/peak power specs?

  • @damienparker3541
    @damienparker3541 4 месяца назад

    Absolute gold info, showed me so many things i didn't think were possible. I have a Hive (Alpha Ess) battery, grid connected. 5.8 KWH 3KW output and was told i cannot add a different battery without removing this one. What do you think?, Is it possible with grid connect to add another battery, I have 2 seperate solar arrays with 2 seperate 5kw inverters

  • @bobmonztr
    @bobmonztr 4 месяца назад

    Put a voltmeter on your leads, that inverter voltmeters are not accurate, your charge is most likely 2v higher than set #, same with float. When not charging inverter will show -1.5 lower than actual. Glad to see you got the new display. Now you have to lower the values enough to be accurate and not overcharge. The new display shows clipped values and the charge volts # is float volts on mine .

  • @dama054
    @dama054 4 месяца назад

    Hi Ian I'm using solar assistant and when I program the inverters I am running in parallel only the first inverter changes charge source priority not the second one can you help please I'm running two u5648ms inverters

  • @회기-c3w
    @회기-c3w 4 месяца назад

    I purchased this model for a lead acid battery stack of two 12v batteries. It started to work and the B light was flashing as that battery voltage was much higher. After a few minutes I heard a pop and the B light stayed on steady. The batteries did eventually balance, but then the B battery voltage became higher than A, yet the light for the A battery continued to stay lit. It seems the balancer failed within 5 minutes of installation.

    • @a64738
      @a64738 3 месяца назад

      Did you do same mistake I did? I managed to connect + and minus wrong even if I checked to make sure like 20 times...

  • @dama054
    @dama054 4 месяца назад

    Hi can I connect two inverters of the same type to the solar assistant when they are not in parallel

  • @JR-xw5dk
    @JR-xw5dk 4 месяца назад

    I was thinking that the Lux power units were the best value for the money now you have caused me to rethink things. A good unit for the money. Good job. Not in a position to install anything yet.

  • @alexisbonilla5942
    @alexisbonilla5942 4 месяца назад

    The solar system will last much more than the Lightning

  • @luiscastillo861
    @luiscastillo861 4 месяца назад

    Hi i recently aquired a kit of 5 V5 pytes batteries. I wanted to add these to my current 48100R pytes battery bank of 600ah. (around 30Kwh). Unfortunately i was told i cannot parallel them because they are different model. Can you tell me how can i make them work together? many thanks

  • @450kman
    @450kman 5 месяцев назад

    I feel you are correct in that it may not be the right bike for the job. Watching the development and eventual, often delayed, release of real product into the wild, I was always under the impression this bike was sharply motocross focused. Battery wise, it only has to last a moto. Suspension and handling wise, it is set up for a mx track. Surprised the handling/suspension differences between the ktm and SV were not mentioned. Maybe it was mentioned and I missed it, but for what you are wanting, how is the ktm? It appears to be a solid platform. Being a totally new product, it is not surprising it has some bugs. Oddly enough, I have not heard a single peep from any of the motocross channels about the charger, or throttle cutting out under full load. The throttle issue is something that is absolutely dangerous on a motocross track. Having the throttle cut out at the wrong time off a jump face could easily cause the front to rotate down causing an endo, easily resulting in serious bodily injury. Wow! This is a serious issue that never should have made it into the wild! Anyhow, yeah, I am jealous. Looks like you have a vast riding area, probably some great trails, and lots of toys to enjoy. Ride on.