Pyrotex Systems
Pyrotex Systems
  • Видео 38
  • Просмотров 193 140
NFPA 72 Requirements for Duct Smoke Detectors 2
Chapter 21 of the NFPA 72 deals with interfacing the fire alarm system with other building systems control units. This includes duct detectors.
Просмотров: 3 578

Видео

NFPA 72 Requirements for Duct Smoke Detectors
Просмотров 8 тыс.3 года назад
NFPA 72 Chapter 17.7.5 Smoke Detectors for Control of Smoke Spread. This week is all about what the NFPA 72 has to say about duct detectors.
Heat Detector Spacing Requirements
Просмотров 9 тыс.3 года назад
NFPA 72 Chapter 17.6 Heat Sensing Fire detectors. This week we take a detailed look at code requirements for the mounting and spacing of spot type heat detectors.
Smoke Detector Spacing Requirements Part 2
Просмотров 7 тыс.3 года назад
This is a follow up to last week's video. Now we are looking at spot-type smoke detector spacing with beam and joist type construction.
Smoke Detector Spacing Requirements Part 1
Просмотров 23 тыс.3 года назад
This week we took a good look at NFPA 72 17.7.3.2 (2016 edition) Spot Type Smoke Detectors and their spacing requirements.
HPF PS10
Просмотров 3,3 тыс.3 года назад
First look at the new Honeywell Fire power supply. The new HPF-PS series has both a 6 and a 10 amp version. In this video we take a look at the 10 amp panel and how to set it up for a typical fire alarm application.
Gamewell FCI S3
Просмотров 1,6 тыс.3 года назад
All about the Gamewell/FCI S3 panel.
Series & Parallel Circuits
Просмотров 6543 года назад
Series & Parallel Circuits
Silent Knight ECS & EVS Amplifiers
Просмотров 1,3 тыс.3 года назад
The ECS-125W is an intelligent amplifier that communicates with Farenhyt IFP series panels over SBUS and VBUS. Everything in this video will also apply to the EVS-125W amplifier.
5895XL & RPS 1000 Power Supplies
Просмотров 1,2 тыс.3 года назад
5895XL & RPS 1000 Power Supplies
SBUS, VBUS, & Binary Addressing
Просмотров 2,5 тыс.3 года назад
4 wire data circuits, low level audio, and using dip switches to set addresses.
Conventional Fire Alarm Power Supply Wiring
Просмотров 8 тыс.3 года назад
Whether you know this as the FCPS-24S6, the FCPS-24FS6, or the HPF-24S6 they are all one and the same with the exception of the sticker and key lock on the door.
Conventional & Intelligent Power Supplies
Просмотров 2,5 тыс.3 года назад
Check out details about the different NAC expander power supplies we offer, including a new model the Honeywell HPF-PS6 and HPF-PS10.
Project Life Cycle
Просмотров 2003 года назад
This is a bird's-eye-view of every step of a project from bid day to final payment and everything in between as well as steps to take for success.
Damper Relay Wiring
Просмотров 44 тыс.3 года назад
Wiring relays for smoke dampers
Smoke Dampers
Просмотров 2,9 тыс.3 года назад
Smoke Dampers
Pull Station for Door Lock Release
Просмотров 1,7 тыс.3 года назад
Pull Station for Door Lock Release
Fire Alarm Override of Electronic Door Locks
Просмотров 4,7 тыс.3 года назад
Fire Alarm Override of Electronic Door Locks
Shunt Trip Wiring
Просмотров 18 тыс.3 года назад
Shunt Trip Wiring
Elevator Recall
Просмотров 4,2 тыс.3 года назад
Elevator Recall
Wiring Switches - Intro to Relays
Просмотров 1,1 тыс.3 года назад
Wiring Switches - Intro to Relays
What Do You Say in an Owner Training?
Просмотров 1,3 тыс.3 года назад
What Do You Say in an Owner Training?
Multimeter Demonstration
Просмотров 6893 года назад
Multimeter Demonstration
What Is A Ground Fault, And How Do I Get Rid Of It?
Просмотров 1,3 тыс.3 года назад
What Is A Ground Fault, And How Do I Get Rid Of It?
Fire Sprinkler Systems and Alarm Supervision
Просмотров 1,2 тыс.3 года назад
Fire Sprinkler Systems and Alarm Supervision
Wiring Switches - Waterflows and Tampers
Просмотров 9 тыс.3 года назад
Wiring Switches - Waterflows and Tampers
Wiring Switches - Duct Smoke Detectors
Просмотров 5 тыс.3 года назад
Wiring Switches - Duct Smoke Detectors
Wiring Switches - Introduction and Basic Uses for Fire Alarm Systems
Просмотров 9643 года назад
Wiring Switches - Introduction and Basic Uses for Fire Alarm Systems
An Introduction to Relays & Switches
Просмотров 1,2 тыс.3 года назад
An Introduction to Relays & Switches
Texas Fire Alarm Rules
Просмотров 2,5 тыс.3 года назад
Texas Fire Alarm Rules

Комментарии

  • @perciusadlawan5853
    @perciusadlawan5853 4 дня назад

    Could you explain further the "top 15% ceiling height requirement"?

  • @MrPhoenix1800
    @MrPhoenix1800 12 дней назад

    Thanks for posting these videos. Going back around studying the NFPA 72 section right now, and these videos make it easier then just trying to read that dry book.

  • @armandoalmaraz3453
    @armandoalmaraz3453 16 дней назад

    How do you connect the HVAC shutdown wire to this setup

  • @paddyfanning2785
    @paddyfanning2785 Месяц назад

    Great vid really well explained 💪

  • @Daniel-qz4by
    @Daniel-qz4by Месяц назад

    Is the code similar to California ? Cause you explain this great and it’s helping me out understanding it. I take my FLS soon and this is good stuff

  • @elyestrada5197
    @elyestrada5197 2 месяца назад

    What do i need to do to program this panels?

    • @Txdcblues
      @Txdcblues 12 дней назад

      Camworks is the programming software

  • @JoeyKnight-t4s
    @JoeyKnight-t4s 2 месяца назад

    I’m going for my lvl lll,, I’m struggling with the math on how to space smokes ie,, what is the math for a room 30’X30’ or 250’X100’ ,,, I haven’t grasped it yet,, idk why the light isn’t clicking

  • @TheRealzPope
    @TheRealzPope 3 месяца назад

    Why does the pull station need to actuate the maglock (in your theoretical situation) directly? If the fire alarm goes into alarm, shouldn’t that automatically disengage all access control locks for the very reason of not trapping people?

  • @arshadshaikh8892
    @arshadshaikh8892 3 месяца назад

    I was searching for such information...not available anywhere else

  • @lifealliancegroup
    @lifealliancegroup 3 месяца назад

    They were not specific on distance for air handlers for larger than usual returns and supplies because it would depend on the rate of air flow, the direction and the manner in which the air is manipulated

  • @nicholasjacob7151
    @nicholasjacob7151 4 месяца назад

    I am new in this field

  • @nicholasjacob7151
    @nicholasjacob7151 4 месяца назад

    Good morning.please,which part of the building is the green cable wired to?

    • @PyrotexSystems
      @PyrotexSystems 4 месяца назад

      This would be your SLC wire, the data circuit that goes to you intelligent addressable devices such as smoke detectors or other addressable relays.

  • @alexanderaguilar8135
    @alexanderaguilar8135 4 месяца назад

    How do you connect three tamper switches and water flow to bell

  • @FNdotFM8
    @FNdotFM8 5 месяцев назад

    Just moved to Texas and looking to get licensed in the state.. do i need to be employed by a fire protection company to even apply for the testing?

    • @chrxsljc
      @chrxsljc 4 месяца назад

      I am also pursuing my FAL, and I’d say no bc the liscense IS what’ll land u the job in the first place 😅

    • @juhvibejerome
      @juhvibejerome 4 месяца назад

      I believe you have to be sponsored by a fire protection company

  • @MrDono215
    @MrDono215 5 месяцев назад

    Excellent video

  • @gabrielgonzalez8693
    @gabrielgonzalez8693 7 месяцев назад

    I have an ERV unit that needs 4 smoke duct detector 2 of them are for supply and return. I am clear about the airstream with those. Then I have one for exhaust air and the other for outside air. I am not clear where to face the sampling tubes holes on those. Can you explain how and why please.

  • @jamesfactstechnologies5200
    @jamesfactstechnologies5200 7 месяцев назад

    Pls can you do a video or connection diagram of how to interface DRN to shutdown AHU?

  • @ryanmcclain4963
    @ryanmcclain4963 8 месяцев назад

    Occupancy "I" is Institutional not "Industrial". Type "F" is factory which is the closest thing to industrial.

  • @Jeromyz91
    @Jeromyz91 8 месяцев назад

    How do I interconnect two of these

  • @Jeromyz91
    @Jeromyz91 8 месяцев назад

    How do I interconnect two of these

  • @erickrodrigues4499
    @erickrodrigues4499 8 месяцев назад

    if I have a ceiling 90 by 90 with 28 feet high?

  • @jamesfactstechnologies5200
    @jamesfactstechnologies5200 9 месяцев назад

    How many duct detectors can be installed in a loop.?

    • @PyrotexSystems
      @PyrotexSystems 9 месяцев назад

      That entirely depends on the manufacturer of the parts. There is not a code limiting that.

  • @LuisRodriguez-wo6nl
    @LuisRodriguez-wo6nl 9 месяцев назад

    I wanna Congratulate You guys for such superp videos . You guys are the real Deal !! The Best videos on Fire Alarm Systems on RUclips PERIOD !! No one comes even close . I learned and enjoyed watching every single video you posted so far...

  • @Will-o5u
    @Will-o5u 9 месяцев назад

    Why do fire alarm transformers get so hot to the touch and hum so loud. Is it normal? Have a Fahrenheit IFP-75

  • @OleksandrOnyshchenko-u8l
    @OleksandrOnyshchenko-u8l 9 месяцев назад

    Thank's for your advice!

  • @OleksandrOnyshchenko-u8l
    @OleksandrOnyshchenko-u8l 9 месяцев назад

    Thanks for advise!

  • @markospangos3355
    @markospangos3355 9 месяцев назад

    Thank you very much for n my case is a fire suppression system in a commercial kitchen. When the system is activated the pressure switch should send a signal to the solenoid valve to close. In this particular kitchen the solenoid is connected to the gas detector. Shall i connect my pressure switch directly to the gas detector?

  • @Patrick0900
    @Patrick0900 10 месяцев назад

    Great video. Great job explaining it to the audience.

  • @DimitriMastos
    @DimitriMastos 11 месяцев назад

    Great explanation 👍

  • @seanhelmer4437
    @seanhelmer4437 11 месяцев назад

    what do I look at for smoke detector requirements for commercial spaces?

  • @emanuels.6541
    @emanuels.6541 11 месяцев назад

    This is great. Anyone should watch this to know these basics yet new to so many. Great job well done

  • @mikedickinson9730
    @mikedickinson9730 Год назад

    Great video. Just out of curiosity, what is the code on requirement for holes in the sample tube for a 22 inch duct?

  • @noahghaly1
    @noahghaly1 Год назад

    Thank you for this video !!! Anyway we can get that PDF you’re referring to ? I have my test coming up soon and am hardcore studying

  • @AndrewHenderson23
    @AndrewHenderson23 Год назад

    Have you ever ran across an audio chain fault?

  • @serg4220
    @serg4220 Год назад

    Do you know who how to monitor battery power loss ? . I know the ac trouble if for the 120 power idk how to monitor the batteries

  • @cy7571
    @cy7571 Год назад

    Best explanation I’ve seen. You just made it simple, thanks!

  • @mr.breadNwater
    @mr.breadNwater Год назад

    Thanks for posting. What's the difference between contacts 1 & 2 on the addressable relay?

    • @cy7571
      @cy7571 Год назад

      They are the same I think a lot of people use contacts number two because they are on the same side of the relay. Most relays have more than one set of contacts so that they can operate multiple things however you need

  • @Frank-tv6xo
    @Frank-tv6xo Год назад

    Can you mount a duct detector inside the air unit at the beginning of the supply?

  • @ankitpanchal5766
    @ankitpanchal5766 Год назад

    Do we need to order EOL resistors separately or they are coming with power supply? And if yes, then of what value and how many? Can you please help with this? Thanks in advance.

  • @jkorymvp
    @jkorymvp Год назад

    que voltaje puedes utilizar con el modulo relay en nc o no

  • @eddieklemm661
    @eddieklemm661 Год назад

    thank you , great video

  • @eddieklemm661
    @eddieklemm661 Год назад

    Thank you , great explanation

  • @eddieklemm661
    @eddieklemm661 Год назад

    Thank you for your time and effort to put this training together , i really appreciate you and you are a very good teacher making this information relative and easy to understand . thank you

  • @eddieklemm661
    @eddieklemm661 Год назад

    Thank you for making these videos , so helpful and your teaching style is very clear and makes it understandable.

  • @turtulad.panpaisan5293
    @turtulad.panpaisan5293 Год назад

    How about small meeting room that won't have any 36 in. clearance from both supply and return, any suggestions on detector location?

  • @fechurch123
    @fechurch123 Год назад

    Hi we have a Kidde fire panel at our church. Everytime we sing and play music it goes off. No one can figure out why yet they say the system is good. Have you ran into this problem before?

  • @eddieklemm661
    @eddieklemm661 Год назад

    thank you , great video and presentation . i really appreciate you .

  • @qzorn4440
    @qzorn4440 Год назад

    Wow we have a Johnson system that is more like dealing with witchcraft. The new stuff fails with a song and a dance. If the WWW internet ran like this the world would be using the Post_Office. Anyway thank you for the wonderful overview information. 😎 Great job.

  • @flylife305
    @flylife305 Год назад

    Next time can you explain which wires you use to wire it example 14 2 and 18 2